Loading...
HomeMy WebLinkAboutSWG2024-00181 - SWG Application / Design - 4/29/2024 415 MASON COUNTY N 6TH ELTON: 0427-97 ,EXT 400 SHELTON:STREET,SHELTON, HEL-ON,W 98584 BELFAIR:360-276-4467,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX:360427-7787 On-Site Sewage System Permit: SWG2024-00181 APPLICANT 2018 BOWMAN PROPERTIES LLC Phone: Address: P O BOX 910 SHELTON,WA 98584 OWNER 2018 BOWMAN PROPERTIES LLC Phone: Address: P O BOX 910 SHELTON,WA 98584 SEPTIC DESIGNER PAULAJOHNSONe Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER JARED HANSON* Phone: 360-239-6792 Address: 86 SE BANJO LANE SHELTON, WA 98584 Site Address: 1711 SE RIDGE RD Primary Parcel Number: 320295003001 Permit Description: New 4bd Pressure sandlined bed with Class A waiver Permit Submitted Date: 0412912024 Permit Issued Date: 05/0212024 Issued By: Rhonda Thompson Current Permit Fees Paid: $805.00 (anmeonal Neu may 5e rewred upon lnsfalladon of system). Permit Expiration Date: 04112/2025 (based on died of map«non) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Meson County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.govlhealth/environmentallonsiteloss-inspection-request.php or call: 360-427.9670,extension 400. i OFFICIAL USE ONLY DALEPKENEU. . , ••® � 'MASON COUNTY y` c y COMMUNITY SERVICES AMDDL 5— ,10FRE. a y o w vuEEP1MMN ICammulMy XesIM✓fawlmnmmml HealBll N O SWIG ao� -06 o A 2 n ON-SITE SEWAGE SYSTEM APPLICATION n p m n IR 2018 Bowman Properties LLC Mike Bowman (360) 791-8855 c NAUNGMDRESS-STREET CrtY SATE,Z11. T 0) P.O. Box 910 Shelton WA 98584 m z $fTEPCDRESS-SiftEf?EITYIIPCCGE H 1711 SE Ridge Rd Shelton WA 98584 NAMEOFDENGNER FHONE F I N Arrow Septic Designs, Inc (3601898-2255 CD NAMEOFINSTALLER PHONE 0 Hanson Excavation (360) 239-6792 w I N PERMRTYPE(xP% ) p MINFINGW 11ASOURCE C O ®RESIDENTIAL O55 COMMUNITY O55 LYCOMMERCIAL 055 LL:PRIVATE INDIVIDUAL WELL Ill PRIVATE TWDPPRTY WELL 2 I � TYPE OF ROSS pac-PIMI ®PUBLIC MLATER SYSTEM L I5NEWCONSTRUCTION!UPGRADES I9REPAIR!REPUCEMENT OTREROETAILSfu,' TRS" RVyI [3TABLE IX REPAIR I � SUM.1mAL5 ❑ SURFACING SEWAGE m EXISTING FAILURE 17 SHORELINE 9SDESIGN FORM(REQUIRED) IIRSEPTIC DESIGN(REQUIRED) BEMOOMS LOTSCE 0 EEINAIVER(S(IFAPPLICABLE) 4 BR 32,352 sq ft O DIRECTIONS TO SITE AND SITE CONDITIONS.Rw b Mb1 Go up Hillcrest and tum (L)onto Cascade Ave. Turn (R)onto SE Ridge Rd. Destination on w w (R)-fruit stand property. o I o ti , IC3 =11USTBE FLAGGED FRbIMAM ROAD AMD TESTHOLES MUST BE FLAWED ADS MST ROLE NLMBERD. N f OFFICIAL USE ONLY BELOW THIS LINE — UPGRADE FAIWRE SOURCE IN/t N�, 13 VOLUNTARY OMAINTENANCE/PUMPING ❑BUILDING PERMIT ❑HOME SALE ❑COMPLAINT DOTHER INSPEGTORSIOLLOUS CAMMENT$/CONDITIONS 1 AD O � S�h� s � � u wb�y o � � � udr� COM�Ia 0 APR 29 2024 p� 10 REODRD DRAWNG AND INSTALLATION REPORT MNLCODFB: V-VERY 3-GRAVELLY S=SAND L-LOAM S.-SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL LNEPECMRRGNATURE DATE AIWLICATIONEXPIRATIONDATE APPUGATION APPROVEY ISSUED BY DATE THIS FORM MY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTYWEBSITE REVEEO12O2515 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 0 2 9 — 5 0 — 0 3 0 0 1 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dared. °Scaled layout sketch,including all applicable items on checklist r Scaled plot plan,including all applicable itents on checklist. I Cross-section sketch.including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Morimum pa err see: 11 PARCEL IDENI UPICAI[ON SO Permit Number. SWG ba ( b u Designer's Name: Arrow Septic Designs, Inc Applicant's Name- 2018 Bowman Properties Designer's LLC Desi er's Phone Number: (360)898-2255 Mailing Address: P.O.Box 910 Designer's Address: 171 E Vuecnmt Dr Shelton WA 985M Union. WA +`� Cirv_ State Zi City State Zip DESIGN:PARAME7l bRS Treatment Device ❑Glendon Biofilror ❑Sand Filter ❑Mound Sf Sand Lined Dminfield ❑Recirculating Filter.Type: ❑Aerobic Unit Make;Model ❑Disinfection Unit Make/Model Other: Solids pump in existing tank Drainfield Type ❑Gravity Ed Pressure ❑Trench 9f Bed ❑Sub Surface Drip Septic Tank/Drainfield Specifications - Laterals Number of Bedrooms 4 Schedule/Class 40 Daily Flow:Operating Capacity 360 gpd Length 60 ft Daily Flow:Design Flow 480 god Diameter 125 in v Septic Tank Capacity(working) 1,200 gal Number 4 Receiving Soil Type(Ifi) 3 Separation 2.5 ft Receiving Soil Appl. Rate 0.8 glad/fl" Orifices Required Primary Area 600 ft' V Total Number of Orifices 104 Designed Primary Area 600 ft` Diameter -5/32- in Designed Reserve Area 600 ft'- Spacing 28 in Trench7Bed Width 10 ft Manifold Trench/Bed Length 60 ft SchedulelClass 40 Elevation Measurements Length 7.5 ft Original Drainfield Area Slope 0 % Diameter 1.25 in New Slope.If Altered 0 % Preferred manifold configuration used? RrYes ❑No Depth of Excavation UPslope 20+24=44 in Transport Pipe from Original Grade i mslope 20+24=44 ill Schedule/Class 40 Designed Vertical Separation 26 in Length 140 ft Gravelless Chambers Required? ❑Yes It No ❑Optional Diameter 2 in 1/ Pump Required? 56 Yes ❑No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdoses/day 4 Diff.in Elevation Between Pump&Uppermost Orifice 20 ft Dose quantity 120 gal Drainfield Squirt Height/Selected Residual(head) 5 ft Chamber Capacity(food) 1,200 gal Pump centrals:Please check those required. Uppermost Orifice Higher ❑Lower than6656 p Shute m ✓ SfTimer h(Elapse Meter l�Evem Counter Capacity fa Total Pressure Head gp Calculated Total Pressure Head 4t31 ft If Timer: Pump on 1.5 minutes Pump off 6 hours Comments '`a p P 17.3 0�. ./r. Lj 'Y 0 2 =--q DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 0 2 9 — 5 0 — 0 3 0 0 7 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch Ed Test hole locations Rf Drainfield orientation and layout Reference depth from original grade: 9j Soil logs 56 Trench/bed dimensions and Rf Septic tank 9 Property lines critical distances within layout 9 Drainfield cover ❑ D-Box/Valve box locations ❑ Existing and proposed wells Reference depth from original grade within 100 R of property lZ Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts.banks,and locations G9 Laterals,trench/bed,top and surface water and critical areas 0 Observation Pon location bottom ❑ Location and orientation of 16 Clean-out location ❑ Curtain drain collector curtain drain and all