HomeMy WebLinkAboutBLD2024-00152 - BLD CD Environmental Health Review - 2/5/2024 MASON COUNTY COMMUNITY SERVICES Permit No:PAJ) `�4-D 152-
PERMITASSISTANC RJSUG R: RECEIVED
1 PERMIT ASSISTANCE
CENTER:
HEALTH•FIRE IMRSR.LL
j 615 W.U]>SYM.SMXrn,WA995M
IMoro SMl (MO)a3T9670eat 3U-F—MW,1437-II96PI EM FEB 0 5 2024
BwMelr Mo)PBM6T•P u:MO)1 -526B m
BUILDING PERMIT APPLICATION z
15 W. Alder <
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: _
NAME: Li=mNorthwel lnc NAME:L=w Nordk ul Inc m
MALWO ADDRESS:11455 61h eve S,Uvil 1-H MAILING ADDRESS:33455 Adds aye S,UN[1-B D z
CITY: Pedeml Way STATE:WA WING CfrY:Fde.]Wry STATR:WA ZIP: 98003 r—
PHONERI: (253)294-1322 PHONE:(253)294-1322 CELL: (253)290-1322
PHONE#2: EMAIL: Sam.MarftnAl.eoom.com = m
EMAIL:S.Mm=(Wwpm.mm L&I REG 8 LENNANL783JO EXP. 03/18/24 z
PRIMARY CONTACT: OWNKR❑ coxraA IML oTxER® D
NAME Sa MES A ( li EMAIL dm Walleuia STATE
r-
M ONS (25 )295 33455 Adds ave5 UWt 1-B [I'IY F Way STpTg WA yp 98003
PHONE f25313941332 CfiLL (25313941322
PARCEL INFORMATION:
PARCELNUMBER(12 DiErt Number) 1272MI-00051 TONING
- Q. LEGAL DSSCRD'IION(ANxeavred) Olympic Ridge mat DISTRICT
STTE ADDRESS 240 NE Olympic Ridge CITY Belfair
DIRECTIONS TO SEMADDRESS
Q
1 , IS THE PROJECT�300 FT OF SIAPE(S)GREATER TITAN IdX: YE90 NO® SNOW LOAD:31.48pa(
L4PROPERTY�2WFTOFTHEFOLLO"Q R' waaepp'y
V SALT Ill LAKE❑ RIMXREEK❑ POND❑ WETLAND❑ SEASONAI.RUNOFF❑ STREAM❑
1, TYPE OF WORK: NEW® ADDmON❑ ALTERATION❑ WAR❑ OTHER 2
USE OF STRUCTURE(%pumas.f ..CannrocxBft. )_New SFR Using APPro Bass,Plan 1217 MF GL
ISUSE: PIUMARY❑ SEASONAL❑ NUMBEROFBEDROOMS 3 NUTABEROFBATHROOMS 2
HEATID STRIICNREI YEs(PBdeBatJ❑ YES(run)s)MBW O NO❑ .
r DESCRIBE WORKN Sin¢l Favul Res'drnlce bnW ad garage mdrnd
4 A SOUARE FOOTAGE:Ijsn,�
( � ISTFLOOR1185 q.ft 2NDFLOOR q.B 3RDFLOOR It BASEMENT q R.
