Loading...
HomeMy WebLinkAboutBLD Plot / Site Plans APPROX. F1 LE COPY hill r — rrSOUND I ELECTRONICS i ,. ; 4621 Pacific Avenue 9 1/ 4" I Zrr Tacoma, Washington 98408-7739 N r; A N A N (206) 472-2955 1 --800--635--3330 I I STAGE MEETING HALL Z � t ; NOTES i I 1, WHERE REQUIRED, ALL FIRE ALARM WIRE MUST GIRLS BE INSTALLED IN METAL RACEWAY, 2. ONLY WIRE ASSOCIATED WITH THE FIRE ALARM SYSTEM IS PERMITTED IN THE F.A. RACEWAY. NO AC VOLTAGE LINES ARE PERMITTED IN THE - - ----- - -- F A RACEWAY, -- — — — _ __ -CONTRACTOR WIRING- ENTERING THE FIRE F ALARM CONTROL PANEL ENCLOSURE MUST PENETRATE ONLY THE TOP HALF OF THE BOX1 /, 9 C', ,�,�v T ft f T� T ='�' TOP AND UPPER RIGHT/LEFT SIDES, 4, CONTRACTOR SHALL NOT CHANGE COLOR CODE AND SHALL TEST ALL WIRING AND SHIELDS TO A,ZB POWER ���-_- + ; - , ; � - ,_ F A BE FREE OF OPENS, SHORTS AND GROUNDS, 5, A SEPARATE EARTH GROUND MUST BE PULLED '= TO ALL CABINETS. ❑L 2 DIALER #1 A ZONER E ALARM �' — 6, DO NOT POWER UP SYSTEM. ALL F.A. PANEL ZA 2 SEE NOTE F C. N T R O L PANEL CONNECTIONS WILL BE PERFORMED BY SOUND ELECTRONICS' PERSONNEL. OTHER METHODS PANTRY KITCHEN FOYER �� 5� (.c, 7,eil,P_ CAN AND WILL VOID WARRANTIES, DO NOT MOUNT DETECTORS WITHIN 3 FEET OF AIR HANDLING OUTLETS, 8, THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL INSPECTION, TEST AND DEMONSTRATION 2B 2A,2B A,B A,28 ARRANGEMENTS WITH THE PROPER AUTH ORITIES, j 2 E� � A P P R O X, 9, CONTRACTOR TO NOTIFY SOUND ELECTRONICS 2A,2B A,2B ZA ONE POWEREEK REQUIR�MEN�SS❑UND C206E472-2955CS' MAN A,B F F 10. ANY CONFLICT OF ENGINEERS (CONTRACT) BOYS CLASSROOM DRAWINGS AND THESE DRAWINGS AND SUBMITTALS SHALL BE BROUGHT TO THE 2 1 CLASSROOM ATTENTION OF ALL PARTIES. 11, ALL EQUIPMENT (WATERFLOW, PRESSURE SWITCHES, DOOR HOLDERS, DUCT DETECTORS, ELEVATOR RECALL, ECTJ FURNISHED BY A,2B OTHERS MUST BE COMPATIBLE WITH THIS FIRE 2A ALARM SYSTEM, 12, FIRE ALARM RISER SYSTEM IS INTENDED TO SHOW ALL CONNECTED DEVICES AND THEIR CIRCUITING, IT IS NOT INTENDED TO REFLECT ACTUAL ROUTING OF RACEWAYS. ROUTING OF A 2 2 4 3/16" THE RACEWAYS IS AT THE DISCRETION OF THE ELECTRICAL CONTRACTOR AS REQUIRED TO SUIT A BUILDING CONSTRUCTION CONDITIONS, 2 WIRING LEGEND 13, ALL FIRE ALARM SYSTEM WIRING IS STYLE 'B' A 2 A, AND STYLE 'Y', E❑L A 1 BLU #18 INITIATING 14, CONTRACTOR WILL COMPLETE THE WIRE SPLICES HORN CIRCUIT F 1 GRY #18 CIRCUIT IN ALL 'J' BOXES AND WIRES NOT CONNECTED TO DEVICES. SOUND ELECTRONICS WILL A,B j 2A B 1 RED #18 HORN TERMINATE AND MOUNT DEVICES AFTER F 1 BLK #18 CIRCUIT CONTRACTOR COMPLETES THE RACEWAY SYSTEM, A F WIRING, SPLICES OF 'J' BOXES AND TESTING OF WIRES, E❑L EOL - - - - - ELECTRIINIC SYSTE �IS LEGENDZONE #2 Z❑NE #3 /� v SYMBOL DESCRIPTION c� SMOKE DETECTOR (MOUNT ON 4 SQUARE W/ 3 );� RING) 10 11/16" 0 HEAT DETECTOR - 135 DEG, R/R-FIXED UNLESS NOTED OTHERWISE (MOUNT ON 4-SQUARE W/ 3 0 RING) FF-] MANUAL PULL STATION FLIHIR PLAN (MOUNT ON 4-SQUARE W/SINGLE GANG MUD RING) HORN/STROBE COMBINATION (MOUNT ON DEEP 4-SQUARE) q PROJECT: SKOKEMISH GRANGE N 1 ti5� ,� ,� LOCATION: HALL N NOTES UL FIRE ALARM MONITORING PROVIDED BY, REVISIONS W. 2300 SKOKOMISH VALLEY RD, THE ALARM CENTER INC, 'ti APPROVED NO. DATE BY DESCRIPTION ENGINEER/DESIGNER: N DASONCOUNTYFIREMARSHAL DAVID EI ELLIS ❑N BY BUILDING APPROXIMATELY 4000 SQUARE FEET, TE E, tRr��� r, ELECTRICAL CONTRACTOR: SUBJECT TO FIL�9?!a'«�:� _�.. 4G� ALL APPLICABLE CODES SHALL APPLY. �R SOUND ELECTRONICS AND/OR OMISSIONS ON FLRwu ARE SOI_U_ E- SPONSIBILITY OF OWNEFCCNTFAC-'G?. ClW`,REC- TIONS RECUIRED FROf.1 FIELD It;SF=f l;0`, SHALL SCALE: 1/8 -1/-0�� �DRAWN BY: ROVED B ' BE AT OWNER/CONTRACTOR'S EY.F!.:3E. TS+IS AP- PROVAL DOES NOT GRANT TO ANY PERSON THE 09-15,1994 RJE RIGHT TO VIOLATE ANY CITY OR STATE LAWS. DATE: TITLE: DRAWING NUMBER: FIRE ALARM SYSTEM 6309-303 SHEET OF