Loading...
HomeMy WebLinkAboutBLD2008-00730 Cancelled Remodel - BLD Permit / Conditions - 1/11/2009 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 r Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2008-00730 OWNER: DALE MCDANIEL RECEIVED: 6/13/2008 CONTRACTOR: MONNIER CONSTRUCTION 427-5052 790-1934 LICENSE: MONNICL994CN EXP: 2/13/20 ISSUED: 7/11/2008 SITE ADDRESS: 567 E POINTES DR WEST SHELTON EXPIRES: 1/11/2009 PARCEL NUMBER: 121195300156 LEGAL DESCRIPTION: HARTSTENE POINTE#4 LOT: 156 S 29/208 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Remodel / lift roof Harstene Point. General Information Construction &Occupancy Informattirk ISquare Footage Information No. of Bedrooms: 1 Type of Constr.: B Type of Use: SF Insp. Area: No. of Bathrooms: 1 Occ. Group: 3 '' o ze: Deck: Type of Work: ALT Fire Dist.: 5 No. of Stories: 1 Occ. Load: ing:261 Valuation: Building Height: O c. St s: P Basement: Manufactured Home Informatio Setback Infor at n Shoreline& Planning Information Make. Length: t. Front: F . \Shoreli Water Body: SEPA?: Model: Widthi (Ft. Rear: Slo e: Ft.Model: Width: Shoreline Desig.: Side 1: Year: Serial No Side 2 Comp. Plan Desig.: Plumbing Fixtures Me al fixtures FEES Type ty. Type Qty. Type By Date amount Receipt Lavatories 1 Ventilation Fan 1 Plan Check Fee KKK 6/13/2008 $117.81 S2200800008 Showers Building State Fee ARC 6/19/2008 $4.50 S220000 Water Closets (Toilets) 1 Building Permit Fee ARC 6/19/2008 $181,25 S22008000 Mechanical Fee ARC 6/19/2008 $8.40 S22008000 Mechanical Base Fee ARC 6/19/2008 $26.60 S220080o0 Plumbing Fee ARC 6/19/2008 $24.30 S22008000 Plumbing Base Fee ARC 6/19/2008 $23.10 s22008000 Total $385.96 BLD2008-00730 Please referto the following pages for conditions of this permit 1 of 4 CASE NOTES FOR BLD2008-00730 CONDITIONS FOR BLD2008-00730 1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such�ct with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There arepqtential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1- - 4 -0 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X N 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be grant addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building De nt or t any further inspections being performed or approvals granted. X 4) OwT5F,7Ag1 t is,responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. Thqpzrmit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or re ova a . roved documents will result in failure of required building inspections. X 6) All exterior all cav s xposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspected prior to covering. X 7) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED T M OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X 8) Existin ro f shall be insulated to a minimum of R___30 if: The roof is uninsulated or insulation is removed to the level of the sheating, OR All insulation in th roo ei as previously installed exterior to the sheating or nonexistant. X BLD2008-00730 Please referto the following pages for conditions of this permit. 2 of 4 9) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor).-0.35, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: 0 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the unde o e oof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X r1t, , 10) Per 2003 IRC- SECTION 1609 -WIND LOADS- 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BAS D� PEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X 11) Per IRC - SE ION R905 - REQUIREMENTS FOR ROOF COVERINGS- R905.1 Roof covering application. Roof coverings shall be applied in acco(d�applicable provisions of this section and the manufacturer's installation instructions. X 12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the Sta Wa ton. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in pe it r v tiom X 13) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be locatp4 within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your pr c . 2\_� 14) All chan es to"a ved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinan a or gu � n, must be reviewed and approved by Mason County prior to construction. X - 15) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The constructi n of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the int natio al codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector II be ad prior to requesting additional inspections. X BLD2008-00730 Please referto the following pages for conditions of this permit. 3 of 4 16) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a al inspection or to obtain approval will be documented in the legal property records on file with Mason County as Bing non-compliant with Ma n rdinances and building regulations. X 17) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a p oexceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holde vi� nted action from being taken. No more than one extension may be granted. X 18) Pressure ted wood manufactured after January 1, 2004 mTay contain high concentrations of copper which could quickly corrode metal fasteners, X rid flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 19) Landin s d sta s must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Ap rove i e a "to ensure these structures are shown and meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The own the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described pe and stru ure for i wand spection. OWNER OR AGENT. DATE: BLD2008-00730 Please referto the following pages for conditions of this permit. 4 of 4 o CONCRETE MECHANICAL MANUFACTURED HOME n 0 Date 7� Z� O � C) Footings !Setbacks Gas Piping By/,/ Ribbons D CD o Interior Date By interior-Date By Data By Z o Exterior Date By Exterior-Date By Set-up r Point Load!Isolated Footings INSULATION Date By v BG 1 SLAB INSULATION D Date By Data By FIRE DEPARTMENT m Foundation Walls Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Data By % PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwork Attic Date By Date By Type. Dale t3; 0MV DRYWALL Type- Int.Brace Wail Date By Date 2 Date By FINAL INSPECTION CD Water Line Fire Se ration G �8 Date By j Data By Dato Z- — Bye, O m t?0 Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments w CD C c T � ,off �l Irao Ili if rh l�Lv Al�/ CD o r 3 �- N N CD (D -y.