Loading...
HomeMy WebLinkAboutCOM2015-00110 Cell Tower Changes - COM Permit / Conditions - 9/16/2015 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line (360)427-7262 Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 IAcJ COMMERCIAL BUILDING PERMIT COM2015-00110 OWNER: T-MOBILE/ALLYN/SPECTRASITE RECEIVED: 7/23/2015 CONTRACTOR: LICENSE: EXP: ISSUED: 9/16/2015 SITE ADDRESS: 19943 E STATE ROUTE 3 ALLYN EXPIRES: 3/16/2016 PARCEL NUMBER: 122172200032 LEGAL DESCRIPTION: N 1/2 NW 1/4 EX ST R/W TR B SURVEY 9/137 PROJECT DESCRIPTION: DIRECTIONS TO SITE: CELL TOWER ALTERATION: REPLACING 3 ANTENNAS AND ADD 3 FRLB ON GROUND. General Information Construction &Occupancy Information Type of Use: CELL TOWER Insp. Area: No. of Units: Type of Constr.:No. of Bathrooms: Occ. Group: Type of Work: ALT Fire Dist.: 5 Valuation: $ 15,000.00 No. of Stories: Exit Design. Load: Building Height: Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: Model: Width: Building: Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline& Planning Information Front: N Ft. Shoreline: Ft. Rear: S Ft. Slope: Ft. Water Body: Shoreline Desig.: Not Applicable Side 1: E Ft. SEPA?: Comp. Plan Desig.: Side 2: W Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2015-00110 Please refer to the following pages for conditions of this permit. Page 1 of 5 Plumbing Fixtures Mechanical Fixtures FEES Type aty. Type Qty. Type By Date Amount Recoipt Plan Check Fee ARN 7011MIF tlAj'Al c,)7nlFnn Building State Fee InN 71TV,411F Sid Fn R99n1Fnn Building Permit Fee .1AN 70119n1A "M Sr, gMisnn Planning Review Fee ARN 7010nIA TAAn nn G97n1rnn Total $749,06 CASE NOTES FOR C O M2015-00110 -'�Y- A'" CONDITIONS FOR COM2015-00110 i 1) Approved perl dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 2) The proposal shall be In full compliance with the Mason County Cell Tower Ordinance#5-98 (Revised by Ord. No. 53-04). X 1M The design of the equipment buildings and related structures shall, to the extent possible, use materials, colors, textures, screening and landscaping that will blend the tower facilities to the natural setting and built environment.X W 3) All construction and demolition debris must be removed from the shore area after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. 4) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or properties. Silt fencing or straw must be installed and maintained until upland vegetation has become established. X rNlrS 5) All other necessary permits from Mason County,Washington State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X MS RECEIVEI SEP 2 2 2015 426 W. CEDAR ST. COM2015-00110 Page 2 of 6 6) The following special conditions should be made a part of the building permit: 1. Electrical Permit Required. The electrical system shall be installed under a separate electrical permit issued by the Washington State Department of Labor& Industries (L&i). Electrical"final"inspections must be approved by L&I prior to requesting a building final. X- Ms 2. Special Inspection: IBC Chapter 17, Section 1704. In addition to the inspections required by IBC Section 109, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under IBC Section 1705. The special inspectors'duties& responsibilities shall be as specified In 1704. All special inspection reports shall be provided to the Mason County Building Department in accordance with IBC 1704.2,4. Prior to final inspection, the special inspection agency shall also provide a final, signed report to the building department stating that all items requiring special inspection and testing were fulfilled and reported, corrections of any discrepancies has been completed, and, to the best of their knowledge, are in conformance with the approvgd design drawings, specifications, and applicable provisions of the code. x M 3. Special Inspection Contractor Responsibilities. Third-Party Special Inspection is required in accordance with IBC Sections 1704 & 1705 for the items identified in the Statement of Special Inspections (as required by IBC Section 1704.3). In accordance with IBC Section 1704.4, each contractor responsible for the construction of the work listed in the statement of special inspections shall submit a written statement of responsibility to the building official and the owner prior to the commencement of work on the system or component. The contractor's statement of responsibility shall cont on in acknowledgment of awareness of the special requirements contained in the statement of special inspections. X �.� 4. All Construction: All construction shall meet or exceed all local ordinances and the requirements of the 2012 International Codes as adopted by Mason County and Washington State. Occupancy is limited to the approved and permitted classification.Any non-approved change of use or occupanc could result in permit revocation and/or Code Enforcement action. 