Loading...
HomeMy WebLinkAboutCOM2015-00085 heat pumps in PUD Bldgs - COM Permit / Conditions - 5/26/2015 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Cot, Mason County Bldg. III Phone: (360)427-9670, ext. 352 ' 426 W. Cedar Shelton, WA 98584 Ikc4 COMMERCIAL BUILDING PERMIT COM2015-00085 OWNER: MASON COUNTY PUD 3 RECEIVED: 5/20/2015 CONTRACTOR: AMERICOOL HEATING 360.273.3300 LICENSE: AMERIHA950PO EXP: 10/20/2015 ISSUED: 5/26/2015 SITE ADDRESS: 21341 ESTATE ROUTE 3 BELFAIR EXPIRES: 11/26/2015 PARCEL NUMBER: 122064460040 LEGAL DESCRIPTION: TR 4 OF SE SE S 26/13 SURVEY 1/71 PROJECT DESCRIPTION: DIRECTIONS TO SITE: 2 HEAT PUMPS INSTALLED IN PUD BUILDINGS; 1ST&2ND 3 MILES SOUTH OF BELFAIR ON HWY 3 FLOOR UNITS General Information Construction&Occupancy Information Type of Use: COMMERCIAL Insp.Area: No. of Units: Type of Constr.: Type of Work: MEC Fire Dist.: 2 No. of Bathrooms: Occ. Group: Valuation: No. of Stories: Exit Design. Load: Building Height: Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: Model: Width: Building: Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline&Planning Information Front: Ft. Shoreline: Ft. Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.: Side 1: Ft. SEPA?: Comp. Plan Desig.: Side 2: Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2015-00085 Please refer to the following pages for conditions of this permit. Page 1 of 4 Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Heat Pump 2 Mechanical Permit Fee SRN x;nnnnu ass an gi9nirmn Mechanical Base Fee IRN x;ignigntx; v)a x;n g1gnunn Final Inspection Fee ARN r,ignnnis T,73 nn glgnirnn Total $137.90 CASE NOTES FOR COM2015-00085 CONDITIONS FOR COM2015-00085 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647- 98Q 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to = WA state law. X (/� 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28., X 3) Existing roof deck shall be insulated to a minimum of R-38 if: The roof is un-insulated or existing insulation is removed to the level of the sheathing, OR All insulation in the roof/ceiling was previously installed exterior to the sheathing or non-existent. X -7. -- 4) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x �----- 5) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X COM2015-00085 Page 2 of 4 6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X /11� 7) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-com I*pant with Mason County ordinances and building regulations. X ���._ 8) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the-vermiLholder have prevented action from being taken. No more than one extension may be granted. X 9) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X � OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. 12-3 Signature Date 1\I tea` L�. U D,( G, �RE �SETATIVE z CONTRACTOR Print Name e-ta-ir��ieatej COM2015-00085 Page 3 of 4 O N CONCRETE MECHANICAL MANUFACTURED HOME > C3 Date By Footings J Setbacks Gas Piping Ribbons Z o Interior Date By Interior-Date By Date By n 00 Exterior Date By Exterior-Date By O C.n INSULATION setup C Point Load/Isolated Footings Date By Z Date By Data SLAB INSULATION By FIRE DEPARTMENT Foundation Wails Floors Date By C Date BY Data By DECKS w FRAMING Wails Date By Date By Data By PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwork Attic Date By Dale By Type Date By D.W.v DRYWALL Type n InL Brace Wall Date By 0 Date By ic Date By FINAL INSPECTION N Water Line Fire Separation � Date By Date By Date to Y By j,#0) C Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments O0 r A O A w o� c y MASON COUNTY PERMIT Na.C'o��Q15'Gy�$5 DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING.FIRE MARSHAL WWW-CO.MASON.WA.US (360)427-9670 Shelton ext352 Mason County Bldg, III, 426 West Cedar Street (360)275-4467 Belfair ext. 352 r si PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext.