Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2023-01525 SFR - BLD Application - 6/29/2023
BUILDING PERMIT APPLICATION � � PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Collin Russell NAME:Coval homes MAILING ADDRESS:310 Kissin Tree Lane MAILING ADDRESS: 1950 Pottery Ave CITY:Tayuha STATE:WA ZIP:98588 CITY:Port orchard STATE:WA ZIP:98366 PHONE#1:360-250-8388 PHONE:360-662-1520 CELL: PHONE#2: EMAIL :info@covalhomes.com EMAIL:collin.rae.russell@gmail.com L&I REG#COVALHL894QD EXP. PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER E] NAME Crystal Mattson EMAIL mattsonlandconsult@icloud.com MAILING ADDRESS 21227 88th Ave E CITY Graham STATE WA ZIp 98338 PHONE 253-228-7462 CELL 25623-228-7462 —_ PARCEL INFORMATION: r PARCEL NUMBER(12 Digit Number) 32334-24-00000 ZONING Rural Residential 5 (Abbreviated) SW SE NW LEGAL DESCRIPTION Abbreviated FIRE DISTRICT SITE ADDRESS Kissing Tree Lane ,j IZ CITY Tayuha DIRECTIONS TO SITE ADDRESS follow WA-300 W,NE Belfair Tahuya Rd and Dewatto Bay Road,turn left after Dairy Queen,turn left to stay on WA-300 W,continue onto NE North Shore Rd,turn right onto NE Belfair Tahuya Road,turn right onto Dewatto Bay Rd,turn right onto Kissin Tree Lane IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO Q SNOW LOAD: 25 psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM ❑ TYPE OF WORK: NEW 0 ADDITION ❑ ALTERATION ❑ REPAIR[I OTHER El USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc)Residence IS USE: PRIMARY E] SEASONAL ❑ NUMBER OF BEDROOMS 2 NUMBER OF BATHROOMS 1 HEATED STRUCTURE? YES(Whole Bldg) 0 YES(Part[s]of Bldg) ❑ NO ❑ DESCRIBE WORK To construct a 1000 square toot home SQUARE FOOTAGE: (proposed) I ST FLOOR 1,000 sq.ft. 2ND FLOOR 0 sq.ft. 3RD FLOOR 0 sq.ft. BASEMENT 0 sq.ft. DECK 0 sq.ft. COVERED DECK 108 sq. ft. STORAGE 0 sq.ft. OTHER 0 sq. ft. GARAGE 0 sq.ft. Attached❑ Detached❑ CARPORT 0 sq. ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC 0 SEWER❑ / NEW E] EXISTING ❑ PLUMBING IN STRUCTURE? YES E] NO ❑ If yes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES E] NO[] EXISTING SQ.FT. 3,675 EXISTING BEDROOMS D PROPOSED BEDROOMS 2 TOTAL BEDROOMS ,P- OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permittapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON Dm�sia�ed by: COUNTY CODE 14.08,42) X 1 6/29/2023 lgnature o OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED I DATE DENIED I DATE TAGS/NOTES/CONDITIONS DocuSign Envelope ID:EE6249DC-BF95-4C3E-A3B2-500920C7785A MASON COUNTY COMMUNITY SERVICES Permit No: ICI o�D�t3 D��a`7 PERMIT ASSISTANCE CENTER: •BUILDING •PLANNING •FIRE MARSHAL 615 W.Alder St-Shelton, WA 98584 www.co.mason.wa.us Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 • Phone Belfair..