Loading...
HomeMy WebLinkAboutBLD2021-01076 Revised SFR - BLD Inspections - 4/24/2024 Lj-)uJ2011- 0k0-1tQ - 1►2 M Aa1r t omemTE MECHANICAL LqANUFACTURED HOME Gu e-acrtings t w cks s F'tpin Ribbons tcTtecio.-Date BY trrt mor-Date BY Daly g3, Extesc;r Date By ExW..=-Date ay aolrrt load I lsci;ad IF INSULATION Date BY �{�!SLAB INSULATION N Date By Data BY FIFE DEPA.R ENT rw�n�3ocr tti�l4s Roars t'iane � Date By Sy DECKS FRAWNG 1i #s Hate By Data By BY PROPANE TANKS PLUMBING Y.autt CtaKs . By Date ay ETHER Data By E}ah� BY y,pe Data By f DRYWALL fl�[ttt 4f Type: Int Brace Wall Dew By Dates Dutc BY FINAL INSPECTION 1 CD Firs Seperation m• Gate By Data Ey pata Sy J- CD s Pass or Request Ins.p t E. TyW of Il sp- Fail D-a1 Date Done By CD CD m � f"5 o ?7ca1a, f°barlh�s �CatS . 0 0 Gq W 6-.w w', �v3 s Sf'Zz IL A m � I Gti«6 Q�Y.Vv� �4�5 .{- 1�Iwwbi ass ZG Z ED (�- MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Be lm ext.352 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: BLD 2y21 — O I y 7!i ADDRESS/LOCATION: 112 E J&4c n Lints Df- S . FINDINGS:, �jo L t y Sijp1 , o� -k� tior 6'V- Plurv►Io�Mu l�o NAB- l�sula�c.. Items listed above must be corrected to zain compliance. R THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. gMake corrections, items will be checked on the next inspection. OK to Date: (o 1S123 ❑ Please contact our office regarding possible Department: &17 structural damage incurred by recent Inspector: J "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 " 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER IQ\ ADDRESSILOCATION: �,CL C—� FINDINGS: Items listed above must be corrected to gain compliance. [;�-MIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. -fIT—a-11 for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: ?FAQ ,� ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: � Qf Y "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: ADDRESS/LOCATION:``�_ � N a1W)- e 1� FINDINGS• ( l e ' in Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. fn Kt Date: ❑ Please contact our office regarding possible Department. L structural damage incurred by recent Inspector: ✓ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 --" 360-427-9670 ext 352 www.co.mason.wa.us FBLD202'1-01076 NEW SINGLE FAMILY RESIDENCE DESCRIPTION: NEW SFR ISSUED: 12/16/2021 ESS: 112 E MASON LAKE DR SOUTH GRAPEVIEW EXPIRES: 06/14/2022 PARCEL: 221085000010 APPLICANT: SMITH FAMILY CABIN LLC OWNER: SMITH FAMILY CABIN LLC 31 OHANA LN 31 OHANA LN HOQUTAM,WA 98550 HOQUTAM, WA98550 CONTACT: DENNY'S HOME IMPROVEMENT INC 3085 E MASON BENSON RD GRAPEVIEW,WA98546 360.426.3767 GENERAL CONTRACTOR'S LICENSE: DENNY'S HOME IMPROVEMENT INC License: DENNYH197386 3085 E MASON BENSON RD Expires: 01/02/2022 GRAPEVIEW,WA98546 360.426.3767 VALUATIONS: FEES: Paid Due Uncovered Deck 499.00 $7,485.00 Plan Check Fee $1,895.71 $0.00 Covered Deck/Carport 910.00 $20,020.00 State Fee-Residential $6.50 $0.00 R-3 VB Residential, one- 2987.00 $369,432.16 Plumbing Base Fee $25.00 $0.00 and two-family Plumbing Fees $149.00 $0.00 Building Plan Review/Change of $120.00 $0.00 Use-Onsite Sewage Mechanical Base Fee $30.00 $0.00 Technology Surcharge $104.30 $0.00 Mechanical Fees $199.00 $0.00 Planning Review Fee $240.00 $0.00 Building Permit Fee $2,916.48 $0.00 Total: $396,937.16 Totals : $5,685.99 $0.00 FIXTURES Printed by:Genie Mcfarland on:12/16/2021 10:21 AM Page 1 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 Shelton, WA 98584 -- 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01076 City Mechanical Fixtures City Plumbing Fixtures 1.0000 Gas Outlet(s) (1-5) 1.0000 Number of Clothes Washers 1.0000 Dryer Vent(s) 1.0000 Number of Dishwashers 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Kitchen Sinks 1.0000 Furnace(s) 1.0000 Number of Water Heaters and or Vent 1.0000 Heat Pump(s) 2.0000 Number of Hose Bibs 1.0000 Wood/Gas/Pellet Stove(s) 3.0000 Number of Showers 5.0000 Spot Vent Fan(s) 3.0000 Number of Toilets 5.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Framing Inspection Footing Inspection Rough- Plumbing Inspection Foundation Wall-Pre-Pour Inspection Mechanical Inspection Underfloor Inspection R«.a...__.__a a k a a R a a a a._ .a_____a Insulation Inspection Foundation and roof drains inspection - e BLD-Final Inspection ... ........ ............... ........ ........ ....... ....... ....... ....... ....... ....... ....... ....... ...... Shearwall Inspection CONDITIONS The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. t All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY B DI UILNG DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. • A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. All property lines shall be clearly identified at the time of foundation inspection. Printed by:Genie Mcfarland on:12/16/2021 10:21 AM Page 2 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 -- 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2021-01076 * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at(206)357-2620, ext. 630. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are available in '/4 or'/z sheets. The Mason County Permit Center will also have s­11. ome available. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * The foundation/footing must be placed on undisturbed,firm-native soil. Printed by:Genie Mcfarland on:12/16/2021 10:21 AM Page 3 of 8 Mason County �k Mason County - Division of Community Development 615 W. Alder St. Bldg.8 .;,j, Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01076 * Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U- Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. 