HomeMy WebLinkAboutBLD2008-00837 MFG Home - BLD Permit / Conditions - 7/31/2008 Inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext. 352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT BLD2008-00837
OWNER: GARY PURCHASE
CONTRACTOR: SOUTH SHORE CONST 1-360-275-0818 360-509-1342 LICENSE: SOUTHSCO16NL EXP: RECEIVED: 7/8/2008
SITE ADDRESS: 1311 E ALDERWOOD RD BELFAIR ISSUED: 7/31/2008EXPIRES: 1/31/2009
PARCEL NUMBER: 122077590171
LEGAL DESCRIPTION: TR 17-A OF SURV 5/94-96 LOT: A OF SP#2605#608711
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Manufactured Home. LOT 17A OF BELFAIR ACREAGE TRACTS DRIVEWAY ABOUT 60OFT W OF
RAZOR ROAD ON N SIDE OF ALDERWOOD RD
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: MH Insp.Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size: Deck:
Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:
Valuation: Building Height: Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline & Planning Information
Make:Liberty Length: 40 Ft. Front: S 246.0 Ft. Shoreline: Ft. Water Body:
Rear: N 80.0 Ft. Slope: Ft. SEPA?: No
Model:284430 Width: 27 Ft. Side 1: W 45.0 Ft. Shoreline Desig.: Not Applicable
Year:1999 Serial No.: Side 2: E 42.0 Ft. Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Mobile Home Submittal Fee KKK 7/8/2008 $247.00 S22008000
Planning Review Fee KKK 7/8/2008 $190.00 S22008000
Address Fee KKK 7/8/2008 $162.00 S22008000
Fire Warden Review KKK 7/8/2008 $68.00 S22008000
EH Plan Review KKK 7/8/2008 $40.00 S22008000
Water Adequacy Plan Review KKK 7/8/2008 $40.00 S22008000
Mobile Home Issuance Fee MAL 7/15/2008 $247.00 612008000
EH Plan Review TW 7/28/2008 $60.00 612008000
Total $1,054.00
BLD2008-00837 Please refer to the following pages for conditions of this permit. 1 of 7
CASE NOTES FOR
BLD2008-00837
CONDITIONS FOR
BLD2008-00837
1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved
access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roadWect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
X
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647 0 . The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
3) Approved ensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building
Departm nt r to any further inspections being performed or approvals granted.
X
5) Owner/A Im
esponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved o uments will result in failure of required building inspections.
X
7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X lYV )
8) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the
Building Dep, rt prior to any further inspections being performed or approvals granted.
X
BLD2008-00837 Please referto the following pages for conditions of this permit. 2 of 7
9) Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State
Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present
to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified
installer responsible for each major part of the installation. RCW43-63B.090
An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily
located in plain site within three of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each
installer performed or,in Iled. certification number and signature of the certified installer responsible for each major part of the installation.
WAC365-210 X
10) If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American
National Standards Institute (ANSI). To order the ANSI instructions you may either get an order form from the Mason County Building Department or you
can contact the Offfice of Manufacturing Housing (360) 725-2800.
11) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609
BASIC WIND PEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH.
X
V I/ -
12) Per IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in
accordance with a applicable provisions of this section and the manufacturer's installation instructions.
X
13) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor i ac ledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X
14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revoc n.
X i
15) Lake Cushman area is designated with a 551b snow load rating. The owner/agent of this permit acknowledges that if the unit permitted under this permit
does not Reet the recommended snow load rating, there is a potential for failure due to weight accumulation beyond that of the design criteria.
X
BLD2008-00837 Please referto the following pages for conditions of this permit. 3 of 7
16) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all
responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the
inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason
County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been
discovered. I further understand that this investigation will be scheduled as time allows. Until resolution of any/all problems no occupancy (Final
Inspection) will be granted for the residence.
OWN E RICO NTRACTOR(indicate which) Signature X
This permit is being issued to the applicant to allow the moving of this mobile home onto his/her private property to perform the necessary corrections to
this unit to bring it into compliance with HUD Standards, and get the unit recertified by the State of Washington Department of Labor and Industries. This
unit is not to be occupied. No utilities are to be connected. No permanent set up is to begin. This permit is valid for sixty (60)days only. No extensions
will be granted. Any vi lation of the conditions of this permit or the denial of a permanent installation permit will result in the determination that the unit
must be removed fr, property at the expense of the owner.
