Loading...
HomeMy WebLinkAboutBLD2016-00476 SFR - BLD Permit / Conditions - 1/3/2017 Inspection Line (360)427-7262 "SIN, Cot,rF MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County 615 W Alder St Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2016-00476 OWNER: PIONEER BUILDERS RECEIVED: 5/26/2016 CONTRACTOR: LICENSE: EXP: ISSUED: 1/3/2017 SITE ADDRESS: 141 E CARDINAL CT ALLYN EXPIRES: 7/3/2017 PARCEL NUMBER: 122085111007 LEGAL DESCRIPTION: LAKEWOOD PLAT I BILK: 11 LOTS 7-9, 30-32 TGW N1/2 OF VAC MAPLE ST& S1/2 VAC FIR PROJECT DESCRIPTION: DIRECTIONS TO SITE: TWO STORY NEW SFR WITH ATTACHED GARAGE ON E CARDINAL CT IN ALLYN, WA General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3, U Lot Size: Deck: 136 Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: 7 Building:1,560 Garage-Attached 623 Valuation: $ 205,576.49 Building Height: 27 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 26.0 Ft. Shoreline: Ft. Water Body: c Rear: N Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 7.5 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 7.5 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 3 Heat Pump 1 Plan Check Fee JBN 5/26/2016 $ 1,031.78 S2201600000001 Lavatories 4 Ventilation Fan 4 EH Plan Review JBN 5/26/2016 $205.00 S220160000000( Bath Tubs 1 Propane Tank 1 Planning Review Fee JBN 5/26/2016 $205.00 S2201600000001 Showers 1 Gas Outlets 3 Address Fee JBN 5/26/2016 $ 173.50 S220160000000i Water Heaters 1 Propane Stove 1 Building State Fee SLC 6/23/2016 $4.50 S1201700000001 Clothes Washer 1 Exhaust Hood 1 Building Permit Fee SLC 6/23/2016 $ 1,587.35 S1201700000001 Kitchen Sink 1 Dryer Vent 1 Mechanical Permit Fee SLC 6/23/2016 $228.60 S1201700000001 Dishwasher 1 Mechanical Base Fee SLC 6/23/2016 $28.50 S1201700000001 Hosebibs 2 Plumbing Permit Fee SLC 6/23/2016 $ 119.30 S1201700000001 Plumbing Base Fee SLC 6/23/2016 $24.70 S120170000000( Total $ 3,608.23 BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 1 of 8 CASE NOTES FOR BLD2016-00476 CONDITIONS FOR BLD2016-00476 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-8 647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. XA 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 3) 0 ner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the ' corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or rm;val of approved documents will result in failure of required building inspections. X 5) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X 6) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X Yk BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 2 of 8 7) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 3D- DUCTLESS HEAT PUMP WITH ZONAL CONTROLS (1.0 CREDITS). CTRIC HEAT PUMP WATER HEATER WITH A MINIMUM EF OF 2.0 (1.5 CREDITS). X !:AN 8) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in %<or%2 sheets. The Mason County Permit Center will also have some available. 9) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R4�04�1. X lQ_M 10) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) 11) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 3 of 8 12) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion -�ffrom outside in accordance with the international codes. X U IV 13) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and approved by Washington State Labor& Industries must be available on-site during the inspection. The Mason County Building Inspector will inspect the following: Verify that the system is installed in accordance with manufacturer specifications; The inspector will check to make sure that the exterior unit is permanently installed and supported, the exterior unit complies with required setbacks to property lines, fuel tanks are located at least 10-ft from the system, a source of ignition, all exterior penetrations are properly sealed, condensate lines are installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location outside of the foundation, copper refrigerant lines are insulated with '/2" thick continuous closed-cell foam insulation or better, indoor units are located at least 3-ft from smoke and carbon monoxide alarms, and that modifications made to the structure, to install the unit, does not affect existing structural members. X V 14) A separate inspection in addition to the inspections required in IBC, Section 110 shall be required in accordance with the 2012 IBC, Section 1707.11.2. The additional inspection is required when shear wall fastener spacing is required to be less than 4-inches. The shear wall schedule shown on sheet S 1.0 designate walls type SW R with fastener spacing less than 4-inches. