Loading...
HomeMy WebLinkAboutBLD2002-01658 SFR, Deck - BLD Permit / Conditions - 5/22/2003 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 �- ) y Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2002-01658 OWNER: DAN DUBIAK RECEIVED: 12/30/2002 CONTRACTOR: LICENSE: EXP: ISSUED: 5/22/2003 SITE ADDRESS: 561 E QUAIL HILL RD BELFAIR EXPIRES: 9/22/2004 PARCEL NUMBER: 122094390150 LEGAL DESCRIPTION: TR 15 OF SW SE NOW PARCEL B OF SP #379 AF#343351 561 E QUAIL HILL RD BELFAIR PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE, DECK HWY 3 TO ALLYN, TAKE 302 NORTH BAY RD PAST COULTER CREEK AND FISH HATCHERY TURN UP QUAIL HILL RD 2ND TO LAST HOUSE ON LEFT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: 4 Occ. Group: R-3 Lot Size: Deck: 360 Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:2,100 Garage-Attached 480 Valuation: Building Height: 28 Occ. Status: Primary Basement:2,050 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: SEPA?: Model: Width: Ft. Rear: Ft. Slope: Ft. Shoreline Desi Side 1: Ft. g.. Year: Serial No.: Side 2. Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KLW 12/30/200: $908.02 1670 Hosebibs 3 Gas Outlets 2 EH Plan Review ADR 1/3/2003 $75.00 B12003 Kitchen Sink 1 Ventilation Fan 4 Planning Site Inspection RAM 1/31/2003 $70.00 Bi2oo3 Lavatories 2 Propane Stove 1 Public Works Review RAM 2/10/2003 $36.50 612003 Showers 1 Boller 1 Building State Fee MRG 2/18/2003 $4.50 B12003 Water Closets (Toilets) 3 Mechanical Fee MRG 2/18/2003 $61.70 B12003 Water Heaters 1 Mechanical Base Fee MRG 2/18/2003 $23.50 B12003 Bath Tubs 2 Plumbing Fee MRG 2/18/2003 $84.00 B12003 Clothes Washer 1 Plumbing Base Fee MRG 2/18/2003 $20.00 B12003 Building Permit Fee KKK 2/21/2003$1,396.95 6120o3 Mechanical Fee CMH 3/25/2004 $10.65 B12004 Total $2,690.82 BLD2002-01658 Please refer to the following pages for conditions of this permit. 1 of 4 rASE NOTES FOR B LD2002-01668 CONDITIONS FOR BLD2002-01668 1) This applicati Sort is�tbiect to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-64 9 . The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) The use, handling and storage of hazard ' t�i Is or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval G of the Mason County Fire Marshal. X r 4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work whic ay ffe� your project. X 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X L 6) The approval of this project is subject to the recommendations and specifications ou4Viae4 in the attached geotechnical report or assessment. Structures and /or land modifications (grading, cuts, fills, etc.) required in the geotechnical r tq/ rt/ s ssment, may require a seperate permit. The geotechincal report/ assessment shall remain attached to the approved building plans. X 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Departmenvpnorto further inspections being performed or approvals granted. X BLD2002-01658 Please refer to the following pages for conditions of this permit. 2 of 4 8) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contract a� to ost the address on site prior to requesting inspections. X—- �--rT 9) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site f r the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 10) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will no be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Buildip Dc Oart ent prior to any further inspections being performed or approvals granted. X_/ , 11) In buildings Qf�usually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion X r from o 9tsi�d in accordance with the Uniform Mechanical Code. J 12) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged Ld2ll q� collected by the Building Department prior to any further inspections being performed or approvals granted. X 13) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy nfd. es� in permit revocation. X � 