HomeMy WebLinkAboutBLD2013-00320 Mechanical - BLD Permit / Conditions - 5/30/2013 Inspection Line(360)427 -:"�,2
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. :j52
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Shelton, WA 98584
i�
MECHANICAL PERMIT BLD2013-00320
OWNER: DORSEY HOLT RECEIVED: 5/2/2013
CONTRACTOR: PRICE JONES LLC 360.377.6119 LICENSE: EXP: ISSUED: 5/2/2013
SITE ADDRESS: 430 E POINTES DR EAST SHELTON EXPIRES: 11/2/2013
PARCEL NUMBER: 121195300022
LEGAL DESCRIPTION: HARTSTENE POINTE#4 S 28/199 PCL 1 OF BLA#04-40 PTN LOTS: 22 & 183
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DUCTLESS HEATPUMP
General Information Setback Information
Front: Ft. Shoreline: Ft.
Type of Use: SF Insp.Area:
Rear: Ft. Slope: Ft.
Type of Work: MEC Fire Dist.: 5
Side 1: Ft.
Valuation:
Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Heat Pump 1 Mechanical Permit Fee TW 5/2/2013 $18.20 S220130000(
Mechanical Base Fee TW 5/2/2013 $28.50 S220130000(
Total $46.70
BLD2013-00320 Please refer to the following pages for conditions of this permit. Page 1 of 3
CASE NOTES FOR
BLD2013-00320
CONDITIONS FOR
BLD2013-00320
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-8 47-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) OwnerrAgent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X to
3) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
per evocation.
X
BLD2013-00320 Please refer to the following pages for conditions of this permit. Page 2 of 3
4; Installation of heating equipment in a single-family re=.,cence shall meet the requirements of the current Washingto state Energy Code, applicable
sections of the IRC and IMC.
Heating equipment shall be sized in accordance to IRC. Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems
are required and shall be calculated in accordance wit`, accepted practice, including infiltration and ventilation. Design calculations shall be available for
inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181Aand shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal
ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or
rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in
accordance to WSEC Section 1411.
X
5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Ma County ordinances and building regulations.
X
6) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
act" n fora period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
hole prevented action from being taken. No more than one extension may be granted.
X �Y
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate
and grants employees of Mason nt es to the above described property and structure for review and inspection.
OWNER OR AGENT: DATE: ^ �[
BLD2013-00320 Please refer to the following pages for conditions of this permit. Page 3 of 3
r- Gas Piping 'O
o CONCRETE ! MANUFACTURED HOME
o Interior-Date By - .. �__ 0
u, Footings I Setbacks Extenar_bate By Ribbons
o Date By i Date By
w INSULATION O
o Foundation Walls BG ISLAB INSULATION Set-up Cl)
Date By Date By Date By M
FRAMING Floors FIRE DEPARTMENT
Da to By
Date
Date By 6 y
Walls --
PLUMBING pate By DECKS
Date By
Groundwork Vault TANKS
Date By
D Date ey
Date By
Attic
D.W.v
Date By OTHER
Date By DRYWALL Typo.Date By
Wator Lim Date BY Type:
Date By Int.Brace Wall Date 8.
Cn MECHANICAL Date _ By FINAL INSPECTION N
m ~Fire Seperation ®-� O
Date By Date ay D-ite ✓ By / W
1 O
z Pass or Request Inspect. CD
W
Type of Insp. Fail Date Date Done By Comments c
OF
. xs
o
a
o'
N
0
r
'0
�R
3 ---
0
PERMIT
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W. Cedar- P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-96 0-B elf ww3w 0) 275 on67*Elma(360) 482-5269
APPLICANT INFORNTI � CONTRACTOR INFORMATION
Owner 3 "•�' Company Name F L L
Mailing Add/r� 1Pther
Mailing Address11.Cit �l '� Code 1 `� C City. _ State { Zip Code-:S 3`��
Phone = ' �"����z O per Ph.
h. Phoneme ?
Lien/Title Holder Contractor Reg. #> ' t 7L Exp. /
,.,_F. /.
E Mail Address - f"���- -
E mail address -4 F �^-
DOB_'__
Drivers Lic. # _ DOB Drivers Lic. #
SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System
Name of Sewer System
PARCEL INFORMATION- 12 Digit Parcel No Fire District
Legal Description
Site Address (Please include street name, street number and city)
Directions to site
Is property within 200' of Saltwater Lake River/Creek o Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15/o
TYPE OF JOB - New__ __ Add___Alt Repair__Other Use of Building
Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG_Natural Gas_Heat Pump_
Toilets Type of Unit No. of Units Fees
Bathroom Sink Furnace
Bath Tubs Heatpumps r.j/c;'Z
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kithen Sinks Wood/Gas/PelletStove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other parry in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF OFICONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECT��_
r
X ,, � Date:
Owner/Own@rs Representative/Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by:_ Planning Pd_ __ _Ck# __,Date_ _ _ __ __Bld Pd______Receipt No.---
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Occ Group-Type Constr.
Planning Department
Environmental Health Department
FEES
Plumbing & Base Fee Site Inspection
Mechanical & Base fee UFC Plan Review Fee
Wood/Gas/Pellet Stove Fee Other
Violation Fee TOTAL FEES