(360)275-4467• Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Collin Russell NAME:Coval Homes MAILING ADDRESS:310 Kissin Tree Lane MAILING ADDRESS:1950 Pottery Ave CITY:Tayuha STATE:WA ZIP:98588 CITY:Port orchard STATE:WA ZIP:98366 111 PHONE:360-250-8388 PHONE:360-662-152 CELL: 2°d PHONE: EMAIL :info@covalhomes.com EMAIL:collin.rae.russell@gmail.com LBLI REG#COVALHLB94QD EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):32334-24-00000 Zoning:Rural Residential 5 LEGAL DESCRIPTION(Abbreviated):sw SE NW SITE ADDRESS: Kissin Tree Lane CITY:Tayuha DIRECTIONS TO SITE ADDRESS: follow WA-300 W,NE Belfair Tahuya Rd and Dewatto Bay Road ,turn left after Dairy Queen,turn left,to stay on WA-300 W,continue onto NE North Shore Rd,turn right onto NE Belfair Tahuya Road,turn right onto Dewatto Bay Rd,turn right onto Kissin Tree Lane TYPE OF JOB: NEW F ADD=ALT=REPAIR=OTHERD USE OF BUILDING residence LOCATION OF FIXTURES/UNITS—1 IT FLOOR=2ND FLOOR=BASEMENT=GARAGE=OTHERO PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.oof Fixtures Fees Fuel Type:Electric[ LPG=Natural Gas=Ductless=✓ Toilets Type of Unit No.of Units Fees Bathroom Sink �1 Furnace Bath Tubs t/ Heat Pump Showers e/ Spot Vent Fan 2 Water Heater 1 Propane Tank Clothes Washer Gas Outlets Kitchen Sinks 1 Wood/Gas/Pellet Stove Dishwasher 1 /� Kitchen Exhaust Hood 1 Hose bibs 2/ Dryer Vent 1 Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/appl!cation becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL IN qJ%TATHE APPLICATION. X 6/29/2023 JA*ffff1-dfF0wner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN MATTSON LAND CONSULTING CONSTRUCTION 675'=/- 253-228-7462 ENTRANCE 25'SETBACK ----- R U S S E L L Well I --------------- 310 Kissin Tree Lane i Existing Tayuha, WA98588 Driveway 1i7', a0 I 32334-24-00000 ! a o Scale: 1"=100' Clearing; y d Limits 4"tightline May 5, 2023 6-2 to daylight Existing Septic O -y L� SF R Tank e J ✓ m l 22sq - ,��2 v ' ` 32-Q.---------------- 30 50'flowpath ' 5 Z v In to p - - - ! 1....._--- _._._-.-.-.-.---•---------54 r'-------------------•------ •----- -.F. -- Pro os d }._._.----- --- ------ Dnvew y h:,J , OSCAR with 2 pa ing ' ov space - - 8 '•-....... 4,N K/R/A 5 ------------- ;.. m ;50'flowpath ' m w i400' 380, 360' v EH APPROVED Rhonda Thompson 01/17/2024 360. 406' EH Setbacks 340' A.) Drainfield/Reserve requires 10'setback from footing/foundations B.)Septic tank(s)requires 5'setback from all footing/foundations C.)No foundation/Perimeter Drains within 30ft,downgradient of Drainfield/Reserve area D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area ----------------------+----------------------- ---------------------------------- 25'SETBACK 25' 50' 100, 675'_/- DocuSign Envelope ID:EE6249DC-BF95-4C3E-A3B2-500920C7785A Na,,,e Collin Russell _ Parcel# 32334-24-00000 BLD# 2-O; Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) MLC The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail:P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail:P 0 Box 1666,Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- de p"epty for review and inspection as may be required. l/- 6/29/2023 X FIM Owner/Agent/Contractor(circle one)Date:__________ Page 2 of 2 DocuSign Envelope ID:EE6249DC-BF95-4C3E-A3B2-500920C7785A Name Collin Russell Parcel# 32334-24-00000 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = 1274 40 X = 1274 Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = 100 X 15 = 1500 Length of drive begins at the right of way X = Parking Areas X = 25 X 35 = 875 Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 3649 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Pagel of 2 • MI t he COMMERCIAL-GRADE RESIDENTIAL ELECTRIC WATER HEATERS VOLTEX° HYBRID ELECTRIC HEAT PUMP WATER HEATER The Voltex Hybrid Electric heat pump water heater from A.0.Smith is the most cost effective energy-efficient option available for consumers who want to save money on their utility bills.Voltex can reduce water heating costs up to 73%and provide payback in 2-3 years.With annual savings of$306 or more,there is no better way to go green than Voltex. HOW DO THEY WORK? Absorb ambient heat from the surrounding air to heat water using a compressor and "Environmentally-Friendly" R134a refrigerant • Self-contained heat pump unit is integrated into the top of the tank • Multiple operating modes to maximize efficiency and performance QUALIFIES FOR MANY STATE AND LOCAL UTILITY REBATES- rsmitr, CHECK WWW.DSIREUSA.ORG INCREASED ENERGY EFFICIENCY DRY FIRE PROTECTION • Improved efficiency designed in,to ensure • Control system checks to ensure the available hot water at the lowest possible tank is full of water during start up to cost.Up to a 3.45 Uniform Energy Factor prevent dry firing the heating elements (UEF)Rating conserves energy and meets ELECTRONIC USER INTERFACE ENERGY STAR qualifications CHOICE OF OPERATING MODES • User-friendly electronic interface allows easy control of temperature setting, • Select from Efficiency,Hybrid,or Electric operating mode,and communicates modes to match heating requirements to diagnostics environmental conditions. • Easy to read temperature display(see • Hybrid mode automatically adjusts back)shows temperature in°F or°C between compressor and element, . Advanced diagnostics convey error depending upon heat requirements. messages for service purposes.The last • Vacation mode reduces operating costs four error messages are saved in the and provides freeze protection during control system memory. extended absence OTHER FEATURES BACKUP ELECTRIC ELEMENTS • Ideal for basements or garage • Long-lasting backup heating elements installations;the compressor transfers help heat water according to heat to the water while dehumidifying `— --.•r•+� environmental conditions,demand,and and cooling the ambient air the chosen operating mode . Washable air filter is easily removed for COREGARD"ANODE ROD routine cleaning r� S R • Our anode rods have a stainless steel OPTIONAL AIR DUCT ADAPTER KIT ® Q @ core that extends the life of the anode . Permits installation in confined spaces MEMO LISTED rod allowing superior tank protection far longer than standard anode rods TEN YEAR LIMITED WARRANTY it ILJ12F • 66 and 80 gallon models have dual • For complete information,consult r anodes for added protection. written warranty or go to hotwater.com ©April 2019 A.0.Smith Corporation.All Rights Reserved Page t rf 7 www.hotwater.com 1 800-527-1953 Toll-Free USA I A.0.Smith Corporation 1 500 Tennessee Waltz Parkway I Ashland City,TN 37015 AOSXE50007 • m COMMERCIAL-GRADE i RESIDENTIAL ELECTRIC WATER HEATERS Model Nominal Rated First Hour Dimensions in Inches Approx. Number Capacity