14) Installation of heating equipment in single family residences shall meet the requirement of the current WSEC. The furnace to be installed shall not exceed 200% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher or rated 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with m t rs installation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X 15) All changes to,,'approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance o reguat' n, must be reviewed and approved by Mason County prior to construction. X '' BLD2002-01658 Please refer to the following pages for conditions of this permit. 3 of 4 16) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector sj"made prior to requesting additional inspections. X- 17) All property lines shall be clearly identified at the time of foundation inspection. X 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being Xn-comp ilNlVlason County ordinances and building regulations. 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hold er'fifv�prevented action from being taken. No more than one extension may be granted. X O 20) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, property line, public way, possible source of ignition (electrical outlets, electrical fixhitures ompressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. If a propane tank is exposed to probable vecular d ge, protective bollards must be installed. X 21) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installat on eq irements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X � 22) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspe�b7 the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall nofr a ntil the final inspection has been performed and approved by a Mason County building inspector. X 23) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such reg,0z4ions primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think such featur s ist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended fora period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proofof continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the ab descr d property and structure for review and inspection. OWNER OR AGENT: �/ / 2, (/Li ?�`��(—� DATE: _ 1 =J BLD2002-01658 Please refer to the following pages for conditions of this permit. 4 of 4 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMPtUNITY DEVELOPMENT Phone: (360)427-9670, ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2002-01658 OWNER: DAN DUBIAK RECEIVED: 12/30/2002 CONTRACTOR: LICENSE: EXP: ISSUED: 5/22/2003 SITE ADDRESS: 561 E QUAIL HILL RD BELFAIR EXPIRES: 11/22/2003 PARCEL NUMBER: 122094390150 LEGAL DESCRIPTION: TR 15 OF SW SE NOW PARCEL B OF SP#379 AF#343351 561 E QUAIL HILL RD BELFAIR PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE, DECK HWY 3 TO ALLYN, TAKE 302 NORTH BAY RD PAST COULTER CREEK AND FISH HATCHERY TURN UP QUAIL HILL RD 2ND TO LAST HOUSE ON LEFT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: 4_ - Group: R-3 Lot Size: Deck: 360 Type of Work: NEW Fire Dist.: 5 No. of S o Qss° ��)[�B-C. Load: Building:2,100 Garage-Attached 480 Valuation: Buildi Occ. Status: Primary Basement:2,050 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Rear: Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KLW 12/30/200: $908.02 1670 Hosebibs 3 Furnace<100K 1 EH Plan Review ADR 1/3/2003 $75.00 B12003 Kitchen Sink 1 Ventilation Fan 4 Planning Site Inspection RAM 1/31/2003 $70.00 bi2008 Lavatories 2 Dryer Vent 1 Public Works Review RAM 2/10/2003 $36.50 612o03 Showers 1 Building State Fee MRG 2/18/2003 $4.50 B12o03 Water Closets (Toilets) 3 Mechanical Fee MRG 2/18/2003 $61.70 B1MM Water Heaters 1 Mechanical Base Fee MRG 2/18/2003 $23.50 B12003 Bath Tubs 2 Plumbing Fee MRG 2/18/2003 $84.00 B12003 Clothes Washer 1 Plumbing Base Fee MRG 2/18/2003 $20.00 B12003 Building Permit Fee KKK 2/21/2003$1,396.95 B1 