Loading...
HomeMy WebLinkAboutSWG2024-00154 - SWG Application / Design - 4/16/2024 MASON COUNTY 415N BTHELTON:STREET, 0427-97 ,EXT 400 SHELTON:360427-4467,EXT 400 BELFAIR:360-275446],E%T 600 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX:360427-7787 On-Site Sewage System Permit: SWG2024-00154 APPLICANT Joel Roswell Phone: 425-890-6865 Address: 2038 Beverly Beach Dr W OLYMPIA, WA 98502 OWNER GONZALEZ JOE V&THERESA E Phone: Address: 41 E GLENMORGAN CT SHELTON, WA 98584 SEPTIC DESIGNER PAULA JOHNSON' Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER Bamford Septic Repair, LLC Phone: 360-790-2364 Address: 301 E WALLACE KNEELAND BLVD SHELTON,WA 98584 Site Address: 41 E Glenmorgan Ct Primary Parcel Number: 321225000418 Permit Description: Repair: Replace failed sand filter w/Nu Water BNR-500 tank Permit Submitted Date: 04116/2024 Permit Issued Date: 04/18/2024 Issued By: David Anderson Current Permit Fees Paid: $265.00 (additional fees may be required upon mstallatlon of system). Permit Expiration Date: 04/16/2025 (based on date mmspac(onl Permit Conditions: 1 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 4 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OS& PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmentallonsiteloss-inspection-request.php or call: 360-427.9670, extension 400. OFFICIAL USE ONLY WTERERND> Rfc 16Zn24 MASON COUNTY ' 1 K'Fp(D ® COMMUNITY SERVICES PubN� ezIN IC➢mmunMHNNNEmIrnnMtJ HmMI �` /` Ln O .or SWG Ov — 2 r➢ ON-SITE SEWAGE TANK ONLY APPLICATION _ 3 m m PHONE r ppYJ!.i.flT Joel Roswall (425)890-6865 r c 3 MANNGMDNESS-STREET CfIY 6TALEIIPOJCf � m 2038 Beverly Beach Dr W, Olympia,WA 98502 _ m r 611EADDRESS-STREE?CITY➢PCODECID I (a 41 E Glen Morgan Ct,Shetion,WA 98584 NAMEOFDESIGNER PHIX�E I N Arrow Septic Designs, Inc (360)898-2255 NAMEOF INSLALLER PHONE Bamford Septic Repair, LLC (360)790-2364 N I N TYPE OF MORK IAREPvP MNKING ARTIER SOURCE ❑NEWCONSTRUCTIONWIGRAOES NREPAIRIREPLACEMENT ❑ PRNATEINDIVIDUALWELL O PRIVATE TV0RARTY WELL 2 IN 0 PUBLICWATERSYSTEM , CdINNENi(S)TO BE RERACEd INSTALLED (V I � ❑ SEPTICTANK ❑PUMPTANK ❑RV HOLDING TANK BEGRDOMS LOi STLF ' ■OTHER RapbahlkM$BIXI FiIKRUt NUWAMFBNREODMnk 3 .61 acres G O OTHER DETAILS(mb.YNW,,. yt TANK(S)SETPACKCHEGKUST O SURFACING SEWAGE ■EXISTING FAILURE [3 SHORELINE ■ 1NFT+PUSUCICOMMUNITYWELLS x IQ sueMmus ■ SIFT.PRIVATEWELUL SURFACEWATERS.STREAMS,RIVERS 10FT+DRINKIHGNWTER SUPPLY LINES ■PLOTPLAN(REOVIRED) ■TANK CROSS SECTION(REQUIRED) I O ■ PUMP DETAILS(IFAPPLICABLE) [I WAIVERS)N APPLIWBIE) SFT+PROPERTY/EPSEMENT LINES.FOUNDATIONS,FOOTINGS PLOT PUN CHECKLIST I A PROPERTY LINES AND BASEMENTS ■ EXISTING)PROPOSED STRUCTURES ■EXISTING)PROPOSED OSS COMPONENTS AND UNES I ' O WELLS WITHIN IWFT ❑WTSR SUPPLY LINES ■ DRIVEWAYS/PARKING [3 SURFACE