HomeMy WebLinkAboutBLD2012-00386 Furnace - BLD Permit / Conditions - 6/17/2012 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton, WA 98584
IP
' MECHANICAL PERMIT BLD2012-00386
OWNER: TOM, WOODMAN RECEIVED: 6/5/2012
CONTRACTOR: OLYMPIC HEATING AND COOLING 360-426-9945 LICENSE: OLYMPHC986BA EXP: 1/1/2( ISSUED: 6/5/2012
SITE ADDRESS: 346 E POINTES DR EAST SHELTON EXPIRES: 12/5/2012
PARCEL NUMBER: 121195000168
LEGAL DESCRIPTION: HARTSTENE POINTE LOT: 168
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
FURNANCE HARSTINE POINTE
General Information Setback Information
Front: Ft. Shoreline: Ft.
- Type of Use: SF Front:Area:
Type of Work: MEC Fire Dist.: 5 Rear: Ft. Slope: Ft.
Side 1: Ft.
Valuation: Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Furnace<100K 1 Mechanical Permit Fee TW 6/5/2012 $18.30 S120120000C
Mechanical Base Fee TW 6/5/2012 $28.50 S120120000C
Total $46.80
BLD2012-00386 Please refer to the following pages for conditions of this permit. Page 1 of 3
CASE NOTES FOR
BLD2012-00386
CONDITIONS FOR
BLD2012-00386
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Divisi her are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800� 4 - The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) Owner%�nt is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
3) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE
MINIMVeNDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE.
X
4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permitynfation.
X s
BLD2012-00386 Please refer to the following pages for conditions of this permit. Page 2 of 3
5) Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable
sections of the IRC and IMC.
Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems
are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for
inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal
ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or
rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in
accor Vince to WSEC Section 1411.
` X V14e
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to requ t a inal inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Maso C ordinances and building regulations.
X
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time
for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the
permit hol4r have prevented action from being taken. No more than one extension may be granted.
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
occupied. Proof of continuation of work is by means of a progress inspection. The owner or the agent on the owners behalf, represents that the information provided is accurate
and grants employees of A`lason County ccess to the above described property and structure for review and inspection.
OWNER OR AGENT: ( DATE: -
BLD2012-00386 Please refer to the following pages for conditions of this permit. Page 3 of 3
co
o CONCRETE Gas Piping MANUFACTURED HOME 4
No Interior-Date By O
N Footings 1 Setbacks Extergr-Date By Ribbons 0
ic
o Date By INSULATION Gate By D
rn Foundation Walls BG!SLAB INSULATION Set-up Z
Date By Date By Date By O
FRAMING Floors FIRE DEPARTMENT ic
Date By Date By
Gate By Walls
PLUMBING Date By DECKS
Date By
Groundwork Yau itTANKS
Date
Date By Date sy
Attic
D.W.Y
Date By OTHER
Date By DRYWALL Typo.Date By
Water Line Date BY Type:
Date By Int. Brace Wall Date By W
r
MECHANICAL Date FINAL INSPECTION �
Fire Seperaticn O
m Date By Date Date '
By �" BY N
O
Pass or Request Inspect. w
oType of Insp. FaII Date Date Done By Comments00
-6 2-
CD
N
O
1
n
0
a
o'
Cn
o _
5
N
a
co
3
v
cn
m
0
06/05,12012 0",: 26 3604277466 OL",11PIC HEATING PAGE 01/01
FORM MUST BE COMPLETED IN INK 1��(�1�_ �
PLEASE PRESS HARD
� � PERMIT NO.
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W.Cedar-P.O. Box 186, Shelton,WA 98584
Shelton (360) 427-9670-Belfair(360) 275-4467- Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFO MATION CONTRACTOR I ORMATION ,
Ownr e Company Name
Maili g Addres Mailing Address eC
City tatec �, Zip Code City tote Zip Code
Phone�nta-�I�gI'Q9 Other Ph. Phone ` L Other Ph.
Lien/Title Holder Contractor Reg�� ep.
E mail address E Mail Address'- -��¢� C
Drivers Lic.# DOB Drivers Lic.# DOB
SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System
Name of Sewer System
PARCEL INFORMATION - 12 Digit Parcel No. .Fire District
Legal Description
Site Address (Please include street name, street number and city) �_t.iVe E
Directions to site
Is property within 200'of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15%
TYPE OF JOB - New Add Alt Repair Other Use of Building
Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garaq P Closet
PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type-Electric LPG-- Natural Gas— Heat Pump_
Toilets Type of Unit No_ of Units Fees
Bathroom Sink Fumace
Bath Tubs Heatpumps
Showers Spot Vent Fan
Water Heater Propane Tank _
Clothes Washer Gas Outlets
Kithen Sinks Wood/Gas[Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
G/VNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.{declare that I am the owner,owners legal representative,orthe contractor,l further declare that I am entitled to receive this
taermit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary patties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection,
P OF CONTINUATIO ,O WORK IS BY MEANS OF A PROGRESS INSPECT) N.
X ners e Date: -
er/Owpresentative/Contractor (indicate which one)
FOR OFFICIAL USE BEY NDTHIS POINT
Accepted Planning Pd Ck# Date Bld Pd_ Receipt No.
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Ruilding Department
Occ Group—Type Constr.
Planning Department
LF-nvi,onmental Health DepartmentFEES
mbin & Base Fee Site Inspection
Mechanical & Base fee UFO Plan Review Fee
Wood/Gas/Pellet Stove Fee Other
Niolation Fee TOTAL FEES