mm Total $2,680.17 BLD2002-01658 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR B LD2002-01668 CONDITIONS FOR B LD2002-01668 1) This applicatio ubfect to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 'i _ 1 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-�47�-QN2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X toy 1" 3) The use, handling and storage of hazardo fials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X I" 4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work whicf� y affect your project. X 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X !� 6) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and /or land modifications (grading, cuts, fills, etc.) required in the geotechnica p / assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Depayt�rtfe�t prior to any further inspections being performed or approvals granted. X BLD2002-01658 Please refer to the following pages for conditions of this permit. 2 of 4 8) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and • legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contretor f , o post the address on site prior to requesting inspections. X [—� 9) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building in spe o X 10) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the&�� partment prior to any further inspections being performed or approvals granted. X 11) In buildin f unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air fro ou ic" accordance with the Uniform Mechanical Code. X / 12) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged an t;k" be collected by the Building Department prior to any further inspections being performed or approvals granted. X (4 13) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County d the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occu an y yvould result in permit revocation. X l 14) Installation of heating equipment in single family residences shall meet the requirement of the current WSEC. The furnace to be installed shall not exceed 200% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher or rated 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with iu turers installation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X _ 15) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County Xrdina e regulation, must be reviewed and approved by Mason County prior to construction. BLD2002-01658 Please refer to the following pages for conditions of this permit. 3 of 4 16) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspe rrss alb made prior to requesting additional inspections. X �_� 17) All property lines shall be clearly identified at the time of foundation inspection. X 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure t request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non- o pNant with Mason County ordinances and building regulations. X 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the per h Idtiave prevented action from being taken. No more than one extension may be granted. X f lT This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidenn f continuation of work is a progress inspection within the 180 day period. Fina inspection must be approved before building can be occupied. OWNER OR AGENT: � � �rZ L�Gt ��iC� % l — DATE: Z O BLD2002-01658 Please refer to the following pages for conditions of this permit. 4 of 4 W r ' 0 o CONCRETE MECHANICAL MANUFACTURED HOME 0 N Footings f Setbacks Date B y Ribbons 0 Date By Gas Piping Date B y 00 Foundation Walls Date B y Set-up D ate B y INSULATION Date B y B G f Slab Insulation Floors Final D ate By Date B y Date B y FRAMING Walls FIRE DEPT Date By Date B y Date B y PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING D.W.V. Date By Date By FINAL INSPECTION Water Line Date By Date By Date By ............ ...........................