HomeMy WebLinkAboutBLD2007-01220 Reroof - BLD Permit / Conditions - 11/5/2008 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (ss0)427 9670 ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton,WA 98584
RESIDENTIAL BUILDING PERMIT BLD2007-01220
OWNER: HARSTENE POINTE MAINT. ASSO RECEIVED: 7/5/2007
CONTRACTOR: EXCALIBUR ROOFING & REPAIR LLC 360-432-8837 LICENSE: EXCALRR934DT EXP: ISSUED: 7/16/2007
SITE ADDRESS: 175 E NANTUCKET RD SHELTON EXPIRES: 1/16/2008
PARCEL.NUMBER
LEGAL DE:33CRIPTION OINTE#8 LOT: 25
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NON STRUCTURAL RE-ROOF OF DUPLEX FOR 173 AND 175 175/173 EAST NANTUCKER ROAD -SHELTON
NANTUCKET ROAD.
General Information Construction &Occupancy Information Square Footage Information
No.of Bedrooms: Type of Constr.:
Type of Use: IVIF Insp.Area: No.of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: RR Fire Dist.: 5 No. of Stories: Occ. Load: Building:
Valuation: Building Height: Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body:
SEPA?:
Model: Width: Ft. Rear: Ft. Slope: Ft.
Side 1: Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft. Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Building State Fee CMH 7/5/2007 $4.50 S12007000
Re-Roof Fee CMH 7/5/2007 $105.00 S12007000
Total $109.50
BLD2007-01220 Please referto the following pages for conditions of this permit. 1 of 3
f CASE NOTES FOR
BLD2007-01220
CONDITIONS FOR
BLD2007-01220
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-64i 982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X �
2) Owner/,'k nt is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
3) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED TO A MINI DM OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH
CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X
4) Existing roof shall be insulated to a minimum of R-30 (R38 if roof area greater than 500 s.f.) if: The roof is uninsulated or insulation is removed to the level
of the she OR All insulation in the roof/ceiling was previously installed exterior to the sheating or nonexistant.
X
5) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocAt
X
6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the irternational codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall de prior to requesting additional inspections.
X
7) All buildirg permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County i ances and building regulations.
X
BLD2007-01220 Please refer to the following pages for conditions of this permit. 2 of 3
,
8) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have nted action from being taken. No more than one extension may be granted.
X
9) r 'Per 2003 IRC - SECTION 1609 -WIND LOADS- 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum Wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609
BASIC W PEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH.
X
10) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in
accords a th the applicable provisions of this section and the manufacturer's installation instructions.
X
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Eviden;e of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of
work is by means of i progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described propert d uclu re fqr evi inspection. /
OWNERORAGENT� DATE: � f07
BLD2007-01220 Please refer to the following pages for conditions of this permit. 3 of 3
o CONCRETE MECHANICAL MANUFACTURED HOME
>
C> Date Bv ;0
Co Footings/Setbacks Ribbons (n
Gas Piping
0 Intenor Date By Interior-Date By
Dale By M
N) Exterior Date By Exterior-Date By
Set-up ITI
Point Load/Isolated Footings INSULATION Date 13Y _n
BG I SLAB INSULATION 0
Date By Data By FIRE DEPARTMENT z
i
Foundation Walls Floors Date 13Y M
Date BY Data By DECKS -M
FRAMING Walls Date By >
z
Date By Data PROPANE TANKS
PLUMBING Vault Date (3y
Daft 'y U)
OTHER Cf)
Groundwork Attic 0
Date By Data By Type:
Date ay
MW.V DRYWALL Type:
Int.Brace wait Date By 03
Date BY 9y r
FINAL INSPECTION
(D Water Line Fire Separation W
En C)
Date By Date By Date By CD
-4
Pass or Request Inspect. 6
0 Type of Insp. Fall Date Date Done By Comments rj
5 ha
(D CD
6 :';"V
_0
0)
(0
CD
(n
0
O
(n
(D
0
Mason County Dept. of Community Development
Mason County Bldg. 3
426 W. Cedar
IP14 P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma
Shelton, WA 98584 (360) 275-4467 Belfair
Notice to Obtain Final Inspection
October 28, 2008
HARSTENE POINTE MAINT. ASSO
175 E NANTUCKET RD
SHELTON WA 98584
Case No.: BLD2007-01220
Parcel No.: 121195500025
Proiect Description: NON STRUCTURAL RE-ROOF OF DUPLEX FOR 173 AND
175 NANTUCKET ROAD.
The Mason County Department of Community Development is currently reviewing all
permits that are expired and have not been approved for occupancy and use.
Pursuant to Mason County Code, Title 14 Building and Construction, a permit and
final inspection for this type of activity is required under the 2006 International
Building Code or the code your permit was issued and your property is currently in
violation status of occupancy and use.
Please contact our office to make the necessary arrangements 21 days from
the date of this letter. Failure to contact our office to make the necessary scheduled
inspections will result in enforcement actions.
To bring your site into compliance, you must schedule an inspection. One (1) $68.00
site investigation fee will need to be paid prior to inspection along with any
outstanding fees currently due on your building permit. For every inspection required
after that, you will be charged $68.00 again, per inspection until final inspection and
conditions are met.
To schedule an inspection, please call (360) 427-9670 ext. 262.
If you should have any questions regarding this notification, please contact me at
(360) 427-9670 ext 595.
Sincerely,
Rich Todd Balderston
Mason County Department of Community Development
Cc: Property File
October 28, 2008 BLD2007-01220