Loading...
HomeMy WebLinkAboutBLD2019-00387 SFR - BLD Application - 4/19/2019 I cot,n MASON COUNTY COMMUNITY SERVICES Permit No6\daD\�- PERMIT ASSISTANCE CENTER: r ' •BUILDING •PLA PUBLIC HEALTH•FIRE MARSHAL 14 615 r`et,�Belfair:,.(3&0)275- I 98584 gym' 1-� RECEIVED t Phone Shelton:(360)427-9670 eexV21 427-7798 Phone 4457•phone Elma:j 482-5269 i,w;� APR 19 2019 BUILDING PERMIT APPLICATION 615 WAlder Street PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: John Cole NAME: J&J Development LLC MAILING ADDRESS: 1118 7'Ave NW A-313 MAILING ADDRESS: PO Box 623 CITY: IssNuah STATE: WA ZIP: 98027 CITY:Burley STATE: WA ZIP:98322 PHONE#1: 206-557-8464 PHONE: CELL: 253-549-3913 PHONE#2: EMAIL : chuckacedarland-homes com EMAIL: iohn e cole�a gmail com L&I REG# JJDEVJD852QWEXP. 12/6/ 19 PRIMARY CONTACT: OWNER❑ CONTRACTORS OTHER❑ NAME Chuck Lawson EMAI chuck(a cedarland-homes com MAILING ADDRESS PO Box 623 CITY Burley STATE WA ZIP 98322 PHONE CELL 253-549-3913 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 12218-50-00045 ZONING LEGAL DESCRIPTION(Abbreviated) Lot 45 Lakeland Villaize#12 Phase 11 FIRE DISTRICT SITE ADDRESS 630 E Sodderberg Rd CITY Allyn DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%:YES❑ Z IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWAnlE ❑; Axe% ❑RIVER/CREEK EK❑POND❑WETLANaD SEASONAL 1� g ❑s�rr.�ANI❑ TYPE OF WORK: NEW ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Gar�E, ommercial Bldg,Etc.)Residence IS USE: PRIMARY SEASON NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(Whole Bldg) ❑ YES(part[sJ of Bldg) ❑ NO ❑ DESCRIBE WORK New Construction—SFR SQUARE FOOTAGE: (propose+existing) I ST FLOOR 1760 sq.ft.2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq. ft. DECK sq.ft.COVERED DECK 288 sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE 868 sq.ft. Attached Detached❑ CARPORT sq.ft.Attached❑Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC ❑ SEWER% / NEW ❑ EXISTING ❑ PLUMBING IN STRUCTURE? YES-& NO�3 Ifyes, attach completed Water Adequacy Form PERIMETERNOUNDATION DRAINS PROPOSED? YES ❑ NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS 3 TOTAL BEDROOMS—31 — OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 18'0 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON COUNTY CODE 14.08.42) X Oriol � 1 j Date Si ature of OWN�R(Must be signed by the OWNER) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: / •BUILDING •PLANNING •FIRE MARSHAL • 615 W. Alder St- Shelton, WA 98584 V www.co.mason.wa.us /1°�•®e Phone Shelton: 360 427-9670 ext. 352•Fax: (360)427-7798 RE CEI`/ Phone Belfair:(360)275-4467•Phone Elma:(360)482-5268 y E PLUMBING & MECHANICAL PERMIT APPLICAAINN1 9 2019 OWNER INFORMATION• CONTRACTOR INFOR . __ ►Ider Street NAME: JOHN COLE NAME: J &J DEVELOPMENT LLC MAILING ADDRESS: 1118 7Ta AVE NW A-313 MAILING ADDRESS: PO BOX 623 CITY: ISSAQUAH STATE: WA ZIP: 98027 CITY: BURLEY STATE: WA ZIP: 98322 1'PHONE: 206-557-8464 PHONE:253-549-3913 CELL: 2°d PHONE: EMAIL : chuck cedarland-homes.com EMAIL:John a coleaa gmail com L&I REG#JJDEVJD852OW EXP. 12 /6 / 19 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number): 12218-50-000457 Zoning: LEGAL DESCRIPTION(Abbreviated): LOT 45 LAKELAND VILLAGE#12 PHASE II SITE ADDRESS: 630 E SODERBERG RD CITY: ALLYN DIRECTIONS TO SITE ADDRESS: TYPF. OF JOB: NEW X ADD ALT REPAIR OTHER USE OF BUILDING RESIDENCE LOCATION OF FIXTURES/UNITS—1ST FLOOR X 2ND FLOOR BASEMENT GARAGE X OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG X Natural Gas—Ductless— Toilets 2 Tvne of Unit No.of Units Fees Bathroom Sink 3 Furnace 1 - Bath Tubs 1 Heat Pump 1 Showers 2 Spot Vent Fan 5 Water Heater 1 Propane Tank 1 Clothes Washer I Gas Outlets 5 Kitchen Sinks I Wood/Gas/Pellet Stove 1 Dishwasher I Kitchen Exhaust Hood I Hose bibs Other 2 Dryer Vent I WarPanel Base Fee Other TOTAL PLUMBING Base Fee TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void �f work or authorized construction is not commenced within 1-80 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS -9IJILWNG DEPARTMENT '�L (0 2(l PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/201b JBN APR 19 19 ' N 87'2527" E 192.45 615 W, Alder o-eet W I 60 I ry ko HOUSE 46 00 I [6501 I I N 78.97 co 1" = 60' $ o IVEWAY 45 e for o oE [s30) A CO kpTo MASON r.uEQ�' To Sj i pNP ;VB g S N 872527"" 95 Date rn N zl QI J I O BY I rn I to I 44 cn O I tH O ~ NOTE o BY AND WL�G °�N N�� n. (6101 E MEASI) N 87.25.27" E 188.93 WA sr�r�JETBACKS At C-tTt-tE�T � SAKI Y SEWER RRC)M THE� p? 11 ..DQ ALL SETV7 Sall i;j tv ` I goo HOUSE 43 io co w I � LEGAL DESCRIPTION 4i LOT 45 OF I LAKELAND VILLAGE 112 PHASE 9 ( [590) N N AP No. 12218-50-00045 60 N 8725'27` E 190.13 N o ADORESS z 630 E SOOERBERG RD CEDARLAND HOMES LLC ALLM, WA. 98524 GIG HAR" WA 98335 (253) 208-8136 v - SITE PLAN MAP AGATE LAND SURVEYING, PLLC :B� Fc"p, PROFE59MAL LAND SURWYVR F WA,,!