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the engineer of record (EOR), or an authorized representative of the EOR. The special inspectors duties & responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection special inspection reports shall be submitted to the Mason County Building Department, 426 West Cedar St, Shelton WA 98584 and also available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing inspections. X 15) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 4� �- 16) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 4 of 8 17) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where suc oads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X �r 18) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be r ed and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 19) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in e�rtnit revocation. X 20) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181Aand shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. X:4 BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 5 of 8 21) The placement of buildings and structures on or adjacent to slopes steeper than one unit vertical in three units horizontal (33.3% slopes) shall conform to the International Residential Code Section R403.1.7 for descending or ascending slopes. Alternate setbacks may be approved subject to approval of the building official based upon the investigation and recommendations of a qualified engineer licensed in the State of Washington. Such an investigation shall include consideration of material, height of slope, slope gradient, load intensity, and erosion characteristics of slope material. X 22) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ce or regulation, must be reviewed and approved by Mason County prior to construction. 23) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building In ector shall be made prior to requesting additional inspections. X �WM VI 24) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5'from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X tail 25) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be ailed. x �I� 26) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must m et the installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X 27) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not a used until the final inspection has been performed and approved by a Mason County building inspector. X BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 6 of 8 28) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you thin features exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 29) Epoxy grout required and specified on the approved building plans shall require a special inspection. The special inspector shall be the engineer of record or their authorized representative, a WABO Certified special inspector, or certified testing laboratory. In addition a Mason County Building Inspector may perform the inspection provided holes are prepared in accordance to manufacturer specifications that are available on-site during inspection. Special inspectors shall inspect the installation of grouted construction anchors as stated in the manufacturers specifications. An inspection report shall be pr pared and submitted to the Mason County Building Department prior to the framing inspection of the project. X 30) All property lines shall be clearly identified at the time of foundation inspection. 31) All building permits shall have a final inspection performed and approved by the Matson County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Ma on County ordinances and building regulations. X-21VIA, 32) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hol er have prevented action from being taken. No more than one extension may be granted. X 33) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, con ectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. 