VATERS,STREAMS.RIVERS.ETC.. ■ DIRECTION OF SLOPE)CONTOURS O PERIMETEW CURTAIN DRAINS E NORTH ARROW ■SCALE BAR AL 1D 100 DIRECnONSTO SITEAND SITE CONDD10N6'.Ir I IIRN) From downtown Shelton take Hwy 3 toward Belfair, turn (L)onto E Mason Lake Rd, take (L) onto E St. Andrews Dr, turn (R)to stay on E St Andrews Dr, stay (R) onto E St Andrews Dr N, turn (R)onto E Glen Morgan Ct, house is on L at cul-de-sac. OFFICIAL USE ONLY BELOW THIS LINE UPGRADEINTARY 60URCEITENANCgPUMPIl O VOLUNTARY �MAINTENANCEPUMPING [3 BUILDING PERMIT ❑HOME BALE I]LOMPUINT I] COMMENTBICDN TIONS �(1 ly(a�e f�L'�cc�s�,zrl f'11W uy B t�2SaU L APR 1 s ,L;,4 SEW1(1ETANK6 MUBT BE LIBTED UI-0ER DJH•LISL OF REOISTFRED SEWAGE TANKS' TANKS MVSi YEETCUMEM MINIM WMEOWTN FIBERS ANDDDSTOSURFACE.AND INCLUDE AN EFFLUENT FILTER IIFA➢PUCABLEL RECORD DRXMNGANDINSTALUTION REPORT REQUIRED FOR FINA-APPROVAL. 1NBFECTOR 91GNATUR—E GATE APPLICATION EWRATION GATE APPLI APPflOVEDI I63UED BY DATE THIS FORM MAY BE SCANNED ANDAVAILABLE FOR PUBLIC MEW ON THE MASON COUNTYWESSITE REVISEDTKrN1P Arrow Septic Designs 171 E.Vuecrest Dr. Union,WA 98592 April 9,2024 Mason County Department of Health Services 415 N 6th St - Shelton,WA 98584 RE: Joel Roswall Property(Parcel#32122-50-00418)Septic Replacement/Upgmde Dear Inspector: Attached is a repair/upgrade septic design for a property located at 41 E Glen Morgan Ct,Shelton,WA 98584. The existing septic was installed in 2006. The original septic system consisted of a 1,200-gallon 2-compartment septic tank,a 1,200-gallon pump chamber,a 1 Ox36 sand filter and 150 If.(450 s.f)of drainfield. At the last service,it was discovered that the sand filter was ponding.(See report attached.) Upon further investigation, it was confirmed that the sand filter is failed. The sand-filter is to be decommissioned or removed and a NuWater BNR-500 tank is to be added.The NuWater provides Treatment Level B,similar to the sand- filter. The existing 1,200 gallon septic tank may stay as a pre-trash tank if the installer finds it to be in acceptable condition. The existing 1,200-gallon pump chamber will send the pretreated effluent directly to the drainfield. This upgrade also includes adding a new main control panel with a timer,elapse meter and event counter. There are no setback issues to wells or surface water.A full reserve drainfield area is shown. The property owner's contact information is as follows: Joel Roswall 2038 Beverly Beach Dr W Olympia,WA 98502 (425)890-6865 If you need further information,please contact my office at(360)898-2255. Sincerely, Paula J.Jo �d`` /''iPPROVE ,'' Licensed .fie' ewa ,Treatment System Designer APR 18 2024 PAOLA JOY JOHNSON`. 11g fGli .. rxnnEs r MASON COUNTY ENVIRONMENTAL NCALT' DJA �4-(S -Z 4 l 0�-1 /.urn• rro vi OP w Y � 1 C p o Q` H .