*E C E I VE D PLUMBING & MECHANICAL PERMIT APPLICATION MAY 2 0 2015 F;N��AME: INFOR NATION: CONTRACTOR INFO NATION: 42 6 W. CEDAR h,+.So.V if v NAME: T. ADDRESS: .D. 14 MAILING ADDRESS: 1-7�p,V STATE: l�OA ZIP:��1L CITY:f2o lrgt SONE:3(ey •4124-Z2S1-CELL; PHONE:. 3 o--,17g-J3C0 CELL: EMAIL: EMAIL L /$- l°�✓� L&I REG#A-A 09 1 0A 10�LZ-5 EXP. O/Zo lam"-` ARC L IN)F' EMATION• PARCEL NUMBER(12 DIGIT NUMBER): LEGAL DES CRZPTION(A,6BREvt fTED): Si- / / SITE ADDRESS: / / T2 e1 DIRECTIONS TO SITE ADDRESS: 9 Imo' TYPE OF JOB NEW ADD ALT REPAIR OTHER USE OF 13UILDING�b��a,,,LOCA,T'ION OF FI TURES/UNIT'SNUMBER -1 FLOOR 2' 'FLOOR` BASEMENT GAP.AGEOTHER PLUMBING FIXTURES(SHOW OF EACH) MECHANICAL UNITS Dym of Fixture Fees Fuel Type-Electric LPG Natural Gas Heat Pump Toilets TYtie o f Unit No. Units Bathroom Sink �f Fees Bath Tubs Furnace Showers Heatpurnp Spot Vent Fan Water Heater CIothes Washer Propane Tank Gas Outlets Dishwasher Kitchen he Wood/Gas/Pellet Stove r Hosebibs Kitchen Exhaust Hood Other, — Dryer Vent Other Base Fee Base Fee j� TOTAL PLUMBING TOTAL MECHANICAL t V FAcknowledgement NER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. of such Is by signature below, I declare that I am the owner,owners legal representative, o r contractor. I further declareI am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,includingeasement holder or parties of interest regarding this project The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This Permit/application becomes null&Vold if work or authorized construction is not commenced within 180 days or If construction work is suspended for a Period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT A LIGATION O 180 DAYS WILL INVALIDATE THE APPLICATION. X .--- Signature of Appli Da / Ow er/OwnPrint Na ers Re resentativ /Con tractor (indicate which one) D TE bAliE BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Thursday, December 8, 2022 at 10:09:42 Pacific Standard Time Subject: Re: PUD 3' Belfair Warehouse Project ec 20 t 4:23:42 PM Pacific Standard Time <m: Loretta Swanson To: Kell Rowen CC: Trish Woolett CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize t nd know the content is safe. No trigger. From:J n Holzgrove<justinh@masonpud3.org> Se iday, December 2, 2022 3:37:06 PM Kell Rowen Cc: Loretta Swanson; Trish Woolett Subject: Re: PUD 3's upcoming Belfair Warehouse Project Caution: External Email Warning!This email has originated from outside of the Mason County Network. Do not click links or open attachments unless you recognize the sender, are expecting the email, and know the content is safe. If a link sends you to a website where you are asked to validate using your Account and Password, DO NOT DO SO! Instead, report the incident. Thanks, Kell. Loretta, please let us know. We haven't received our final elevations yet for the switching station. I'm expecting a 30%design by the end of the year.The final rock surface will be clean, larger cobble,at 6" uniform depth for substation standards. I am