absorption 19 Manifold placement 9 Sand augmentation components lig Orifice placement Other cross-section detail: m Location and dimension of R1 Lateral placement with distance Eig Observation ports/cleat-outs primary system and reserve area to edge of bed Other Information M Buildings Rf Audible/viAle, eferenced Yes No 9 Direction of slope indicator R1 Scale of drn on scale Rf ❑ Design staked out ❑ Waterlines bar , 59 ❑ Recorded Notices attached tJRf ❑ Waiver(s)attached RJ Roads,easements.driveways, . ` parking c.. ❑ Pump curve attached m North avow and scale drawing Gr! ❑ Evaluation of failure shown on scale bar 1. i6,aae Non-residential justification ' PFULA JOY JOHNSON'v ❑ 1 Waste strength dS .Q: .ICFYJ6 I Ek" ❑ 9 Flow DESIGN APPROVAL The undersigned designer must be not' by sta er at time of installation �Yes ❑ No �f ZZ-Zg- Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regy'lations: S �zr Environmental Health Spec alist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web slte: Updated Date: 12 7/2015 Arrow Septic Designs 171 E.Vummst Dr. Union,WA 98592 April 17,2024 Mason County Department of Health Services 415 N 6th St Shelton,WA 98584 RE: 2018 Bowman Properties LLC(Parcel N32029-50-03001)Evaluation of Failure Deer Inspector: Attached is a repair septic design for a property located at 1711 SE Ridge Rd,Shelton,WA 98584. There are existing buildings onsite,the first being a fruit stand/warehouse space with living space attached built in 1930 and the second being a small,detached structure built in 1960 that also has living space. We are designating the larger space as 3-bedrooms and the smaller space a I_be u known sizdroorn for e o dl of 4- ledrOOms- Each building has its own septic tank that tie into gravity es on. There are no original septic records. There are no public restmoms and the septic is used for residential purposes by the family that leases the property. The owner has been having some issues with the septic and the drainfields are not taking water properly.The existing tanks maybe reused if the installer determines that they are in acceptable condition. The tanks must be water-tight and have risers and lids to the surface for ongoing maintenance. The small building has an existing 2-compartment 900-gallon septic tank. An on-demand solids pump is to be added into the second cam and pump over to ber septic tank tthat can be reused he inlet of the Land an effluent filter added. The old drainfie dn septic tank. The larger building has Sm ts are to be ng allon comp abandoned in place. We are proposing the addition of a new 1,200-gallon shared pump chamber. The proposed new drainfield consists of 600 s.f of sand-lined pressure bed using an application rate of 0.8.The system will also have a control panel including timed dosing,a counter and elapse meter to prevent overuse and facilitate ongoing operation and maintenance. The property is on public water and there are no known wells nearby. We have designated a 600 s.f.reserve drainfield area. In compliance with the Table IX repair guidelines,this system meets Treatment Level B,has 24"+vertical separation with pressure