<...........................:;.......::. cn CD 0 St CD 0 0 � d `m rco co d � o N a O 0 N c *01 i � d Cn 3 0 �j�tig � S �f�yJ �s�ll v� �✓���kJ�i _ � �� 'tvTl rva —"*:V -7V'7 -W 22 _W (2 I ssv �� -�/ -- � o — � �'�10 •' WW _ p u o -)701 VfTO oe Aq Aq 0jep Aq �9 Z eleP� � Q NO IVNU aura laleM Q///J V Aq ---- - ejep Aq 9 �2�olep JNIIIVN QaVOCI IVM WAVO Aq — elep q ��Z ✓ elep ,A -1"Z?`-,Qf1 Wor^punol0 d3FUO O-W f 19�;/ _.ov7 O igmId ---- Aq ejep Aq elep Aq AO 2? l elep Aq ld30 a ep -- se p A9 _� JNIYYV, q ejep Ieuij S1001_j uogein 8y 1 � Aq ejep NOLLYInSN1 (q l alep do ieS Aq olEp TIMM uonepum-J Aq ejep Bttfcl!clJ �q gf_ , ejep auogcm el pp v J :PerleS-scugomi- ! 3NIOH 3I180W IVOIN"O3w 3-I3W-Nc7O�! Building Permit # 02 -a/<9S X' MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location &-9191t XZ5- / QUA/C- h1/LC- /0 This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 7,yr4T You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection OK to �X e1d J-,�'� 'G� _ ❑ This is not a o6mplete inspection Department Date "��-� Inspector % . no * NOT MOOV THIlook Tmk Permit # fi2 /cs ' MASON COUNTY 4. BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 1�)j�) This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance ��.� �='!T%C=.✓/j'� _ :,ram'/�•iT You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to❑ This is not a complete inspection Department CJ Date ���� �` Inspector moos TOOT MOOS/ THI T ' u gLL7).200- 014068 Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 ORRECTION NOTICE %A u (DAN Job Location 561 EA-5T Out, L- N&L- CXui?1Ak This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance I EMl7V E 5>4mAgcs 'F rvrv,- VLL L a a- R nacE� A}va '4agL.tA e-F F"or�_ S«f3 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing 0 Make corrections, items will be checked on next inspection ❑ OK to r QUE ❑ This is not a complete inspection Departments .BL� Date I%D I tcW Inspector 000 NOT MOOV THI "' T ' Low 1 �►��Idi7ig Permit It �� MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location �L-I F, Qom,I P j I Rd. u ixio� IL This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance w.t4j" Z'r �� 'H�e�� `�►-f Itt�� ctmy .�e V'J r!>>^1u- bIGArc-1 11 K S W I - Ct S Skk44ILeyz lkt. Nel fOV 1 li u tej C,j a I,.tV to V.L_ J'�'f ✓� �. C— c,,I t -'f cZs in ' >M i e to :a H a KoL o&4-t t4 t 4 Cvw� G 1 '1 U 1T o eyd .� You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK 0 Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to T-This is not a complete inspection ��;,�� -� Department Date 42 Zl�l JUIC Inspector ■ OU No OT Mo *V THI ' , T ' IP14Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar P.O- Box 186 (360) 427-9670 Local (360)482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection November 08, 2007 DAN DUBIAK 481 NE OLD BELFAIR HWY BELFAIR WA 98528 Case No.- BLD2002-01658 Parcel No.- 122094390150 Proiect Description- RESIDENCE, DECK The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International _ Building Code and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $64.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $64.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Terry Ryan Mason County Department of Community Development Cc- Property File November 08, 2007 BLD2002-01658 In.formation F R 39043 N .To Build 4n 110 oft -as • Cvn.sdH,g • T-wU-g SEATTLE DIVISION ® TACOMA DIVISION ❑ PORTLAND DIVISION 3257 16TH AVE.W. 10025 SO.TACOMA WAY,SUITE HI 6032 NO CUTTER CIR.SUITE 480 SEATTLE,WA 98119 TACOMA,WA 98499 PORTLAND.OR 97217 (206)282-0666-FAX (206)282.0710 (253)589-1804-FAX(253)589.2136 (503)289-1778'FAX(503)289-1918 CLIENT Dan Dubaik _ PROJECT NO. 742-30326 DATE December 16,2003 ADDRESS 481 NE Old Belfair Hwy PERMIT NO. W.O. 66187 Belfair,WA 98528 CITY Belfair ENGINEER ATTENTION Mr.Dan Dubaik ARCHITECT P.O. NO. CONTRACTOR PROJECT SFR- Dubaik-Belfair JPROJ.ADDRESS 561 Quail Hill Rd FIELD REPORT PSI ON SITE FOR CORE DRILLING AS REQUESTED. DRILLED CORES IN EXTERIOR WALLS 6"THICK AT LOCATIONS CALLED OUT BY CUSTOMER. 