HomeMy WebLinkAboutBLD2008-01317 Pole Bldg - BLD Permit / Conditions - 11/13/2008 Inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg, III 426 W. Cedar P.O. Box 186
Shelton, WA 98584
P14
RESIDENTIAL BUILDING PERMIT BLD2008-01317
OWNER: RICARDO GARCIA RECEIVED: 10/23/2008
CONTRACTOR: TOWN & COUNTRY POST FRAME BLDS 425-743-1555 LICENSE: TOWNCPF099LT EXP: ISSUED: 11/13/2008
SITE ADDRESS: 4147 E GRAPEVIEW LOOP RD GRAPEVIEW EXPIRES: 5/13/2009
PARCEL NUMBER: 121082290093
LEGAL DESCRIPTION: PCL 2 OF BLA#07-19 PTN TR 9 OF NW NW S 33/119
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Construct pole building. Stock Plan #2006-0014 West on Grapeview Loop from stop sign by fire station post office, gravel
driveway to right where GLR bends south, stay left up hill.
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck:
Type of Work: ACC Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building: Garage-Detached 864
Valuation: Building Height: Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline& Planning Information
Make: Length: Ft. Front: E 254.0 Ft. Shoreline: Ft. Water Body:
Rear: W 30.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: N 70.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: S 223.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee CMH 10/23/200 $75.45 B12008000
Planning Review Fee CMH 10/23/200 $190.00 B12008000
Building State Fee MAL 10/28/200 $4.50 612008000
Building Permit Fee MAL 10/28/200 $377.25 612008000
EH Plan Review CEW 10/29/200 $40.00 612008000
Total $687.20
BLD2008-01317 Please refer to the following pages for conditions of this permit. 1 of 5
CASE NOTES FOR
BLD2008-01317
CONDITIONS FOR
BLD2008-01317
1) Owners
X responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
2) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revoc
X
3) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or �i ' must be reviewed and approved by Mason County prior to construction.
X_
4) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents a e removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be
charged and shall lected by the Building Department prior to any further inspections being performed or approvals granted.
X 00
5) Prior to final approval, all upland areas disturbed or newly create onstruction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X
6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international c des as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be a prior to requesting additional inspections.
X
7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X
8) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final iq pection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason Coun nances and building regulations.
X
BLD2008-01317 Please referto the following pages for conditions of this permit. 2 of 5
9) The use, handling and storage of ha W
terials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of
the Mason County Fire Marshal. X
10) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. All
applicable recommendations and specifications shall be applied to the development on this site. Any deviation requires stamped written approval from the
registered design professional responsible for the report/assessment, and may require special inspection by same. Structures and/or land modifications
(grading, cuts, f Is, etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment shall
remain att to the approved building plans.
X
11) All activities I ed to this permit are subject to the recommendations made in the geotechnical report prepared by E3RA, dated January 29, 2007.
X
12) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved Sit I "to ensure these structures are shown and meet the setback conditions listed.
X
13) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X
14) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prev ction from being taken. No more than one extension may be granted.
X
15) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of appe ocuments will result in failure of required building inspections.
X
16) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building
Department any further inspections being performed or approvals granted.
X
17) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, WX
ing. Install metal connectors approved for contact with the new types of pressure treated material.
X_-
BLD2008-01317 Please referto the following pages for conditions of this permit. 3 of 5
18) All property lines shall be clearly identified at the time of foundation inspection. X
19) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647 j- The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
20) Retaining walls needed to support a surcharges structures, roads, or to support slopes, shall require a separate building permit and approval prior
to construction of the retaining wall. X
21) Per IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS- R905.1 Roof covering application. Roof coverings shall be applied in
accordance wj a applicable provisions of this section and the manufacturer's installation instructions.
X
22) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum wind load prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609
BASIC WIND D (3-SECOND GUST) the wind speed for Mason County is 85 MPH.
X
23) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be ranted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
X
Building De prior to any further inspections being performed or approvals granted.
24) Stock Plan Identification number: 2006-01314
This project is approved subject to the provisions identified the Mason County Stock Plan Policy. The site plan approved by the Planning Department,
original building plans, and all attachments approved by the Mason County Building Department shall be available for the Mason County Building
Inspector at e uired inspection.
X
25) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor is owledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X
26) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international s and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved.
X
BLD2008-01317 Please refer to the following pages for conditions of this permit. 4 of 5
27) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit:�h applied for, reviewed and approved prior to the change.
X
28) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. All
applicable recommendations and specifications shall be applied to the development on this site. Any deviation requires stamped written approval from the
registered design professional responsible for the report/assessment, and may require special inspection by same. Structures and/or land modifications
(grading, cut i etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment shall
remain at o the approved building plans.
X
29) An inspection performed by a representative of the geologist, their authorized representative, or engineer of record, shall be completed on-site prior to the
footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations.
In addition a final inspection report, prepared by a representative of the geologist, their authorized representative, or engineer of record shall be required
to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations.
Reports shall be submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584, prior to the footing and final inspections and available
for inspection. ��
X
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and s ructur for vi w nd inspection.
OWNER O GET DATE: C
BLD2008-01317 Please referto the following pages for conditions of this permit. 5 of 5
MASON COUNTY PERMIT NO.