34) Retaining walls needed to supportasurFharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X� 35) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. ���n 36) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation drains within 30ft, down gradient of drainfield/reserve area. X 37) On-site septic system final installation approval required prior to temporary/final occupancy. SWG2016-00304 BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 7 of 8 OWNER / BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. 7�6�-" ►11 �7 Signature Date �," Q _�„YL1W OWNER - REPRESENTATIVE - CONTRACTOR Print Name I (Circle one to indicate) BLD2016-00476 Please refer to the following pages for conditions of this permit. Page 8 of 8 BUILDING MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/Ventilation Code Compliance Application Submit with heating/cooling system size worksheet (see instructions #4) Owner: Parcel#: Type of project: 1 o - -on SfR Total Sq. Ft. 15 Floor : N floor: Heated Basement: of heated area:: -7 3 c6 312 Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace Wbuctless Heat Pump O Boiler, specify fuel type: O Other: Specify: µ✓Prescriptive Option Table R402.1.1 Compliance Method µ Component Performance, R402.1.3— Calculation worksheets required Check one:: µ Other (Specify): Check one µ Whole House Ventilation system µ Whole House Ventilation µ Other, Ventilation using exhaust fans&window or Integrated with a Forced Air describe: System `/ wall fresh air vents(M1507.3.4) System (M1507.3.5) Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/index.php. Additional Energy a) Description: Small dwelling units with less than 1500 sq. feet of heated or cooled Efficiency space and less than 300 sq. ft fenestration (see definition below) or additions to an Requirements existing building that is less than 750 sq. ft. of heated area. To use this option Energy credits complete a window schedule in order to verify that the fenestration area does not exceed 300 sq. ft. Fenestration is defined in the IECC as skylights, roof windows, required: vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. —0.5 points 1. S b) Medium dwelling units not includes in a) above, or b) below— 1.5 points c) Large dwelling unit is a dwelling unit that exceeds 5000 sq. ft. of heated or cooled floor area. —2.5 points. Describe Energy Credit Option(s): Using Option number(s): Planner: Grace � Rebecca RECEIVED MASON COUNTY PLANNING INTAKE CHECKLIST t,',AY 2 6 2016 Owners Name: P-Q n e ter- Date: 615 W. ,ruder Streit Project:NP,� 2 -5�7, �„ SFP, 6402&6' Commercial ?: yes Sit Plan: 00 f 7(V North Arrow Property Dimensions: x U(-) Irregular Shape ? yes Streets and Driveways shown .eT Road Frontage Name: Cat' (-d C 7(-- 2All Existing Structures Shown with setbacks and use. -2'Identified Surface water(streams,ponds, shoreline,wetlands,natural/historic drainage, defined drainage) )2rI opography (slopes) o-Minimum Structure Setbacks (direct'on/setback): F: S / -Z& R:T/ \0 S1 �7-7 / 7S S2 W / 7, S g.Utility and Drainage Easements: yes no (if yes enter condition #5022) ,p. ther Easements Accessory Appurtenances: ropane tank eat pump )Does site plan show landings a XVariance applied for: yes ® Parking spaces allotted: es no a-£Access Permit Needed (add condition #0010) cue Access Permit needed (add condition #0020) Tanning conditions: #5019 and #700 ,e'Are there any impediments (dogs/gates) that may restrict access to your site? yes no ❑ If yes, do we need appointment? yes no ( I .O Is site clearly marked? ess Name Other ZONING UGA'S LYNBELFAIR/SHELTON ural LAND DESIGNATIONS GC PF R-1 R- RC 1 RR 2.5 AGRICULTURAL POS FR - -1R RC 2 R 5 LTCFL BI GC-CI - RC 3 IN-HOLDING HC L R-5 RT RMF RR 20 TRIBAL T R-10 RT/RTC RNR MB P BP vC RAC NR Critical Areas: (streams,ponds, shoreline,wetlands& steep slopes) Shoreline Designation: �N/A ❑ Urban ❑ Rural ❑ Conservancy ❑ Natural Water Body: SEPA: yes no untgAn Flood Plain: yes no urXbown Map # Aquifer Recharge: yes no uf�nqwn Map# Tags/Cases: RLC/SPI: 6 year Reforestation: yes no Eagle Nest Tag: yes no �' Other/North Bay Sewer: yes n RECEIVED a n- MA 2 6 2016 615 W. Alder Street PLAN ING 50.00' 5. DETENTION POND EASEMENT o o ------ ---- .