HomeMy WebLinkAboutBLD2018-00746 Heatpump - BLD Permit / Conditions - 7/12/2018 Inspection Line (360)427-7262
coL��A MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County
615 W Alder St
Shelton, WA 98584
W4 RESIDENTIAL BUILDING PERMIT
BLD2018-00746
OWNER: JACK MATSON RECEIVED: 7/12/2018
CONTRACTOR: KLIEMANN BROS HVAC LICENSE: KLIEMBH021 BT EXP: 1/27/2020 ISSUED: 7/12/2018
SITEADDRESS: 80 E HUMMINGBIRD LN BELFAIR EXPIRES: 1/12/2019
PARCEL NUMBER, 122061200090
LEGAL DESCRIPTION: TR 9 OF GOVT LOT 2 & TAX 392-A' & TAX 743-A*
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DUCTLESS HEAT PUMP FOLLOW ST RT 3 TOWARD BELFAIR, TURN LEFT ON ST RT 106, THEN
RIGHT ON HUMMINGBIRD LN TO SITE
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.:
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: MEC Fire Dist.: 2 No. of Stories: Occ. Load: Building:
Valuation: Building Height: Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline & Planning Information
Make: Length: Ft. Front: Ft. Shoreline: Ft.
Water Body:
Rear: Ft. Slope: Ft. SEPA?:
Model: Width: Ft. Side 1: Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft. Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Oty. Type By Date Amount Receipt
Heat Pump 1 Building Special inspection GMM 7/12/2018 $ 73.00 S120180000000i
Mechanical Permit Fee GMM 7/12/2018 $ 18.20 S120180000000i
Mechanical Base Fee GMM 7/12/2018 $ 2&50 S120180000000i
Total $ 119.70
BLD2018-00746 Please refer to the following pages for conditions of this permit. Page 1 of 4
CASE NOTES FOR
BLD2018-00746
CONDITIONS FOR
BLD2018-00746
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-09B.2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM
STANDARDS,SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE.
X % 1
3) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and
approved by Washington State Labor& Industries must be available on-site during the inspection.
The Mason County Building Inspector will inspect the following: Verify that the system is installed in accordance with manufacturer specifications;The
inspector will check to make sure that the exterior unit is permanently installed and supported, the exterior unit complies with required setbacks to
property lines, fuel tanks are located at least 10-ft from the system, a source of ignition,all exterior penetrations are properly sealed,condensate lines are
installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location outside of the
foundation, copper refrigerant lines are insulated with '/z"thick continuous closed-cell foam insulation or better, indoor units are located at least 3-ft from
smoke and carbon monoxide alarms,and that modifications made to the structure, to install the unit, does not affect existing structural members.
X 7�
4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit re--- tipn.
X
BLD2018-00746 Please refer to the following pages for conditions of this permit. Page 2 of 4
5) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the
IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC
systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be
available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketino or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts
shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets
equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance
to IECCANSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are
available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct
tightness tes`�t``ing is not required if the air handler and all ducts are located within the heated space.
X `= )
s
6) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been
identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or
operator ha fined written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
X /)
7) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason Couaty ordinances and building regulations.
s
8) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have-prev action from being taken. No more than one extension may be granted.
X
BLD2018-00746 Please refer to the following pages for conditions of this permit. Page 3 of 4
?INNER/BUILDER acknowledges submission of inaccurate information may result in a sfop work order or permit revocation.Acknowledgement of such is by
signature below. I declare that I am the owner,owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permittapplication becomes null&void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
Signature Date
,Nl ►J OWNER - REPRESENTATIVE 7CO;NT_;"dTOR
Print Name (Circle one to indicate)
BLD2018-00746 Please refer to the following pages for conditions of this permit. Page 4 of 4
o CONCRETE MECHANICAL MANUFACTURED HOME D
0
Footings I Setbacks Gate By Ribbons N
Gas Piping Q
0o Interior Date By Interior-Date By Date ay Z
rn Exterior Date By Exterior-Date By
Set-up
Point Load tlsolated Footings INSULATION Date By n
Date By BG I SLAB INSULATION ---_
Data By FIRE DEPARTMENT
Foundation Wails Floors Date By
Date By Data By DECKS
FRAMING Wails Date By
Date By Data gy' PROPANE TANKS
PLUMBING vault Data By
Gate By OTHER
Groundwork Attic
Type:
Date By Date By Date By
13M.v DRYWALL Type_
_U Date By
Int Brace Wall Date By 1001
17,
y Gate By FINAL INSPECTION
co Water Line Fire Seperation NC
m Date By Date By Date J, By��
m 00
Pass or Request Inspect. c
5 Type of insp. Fail Date Date Done By Comments
o
C w
y
O
n
0
7
n.
o'
0
Err
a
(D
3
tQ
CD
0