anticipating that we won't have any soils import or export,we'll just be taking the"high side" in the southwest corner towards the"low side" in the northeast corner.This will be within the existing fence and pulling away from the slope. But,we'll see officially when we get the civil drawings. Have a great day! Justin On Dec 2,2022, at 3:27 PM, Kell Rowen<KRowen@masoncountywa.gov>wrote: CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hi Justin, I don't think converting the asphalt to crushed gravel will trigger stormwater requirements, but I am including Loretta to confirm. Will you be staying beneath the grading permit threshold for rock? Page 1 of 3 Kell Rowen I Director Mason County Community Development 0: (360) 427-9670 ext. 286 C: (360) 463-3035 www.masoncount.yLALa.gov From:Justin Holzgrove<justinh@masonpud3.org> Sent:Thursday, December 1, 2022 4:11 PM To: Kell Rowen <KRowen@masoncountywa.gov> Subject: Re: PUD 3's upcoming Belfair Warehouse Project Caution: External Email Warning!This email has originated from outside of the Mason County Network. Do not click links or open attachments unless you recognize the sender, are expecting the email, and know the content is safe. If a link sends you to a website where you are asked to validate using your Account and Password, DO NOT DO SO! Instead, report the incident. Hi Kell. As we're getting further down our path of the PUD 3 Belfair Warehouse Project, I have another follow up question for you-- We'll be replacing all of the old asphalt at the site with more than an acre of newly opened pervious surface made up of clean crushed rock that allows for better water infiltration.That being the case, will we need to meet any additional stormwater requirements?The project is still scheduled to stay completely within the existing fence line. Thank you. Justin From: Kell Rowen <krowen@masoncountywa.gov> Date: Monday, May 23, 2022 at 9:39 AM To:Justin Holzgrove <justinh @masonpud3.org> Subject: RE: PUD 3's upcoming Belfair Warehouse Project CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hi Justin, I'm available between 11 and 2 today, 9:00 to noon tomorrow, all day Thursday. Kell Rowen I Community Development Administrator Mason County Community Services 0: (360) 427-9670 ext. 286 C: (360) 463-3035 httpE/Zwww.co.mason.wa.us/community-services Page 2 of 3 From:Justin Holzgrove<justinh@masonpud3.org> Sent: Monday, May 23, 2022 8:37 AM To: Kell Rowen<KRowen@masoncountywa.gov> Subject: PUD Ts upcoming Belfair Warehouse Project Caution: External Email Warning!This email has originated from outside of the Mason County Network. Do not click links or open attachments unless you recognize the sender, are expecting the email, and know the content is safe. If a link sends you to a website where you are asked to validate using your Account and Password, DO NOT DO SO! Instead, report the incident. Good morning, Kell. If you have a few minutes, I'd like to chat with you about an upcoming multi-year project PUD 3 is planning for its Belfair Warehouse (21341 SR 3) and get your advice on how to proceed with the various applications. Will you let me know some availability this week(up to 15 minutes?) and I'll send a Teams meeting invite? Thanks! Justin Holzgrove Director of Engineering& Utility Services Mason PUD 3 2621 E Johns Prairie Rd. PO Box 2148 Shelton,WA 98584 Phone:(360)426-8255 Direct:(360)432-5323 Regular Office Hours: Monday—Thursday,7:00 AM—5:30 