5. Field Correct: The construction of the permitted project is subject to inspections by Mason County Building Department.All construction must be in conformance with the 2012 International Codes as adopted by Mason County and Washington State.Any corrections, changes or alterations required quiredbyca building or fire inspector shall be made prior to requesting additional inspections, 6. Final Inspection Required: All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or failure to obtain final approval prior to expiration will be documented in the legal property records on file with Mason County as being non-compliant with the city's ordinances and building regulations and may be referred to the City Attorney for action. X,_ 7. Permit Validity: IBC 105.4/IRC R105.4:The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code,or any other code or ordinance of Mason County. Permits presuming to give authority to violate or cancel the provisions of the building code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring correction of errors in the construction docurents and other data. The building official is also authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinances of this jurisdiction. X "V) 8. Permit Expiration: All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that COM2015-00110 Page 3 of 5 circumstances beyond the control of the permit holder have prevented action from being taken. X MS 9. Engineering or Architecture: Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, or changes are made without approval from the architect or engineer and the Building Official, approval will not be granted, and a re-Inspection fee may be charged by Mason County prior to any further inspections being performed or approvals granted. x 15 10.Sales Taxes: This work is being done in Mason County. All sales tax for materials delivered to, or work performed in Mason County shall be sourced to Mason County. Prior to final approval, a completed supplier/sub-contractor list may be requested by Mason County to identify suppliers that delivered materials to the project site, and sub-contractors who performed work on the site. X Mob OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided Is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permittapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work Is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. ow�' A 2-Z l� Signature Date �{�rialn OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to lndlcate i i I i COM2015-00110 Page 4 of 5 CODEPROS -. September 6, 2015 Mason County DCD Barbara A. Adkins, Director 426 West Cedar Street Shelton, WA 98584 Re: Building Permit# COM2015-00110, 19943 E. Highway 3, Allyn, WA Occupancy Group: U Construction Type: II-Tower Occupant Load: No occupancy Dear Ms. Adkins, The construction plans for the Mariah Stevens / T-Mobile Cell Tower Antenna Alterations have been reviewed for compliance with the 2012 International Building Code as adopted by the State of Washington, as well as any locally adopted amendments to the codes. The construction plans have been found to be in substantial compliance with the adopted codes, and provided the special conditions identified below are incorporated into the building permit, we recommend approval of the construction documents in accordance with IBC Section 107.3.1 . The following special conditions should be made a part of the building permit: 1 . Electrical Permit Required. The electrical system shall be installed under a separate electrical permit issued by the Washington State Department of Labor & Industries (L&I). Electrical "final" inspections must be approved by L&I prior to requesting a building final. 2. Special Inspection: IBC Chapter 17, Section 1704. In addition to the inspections required by IBC Section 109, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under IBC Section 1705. The special inspectors' duties & responsibilities shall be as specified in 1704. All special inspection reports shall be provided to the Mason County Building Department in accordance with IBC 1704.2.4. Prior to final inspection, the special inspection agency shall also provide a final, signed report to the building department stating that all items requiring special inspection and testing were fulfilled and reported, corrections of any discrepancies has been completed, and, to the best of their knowledge, are in conformance with the approved design drawings, specifications, and applicable provisions of the code. X�lepro&LLC Page I of,, P.O.Box 185 Allyn,WA 98524 CodeProsWA.com 3. Special Inspection Contractor Responsibilities. Third-Party Special Inspection is required in accordance with IBC Sections 1704 & 1705 for the items identified in the Statement of Special Inspections (as required by IBC Section 1704.3). In accordance with IBC Section 1704.4, each contractor responsible for the construction of the work listed in the statement of special inspections shall submit a written statement of responsibility to the building official and the owner prior to the commencement of work on the system or component. The contractor's statement of responsibility shall contain acknowledgment of awareness of the special requirements contained in the statement of special inspections. 4. All Construction: All construction shall meet or exceed all local ordinances and the requirements of the 2012 International Codes as adopted by Mason County and Washington State. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy could result in permit revocation and/or Code Enforcement action. 5. Field Correct: The construction of the permitted project is subject to inspections by Mason County Building Department. All construction must be in conformance with the 2012 International Codes as adopted by Mason County and Washington State. Any corrections, changes or alterations required by a building or fire inspector shall be made prior to requesting additional inspections. 