Loading...
HomeMy WebLinkAboutBLD2005-02134 SFR - BLD Permit / Conditions - 5/18/2006 Line 360)427- 262 ection } MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phonpe: (360)427(9670,ext7352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 l� RESIDENTIAL BUILDING PERMIT BLD2005-02134 OWNER: LINDA KNIPHER CONTRACTOR: 2.`"Y-1Z LICENSE: EXP: RECEIVED: 12/19/200506 SITE ADDRESS: 2648 E STATE ROUTE 302 BELFAIR ISSUED:EXPIRES: 5/18/20 5/18/200 PARCEL NUMBER: 1221621 00069T _`,' 06 LEGAL DESCRIPTION: TR 6 OF GOVT LOT 1 & TAX 84513-3 PROJECT DESCRIPTION: DIRECTIONS TO SITE: New SFR .7 miles North of power lines that cross North Bay on SR 302, approx. .3 miles south of Coulter Creek Rd. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: 4 Occ. Group: R3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:2,202 Garage-Attached 540 Valuation: Building Height: Occ. Status: Primary Basement: cov porch 64 Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft. Front: E 70.0 Ft. Shoreline: 80.0 Ft. Water Body: Case Inlet Rear: W 68.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 10.0 Ft. Shoreline Desi g.: Urban Year: Serial No.: Side 2: S 10.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KKK 12/19/200 $846.14 S22005000 Hosebibs 5 Fireplace 1 Planning Review Fee KKK 12/19/200 $155.00 S22005000 Kitchen Sink 1 Ventilation Fan 8 Building State Fee DLC 5/9/2006 $4.50 S22006000 Lavatories 4 Dryer Vent 1 Building Permit Fee DLC 5/9/2006 $1,335.35 s22006000 Showers 1 Mechanical Fee DLC 5/9/2006 $128.20 S22006000 Water Closets (Toilets) 4 Mechanical Base Fee DLC 5/9/2006 $23.50 S22006000 Water Heaters 2 Plumbing Fee DLC 5/9/2006 $124.00 522006000 Bath Tubs 3 Plumbing Base Fee DLC 5/9/2006 $20.00 S22006000 Clothes Washer 1 ADJUST--Plan Check Fee DLC 5/9/2006 $21.84 S22006000 EH Plan Review TW 5/15/2006 $75.00 S22006000 Total $2,733.53 BLD2005-02134 Please referto the following pages for conditions of this pen-nit. 1 of 5 { CASE NOTES FOR BLD2005-02134 CONDITIONS FOR BLD20 0 5-02 1 34 1) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State ashington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in per mi vocation. X 2) All cha es to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordi a or regulation, must be reviewed and approved by Mason County prior to construction. X ' 3) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. f documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be char nd shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 4) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with th international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspeddr shall be made prior to requesting additional inspections. X - 5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to re q st a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mao ounty ordinances and building regulations. X 6) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access load. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where suc X 's connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. BLD2005-02134 Please referto the following pages for conditions of this permit. 2 of 5 7)• Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be I ted within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your projqjc X 8) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertic concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 9) Wate ality is not to be degraded to the detriment of the aquatic environment as a result of this project. X 10) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action fgr a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder ve prevented action from being taken. No more than one extension may be granted. X ' 11) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Officia The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or rem' I of approved documents will result in failure of required building inspections. X 12) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building De ment prior to any further inspections being performed or approvals granted. X 13) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the kirisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting insp , ions.. 14) Pressui,6 treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, Conn rand flashing. Install metal connectors approved for contact with the new types of pressure treated material. X BLD2005-02134 Please refer to the following pages for conditions of this permit. 