Loading...
HomeMy WebLinkAboutBLD2006-01901 - BLD Letters / Memos - 3/14/2014 * gp13 COS MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street -— PO Box 279, Shelton, WA 98584 18544' www.co.mason.wa.us Shelton (360)427-9670 Belfair(360) 275-4467 Elma (360)482-5269 March 14, 2014 Pioneer Builders, Inc. PO Box 1094 Port Orchard, WA 98366 Re Building Permit Number: BLD2006-01901 re-6sion to stock plan, add 3rd bay to garage Dear Pioneer Builders, Our office has received a revision to the approved stock plan to add a 12-ft x 22-ft 3rd bay to the garage. In order to complete the building department review additional information will be needed which is listed below. PLAN REVIEW REQUIREMENT COMMENTS: 1. Based upon the information provided the removal of the approved wall will change the entire garage area to meet the definition of an irregular building defined in the 2003 International Residential Code Section(IRC)R301.2.2.2.2. As a result the irregular portions shall be designed in accordance with accepted engineering practice. As an alternative construction plans may be modified to comply with prescriptive requirements of the 2003 IRC. In addition the revised plans show that the narrow garage walls have been reduced from 2'10"on each side to 2'6". The modification will not comply with the prescriptive alternate braced wall allowed in the 2003 IRC. Where a building, or portion thereof, does not comply with one or more bracing requirements those portions shall be designed and constructed in accordance with Section R301.1 2. The construction plans include a design by Washington State licensed architect Thomas Herstad. When a design prepared by a Washington State licensed design professional is modified that design professional must approve the modifications. Please provide written authorization for modification sealed, signed, and dated by the design professional. 3. The roof framing originally approved as part of the stock plan has been altered from that originally approved and does not comply with prescriptive roof-ceiling code requirements specified in IRC Chapter 8. In addition the proposed roof framing for the 12-ft x 22-ft garage addition does not comply with prescriptive roof-ceiling requirements. Please provide a design prepared by a Washington State licensed design professional that addresses all roof framing elements for the garage including framing members at ridge,hip, and headers. In addition all required connections need to be specified and location identified. To complete an engineered analysis your design professional will need the following information: Approved code edition: 2003 International Residential Code Snow load: 25 psf Wind load: 85 mph, exp`B" unless determined otherwise Seismic zone: D2 When you have compiled the requested information please submit it to the Mason County Building Department, attention D. Coker. Please respond to comments, in writing, in the order listed. Revisions, required as a result of the engineered design, must be transferred onto proposed building plans. Where required,please return two sets of revised plans and documents along with two sets of calculations. If you have questions please contact me at(360)427-9670 ext. 510 or via e-mail at: dlc@co.mason.wa.us Sincerely, Debber Coker Mason ounty Building Department xaminer WordBLD2006-01901 Plan revision comments G NT WNTr- - - -- - -- ---- - -- - -- - I I I I I I i I I I in I I I x8 E M 4 5 B AM I � I 1 11le?"X RVENTS 1 (I ) L GA10 1 I 4 4 P ST I I 2 DA x Q 1 I ® 3) L OG � 1 I I I AG ES I I � I 1 4xe BE NM -- - - = a � � I DB J5 5 irf ry I 1 i I 1 I I p I I BL J575 i I I 6 I I C-)Xe PO T ON I 1 22' I x Vrqm �i I 1 oo ® ( L GR QW, F/ I —b 10 EA A— — _ — ,Ez�l h - I I I 1 Al I I Q I I v J �n I r--------------- ----J I 1 t ! I 1 I I I I I I I I I i I I O I I b" GONG WALL ON— I �^ I I b"x 12" GONT FTG I iv I I I I I I I I I I bxlO P05T ON I I / 30"x 30"x 12" FTG I I I I I I I I Q I I I Ll L---JI I I ; F I I I I O 1 1 I I O I I I I I I I I I I I I I I I *• I I I I IL--------------------� I ww�6 I I I O' 1 L-----------------------------------J W14 — -------------- --------------- iao—av a 'Ida 0Gam' qe sc 14'-1�" (3) 3060 5}{ 2021 PIG ail�r MASTER 5E1DRM _ V 13'2x15'6 N d Q' Q dJ N � O � dirt m n r\Gi2AWL SPAGE F R� \AGGES5 � I r 71 2668' LINEN n cV n i I I I (2) 6' f .fl I I 2 68 I 2'�4 N I i m O j I I I EMORM #5 � o'I 'x[Ile 2b(�2 I F 5H1 T 1 U �1I ( )2rol 55 BP 1 b'RK4 dbi I, ! o 47—- l4T r RN p/8I ITrFF X --- IRE L CL& D 3L J 5 AR 6r -\ DB JSi S 10 P 5T -- —7_xl8' —J-- �_ I 8'O x 8'O OHR I I G G I I I 212 T5 ® I "LU I O j r a- VO x 'O H 17R I 'O 8' Of 4 D I I I N I I I I I I O I I I II N I 1/5"xl2" GLUE-LAM —EA I I I N I O -O" 61-5" 12'-0" �aljl- - �OA a prouex�' ta'"�^ �•""� BARGE KT.®Ml YMIm BARGE w/RAKE I I yAR 6GLr Il1.tlYI 'LM � •MGU ..nn 1 V O YI•Y•OG I Q �V]1 tl'M.M'OG VALLEY NAILER(TYP) ry tu t '•air z I w Q m Jl L LVL VALLEY RAFTER(TYP) Q i � I GRIG T 2x12 RAFTS® 4( OG I � I � I O RID E ( I O ry vi i W® q > � p I � f N I i I li COMP ROOF OVER 1/2" 5HTHG =_ ALT: CEDAR 5HAKE5 5/4 x 8 BARGE w/ Ix5 RAKE £ " � 2 I IL CONT RIDGE VENT- 12 12 EB r � a Q O -- --FLOOR -- -FLOOR Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar IP14 P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection November 24, 2008 PIONEER BUILDERS PO BOX 1094 PORT ORCHARD WA 98366 Case No.: BLD2006-01901 Parcel No.: 122185000010 Proiect Description: New SFR Stock Plan #2003-009 The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $68.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $68.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 595. Sincerely, Rich Todd Balderston Mason County Department of Community Development Cc: Property File November 24, 2008 BLD2006-01901