distribution and timed dosing. A waiver is included to install in unoriginal disturbed soils. A Notice of Operation 6c MaintenanL been filed on the deed. MAY 0 2 2024 The property owner's contact information is as follows: MASON COIJN'rY ENVIRONMENTAL HEALTH 2018 Bowman Properties LLC RET PO Box 910 Shelton,WA 98584 Mike Bowman(360)791-8855 If you need further information,please contact my office at(360)898-2255. Sincerely c Pa "•P h ti�,), Lielsed t �,j water Treatment System Designer q Fw PAULA JOTY JO JOHNSON '. axPu�s a a a '� I �?•4 a..e'.e o` Egg \ ... � i _ .., ... r .� a'r. . . g Ji M3ca:'a On0 pp pp]•` Cso �� � :9�f5� 8 ` � go � a`ai; � T • € $ 1. ka vl gig Pt 3{53� & ,F' g- i • J S^ r�; i>Y: tx 3'•'-'Y � eY°FRi y :i 3Aa Az 3 to IS 4 Y1�� g31 iYuY to: e �� 3ea'Ey 9QNCOUNt oy 02202i �s aw � a Q � � � . 4fn a¢$ 3 .6Y � �s:ii �i. ie Y. EkVRphN ni 3 �a ea4� sg ap uric a� R El E' AI ALTH E . S n v r++ S\ � r t+w s � Z ,P �s a � al s of 0 1 LoJ - Q �X15T,1�[7 �r- LL To p�'�y.. �f2. 51 L03LB L dr*l $RED FI D✓�"" 'Q. PAULP JOY JOHNSON J56`Jo /M OL Ca , M' +4- LiCEYlSE W GR U iGNE ® z mot-fa M oD5?-� R®V� ® C� e.K > �t•yzA MAY 02 2024 'few`. MASON CCUNTYEWRONMENTALHEALT IBR —S � tjiDf�E (ZD 28j z1 , I{ev: �C Slecve u��-✓1;vim SCRE : \ " 3J h I� of ,5 qo 4s eo O Audio-Visual Alarm Net- w ,�"' PLo Cleanout A,L 1200 Gallon Septic Tank e- "CO ��lt�CEL 52202.�I� 3 2-ComPar=-t-AM II 5E tL \D CAE F-D Effluent Filter 9S5� 1 O4 1;200 Gallon Pump Chamber-JJPa.O C'k 30" 30' �5• yD^ pri{'2tt TyPi co\ S�aci-:5 If NO� ] 2�PPULF JOY JO JOHNSON 30 � �-Ltxsf �,+ o �abvp��raue9t,�yd. �"+ �toSa^AL `� 2�i ' ® �S�,c,.�C.ie-G•.;ik�! —croL...i.6+.'�'K-i9`�q�} e A ' _' 7 •F APPROVE SCREW ON CAP MAY o Z 20A . $ DEGREE ELBOW OR uHtv� . 'TtRALSWEEPING 9U NOTE. O=OSSERvATION PORTS--TO BE 4' SWD. END OE PVC PIPE FROM BOTTOM OF TRENCH TO FINISHED GRADE. REMOVABLE DITCB .� DETAIL CAP SHALL BE INSTALLED CLEAN—OUT 'T RSS4di Mlof OSSLI7V PORT n� PoeT• NOTE, CLEAN= TO BE FROM 0 TO 6 TOTAL OF AI' IN SYSTEM. INCHES BELOW FINISHED GRADE. (L) T' �11 bTR3L A7AB•R OK OK C 33 SAID MARK ENDS WITH REHAR. CLEAN OUT - **LATERALS ARE TO RE CENTERED 5&� q,RE40IEED AT END OF EACH LATERAL. IN TRENCHES. V Length Length Orifice # Distance from Distance from Lateral# (In. (Ft. S acing Orifices Feeder Line In.) Clean10 10ut(In.) 1 720 60 28 26 10 10 2 720 60 28 26 10 10 3 720 60 26 26 10 4 720 60 28 26 10 Total Lateral Length 240 Total#Orifices 104 GPM= with( (with 5/32 orifices) Dynamic Head Calculations 5 ft. Selected residual pressure. Length (Ft.) #Orifices Transport Pipe 140 104 8.20 ft. Feeder Total Lateral Line Length 2 O6 ft. Lateral#1 60 4 64 26 Lateral#2 60 2 62 26 2.00 ft. Lateral#3 60 2 62 26 2.00 ft. Lateral#4 60 4 64 26 2.06 ft. Total Elevation Lift 2000. ft. Total Dynamic Head 41.31 ft. T �f s � PAULASJC.YJJO SfGNkq HNS.0N 7jYl LICKNSctiT� "� ov�rtEc�s� APPROVED MAY 02 2024 CCU9TY EWRC, MENTAL HEALTH RET FL100-Series Off �qJ tJR�E�T External Construction Power Cord Pump Volute-Gray iron casting class 25 25'length standard.Quick-connect design allow easy field replacement (3!' fafable on single-phase; Pump Legs-Gray iron casting class 35'and 