3 of 5 15), All property lines shall be clearly identified at the time of foundation inspection. X 16) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There c7re potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800- 7-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X ' 17) App d per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 18) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approv I will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildi �rtment prior to any further inspections being performed or approvals granted. X 19) Temporary erosion control measures must be implemented to prevent water qua �degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. Xf,- 20) Washington State Energy Code Compliance has been approved using the following: Heat Ty e: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight(Max U-Factor):0.58, Doors pe/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X 21) Per 2003 IRC - SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimup wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BAST IND SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X 22) Per 200 IRC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accocwith the applicable provisions of this section and the manufacturer's installation instructions. X 23) This el is located in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X 24) This el is located in a smoke management zone. Please contact a fire warden at (360)427-9670 ext. 459 for further information. X 25) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure the r ctures meet the setback conditions listed. X BLD2005-02134 Please referto the following pages for conditions of this permit. 4 of 5 26) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Appr Site Plan"to ensure these structures are shown and meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described propee and structure for revi w and inspection. OWN ER OR AGENT:(�i vluc� -- DATE: BLD2005-02134 Please referto the following pages for conditions of this permit. 5 of 5 w Cti7 o ' CONCRETE MECHANICAL MANUFACTURED HOME z CD Date '16 C) Footings f Setbacks Gas Piping � Ribbons Z o Interior Date By Interior-Date B Date By M Exterior Date.Z�,C ey f Exterior-Date B Sot-up INSULATION Point toad f Isolated Footings Rate By Z BG f SLAB INSULATION 0 Date By Data By FIRE DEPARTMENT D Foundation Walls Floors Date By Date >, vG ByT' Data g' 17) DECKS FRAMING Walls Dab By Dale I—�6 yp By i,4c Data 1I/26 bi? 4 /UC PR©PiANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attie Date Type- Date B y ____ {Sate&k By o.w.v // DRYWALL Type: Date 1 G' By Int Brace Wall Date By W Date By FINAL INSPECTION CD W Water Line Fin Sop*ratlon ON m Date By `mil Date By Date � � By Vtu{ O m CA Pass or Request Inspect. c s Type of Insp. Fall Date Date Done By CommentsCD w °' � flootFG+O /lr•�c�lr-ss n s s r-s a 8 7 9- 7 a - :2Ct3 :?.A-* f l 470 cn / /ASS -Jp / /f0`1ho Tim Wpf� Gielr`�j 11 Z2 D ZO VCr o%L�: ss CONCRETE MECHANICAL MANUFACTURED HOME Footings !Setbacks Date By Ribbons Gas Piping Interior pate By Interior-Date By bale By ' t Exteror Date By Exterior-Rate By Set-up L� Point Load l Isolated Footings INSULATION Date By Date By BG!SLAB INSULATION �( Data By FIRE DEPARTMENT 1 Foundation Walls Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwork Attic Type: By Date By Dale By fl wv DRYWALL Type- Dale c Int.Brace Wall Date By v` By Date By FINAL INSPECTION Water Line Fire Seperation Date By Date By Date By Pass or Request Inspect. Type of Insp. Fail Date Date Done By Comments ►t 104 Mason County Dept. of Community Development ent Mason County Bldg. 3 426 W. Cedar P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection November 29, 2007 LINDA KNIPHER 1081 KAMUS DR FOX ISLAND WA 98333 Case No.: BLD2005-02134 Parcel No.: 122162100020 Proiect Description: New SFR The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $64.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $64.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Terry Ryan Mason County Department of Community Development Cc: Property File November 29, 2007 BLD2005-02134 Pertr�4�'�� 3L( MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 7-g'g2 /% 4/- r-t This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been fo nd: Items listed below must be corrected to gain compliance Lz--J%' f yc o s'rc:rs -T.- � v.I u of n r- r k�� 1 1 + !t l. (� l 410<1 1.t1ti IrG ►ln ,�f1 �T � L- vG .,'A 1 c.Q -zc, • �1 �' C. �:t 1.ti n S You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ® Call for re-inspection when corrections are made before continuing Lj please contact our office Ll Make cor ctions, items will be checked on next inspection regarding possible structural W �. - damage incurred by recent Now `� "natural/man made" ❑This is not a complete inspection disasters.This is NOT a CORRECTION NOTICE. Date 5'//L� Department I Inspector ■ ,O* -� N* ,-,T , rl�, O ' ' THI , T'A"moff Permit# �S` �2 � y MASON COUNTY BUILDING III 426 W, CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 2.S- 4 d l This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance / /-✓ "c L C /f/ �-- 1a6v 2- 7 f v 1�2 lie v d2 IZZ1222 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FUR ER WORK ❑ Call for re-inspection when corrections are made before c ntinuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is NOT a Date - Department /'/ e.,^ CORRECTION NOTICE. Inspector , viiiL lo N� ,sT P -�I �4 ' THI 'mb, TA* mw Permit# MASON COUNTY BUILDING /it 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Locationz- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance `"�✓� i J 1 c 36.1 { cc You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection I disasters.This is NOTa AS-Date ' —ls '" Department CORRECTION NOTICE. Inspector Do $ Nt ,#T , M9 ,#V ' THI qb, TAG