�• ii' S 1� Y ol 24, S N Oa 6( .�s i i n � _.... • $ •+i.�.a °� ..K.i9.1 AP ROVED s APR 18 2024 s 8F�M \- * f W � -O MASON COUNTY ENVIRONMENTAL H-'I _a DJA cor F If 44 Z \ ft f •�Z 2j• + h V A Ina 01 Y � 7 o` g�yw�c48. A Cn o • ���* J Lp� sl ouJay 'C�,h "<' PAOLP JOY JOHNSON Y n Rev: J gp 4* O Audio-Visual N � Cleanout \ 1 ,.,(,aon Pre-Trash tank \ \ i 3 JSe Gcm"t-' NuWater BNR-500 ATU Tank Chamber se o O Valve Control Box-ET',S�, Oo N � � v oLk r APR 18 2024 t5v�c�. MASON COUN7YENVIROWENTALHEALT4 DJA sc_, c l" - 30 \ �r O [S 3. 'Es foc � S , loAc'cc '�to F 0.9 "N, Jvc., qz-oswq>k 'zo, f)Ce�c9-i 3 2iLL-Sy -0o'ff8 cc, OSr1 sr Lm vPMtlro) DUALtN1RTAPRA1pR wniae�mMPI rwc(n'PI 1R'PVCI WSt1G 86•NUS. AepNE E a• r cauPUND a• &REDUCER rTEE al WC 9 M tl RENRN LINE I it r tvc I DgEBTERCWIMBER CLARIFIER TRASH CHAMBER OPERATwa CMACT^az+OAtIDNe CHAMBER j OPBUnxa WACm:an W Wws RODC CAPACm:aBa GPLLOM IM D6LLONa I rt000 cenAcm:asowttoks � PLCOD:ml wt.i li as se as Sf W T XE1IY 1r gPwaFftarnaR) PIPALEI TO TM1k WALL a. BLVDCE RENBI r � A PParReR PEW STONE-f ENATNEaDR • ROVr" ORCOHPACTEDSAND OVER STONY WE. m&nAu.Anox lx&rRucTwxs APR i 8 2024 1)F vare tardy We win vertical walls to i feot larger loan reek on all aitlee. ,� — vs IL. ry-Q3C, r 2)8 bodom of Ale is wary,metal 7 of..ped eand&w,el - FA[-.' w won screed. �-------,r----- q , 3)Install tank in ceniar dhole.keeping 1 ft vaiE spxe on I �• ) xatoxm all Was. 1 gr As tank is filling j M water,fill in Vdtl space wdh aompxt 1Ypa granular(sanay)sdt free of lerye dumps of day. I iI 6)Install rest l system.&afex risers to atlapters wnh ! I pg fi)Perform watertlghtrvss test in field as require0 by local ))UMnan. I I +r RISER I, 7)Upon approYal b beckfill,Carefully backfill with native I I i I' soils over top of tank. I ID6M1.6161BER II DIGE6IE6 IIReRe®I 8)Final qmM,Me surface le avoid dlanelling surface L______—L__--_--- watartmard tank IDLzsaYIF�' r= AEROBIC TREATMENT TANK DETAIL FOR NUWATER BNR-500 TREATMENT UNIT ENVIRO-FLO, INC. 3/01112 Wastewater Treadrtenf Teton ges P.O.BOX 321161,Ffowood.MS 39232 scat-. ,.. _ 1.4 ft. (877)836-8476 (601)S 716 fax �o www.en ' flo.nef ��NuWa!ter App off'Lf APR 18 2024 <O N COUNTY ENVIRONMENTAL PPP \ OJA � 1 i 1 i i i PARTS UST NuWater NR Assembly Diagram i A.OMLLPORTAEMTOR M.POLY OIFNSERSI B.WS BERW Iff W (3) N.t"PVC(3 IZSECT ) C.WY SPRSEDAOPPTOR X 12 NPT(31 0.1"Wp CAP p.t2'SLIPX t12'NPlAMPTOR P. ilB"CLEAR PvC PVC PIPE INSTIveT PTI0NP15i E t'$IRE£TS 1?'NPT BUSKNG(d) O.1lY' leY /LLLERI E 1?9P ELBOW(3J R.t'PYG PIPE(BY IH5(ALLER) G.1'%1'%t?TEE E.11 PJC PIPE(BY INSTALLER) T.