50'available on 3-phase) Powder coated casting Motor Level Control Oil-filled and hermetically sealetl Wide-angle mechanicat float sealed in a PVC housing.Float has a series plug for manual by-pass operation Class B insulation rating Water-stop seal in cord entry to eliminate water wicking into Stainless steel rotor shaft Single-phase models are thermally protected the pumpdek 3-Phase m0require overloads in control panel Adjustable clamp provided for optional pipe mounting of the float impeller Semi-open design.Cast iron construction Discharge Dual Shaft Seals 2'FN PT w th 14/2'FNPT cast Iron range prodded Upper unitized carbon ceramic and lower Vton°double lip Maximum Fluid TOMPGrErtUre 1WR 40oC Continuous Duty Fasteners 140°F.60°C Intermittent 300 series stainless steel CORD LENGTH WEIGHT MODELS HP VDLTS PHASE AMPS DISCHARGE AOTOMATIC IN F25EET IN,LLEE F10i 1 2a9-250 1 12 1-L2'68 No FL3024-2 1 206-230 1 12 1 J2 6 2 ves 35 72 FUL0314-2 208RS0 3 9 1-V2"62- 440-460 1-1i2'6P M10 25 T- FL1o4M-2 1 3 4° Z5 n F405M-Z.. 1 95 3 3.3 1 1J2"62 fb NSirOgTle.prvlSe mOtlC5.353nO50 cum opYOr¢d dxeble on}ya5ermtles.MO CnSm 35 -3 ro M 'o apt WGIC ec 3fOr3>cOIdr,03u5for w'rom. er IL PROVED Performance Curve 60 Hz 3450 RPM N'IAY Q 2 2 y asoHsouHrYElirgRonv wra�H�uH PET fw ti iin ] _ 66�1 .m [1 a] nccrdea p +e .d ep .o and mp w up swna s[wr4aewaoitclro Wi`X r.YJatnWl¢ 000A• -I- - Cognghhf 11O obeM pumps.1- 2023 M righp rese d.LLIT006169-R02123 Phone :III 1 1 �Ll �eraF Mr cwdwm uovnmawTwffs§AL 1 ..om@ fAOM FLOATIMMAT APPROH® RWR�E /IL{AHff FL191 eXi Sil ilk amrel+a a�- lw� C�wbee- _ LjDMTm RNTWTMiAL TW45AMUNON VALVEC"oS.1�!`nS AORRR RRIe�I RlRRE AMORNE -��tOORYMBD FII 'TT� MORWOWETONAM VALVE' RpIRMLi/�IOFFtEI6L .WOPOMOVOLLIME MOUIIRIR DICLOMPUMP _ .gl(CK YALYE' 1`�CV� \ ZOfl "U'V91TRIRI000• �0.A� RmRpflR CO/�MN. Emmeamlom CyPWALI 'NIA Septic Tanks must meet smdsrds required by WAC chap Z 6 2�and 9t RF Q must be on Deft of Health list of registered 7 Pe 3soM _ _ SEMM:220.040 M7 O®Trusted.Tested.Tough."' 70ELLE/P 1216 2 6 L Produtt iMonn c en Prsamaa am 0115 "eR lynem commana.t,ime PUMP COMPANY of Putlhcelien.CPO`cae'ry n9ar mg fi ar irmnurora+as JC7 l�S ll U EC`�NICAL DATA ��� t i v WASTE-MATE SERIES Models 270, 4270 Sewage/`Effluent or Dewaterfng PampS PRODUCTSPEaRUTIONS SINGLE SEAL Itgt'�m7 (2aiimml 617 Y lt63 mml Xone Power t Va ape 115 pr20 6316I 11121 mm; Pnaae t Ph ' ` Type Permenanl split raPalitpr Insulation Cie.B i "-� Operation automatic O�schame Size 2aNPi So AS Handling 41.mm)spheriwl whtls 16Y1fA' Cpp lengM ¢0'O nn)atandartl I9R mm —T Cam Type ULlateb 3wirenao,dne cord and pW9 I sMU [imadal Max Head ]9'l8.B m1 Max Flow Rate 1323PM(5X)LPM) ' Max.Operating Temp. t3g•F154Y1 Culin9 Oil filled DOUELESEIL Motor Protection fwionewhertnal overload 0.Y6 BCE CgD Camirop, [t=tmml i=tt mml 6tY.4'[1m man: Motor xouam, Caatvan P rnp Xouaing Cast imn a34'(1g1mml * Base Cast irpno engineered plastc uppar Bearing Sleeve bearing Lower Searing Ball beann, Mxheniml5eala Camao and ceramic Impeller Type Non-clogging vpr:u ' Impeler Engineered plastic - HaMw-re 3ti nlass steal =' Motor Shah its S45C rtaal rBgy,g. Gaake[ Neopren [475 mml Min.Basin Siu OupSlmlaz's 36'x36'196x 762 ccml B1H'U53mIN - I � NOTE: Ttla alam9 of efFluent sys[ams nprmally raquires variably level float!