°� _ Ill, FOR 2680 E. AGATE R0. - P.R BOX 246 4e CEDARL AND HOMES LLC SWIM WA98584 - (360) 426-4172 �i IN THE DRAWN 8Y ATE:03/18/2019 ,X6 W. 4094 04 J 282137w NV14 NE114 Mee \`�Ss• gF�TST .VLV. 14� SCALE l lNCN =60" 7 1 OF 1 , Rl iN, W.M. CHECKED BY SEC �8 TZ2N •r ,SW FILE NO.- 4094—CH—SITEPLAN.ONG RECEIVED ,6\(� APR 1 g 19 N 78 -2S 27" E 192.45 615 W, Alder met 60 i ' N co HOUSE 46 `" °� 8 [6501 I N - 7 �E 1" = 60' $ 1 VEWAY 45 'PROVED PUBLIC HEA!_ w j 5oT' w J U N 2 5 ? lq [630] rn � N 872527" 95 m o N Irn z� o rn J f Owl I � 44 � W to NOTE. a I w POTABLE WATER PROWDED [610] BY LAKELAND VILLAGE I I WATER SYSTEM. I N 87'25'27" E 188.93 SANITARY SEWER BY ALLYN SEWER SYSTEM. rn ' HOUSE U 43 to Io LEGAL DESCRIPTION W LOT 45 Of It LAKELAND VLLAGE 112 PHASE fl [5901 AP No. 12278-50-00045 50 N 87'25'27" E 190.13 N o ADDRESS I 2 630 E SODERBERG RD ALLYN, WA. 98524 CLDARLAND HL)MES LLC GIG HAR". WA 98335 (253) 206-8136 SITE PLAN MAP AGATE LAND SURVEYING, PLLC BEC 7,. PROFES-90AL LAND S1/RWYM f �, or wasp ,�E f FOR 2680 E. AGATE RD. - P.R BOX 246 �! J CEDARtAND HOMES LLC SHELTM WA 9�esM4 - (360) 426-41n T o; IN THE DRAWN BY ATE:03/18/2019 J08 W. 4094 28237 w NE1/4 NE1/4 MJ8 �s ISTF. ��� SCALE 1 INCH =60' L. 1 OF 1 1,A_ SEC 18 T22N Rl W W M. CHECKED Br SGB RLE NO. 4094-CH-SHEPLAKONG MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/Ventilation Code Compliance Application Submit with heating/cooling system size worksheet vt Owner: J & J DEVELOPMENT LLC Parcel#: 12218-50-00046' Type of project: NEW CONSTRUCTION Total Sq. Ft. 1 st Floor : 2"d floor: Heated Basement: of heated area:: 1760 1760 Heating System Type: O Electric wall heater O Electric Central FurnaceJQ:C�G Furnace O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: O Prescriptive Option Table R402.1.1 (see table on previous page) Compliance Method O Component Performance, R402.1.3 — Calculation worksheets required Must Check one:: O Other (Specify): Check one O Whole House Ventilation system O Whole House Ventilation Ventilatio using exhaust fans &window or wall Integrated with a Forced Air O Other, describe: fresh air vents (M1507.3.4). If using System (M1507.3.5) n System window vents be sure to order windows with vents. Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements,"all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/iecc wsec.pdf Additional a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor area and less than 300 sq. ft fenestration area (skylights, doors, windows,etc). Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor Efficiency Requirem but less than 1,500 sq ft of floor area. Requires 1.5 credits ents b) Medium dwelling units that are not included in (a) above (small dwelling), OR (c)below Energy {large dwelling) Requires 3.5 credits credits EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5 required: credits. See page two for description. 3.5 c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area. Requires 4.5 credits d) Additions less than 500 sq feet. Requires .5 credits (Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. Describe Energy Credit Option(s): Using Option - EFF BLDG ENVELOPE number(s): - HIGH EFF HVAC - EFF WATER HEATING 1 a, 3a, 5a, 5c 3 Table 406.2 Energy Credits 2015 Code PTIO DESCRIPTION CREDIT(S) Estimated Cost 1 a EFFICIENT BUILDING ENVELOPE la: 0.5 Prescriptive compliance�on Table R402.1.1 with the following modifications: Verti tration U 0.28 Fl r R-38 Slab grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section 402.1.4- Reduce the Totat VA by 5%. lb EFFICIENT BUILDING ENVELOPE lb: 1.