2 Heat pump 1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section c M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. Air-source centrally ducted heat pump with minimum HSPF of,9�.5. 3 Ct,64-w- l t(7 I 5.1 A ain water heat recovery unit(s) shall be installed, hich captures wastewater heaffrom all and only the showers and has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. To qualify to claim this credit, the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it. Labels or other documentation shall be provided that demo strarL tes thynt the unit .complies with the standard. �_/ 5.5 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. 5 7.1 All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher—Energy Star rated c L� Refrigerator(if provided)— Energy Star rated washing machine—Energy Star rated Dryer—Energy Star rated, ventless dryer with minimum CEF rating of 5.2, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. Printed by:Genie Mcfarland on:12/16/2021 10:21 AM page 4 of 8 !� Mason County Mason County - Division of Community Development ` 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2O21-01076 * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. --------------------------------- * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to theweather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Genie Mcfariand on:12/16/2021 10:21 AM Page 5 of 8 Mason County • Mason County - Division of Community Development 615 W. Alder St. Bldg.8 � .Hua Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01076 * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. -------------------------------------------------------------------------- A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. All construction must meet or exceed all local and state ordinances in addition to the Intemational Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. Printed by:Genie Mcfadand on:12/16/2021 10:21 AM Page 6 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 �i 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01076 * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed_. * The vegetated area between the shoreline and the new residence is considered to be a Fish &Wildlife Habitat Conservation Area buffer that will need to be retained. * Application acknowledges that the structure is only permitted for use consistent withthe current zoning of the parcel. """' * All setbacks are measured from the furthest projection of the building. " "_"" ___.___.,___. * - On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * M _ Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. _ V A.) Drainfield/Reserve requires a 1Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. The acknowledges, . . _ * pp that the project as proposed will be consistent with all the applicable standards of the Mason County Flood Damage Prevention Ordinance. * A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2018 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S2.0 designate wall(s)type 2 and 3 with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Genie Mcfadand on:12/16/2021 10:21 AM Page 7 of 8 Mason County • - Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 -_ 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCEBLD2021-01076 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: / Contractor or Authorized A nt: Date: r Printed by:Genie Mcfarland on:12/16/2021 10:21 AM Page 8 of 8 , NFor single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for g climate zone 5 of[CC 400. Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits)and Table 406.3 (energy credits)to achieve the following minimum number of credits.To claim this credit,the building permit drawings shall specify the option selected and the maximum tested building air leakage and show the qualifying ventilation system and its control sequence --7- of operation. ' Lij 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. Medium Dwelling Unit:6 credits jJ All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit:7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table,review the details in Table 406.3(Single Family),on page 4. Summary of Table R406.2 Heating Credits-select ONE O tions Fuel Normalization Descriptions heating option User Notes P 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 3 Electric resistance heat only-furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each P category 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 1 Efficient Building Envelope 0.5 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 .❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 , 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.1' High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC - 1.0 ❑ 3.3' High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 High Efficiency HVAC 1.5 3.6' High Efficiency HVAC 2.0 ❑ Prescriptive Path-Single Family 2018 Washington State Energy Code-R 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ 5.1' Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 5.6 Efficient Water Heating 2.5 ❑ 6.18 Renewable Electric Energy(3 credits max) 1.0 ❑ 7.1 Appliance Package 0.5 Total , Credits a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger,may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)or C403.3.2(5) c. Equipment listed in Table C403.3.2(1)or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path—Single Family 2018 Washington State Energy Code-R