-) vr5ax comno's and pmperlysiud basins[o achieve required pumping rydea Pr fleeing h cmati4 pampa. APPROVED NOTE:See model model comparison chart for apecifc details. • May beused infioseataroayAere GOdesda mi2saittaclidssile ine(fluen[rysrems. PAY 02 2024 C)''JNTf ENVIRO!+4ENTIL HEALTH w RET aaaaaaded ®Copyright 2016 Zoeller'Co.M fights reserved. 502-r,.2]3t i 8OM28-7867 1 364S Cane Run Road I Louisvitle,KY Q211-1961 I '4"�`°=oelleocom q � ll 2-Com artment Se tic Tank with Solids Pum in Second Chamber SM=W LW JWH ws TSGFff U"� 1 ACCM■> t FSHM TRADE p=TMG MAT �� Lbvc w Septic Deoigw < " INSTALLATION &MAIN TENANCE f "' Pressure Distribution Systems—Sand Lined Bed ✓�' PAULA JOY JOHNSON'yi ' 'tICKJ/sE 17hstGN - 1. install Laterals with contour of the ground. Fxv+ars + 2. Install bed bottom level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan, One required in each comer `foih�e bed. Two with bottom extending to the bottom of the drainrock and two extending sand/native soil interface. Glue`"P'to bottom so Observation Port cannot beleasily removed from ground. Install removable cap on top of pow at final grad e leve must be 5. Install drainfield during dry weather and soil conditions; y i eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals(cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch requited. 8. Install 1/8"mesh non-corrosive pump screen(min. 12 sq. ft. surface area,not to interfere with controls or floats.) Or pump screen may be substituted with Bio-Tube in septic tank. Pull bio-tube every 6-12 months and flush back into tank. back into the 9. Install check valve in pump outlet line to prevent system from draining pump chamber- 10.Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue),after pressure test and Environmental Health Dept. approval,nun orifices down(6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 11.Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 12. Encase all water lines within 10, of drainfield and under any driveway/parking areas. 13. Divert all storm water runoff away from on-site sewage system. 14.No curtain drains allowed within lo' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. or inspected every 3 to 5 years. 15. Have the septic tank and pump chamber pumped nspec 16.No vehicular traffic over drainfield area 17.Inspect floats,clean filters,and test high water level alarm every 6-12 months as needed. 18.All materials and workmanship must meet County and State regulations. 19. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will snake this design null and void. 20. All manhole lids and access,sampling or inspection ports must have locking covers and be located at ground level. 21. All pressure systems m with a pup tl chamber ouet higher than the drainfield must have a I/8"hole drilled in the disc pipe above the pump to prevent siphoning. 22. All transport lines under driveways or parking areas must be encased to prevent crushing. 23.Homeowner is responsible for all property lines. u�u