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.25 Wall R-21 plus R-4 Floor R-38 Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or " Compliance based on Section R402.1.4: Reduce the Total UA by 15%. I C EFFICIENT BUILDING ENVELOPE lc: 2.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.22 Ceiling and single-rafter or joist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 Basement wall R-21 int plus R-12 ci Slab on,grade R-I0 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 30%. Ida EFFICIENT BUILDING ENVELOPE Id: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.24 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 Compliance based on R402,4.1.2: Reduce the tested air leakage-to 3.0 air changes per , hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a high efficiency fan(maximum 0.35 watts/cfm),not interlocked with the furnace fan.Ventilation systems using a furnace including an ECM motor are allowed,provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the quali ingventilations stem. 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.70. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilations stem. Table 406.2 Energy Credits 2015 Code OPTION DESCRIPTION CREDIT(S) Estimated Cost 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: 1.5 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.85. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilations stem. 3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0 Gas,propane or oil-fired furnace with minimum AFUE of 94%,or Gas,propane or oiled-fired boiler with minimum AFUE of 92% To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3b HIGH EFFICIENCY HVAC EQUIPIVIENT 3b: Air-source heat pump with minimum HSPF of 9.0 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3c b HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5 Closed-loop ground source heat pump;with a minimum COP of 3.3 or Open loop water source heat pump with a,maximum pumping hydraulic head of 150 feet and minimum COP of 3.6 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3d' HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0 Ductless Split System Heat Pumps,Zonal Control:In homes where the primary space heating system is zonal electric heating,a ductless heat pump system shall be installed and provide heating to the largest zone of the housing unit. To.,qualify to claim this credit,the building,permit drawings shall specify the caption being selected and shall specify the heating equipment type and the minimum equipment efficiency. k HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: 1.0 All heating and cooling system components installed inside the conditioned space. This includes all equipment and distribution system components such as forced air ducts,hydronic piping,hydronic floor heating loop,convectors and radiators.All combustion equipment shall be direct vent or sealed combustion. For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of supply ducts may be located outside the conditioned space.All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections must be made with nylon straps and installed using a plastic strapping tensioning tool. Ducts located outside the conditioned space must be insulated to a minimum of R-8. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat and ductless heat pumps are not permitted under this option. Direct combustion heating,equipment with AFUE less than 80°/a is not permitted under this option. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. Table 406.2 Energy Credits 2015 Code OPTI DESCRIPTION CREDIT(S) Estimated Cost Sa EFFICIENT WATER HEATING 5a: 0.5 All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads,kitchen sink faucets,and other lavatory faucets. 5b EFFICIENT WATER HEATING 5b: 1.0 Water heating system shall'include one of the following,: Gas,propane or oil water heater with a minimum EF of 0.74 or Water heater heated by ground source heat pump meeting the requirements of Option 3c. or For R-2 occupancy,a central heat pump water heater with an EF greater than 2.0 that would supply DHW to all the units through a central water loop insulated with R-8 minimum pipe insulation. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. 