X
18) This permit is for the ent and installation of the manufactured home only and does not imply approval or review for any other items indidcated on
the plot plan. X
BLD2008-00837 Please referto the following pages for conditions of this permit. 4 of 7
19) Permanent Address must be posted and visible from the road
Deck must be safe and meet code for year building permit was issued. Rebuilt decks are required to meet current code. All guardrails and handrails
must be in good condition and meet code for year built or current code if replaced.
Skirting must be vented 1:150 and backfill sloped away from unit 2% for a minimum of 5' around the perimeter of the unit
Gutters and downspouts must be installed with splash blocks provided
All exterior penetrations must be sealed
HWT Pressure relief line and dryer vent must exit skirting a minimum of 6"with a maximum of 24" above grade.
The unit shall have a minimum of 16"x24" crawl space access provided HOWEVER, if the unit has not received a set up inspection and is skirted, 4
panels centrally located (one on each side of unit) shall be removed by the owner/applicant prior to requesting the inspection.
All conditions on the original or issued permit must be met
If the unit was installed by a WAINS certified installer/contractor since July 1, 2003, CTED Installer Tags must be available
It shall be the responsibility of the person requesting the inspection to provide the
manufacturer specifications, ANSI Standards or approved engineered design for the installation of the unit and have them available on site for inspection.
Each inspection required will be assessed a fee as adopted under Mason County current fee schedule. Re-Inspection fees will be assessed each time an
inspection is requested and required items are not completed prior to the inspection being performed
ENFORCEMENT PROVISION:
Any manufactured/mobile home and/or appurtenant structures found non-compliant with any county or state regulation are subject to enforcement action
and subsequent vi lation and penalties pursuant to the Mason County Code.
X
20) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your proj ct.
X
21) Placement o structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes.
22) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or regulat n, must be reviewed and approved by Mason County prior to construction.
X ��
BLD2008-00837 Please referto the following pages for conditions of this permit. 5 of 7
23) - CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector s a be made prior to requesting additional inspections.
X
24) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including
installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be
clearly marked in the installation instructions.
25) Owner/applicant must obtain a seperate permit for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit
prior to the placement of the tank. X
26) All property lines shall be clearly identified at the time of foundation inspection. X
27) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County orc�irr�nces and building regulations.
X t ��
28) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X I J�fj
29) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, and flaMQ
Install metal connectors approved for contact with the new types of pressure treated material.
X
30) Retaining walls needed to support a surcharges h as structures, roads, or to support slopes, shall require a separate building permit and approval prior
to construction of the retaining wall. X
31) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"A
pproved ed it Plan"to ensure these structures are shown and meet the setback conditions listed.
32) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these struc ures meet the setback conditions listed.
X 9�2
BLD2008-00837 Please refer to the following pages for conditions of this permit. 6 of 7
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWNER OR AGENT: _ DATE:
BLD2008-00837 Please referto the following pages for conditions of this permit. 7 of 7
o CONCRETE MECHANICAL MANUFACTURED HOME C
o Bate By . -- -- ;0
Footings i Setbacks Gas Piping Ribbons 0
o Inferior Date By Interior-Date BY Jute S/ . !l d D
0 6
Exterior Date By Extarirr-Date B — _____ __ N
J INSULATION Sect-up m
Point Load I Isolated Footings Date .a t3
BG I SLAB INSULATION
Date By Date By FIRE DEPARTMENT
Foundation Walls Floors Date By
Date By Date BY DECKS
FRAMING Walls Date By
By Data By PROPANE TANKS
Vault PLUMBING Date 3y
Date By OTHER
Groundwork Attic
U,a bo B Date 9y Type.
y Date P y
D.Wv DRYWALL Type-
Int Brace Wall Data By co
Date By y __._....__�.� _.
Date B FINAL INSPECTION
v Water Line Firs Separation IVO
L: irz By Date By Data 0` ,d tty O
m Co
Pass or Request TIFnspect. O
0 Ty a# Insp. Fail Date Date Done By Comments w
o/j1 � � �
v
C, rd
a
o'
0
m
i
0