PM www.pud3.org Mason County PUD No. 3 is subject to the Washington Public Records Act, RCW 42.56. Therefore, this email, and its attachments if any, may be disclosed as a public record. Mason County PUD No. 3 is subject to the Washington Public Records Act, RCW 42.56. Therefore, this email, and its attachments if any, may be disclosed as a public record. Mason County PUD No. 3 is subject to the Washington Public Records Act, RCW 42.56.Therefore,this email,and its attachments if any, may be disclosed as a public record. Page 3 of 3 Y� f s 4 s 6 7 e �Y —_% —x __x _x_ -f% -- x x x— -x_ _ % S �- RIVE BELFAIR R GVf B CVT t px t ,xr rr S — I @@ 8 + HIGH BUS HIGH BUS B x H*H BUS -NIGH BUS z NAB O Cog k CVTS T f z 0 OALLYNx curs x v P x- _..x -x- x x x 5i a,x DSGN CAD FEB Nx<] MASON COUNTY PUD NO.3 JOB NUMBER REV v DRN CAD FEBM]] /� o �c" My FEB]ox] �POWER BEEFAIR SNATCHING STATION oz]eu�D000 A. p M ' B ISSUE FOR REVIEW ONO2MM CAD CAD MV CNM — — --- - DRAWNG NUMBER Y scu.E: t+ls ENGINEERS A IBSUEDFORIox Ol1SBY!] CAD CAD CAD MV GENER/LLARRANGEMENT PI-OO1 n.no.w.e.s�,re REV RE%RB*Ns DATE WIN DOOM CKD A"D REFEREMCEDRAMMM 54"RING BUS 2 3 I s B T e R I A h -0 II b B ELEVATOR C- D rvMON B-B CAD FEB 2023 BNUMBER REV DI1ND80N uB FEs 2oz3 MASON PUD N0.3 J _ CRo w FEs 2ox3 POWER BELFAIR 3IMTCNING STATION o2»w>_aaoo A\ S M .wro w..c sc F SCALE: 3+1S' i ENGINEERS -_----"- -- DRAWNG NUMBER A ISSUED FOR REVIEW CAD CAB MY v C SECTIONS A-& AND C•C P2_001 n r.....eu REV REVISRMe DAN DSGN CKD AM REFERENCE DRAVANGS SBKR RING BUS _. - , 1 7 4L A ti d I I I�II I 0) CU) I I — I II II Ij li'�I II I� I II I;II II I III II I Ili I I — a p Fa s II �I F) A f] A ELEVATION D-0 ELEVATION!-I c 13 I A ° 4 ° o Ft FA FI FS f3 FS N Ft FI ELEVATION E-E DOOR OMP MM 2CQ3 JOB NUMBER REV WIN DRN GAD MAR 2023 MASON COUNTY PUD N0.3 m coo My MAR xma POWER BELFAIR SNATCHING STAnON o:�..�BOBo NSUED F011 RENEW =MpCMAI ENGINEERS ------ OR—N.NUMBER SECnON3 DD,EE,AND FF P1_oo1 rs uwr.Fo REV REWPONS APPO REFERENCE DRAWWGS SBKR RING BUS 1 2 3 4 5 6 7 8 -rubQ CIO ' 114v-z 5K44SS `u 2 PUD3 TO CONSTRUCT ECOLOGY J zn A 7 RECEIVED BLOCK WALL AND DRAINAGE t PRIOR TO DEMOLITION { x 1 D 1 I AUG 2 5 2023 ' 218a 615 W. Alder Street + --- i ul ` 11ypp0g5553752.�2 /'/ Illlllll\\\EE 25. 1n / I\ �5 ' / I I I I I I I\\ \ I F I I f /} I ' IJ �C� x rL N 21 \\ .'i _ `\ i'ui C� n 7 76 , Ili It { \11 Illr rl I '� III \ \ \ \ 1 -a �gST�7AEST LINE r , . r 5 \\ \ \ IIIIIIIiiIIIIII � I O I I { 11 111111{11j11 � I � � � 1 I I ' + 1 Il Illll�lilllil � I � I= I =� 1 � { , 1 1 11 1 1111�1{ V I t i { 1 IIIII 11 I � 1 j I +�rIIfIllIil i jib / /cJill > r �, ` K IS (J3 r S D �'— vJPiTE� F�O7� 0 J � w 0 < ;1`q z voT< o� EAST - ��5� c�Ss --GCTIOIJ 7�0� zo _ K THIS DRAWING WAS PREPARED BY POWER DSGN APG DEC2022 MASON COUNTY PUD NO.3 JOB NUMBER REV O ENGINEERS,INC.FOR A SPECIFIC PROJECT DRN BRG DEC 2022 < TAKING INTO CONSIDERATION THE w 174795 SPECIFIC ANDUNIOUE REQUIREMENTS OF CKD BHR MAY 2023 _k: �wER BELFAIR SWITCHING STATION B THE PROJECT.REUSE OF THIS DRAWING p OR ANY INFORMATION CONTAINED IN THIS i DRAWING NUMBER p DRAWING FOR ANY PURPOSE IS B ISSUED FOR DEMOLITION PERMITTN 5-26-2023 BRG UD BHR BHR SCALE: AS NOT ENGINEERS PROHIBITED VNLESSWRITTEN PERMISSION A ISSUED FOR DEMOLITION PERMITTING 12-30-2022 ERG APG BHR BHR - - GRADING AND DRAINAGE PLAN C3-001 L) FROMBOTH POWER AND POWER'S CLIENT IS GRANTED. REV REVISIONS DATE DRN DSGN CKD APPD REFERENCE DRAWINGS FOR 22.34 DWG ONLY