I DECK_q.R COVERED DECKJLPI"Is L q.ft. S[ORAGE q.ft OTHER q.&
,JL GARAGE'0 q.IL Anached0 Detached❑ CARPORT q.ft An«Md0 Dw,ill
MANUFACTURED HOME INFORMATION: 4 COPIES OF THE FLOOR PLAN REQUIEM'
MAKE MODEL YEAR LENGTH
WD)TH BEDROOMS BATHS SEiul&NUMBER
ENVIRONMENTAL HEALTH:
SEWAGEBEWBR SOURCE: SEPTIC[] SEWER® / NEW® EXISTING❑
PLUMBINGWSTRUCfURE? MIR NOD ff3 anachcomlezMWmerAdegma Farm
PERIMSTER/FOUNDATION DRAINS PROPOSED? YES® EMSTNGSQ. Sh4s
EXLSTTNG BEDROOMS PROPOSED BEDROOMS TOTALBFOROOMS
COMMR aknwM6Bea Tel suEonsul d ini t4assmi 1ru,sun.Ina Sop van,wtlerw9nmtrtwallm.04mMe nnsnld aWlNty
agreNee UBMm'.10Jse TM 1111 Te p/ervAl NN6r60tlere Tal I am m11Ya010 recvrve Inis pamll enE b Eo Te xdk tl pnp'eW.l eae
oem�nae pamil.monlmm al Ta ne„..a.9m5ee.mwamB am eaee'^e^'nomar or 9amtl orimarez re9aminv errs lamlel ma vmlmm RaB
aren9are ane mema,mpmmm"Miem Dn. s,-n w.'R it s on.M,m mes null a vwlomy¢Ae svmM1M ues Doan mLocnu:ncne amknsawIomm is MxallWeE pnpb1 m
ea:o,lf—snu.onwrcins,mrna.pcm .a.n PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.N.42)
x �P.Np�llaafiw 8/S/2023
3lpn. MOk&OilprtM c"mled M Ite OWNEM Dale
DKPARTARNT REWEW APPROVED DATE DENIED DATE TAGS/NOTFSICONDTHONS
BVIlOING DEPARTMENT
PLANNP'G DEPARTMENT
PIKE MARSHAL
PDeuc NF"1.rx L
L�49.80' BUILDING 5ET84CKS:
EHAPPROVED R=2,524.93' PUbIiC SOWBr and W8f0r 0 1D' WOE: 5' REAR: 10'
mmm.w�o,ozvazou C=OI'07'49'
TEE =INSTALL TEMP. CONSE ENTRANCE
TSS =INSTALL TEMP. SOIL STOCKPILE
SO — ---- STORM lTq
1 1
STUB �T 2
O g as
0 BSBL TSS "R-5'Matlium density residential district
(TYR)
^o Front yard:10 feel.
Side yard:5 feet for accessory structures and 5 feet for the
PATIO ,.te dwelling unit.
n
n Street side yard.10 feet.
m Rear yard:5 feet for accessory structures and 10 feel for the
9.75' dwelling
Street rearar yat.
rd:
artl:t➢feel.
I
HS 51
PROPOSED 02/06/2024
p ^ SFR APPROVED
-_-___ ___.346 � - -- n MASON COUNTY Di PLANNING
ED ___348- - SevR RutnvAleD
in PROPOSED Digitally
EAVE 1217MF CONTOURS s�,q„,�slI
by Scott
BUILDING Ruetly
ENVELOPE GEL �
16' CONC. 1 1016.
6111 DRIVEWAY I PORCH 10. 8'
- — SS STUB
WALK — _ — STORM
c" -�N - SO _ STDB
o - —_ _ SOIL AMENDMENT NOTE:
J a SEE BMP T5.13 "POST CONSTRUCTION
1 rw o SOIL QUALITY AND DEPTH", WSDOE
TCE STORMWATER MANAGEMENT MANUAL
FOR WESTERN WASHINGTON.
SIDEWALK �INSTALL SILT FENCE. SEPARATION NOTE:
1. ' STRAW WATTLE, OR ANY POR710NS OF STRUCTURES WITH LESS THAN
UNC710NALLY 10-FEET OF SEPARATION SHALL BE FIRE RATED.
NE OLYMPIC RIDGE EQUIVALENT
L-52.07' POWER TRANSFORMER SETBACK Ni
R-2,639.93' 1. MINIMUM DISTANCE FROM ANY POWER
6=01'07'49- TRANSFORMER TO ANY DOOR, WINDOW. ON ALL
NON-COMBUSTIBLE MATERIALS SHALL BE
LOT SIZE = 5.855 SF B-FEET.
IMPERVIOUS 2. MINIMUM DISTANCE FROM ANY POWER
TOTAL IMPERVIOUS: 2,161 SF (36.9%) TRANSFORMER TO ANY COMBUSTIBLE WALLS OR
ROOF: 1.813 SF IROOF SHALL BE 10-FEET.
ORNEWAY: 306 SF FLAT WORK NOTE,
NOTE,
WALK: 33 SF LOT COVERAGE = 1,813 SF (30.9%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 9 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Job Number 0 10 40 `O LENNAR NORTHWEST LLC.
21885 sroM
Barghausen OLYMPIC RIDGE
ConsutLin Engineers,Inc.
Sheet Dines, Da+yy 9 9 HOMESITE 51
1821572nd Avenue South PARCEL NO. 12328-51-00051
Kent,W 98032
Of Doti, a�s/2/23 425W.6222 barghauserscom 240 NE OLYMPIC RDGE, BELFAIR, WA
Rlo:P:\vIxIGP\zleas\agzlees-DNmPa Rays-Plot Plonsday Plot Dote/Tmc8/5/2023 12:52 PM DWIGGS