5c EFFICIENT WATER HEATING 5c: 1.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.91 or Solar water heating supplementing a minimum standard water heater.Solar water heating will provide a rated minimurn savings of 85 therms or 2000 kWh.based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems or Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and,for solar water heating systems,the calculation of the minimum enrTgy,savings. 5d EFFICIENT WATER HEATING 5d: 0.5 A drain water heat recovery unit(s)shall be installed,which captures waste water heat from all the showers,and has a minimum efficiency of 40%if installed for equal flow or a minimum efficiency of 52%if installed for unequal flow.Such units shall be rated in accordance CSA B55.1 and be so labeled. To qualify to claim this credit,the building permit drawings shall include a plumbing diagram that specified the drain water heat recovery units and the plumbing layout needed to install it and labels or other documentation shall be provided that dentottstrates that the unit complies with:the stattdard. Table 406.2 Energy Credits 2015 Code OPTION DESCRIPTION CREDIT(S) Estimated Cost 6 RENEWABLE ELECTRIC ENERGY: 0.5 For each 1200 kWh of electrical generation per each housing unit provided annually by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits. Generation shall be calculated as follows: For solar electric systems,the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PV WATTs. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based ion4he"owing-Factors: The wind turbine power curve;average annual wind speed at the site;frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, provide documentation of solar and wind access,and include a calculation of the minimum annual energy power production. Name J&J DEVELOPMENT Parcel# 12218-50-00048 BLD# Mason. County ECEIVEp Department of Community Development Art? 19 2019 Small Parcel Stormwater Management Application/Workslly lk(gage 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for th§development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC).regulates compliance requirements r ater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason Cout�y ' http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Departmesit of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AM no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" ELEASE INITIAL HEtOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THISSITE A) X The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County`s Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the�stormw-atersystem will not.adversely.affect the-septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail:P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that th information provided is accurate and employees of Mason County are granted access to the above- described overly for re ew and i tion as may be required. X (�/,/ Owner/Agent/Contractor(circle one)Date: Page 2 of 2 Name J&J DEVELOPMENT Parcel# 12218-50-00048 BLD# . Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment', with more than 2,000 square feet of impervious surface,. "Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include, but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings 62 X 52 3224 X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways 50 X 34 = 1700 X = Length of drive begins at the right of way x = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks 24 X 6 = 444 X = Any paved, gravel or packed area per definition above table X = Others X = X If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 5068 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information f 631'. E Soderberg Rd Chuck Lawson Allyn 253-549-3913 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Valuea' LI-Factory Fenestration U-Factor' n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb° n/a n/a Ceilingk 49i 0,026 Wood Frame Wall9,m,n 21 int 0.056 Mass Wall R-Value' 21/21b 0.056 Floor 309 0.029 Below Grade Wall°m 10/15/21 int+TB 0.042 Slab R-Value&Depth 10, 2 ft n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential buildina shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1.Small Dwelling Unit: 1.5 credits Q Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. �. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3.Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. C3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 0.5 lb Efficient Building Envelope lb 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 31b High Efficiency HVAC 3b 1.0 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Window,Skylight and Door Schedule P"oj"I Oto-'!an 1630 E Soderberg Rd Chuck Lawson Allyn,WA 1253-549..3913 Width Height Ref. U-factor Qt. Feet Feet Area UA Exempt Swinging Door(24 sq.ft.max.) 0.01 0.00 Exempt Glazed Fenestration(15 sq.ft.max.) 001 0.001 Vertical Fenestration(Windows and doors) Component Width Height Des',I prior Ref U-factor Qt Feet Feet Area UA Front Elevator, 1 0.0 0.00 0,28 2 1 5 10.0 2.80 0.28 1 13 6 20.0 5.60 0.28 11 16 4 24.0 6.72 00 0.00 Right Side Elevation 0.0 0.00 0.29 1 15 1 14 1 20.0 5,601 0,28 2 12 j 12 Mo 2.80 I I 1 0.0 0.00 Rear Uevabar 0,28 f 6 4 24.0 6.72 0.28 1 114 1 1 4,0 1.12 0.28 1 13 1 3 10.5 2.94 0.28 1 112 1 8 96.0 26.88 0.28 1 3 6 20.0 5.601 Left Side Elevation 0.0 0,00 0,28 2 2 2 12.5 3.50 i 5 14 20.0 0,00 M 0,00 0.0 0.00 0.0 0.00 0.0 0.001 M 0.00 0.0 0.0 0,0 0,00 0.0 Mo 0.0 0.00 0.0 0.00. 0.0 0.00 0.0 0.00 0,0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.001 M 0.00 0,0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 0.01 0.001 Sum of Vertical Fenestration Area and UA 1 271.01 70,28 Vertical Fenestration Area Weighted U=UA/Area 0.26 Overhead Glazing(Skylights) Component Width Height Dns;mpf,or, Ref U-factor Qt. Feet Feet Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0,00 0,0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.01 0.00 Overhead Glazing Area Weighted U-UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) F-27176 7028 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Reauirements of the 2015 Washington State Eneray Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing coolina systems should be used to determine cooling loads. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information 630 E Soderberg Rd Chuck Lawson Allyn,WA 253-549-3913 Heating System Type: *All ocher systems 0Heat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions rrrrrrrsrrr Design Temperature Difference(AT) 41 Bremerton AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area instructions Conditioned Floor Area(scl ft) 1,760 Average Ceiling Height Conditioned Volume instructions Average Ceiling Height(ft) 15,840 Glazing and Doors U-Factor X Area = UA Instructions U-0.28 �- 0.280 75.88 Skylights U-Factor X Area = UA Instructions 0.50 Insulatio Attic U-Factor X Area = UA Instructions R-49 � 0.026 F 17735 45.11 Single Rafter or Joist Vaulted_Ceilings _ U-factor X Area UA Instructions n�rli� No Vaulted Ceilings in this project. 'Liz Above Grade Walls(see Figure f) U-Factor X Area UA Instructions 0.056 1,691 7 94.70 R-21 Intermediate Elm Floors Ul-Factor X Area UA Instructions R-38 0.025 17760 44.00 Below Grade Walls(see Figure 1) U-Factor X Area UA tic tioais 0.028 No Below Grade Walls in this project.LIJM Slab Below Grade-(seeFVurq 1L _ F-Factor X Length UA Instructions 0.303 --- No Slab Below Grade in this project. � Slab on Grade(see Figure 1) F-Factor X Length UA Instructions No Slab on Grade in this project. � Location of Ducts Instructions - Duct Leakage Coefficient Unconditioned Space L'IS 1.10 Sum of UA 259.69 Envelope Heat Load 10,647 Btu/Hour Figure 1 Sum of UAX AT Air Leakage Heat Load 7,014 Btu I Hour Volume X 0.6 X AT X.018 ",ad. Building Design Heat Load 17,661 Btu/Hour Air Leakage-Envelope Heat Loss Building and Duct Heat Load 19,427 Btu/Hour Duds in unconditioned space:Sum of Building Heat Loss X 1.10 Duds in conditioned space:Sum of Building Heat Loss X i Maximum Heat Equipment Output 27,198 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .=continuous insulation, int .= intermediate framing. Rvalues are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R- 10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. 6 Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. ' Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. 1' Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3.