HomeMy WebLinkAboutSPI2011-00040 - SPI Inspections - 9/21/2011 o4-STA MASON COUNTY
o P� A o N DEPARTMENT OF COMMUNITY DEVELOPMENT
S N Planning Division
P o Y y P O Box 279, Shelton,WA 98584
(360)427-9670
1864
Site Inspection
September 21, 2011 -2-A t 9 or b c so
STEVE POLLINGER TO BE KEPT IN THE
3406 WANDERING MEADOWS PARCEL FILE
AUSTIN TX 78746-1650
Case No.: SP12011-00040
Parcel No.: 121181190150
Project Description: Site Pre-Inspection to determine the location to construct a new
SFR
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below
you will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands
must be included in your specific proposal; these setbacks are included as part of the comments
listed below.
This information is based on County and State regulations as they exist to date. These
regulations may change and may affect the requirements for development of the subject property.
Please contact me at(360)427-9670, ext. 365 if you have questions.
Sincerely,
Allan Borden
Land Use Planner
Mason County Planning Department
9/21/2011 Page 1 of 5 SP12011-00040
Site Inspection
9/21/2011 Case No.: SP12011-00040
Comments:
Pre-inspection for Steve & Lynn Pollinger on Sept. 8, 2011:
This pre-inspection was made to evaluate a property [Parcel No.
12118-11-90150] on Winterwood Dr. and along Case Inlet for a
new residence and other structures. The property has a general
slope of 10 percent in the northwest 450 feet, and 70 percent
slope in the southeast 200 feet. Most of the merchantable trees
on the property have already been harvested, including an area of
150 feet depth at the top of the slope where additional alder,
cedar, and big-leaf maple trees have been removed (per 2009
aerial photo). An eagle management review must be part
proposed development. These findings state regulations in effect
at the time of inspection, unless noted otherwise
Development Regulations standards:
_Y_ The site is in Rural Residential 5 zone. Standard building
setbacks are 25-foot front yard setback, and 20-foot side property
line and rear yard setbacks. These setbacks are measured from
structures above grade such as roof overhangs, stairs, balconies,
decks, heat pumps, storage buildings, and fuel tanks.
_Y_ An exception is made for lots less than 100 feet in width,
where side yard setbacks are equal to 10 percent of the lot width,
but no less than 5 feet; this property has a 5 to 8 ft. side yard
setback, depending on proposed building footprint.
_Y_ An administrative variance may be requested to reduce
these setback distances from property lines, to as low as 5 feet
(side yard) or 10 feet (road easement), if the size, shape, or
features of the property constrain development from the proper
setbacks. This process requires application and review at the
time of the building permit submittal.
Shoreline Setback standards:
Y_ Shoreline setbacks: The shoreline designation for Case Inlet
is Urban Environment per the Mason County Shoreline Master
Program and development setbacks would be determined by the
Mason County Resource Ordinance. The shoreline setback is
typically determined by drawing a line between the roofline of
adjacent neighboring residences across the subject property,
measuring the roof projection closest to the shoreline. Any
portion of the new structure, including decks, balconies, and
rooflines, must be behind this common line. Shoreward of this
9/21/2011 Page 2 of 5 SP12011-00040
Site Inspection
9/21/2011 Case No.: SP12011-00040
line for 15 feet toward the shoreline is an area that may be used
for lawns, patios or landscaping (development at grade level).
From that point toward the shoreline is considered to be a
required vegetated buffer that must remain and is regulated by the
Mason County Resource Ordinance Fish and Wildlife Habitat
Conservation Areas Chapter. Within this chapter are those
activities listed that can be done both with and without a Mason
Environmental Permit; proposed tree limbing and limited cutting of
trees in the buffer for view improvement are reviewed by the area
permit planner prior to starting these type of activities.
Staff met the applicants' representative (father) on the property.
Staff did not measure the common line setback from the ordinary
high water mark of the Case Inlet shoreline to a shoreward roof
eave of a proposed residence; this distance along the north
property line was estimated from the June 2009 aerial photo as
180 feet from the toe of the slope below. The proposed home
would be behind the view common line of the residence to the
northwest (a greater distance), across the subject parcel as a
diagonal, to the north corner of the cabin to the southeast (a
closer distance). As stated above, all portions of the new
development must be behind this shore common line noted at the
site inspection. Note that the setback in this situation is
composed of a minimum vegetation buffer of 100 feet along Case
Inlet and nearly 80-foot building setback immediately in front of
structures proposed above grade.
If additional trees in the vegetation buffer are planned to be
removed or an area replanted, a site plan showing the proposed
trees to be taken down, left in place or removed, and the
configuration of replacement trees shall be submitted for review to
the permit planner.
Two precautions for site development on this property should be
noted:
1) that the siting of new buildings and structures shall be located
so that further shoreline protection measures are not needed in
the future; and
2) a setback determination may change if the adjacent property
owners submit applications and are granted permits for new or
remodeled residences established at proper shoreline setbacks.
