Loading...
HomeMy WebLinkAboutAntenna Attachements - COM Inspections - 7/27/2016 "'�IaKr aZan & ASSOCIATES , INC . GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION Judy 27, 2106 KA Project Number. 10616101 Victor-Michael Julien Code USA LP E-Mail: vjulien.code.usa@gmail.com 19785 W. 12 Mile Road,Suite#335 Phone:(248)252-2780 Southfield,MI 48076 RE: Structural Observation Letter SE06056A—Allyn/Spectrasite East 19943 HWY 3 Allyn,Washington Dear Mr.Julien, Per your request, we have prepared this structural observation letter of the antenna attachments for the above mentioned project. We performed a site visit on May 31, 2016 to visually observe the antenna attachment. The site visit was performed by our certified climbers. For our use in preparing this letter, we were also provided with approved project drawings prepared by B. J.Thomas,P.E.,dated 6/11/2015. Based on our site visit and our review of the redline drawings, it is our opinion that the new antennas were installed per the approved plans. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN&ASSOCIATES,INC. S�PN CHAUp,1 you .e 51061 O'�'tt+ �NS7ER�� 4 ssz L ONA EEO, Vijay Chaudhary,P.E. Project Engineer Attachments: Site Photographs, Daily Field Report dated 05/31/16, and redline drawings dated, 12/11/2015. 922 Valley Avenue NW,Suite 101•Puyallup,WA 98371 •(253)939-2500•FAX(253)939-2556 With Offices Serving the Western United States 10616101-Allvn Cell T m VAR d r KA Project No. 10616101 July 27,2016 Page No. 2 �M� a ' aW Y E 4 a� \ New Antenna , �g Krazan&Associates,Inc. Offices Serving The Western United States KA Project No. 10616101 July 27,2016 Page No. 3 L; a! New Antenna Attachment s Krazan&Associates,Inc. Offices Serving The Western United States KA Project No. 10616101 July 27,2016 Page No.4 E New Antenna yi Krazan&Associates,Inc. Offices Serving The Western United States � o 5� &0 �y��7Cl FIELD • i+. an&A s s o c i a t e s,I n c. REPORT NO.: 16101 DFR053116-AC Geotechnical Engineering•Environmental Engineering Construction Testing and Inspection DATE: 5/31/2016 CONTRACTOR: CODE USA FM PROJECT#: 10616101 PERMIT#: PROJECT: SE06056A AJI /Spectrasite INSPECTOR: Aaron Clyde LOCATION: Mason County JURISDICTION: Mason County KA P.M.: WM WEATHER: Clear TEMP: 77° Krazan inspector is on site for new antenna bolt installation and inspection on a 150' monopole with the new antennas installed at 140'. Inspector reviewed plans by B.J. Thomas dated 6/11/15, page A2,A2.1,A3, and details. Inspector walked site for afety inspection, and ascended the monopole to the new antenna height(140') for inspection of the new antennas. Inspector noted the new Twin PCS EMA(2 per sector), and three new LNX—6515DS-AIM (1 per sector)mounted to the platform and pipes per details on page A3, with new manufacture supplied hardware. Inspector obtained photos of the new antennas and hardware. During inspection inspector noted the Birds Nest Excluder was not in place per plans page A2.1. Inspector descended he monopole and conducted a post climb site safety inspection. Reviewed By: ASTM Test#: Equipment/Asset Number(s): To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: Elatc Sgnature-SlgRusl Offices Serving the Western United States Lynnwood(425)485-5519•Poulsbo(360)598-2126•Puyallup(253)939-2500 Daily Ficld Repot Revision B Ef—i-0211]/20U the iaf d.ptosi w m pcmu—"f the dint u K—&A,socvtes.'Ibis repel indiat6 our mspccton obscntiun and tcslin6 results Iwsd m site wnditioos and motlxdor anivhia.Tho iof liuu is abjm to micro pia to foal submitul.tly,i�in6 tbn rayM,wr m�a dov nol TI Rsf�nibility fen wlidity o(reuln.Ibc.samc in(tvn hu Ean pnnidud by Chas on silc