6. Final Inspection Required: All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or failure to obtain final approval prior to expiration will be documented in the legal property records on file with Mason County as being non-compliant with the city's ordinances and building regulations and may be referred to the City Attorney for action. 7. Permit Validity: IBC 105.4/IRC R105.4: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code, or any other code or ordinance of Mason County. Permits presuming to give authority to violate or cancel the provisions of the building code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring correction of errors in the construction documents and other data. The building official is also authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinances of this jurisdiction. 8. Permit Expiration: All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. 9. Engineering or Architecture: Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, or changes are made without dePra LLC Page_'of; P.O.Box 185 Allyn,WA 98524 CodeProsWA.com approval from the architect or engineer and the Building Official, approval will not be granted, and a re-inspection fee may be charged by Mason County prior to any further inspections being performed or approvals granted. 10.Sales Taxes: This work is being done in Mason County. All sales tax for materials delivered to, or work performed in Mason County shall be sourced to Mason County. Prior to final approval, a completed supplier/sub-contractor list may be requested by Mason County to identify suppliers that delivered materials to the project site, and sub-contractors who performed work on the site. It has been our pleasure to work with you on this project with our mutual desire for safety in the built environment. If you have questions or concerns, please contact CodePros at 360-801-0543, or contact me directly at mbarth(ab-codeproswa.com . Sincerely, Digitally signed by Michael J.Barth,M.C.P. Date:2015.09.06 09:48:36-07'00' Michael J. Barth, M.C.P. Building Code Consultant CodePros.LLC cc:file CodePros,LLC Page 3 of 3 P.O.Box 185 Allyn,WA 98524 CodeProsWA.com ULLD 1 N G MASON COUNTY PERMIT NO.W' �� D l B BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 E C E ITT E D Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-52� On the web www.co.mason.wa.us HIS APPLICANT INFORMATION CONTRACTOR INFORMATION OwnerT-Mobile c/o Rvka Consulting Mariah Steve company Name TBD Mailing Address 918 S. Horton Street Suite 1002 Mailing Address 426 W, City Seattle State WA Zip Code 98134 City State Zip Code Phone 2 0 6-5 2 3-1941 Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address mstevens@rvkaconsulti_ng.corn E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No 12217-22-00032 Fire District Legal Description N 1/2 NW 1/4 EX ST R/W TR B Survey 9/137 Site Address(Please include street name, street number and city) East 19943 Highway 3 Allyn, WA 98524 Directions to site On page 1 of the construction drawings Will timber be cut and sold in parcel preparation?Yes/��: Is property within 200'of Saltwater No Lake No River/Creek No Pond No Wetland No Seasonal Runoff No Stream No Slopes or Bluffs ] 15% No Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Ye TYPE OF JOB - New Add Alt X Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building Ci Lk Trl0 i- Describe Work i^, a 1 ZZX 21.- 1''p9(aou No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HO TION - Make Model Year Length Serial No. No. of Bedro Ins No. of Ty Purchase ee$' Replacem s No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CO NUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X fn /� -� (Agent) Date• 7/17/15 Owner/Owners Representative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date 7-2 3-2o i5 DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department ­t-z„ten Planning Department onmental Health Department Public Works Department Eire arshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing &Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ iS K, TOTAL FEES ' -7`-{ 9 Q 1 PLANNING T III -Mobile PROJECT INFORMATION: RECEIVED I ALLYN/SPECTRASITE I \ SE06Q56A JUL2 3 2015 PROPERTY LINE 130'± \ EAST 19943 HIGHWAY 3 \ ALLYN,WA 98524 426 W. CEDAR ST. ISSUED FOR: \\ BUILDING PERMIT REVISION HISTORY: CNK. OO� \ NO. DATE: DESCRIPTON: BY: MASON COUNTY DCD PLANNI G \` SITE PLAN REQUIRED TO BE ON SIT \ O G� CHANGES SUBJECT TO APPROVAL � By Date Q�oP�a�vN�,y�* `p q9 -- 0 F� IO 6111201S REV PER REDLINES BJT UJ 2 �p SQ82015 ISSUED DESIGN REVIEW BJT PLANS PREPARED BY: a a B. J. THOMAS, P.E. 7607 BOTH AVE NE MARYSVILLE, WA 98270 TAX LOT \ 206-851.1106 #12217-22-00032 \ \ DRAWN BY: CHK.BY: \ AAL BJ (E)T-MOBILE BTS CABINETS 8 EQUIPMENT MOUNTED ON(E)CONC PAD WITHIN(E)CHAIN LINK FENCE COMPOUND \ (SEE SHT.A-1.1 FOR ENLARGED SITE PLAN) i1 \ 12 LICENSURE: N W \ Z (E)T-MOBILE ANTENNAS 8 RADIOS MOUNTED W1(E)PLATFORM TO(E)150'AGL STEEL MONOPOLE i (SEE SHT.A-1.1 FOR ENLARGED SITE PLAN) w _ s a \ x� Er OIL \ •/ J \ 'T \ DRAWING INFORMATION: DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY \ ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY \ ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. PROPERTY LINE 540'± THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. I DRAWING TITLE: OVERALL SITE PLAN OVERALL SITE PLAN 22x34 SCALE:1"=40' DRAWING NUMBER: N 1 tx17 SCALE:1"=80' 40' 0 20' 40' 80'