1: EAST WALL CENTERED BETWEEN WINDOWS 24"ELEVATION. 2: EAST WALL CENTERED BETWEEN WINDOWS ELEVATION 24"APPROXIMATELY. 3: EAST WALL NORTHEAST CORNER ELEVATION 20"APPROXIMATELY. 4: NORTH WALL BY NORTHEAST CORNER ELEVATION 24"APPROXIMATELY. SEVERAL CORES BROKE IN TWO WHILE DRILLING. TEST=COMPRESSION. EQUIPMENT IDENTIFICATION AND S/N#: COPIES TO: INSPECTOR: DATE: ITEMS INSPECTED TO DOUGLAS OTTO December 16, 2003 APPROVED PLANS ARE: x CLIENT CONTRACTOR FIELD CONTACT: DATE: ENGINEER x BUILDING DEPT. CONFORMING �X ARCHITECT SUPPLIER NONCONFORMING 'This report is provided for the information of the client only. The reproduction of this report,by any method,and its transmittal to a third parry,by any means,except in full,without the full permission of Professional Service Industries.Inc.,is prohibited-' NAME O N OFF ST OT MILES 'This certification attests to the accuracy of the results obtained from the actual test performed and/or observations made within the defined scope o the work. Certification shall not be construed to represent an inspection,approval or acceptance of other associated work or a warranty of desgn o D.OTTO 8:00 1 3:30 160 workability of the specification requirements.' TOTAL HOURS Certified Report by t/ Professional Service Industries: )?""Ca's.. Bode, Date 0ecembeor 31, 2003 %\� AR Z � Information v C R 31626 Build On r I SEATTLE DIVISION ® TACOMA DIVISION *.y+� f 1 .- PORTLAND DIVISION 3257 16TH AVE.W. 10025 SO.TACOMA WAY.SUITE H1 6032 NO.CUTTER CIR.SUITE 480 SEATTLE.WA 98119 TACOMA,WA 98499 PORTLAND,OR 97217 (206)282-0666-FAX (206)282-0710 (253)589-1804'FAX(253)589-2136 (503)289-1778 FAX(503)289-1918 CLIENT Dan Dubaik PROJECT NO. 742-30326 DATE December 16, 2003 ADDRESS 481 NE Old Belfair Hwy PERMIT NO. W.O. 66187 Belfair,WA 98528 CITY Belfair _ENGINEER ATTENTION Mr.Dan Dubaik ARCHITECT P.O. NO. - -CONTRACTOR -- - ---- - -- PROJECT SFR-Dubaik-Belfair PROJ.ADDRESS 561 Quail Hill Rd COMPRESSION TEST RESULTS SAMPLE I.D. SIZE(IN.) AREA(SQ.IN.) DATE TESTED AGE AT ULTIMATE STRENGTH CHECKED FRACTURE TEST LBS. PSI TYPE A 2"X 4" 2.37 12/17/03 UNKNOWN 6660 2820 LG B 2"X 4" 2.38 12/17/03 UNKNOWN 4680 1970 LG C 2"X 4" 2.41 12/17/03 UNKNOWN 6210 2580 LG D 2"X 4" 2.38 12/17/03 UNKNOWN 6570 2760 LG AVERAGE=2530 SAMPLE AND TESTED FIELD SPECIMENS SLUMP SAMPLING AIR TEMP BREAK NEO CAP OTHER IN ACCORDANCE WITH: ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM C-31 21 C-143 23 C-172 El C-231 ❑ C-1064 2 C-39 0 C-1231 0 TIME,TEMP.& DATE MIXING DESIGN SAMPLE WEATHER CAST PLANT STRENGTH TYPE PROPORTIONS: CEMENT C'SE AGG. FINE AGG. WATER ADDED ADMIXTURE ADMIXTURE ADMIXTURE TYPE OF CEMENT I II CONC.TEMP. SLUMP ins. AIR % QUANTITY Cu Yd. TRUCK TICKET# SUPER PLASTICIZED SLUMP MIX# POUR LOCATION AND NOTES DATE RECEIVED: CONCRETE WALL CORES 2"X 4". COMPRESSIVE STRENGTH. EQUIPMENT IDENTIFICATION AND S/N#: COPIES TO: INSPECTOR: DATE: ITEMS INSPECTED TO x CLIENT CONTRACTOR DOUGLAS OTTO December 16, 2003 APPROVED PLANS ARE: ENGINEER x]SUPPLIER BUILDING DEPT. FIELD CONTACT: DATE: ARCHITECT CONFORMING NONCONFORMING 'This report is provided for the information of the client only. The reproduction of this report,by any method,and its transmittal to a third party.by any NAME ON OFF ST OT MILES means,except in full,without the full permission of Professional Service Industries.Inc..is prohibited- 'This certification attests to the accuracy of the results obtained from the actual test performed aridior observations made within the defined scope of I work. Certification shall not be construed to represent an inspection,approval or acceptance of other associated work or a warranty of design or workability of the specification requirements.' / TOTAL HOURS Certified Report by v Professional Service Industries: g'-wP.ui.S. BDdPi ` Date 91, 2009