+/Y BARBED ADAPTOR TO 1/6'HPf RI :.2X 1'EUSI U.1?STREET%Yr NPT WISHING R) J Y'SAWTARYTEE V.1?r PVCCOUPLERM % V PVC CROR W Z COUPLER(BY INSTALtERi L.1"COUPLERWINSTALLER) Revised 2/25/12 s o�� L• :41 E GLENMORGAN CT Service Company: Shelton AAA Septic LLC Tea to:321225000418 PO lion 1460 u.. Shelton.WA 98584 360421-6110 Serviced:0110312023 by:Alisha Lovely Submitted 0110612023 by:Alisha Wulf Dumn�:RluRegdrg Jurisdiction ID:321225000418 COMMENTS Rl 11,IC— Replacetl floab aM wamrg m saM filler m tl2in. 01N5123 Chedetl saM fl6er,M1,poMin9 raferted m In,fa3er This tank was not pumped or ser 'ed. APR 18 ?"?4 iM�'r inQurx Mat fJmYJaMo-J r/tlx mM nwyaryvntllM4eYtlx'W.NmxryYtl4�yi�gwrYwwDYnM+wlWarpwbwm_ RelwrtlD:631863 crow Pilaw rePals Donne a<www.DmmeaDv corn Pp 1ort fQ oF-� .41 E GLENMC�C. N C-. Service Company: Shelton AAA Septic Li Tax ID:321225000418 pp Box 1460 u.. Shelton,WA 98584 360-427-6110 Serviced:06107=22 by:Debra Lovely Submitted 07/19/2022 by:Alisha Wulf p.mpinw._Bio-Recydmg Jurisdiction ID:321225000418 COMMENTS Tghtllne hour pump vault to santl filter is broken.rauvng eMuen[watrtlopding the haCkyaN.Also very hash Memkel aural form links. amandeamnuee YES Tank Pumped: 12M Tank Size(Gallons)(Number only,no text): YES Effluent level andve operational Ilmits(II NO explain in comments): 1200 Total GaAons pumped from tank(Number only,no text: EMuent telumi back into tank a0er un in9: NO Tankdepthbdow We inches): YES Atones Risers installatl t retle(N/A'd not eaent): Tank Construction Materiel: tweets Tank CoNon Good: VES M Bafllea in good winditbn WAR not resent): VES Effluent wean cleaned(WA d not presort: VES Effluent auffacing around aite component(.—I...I aketl): NO Tank abandoned after purr m NO Ware re irs made to the Tank or Tank Companion?(OYES explain in wriment: NO Compartment 1 Scum acwmuta0on(Inches,0 otller spei ): 6 Compammert 1 Sludge ewumula8on(Inches,0 oMer specify). 10 Compemmen 2 Scum acomiula0on(Inches,It other apectty): 2 Gore admen 2 Slud a aeeilmula0on Inches,if other specify): 10 Tank Pumped: YES Tank Size(Gallons)(Number only,no text): 1200 Effluent level within operational Innis it NO explain in wmmen): YES Total Gallons pumped from tank(Number only,no text 200 Tank depth belay grade(inchee: Access Risers instlled to qMde(NIA d not present), YES Tank construction Material: Gonerele Tank Condition Good: YES Effluent screen darned NI ifna resent): YES Effluent surfacing amuntlsitco *p Wis WA if not Mocketl : YES ocncwot Pump operating as intended: YES Condos operefirg as intended: YES OMtherm workin es intended YES Tank abatMoned after pum in NO NI matle to the Tankor Tank Components?iff YES explain in wmmenb: NO Corn Roman i 3wm aF ulauon Inches,B other spec' ): 2 Co. i 5lutl a aocumumon Inches.a other spec' pp�q+pp�pp 'T S 10 8 f� a, APR 18 "24 m.mc<+meLw.wnss<r.,u.ha�awew....v<r+*m,�m.a..ww.mno�`wraa:.mmsai+r✓we.r�atle..osm+,ee.. Reportl0:W0729 Vewpump reports online ar www.e Wiremie'. Pa0a 1 of 1 n - o�-'?