Storage UEF Rating Shipping Warranty Term Volume (Gallons) A B C D E Weight(Ibs) HPTU-50N 50 46 3.45 66 63 22 40-5/8 3-3/4 40-1/2 196 10 HPTU-66N 66 67 3 45 79 61 27 38 4 38 289 10 HPTU-80N 80 82 3.45 86 69 27 46 4 46 307 10 Requires 30 amp breaker. Top T&P option not available. f EFFICIENCY HYBRID MODE ! ELECTRIC EN7ER/ i VACATION ELECTRONIC USER INTERFACE • User friendly,easy to read display. A • LEDs clearly indicate the current operating mode. • Easily select operating mode: B • Efficiency • Hybrid E C • Electric • Vacation • Display communicates current status,mode and set point,and displays error messages when applicable. EFFICIENCY MODE • Utilizes the heat pump for all water heating. o • Automatically reverts to heating element if ambient air or water temperatures are outside optimal operating range for heat pump. HYBRID MODE OTHER FEATURES: • Utilizes the heat pump or heating element,depending on demand. • Sacrificial anode to protect against tank corrosion. ELECTRIC MODE • Environmentally-friendly non-CFC foam insulation. • Standard electric water heater operation. • Durable,enhanced-flow brass drain valve. VACATION MODE • CSA certified and ASME rated temperature&pressure relief valve. • One touch operation maintains tank temperature of 60°F OPERATING REQUIREMENTS: (15.6°C)during vacation or extended absence to reduce • Requires provision for condensate draining;if a suitable drain is operating costs and provide freeze protection. not available,a condensate pump is required. • Programmable up to 99 days. • 208/240 VAC 60Hz single phase 30 amp power supply. For Technical Information,call 800-527-1953.A.0.Smith Corporation reserves the right to make product changes or improvements without prior notice. ©April 2019 A.0.Smith Corporation.All Rights Reserved Page 2 of 2 www.hotwater.com 1800-527-1953 Toll-Free USA AOSXE50007 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U dated:1 18 2021 Maximum CTA-2045 Product Tier Product Brand Model volume Recommended Cool Climate Energy Factor Compliant Qualifi (gallons) Household Size Efficiency[CCE)t NO Communication D. - Direct Energy ECEPH40 T2 RH375-15 40 2 3.1 - x 10/23/2020 Direct Energy ECEPH50 T2 RH375-15 50 2-3 3.2 - X 10/23/2020 _ - � Direct Energy ECEPH65 T2 RH375-15 65 23 t 3.2 - x 10/23/2020 Direct Energy ECEPH80 T2 RH375-15 80 4 3.2 - x 10/23/2020 Direct Energy .....�_ECEPH40 T2 RH375-30.. 40 2 3.1 ._. - x 10/23/2020 Direct Energy ECEPH50 T2 RH375 30 50 2-3 3.2 x 10/23/2020 Direct Energy ECEPH65 T2 RH375 30 65 2-3 3.2 x 10/23/2020 Direct Energy ECEPH80 T2 RH375-30 80 4 3.2 - x 10/23/2020 Direct Energy ECEPH40 T2 RH375-SO 40 2 3.1 - x ; 10/23/2020 Direct Energy ECEPH50 T2 RH375-SO So 2 3 3.2 x 10/23/2020 Direct Energy I ECEPH65 T2 RH375-SO 65 2 3 3.2 x 10/23/2020 Direct Energy ECEPH80 T2 RH375-50 80 4 3.2 ' - x 10/23/2020 Rheem HPLD40-1RH 40 2 3.1 - x 10/23/2020 Rheem HPLD50-1RH 50 2-3 3.2 - x 10/23/2020 Rheem HPLD65-1RH 65 2-3 3.2 - x 10/23/2020 Rheem HPLD80-1RH 80 4 3.2 - x 10/23/2020 Rheem PROPH40 T2 RH375-15 40 2 3.1 -- x 4/23/2020 Rheem PROPH50 T2 RH375-15 50 2-3 3.2 - x 4/23/2020 Rheem PROPH65 T2 RH375-15 65 ! 