BUILDING PERMIT APPLICATION
(� 426 W. Cedar • P O. Box 186, Shelton, EA1 498584 ,^'�V
S f1CX n iU Shelton (360) 427-9670 • Belfair (360) 275 46 • a (360) 82 5269 d►IM`
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner Company Name I LXvN 4 L N'TV{ &11- i>f iyGS
Mailing Address t ' Mailing Address I^ t W
City "+ ` " W tat Zip Code City State Zip Code
Phones 'Other Ph. Phone ' ��1 Other Ph. — -
Lien/Title Holder N I FA Contractor Reg. N C-1' O`t' Exp.
E mail address E Mail Address
Drivers Lic.# i� 'A DOB Drivers Lic.# DOB
SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well Water System Name of Water System
PARCEL INFORMATION- 12 Digit Parcel No. Fire District
Legal Description r_ 1' _'F G A
Site Address (Please include street name, street number and city)
Directions to site - i L`ti ' i' 1 Ili, a i 40 N t:5 1 9 �1ATI(jN ro��
Wj lG, it tt104PRi '3ENI5" -QV'TH TAY LEFT UVNi:
Will timber be cut and sold in parcel preparation?Yes No
Is property within 200'of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15%
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No"
TYPE OF JOB -,New Add Alt Repair Other RIMARY RESIDENCE [�.,PgASPNAL ❑
Use of Building C Describe Work i ,Tt, `'� r�
No.of Bedrooms No.of Bathrooms Square Footage - 1 st Floor 2nd Floor
3rd Floor Basement Deck Covered Deck Other Sq.ft.
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make N I N Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit? Yes/ No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and insR�on.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. OCR; 2 3 Z1U�
X Date OFFICE Owner/Owners Representative/Contractor indicate which one R
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department D O
Planning Department
Environmental Health Departmen
Public Works Department
Fire Marshal
FEES
Building Permit Fee 577 z Site Inspection
Plan Review Fee j�S EH Review Fee
Plumbing & Base Fee Planning Review Fee
Mechanical & Base fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation $ Z Q z" TOTAL FEES
Name Parcel# B
ba
R Mason County -r
'n(]8 Department of Community Development'wA G F-
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface'.
'Redevelopment means, on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity, and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways, parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area " All dimensions in feet
Buildings X ;Z =
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example:
eaves/gutters)
X =
Driveways X
X = Length of drive begins at the right of way
X =
Parkinq Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X
X = Any paved, gravel or packed area per definition
above table
X
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas) G
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further
acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-described
property for r iew and ins ection as may be required.
X Owner/Agent/Contractor(circle one)Date: I O ?: ws
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2. RE cEIV
OCT9 ED
Page I of 2 P 3 2
0
90
8E[F-4l
CE
Name Parcel # BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC) regulates compliance requirements for Stormwater
Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website:
http//w,Aw.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to "Title 14, Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you
in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public
Works this document will constitute an approved plan if all of the relevant details* are to be installed in their
entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will.be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
Mail: P 0 Box 1850, Shelton WA 98584
Physical: 415 N 6th St, Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel. You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone: (360)-427-9670 EXT. 352
Mail: P 0 Box 1666, Shelton WA 98584
Physical: 426 W Cedar St, Shelton WA 98584
A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative, or the contractor. I further
acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-described
property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
Page 2 of 2
12/05/2008 FRI 12: 39 FAX 425 742 4378 PERMABILT 14001/001
IL
Town&Country
�e>sr POST FRAME BUILDINGS Su to C•76521 Highway 99•Lynnwood,WA 96037.3161
Everett:(425)256.4171 Puyallup:(743)640.9552Adm Building Design
a-*�A_ FAX:(425)ve2-4378 er,ars: e: 1-843-t665
�3 PERMABILT FAX: (425)742-4378 Toll Free: 1-800-924s552
(�uality:Our Future Depends Oe it.'" Contractor's Uo.#:TOWNGPF099LT
s
t
• i
PLEASE CHECK FLOOR PLAN oil-up doors fit in Bays � Wind MPH Draw North An-ow in Circle
Roll-up doors will not hit T"ll truss engineering must _ Wind Exposure
+1 Roof Pitch U Eave Height
Snow Load be available on site at W Minimum Clearance
i 1";� Q�i}�-�It'r!�t`+�.'; f i } i _. �—.'• — i -`-1
i •
-
J— _. -• --- -
} l ,
- '
i
�-- �t
•"` + 'A .:tiu 'Lit _-A. umi 4A n
t '— — --- --• --- _ � � ".,.:,.,.9.,.�w =.-.,era
t
t t—._..
p ! I
L.A
4
--
WINI
i___# ..____-I___ I �.-------.
BUILDING ELEVATION
Customer has verified and approved the orientation of the building to the North and verifies that all items specified in Paragraph B of the contract are
shown on this drawing and vice versa. Customer Name: C ' =I A Lead# /1 (9
Customer Si a
! I1,'1I'Itttre
I'1I I'lI White-Customer Copy Canary-Office Copy 7 01995 Perma-gilt Industries FR-85 6/07
( 2� o S Z2-9v04 3 F`
6�/� _
07-rA UP
S = a
*41 6e1✓ e S 1731..
E
Full truss enginc-ering
site rat st DST—
be
available
fray ling inspection.
REVISE
DATE 1 oS D
�nA�e'..,,._�C*a�! n ma`s•
MASON BUILDING INISRECTOR
CHANGES SUBJECT Ti AP ROV L
nTr