------------ 0 0 D-BOX p — — — — - - DRAINFIELD ° N - - - - - - APPROVED DN COUNTi Y DCD PLP,NNING CD ° — — — — — — f 'ILAN REQUIRED TO BE ON SITE 0 SEPTIC,TK . jANGES SUBJET TO APPROVAL - - Date(P Zd 145) .s �` 11 O N?� I Will- s � ALL SETBACKS ARE JIEASURED FS Q FROM THE FUR HEST PROJECTION OF THE, BUILDING T GARn I NAL GT. + SITE PLAN SCALE: I"=20'-O" LOT 54 5ELWOOD awl ' elc J D CUSTOM JA1' HAUGEN, VES 1 GNER HOME PORT ORGHARP, AA nESI GN (208) 0121-4856 A 51TE PLAN FOR PIONEER 5U 1 L=)ER5 INC. 0426 Name?1,orge- C. Parcel# ►aaQ46- Sl-lI 00`4 BLD# Mason County BUILDING Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) >a000 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner contractor(circle one)Date: �'�•,'16-/� If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name 9 ;onI er In; I L5, I Olt. Parcel#_ 1 O�5 -tr) _ 1/OP-7 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Storrnwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/indexltm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) *44 The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 M 1:P 0 Box 1850, Shelton WA 98584 Phy ical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St,Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X !� ,//� Owner gent/ ontractor(circle one)Date: !,d Page 2 of 2 BUILDING♦ rA MASON COUNTY PERMIT NO. 6LD DEPARTMENT OF COMMUNITY DEVELOPMENT CO11 BUILDING•PLANNING•FIRE MARSHAL O-I 7C0 WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 'rl�t�c7 5�r� BUILDING PERMIT APPLICATION RCEIJUN � � OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: 3�08,,0,r 5T' . NAME: s,,, - 61 J. Alder Str set MAILING ADDRESS:70 goh 1044 MAILING ADDRESS: CITY:'?,„i (7�. STATE: VA ZIP: CITY: STATE: ZIP: PHONE: '%0 ff,-+4 3f I CELL: PHONE: CELL: EMAIL: ,p;o Lam,,;1 olw�,_,,c ���,�A_co... EMAIL : L&I PEG#rj'/ON C K E EXP. PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): SITE ADDRESS 1H 1 �- C,, ,, .I C i CITY A tl DIRECTIONS TO SITE ADDRESS IS PROPERTY WITHIN 200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO [g� TYPE OF JOB: NEW W ADDITION ❑ pJALTERrrA�TION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) N�jwl 5 f 2 IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS 2 l-p DESCRIBE WORK SQUARE FOOTAGE: 1ST FLOOR 1 0 sq.ft. 2ND FLOOR 5 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK 1AV tWq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. ATTACHED DETACHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED ❑ MANUFACTU D HOME INFORMATION: *4 COPIES OF THE FLOOR AN MA M EL YE LENGTH WIDT BEDROOMS BATHS SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSP TION.I �,TIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. ignature of Applicant Date X �124 V4 6-/' OWNE EPRESENTATIVE ONTRACTOR tint Name E) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL c �rA MASON COUNTY BUILDING PERMIT NO.LLD20)LO '— DEPARTMENT OF COMMUNITY DEVELOPMENT ���� BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext.352 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 :5 PLUMBING & MECHANICAL PERMIT APPLICATION RECEIVED OWNER INFORMATION: CONTRACTOR INFORMATION: JUN 0 2 2016 NAME: '?)r•,r L,r '$h`.I w1_ )vet. NAME: me t MAILING ADD SS ��y MAILING ADDRESS: of CITY:'?*,A Q,A„o : ?p:a STATE:ZIP: CITY: STATE: IP: PHONE: 1 CELL: PHONE: CELL: EMAIL: 1 c EMAIL : L&I REG# jptl E EXP. PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): LEGAL DESCRIPTION(ABBRE VIA TED): SITE ADDRESS: )41 Z Cr. ,\-,h I (�TE}j(�,,, CITY: DIRECTIONS TO SITE ADDRESS: TYPE OF JOB NEW -/ ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS—1 ST FLOOR / 2No FLOOR ✓ BASEMENT GARAGE ,/ OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_ Toilets 3 Type of Unit No.of Units Fees Bathroom Sink H Furnace Bath Tubs I Heatpump 1 Showers 1 Spot Vent Fan 4_ Water Heater I Propane Tank 1 Clothes Washer l Gas Outle _ '3 Kitchen Sinks l Woo as ellet Stove 1 Dishwasher Kitchen-1 xhaust Hood I Hosebibs Dryer Vent ( Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. / Signature of Applicant Date X \ ham/ Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS` BUILDING DEPARTMENT LG (® L PLANNING DEPARTMENT FIRE MARSHAL