Other Resource Ordinance Standards:
_Y_ Slope or Landslide hazards: Slopes greater than 15 percent
adjacent to or within 300 feet of a proposed project were observed
9/21/2011 Page 3 of 5 SP12011-00040
Site Inspection
9/21/2011 Case No.: SP12011-00040
in the middle area of the property. When proposing development,
the applicant shall have a qualified geologist or engineering
geologist visit the subject parcels and prepare a site analysis to
determine whether a geologic special report is needed during
development review.
_Y_ Slope or Landslide hazards: If the geologist confirms the
need for a special report when slopes are greater than 40 percent,
a Geotechnical Report would be needed to address slope
stability, site conditions, and the other requirements of the
enclosed landslide hazard chapter 17.01.100 section E. 5. as
required by the Mason County Resource Ordinance. The report
must include all Resource Ordinance requirements and a
submittal checklist noting where these requirements are found in
the study document.
_Y_ Slope or Landslide hazards: The prepared special report
shall be specific to proposed site development on the subject
parcel by addressing clearing, grading, driveway and building
location, retaining and stabilization walls, and stormwater control.
This study shall address the presence of the septic system on site
stability conditions. This special report would be submitted and
evaluated at the time of building permit submittal.
_N_ Wetland critical area: Planning staff confirmed that the
parcel does not contain certain wetlands, which are regulated
under Mason County's Wetlands chapter 17.01.070 of the Mason
County Resource Ordinance. The observed vegetation is
associated with the saltwater shoreline; so the applicant will not
need a wetlands special report during development review.
_N_ Stream setbacks: No seasonal or perennial drainage flows
through the subject property. The proposed development is
greater than 200 feet from the any stream management area
covered by the standards of this critical area.
An EAGLE MANAGEMENT review must be part of proposed
development. This is accomplished by contacting the WA. Fish &
Wildlife Biologist Jeff Skriletz [phone numbers (360) 427-2164]
and meeting him on site to discuss the status of the bald eagle
use in the area and constraints to proposed development of the
subject property. He will prepare a letter of his findings and
recommendations for development and send this letter to you.
You need to supply this information at the time of your
development applications.
9/21/2011 Page 4 of 5 SP12011-00040
Site Inspection
9/21/2011 Case No.: SP12011-00040
You would need to confirm with the Environmental Health
Department what their septic system standards are to make sure
about the adequacy of supplying a septic disposal for the
proposed development.
General process: Future development must include a site plan,
showing setbacks from property lines, shoreline, driveway, road,
and existing and proposed improvements; a topographical profile
or other topographical information may also be included on this
site plan, which the project geotechnical engineer or geologist
could prepare from this critical area information. Proper access is
available via a driveway easement on Winterwood Dr. along the
northwest property line. The site plan and the geologic study will
be needed for building permit application submittal and review.
Specific County Codes standards for future development may be
found at the County website address http://www.co.mason.wa.us.
If you have any questions please feel free to call. Thank you.
9/21/2011 Page 5 of 5 SP12011-00040
'Th 0s ItWL � CMASON COUNTY ( w
PLANNING DEPT. PRE-INSPECTION APPLICATION
PLEASE PRINT $255.00 Fee Required
l. Owner: LVPM A) Applicant: Nl✓1 ; S+ems )1�n
Site Address: wbd "4 I Ve— Applicant Address: k*Ww✓S
Owner Address: City:'A�'J 7 l h/ St ` X Zip �
City: fi tt Vi eanl St—WJA- Zip _ Phone:('�El 2- Zpk, 2 day
Phone:( day
Phone:) evening Planner: �4
�l' ml Email Address: SNIP U E104"o .Plan EqnALType of Use
T Water Body ("AL C =n��f
2. Parcel No. -_�- 9015-0
Parcel No.
Legal Description: (O rra- � I}—a—
3. Purpose of Pre-Inspection : de"`Ae_ 41 as
- s
A,A` b
4. Use of building: �'l o WS"
5. Do any of the following exist on or adjacent to property?: slope(✓S saltwater(V� lake( ) river( )
pond( ) wetland( seasonal runoff( ) other( ) stream ( ) seasonal creek( )
Directions to Site:t.G -
If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the original
application. Pre-inspection reports remain valid only until development changes occur in the vicinity which affect the lot
evaluated in this inspection,or the laws regulating development of the site change after the time of inspection.
Applicant Signature: Date: Z
/f you would like to be on site during inspection,please check here:
Return application to: Department of Community Development, Planning Division CL � �7�7
P.O. Box 186
Shelton, WA 98584
(360)427-9670
Please include a$255 .00 check or money order payable to Mason County Treasurer
When completed,this form becomes part of the parcel file.
FOR OFFICE USE ONLY: Accepted by: Date:
MORE ON BACK SIDE
Revised: 12/30/08
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes,wetlands, etc.)
existing improvements,as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
Departmental Review
(For Office Use Only)
Planning Depnt�ngs:
' Kim
r �`r� A
v