2-3 3.2 - x 4/23/2020 Rheem PROPH80 T2 RH37515 80 m 4 3.2Y - x 4/23/2020 Rheem PROPH40 T2 RH375-30 40 2 3.1 ---EPEE -- x 4/23/2020 Rheem PROPH50 T2 RH375-30 50 2-3 3.2 - x 4/23/2020 Rheem PROPH65 T2 RH375-30 , 65 2-3 3.2 - z 4/23/2020 Rheem PROPH8O T2 RH375-30 80 4 3.2 - x 4/23/2020 Rheem PROPH40 T2 RH375 SO 40 2 3.1 -- x 4/23/2020 Rheem PROPH50T2RH375-SO 50 2-3 3.2 -- x 4/23/2020 Rheem PROPH65 T2 RH375-SO 65 t 2-3 3.2 -- x 4/23/2020 Rheem PROPH80 T2 RH375-SO 80 4 3.2 -- x 4/23/2020 Rheem XE4OT1OH22UO 40 2 3.1 -- x 4/23/2020 Rheem XESOTlOH22UO 50 2-3 3.2 - x 4/23/2020 Rheem XE65T1OH22UO 65 2-3 3.2 --}---�- x 4/23/2020 Rheem XE80TIOH22UO 80 4 3.2 f _ x 4/23/2020 Rheem XE4OT1OH45UO 40 2 3.1 x 4/23/2020 Rheem XE50T1OH45UO 50 2-3 3.2 - x 4/23/2020 Rheem XE65T1OH45UO 65 2-3 3.2 x 4/23/2020 _. -.._ c..... ...._. ..._. Rheem XEBOTlOH45UO 8o 4 3.2 -- x 4/23/2020 Rheem XE40TIOHS45UO 40 2 3.1 -- x 4/23/2020 Rheem XE50TlOHS45UO SO 2-3 3.2 -- x 4/23/2020 Rheem XE65T1OHS45UO 65 2-3 3.2 - x 4/23/2020 Rheem XE80TIOHS45UO 80 4 3.2 f x 4/23/2020 Rheem Canada CPROPH40 T2 RH375-11 40 2 3'1 - x 10/23/2020 Rheem Canada CPROPH50 T2 RH375-15 50 2-3 3.2 t - x 10/23/2020 Rheem Canada CPROPH65 T2 RH375-15 65 2-3 3.2 - x 10/23/2020 Rheem Canada CPROPH80 T2 RH375-15 - 80 4 3.2 - x 10/23/2020 Rheem Canada CPROPH40 T2 RH375-30 40 2 3.1 - x 10/23/2020 Rheem Canada CPROPH50 T2 RH375-30 50 2-3 3.2 - x 10/23/2020 Rheem Canada CPROPH65 T2 RH375-30 65 2-3 3.2 - x 10/23/2020 Rheem Canada CPROPH80 T2 RH375-30 80 4 3.2 x 10/23/2020 Rheem Canada CPROPH40 T2 RH375-50 40 2 3.1 - x 10/23/2020 Rheem Canada CPROPH50 T2 RH375-SO 50 2-3 3.2 -� x 10/23/2020 Rheem Canada CPROPH65 T2 RH375-SO 65 2-3 3.2 - x 10/23/2020 Rheem Canada CPROPH80 T2 RH375-SO 80 4 3.2 - x 10/23/2020 Rheem Canada CXE40T1OH22UO 40 2 3.1 - x 10/23/2020 Rheem Canada CXESOTlOH22UO 50 2-3 3.2 - x 10/23/2020 Rheem Canada CXE65T1OH22UO 65 2-3 3.2 - x 10/23/2020 Rheem Canada CXE8OT1OH22UO 80 4 3.2 - x 10/23/2020 Rheem Canada CXE40T1OH4SUO 40 2 3.1 x 10/23/2020 Rheem Canada CXE5OT1OH45UO 50 2-3 3.2 -- x 10/23/2020 Rheem Canada CXE65T1OH45UO 65 2-3 3.2 -- x 10/23/2020 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U dated:1 18 2021 Port*Maximum CTA-204S Product Tier Product Brand Model Volume Recommended Cool Climate Energy Factor Compliant Qualified (gallons) Household Size Efficiency(CCE)t NO Communication Date Rheem Canada CXE80T1OH4SUO 80 4 3.2 -- x 10/23/2020 Rheem Canada CXE40TlOHS45UO 40 2 3.1 -- x 10/23/2020 Rheem Canada CXE50T1OHS4SUO 50 2-3 3.2 -- x 10/23/2020 Rheem Canada CXE65T10HS45UO 65 `�_.. 2-3 3.2 -- x 10/23/2020 Rheem Canada CXE8OT1OHS45UO 80 4 3.2 -- x 10/23/2020 Richmond SOE40-HP515 40 2 3.1 -- x 4/23/2020 Richmond lOE50-HP515 50 2-3 3.2 -- x 4/23/2020 Richmond 10E65-HP515 65 2-3 3.2 -- x 4/23/2020 Richmond 10E80-HP515 80 4 3.2 -- x 4/23/2020 Richmond 10E40-HP530 40 2 3.1 -- x 4/23/2020 Richmond 10E50-HP530 50 2-3 3.2 -- x 4/23/2020 Richmond lOE65-HP530 65 2-3 3.2 -- x 4/23/2020 Richmond 1OESO-HP530 80 4 3.2 -- x 4/23/2020 Richmond 1OE40-HP5S30 40 2 3.1 -- x 4/23/2020 Richmond 1OE50-HP5S30 50 2-3 3.2 -- x 4/23/2020 Richmond 10E65-HPSS30 65 2-3 3.2 -- x 4/23/2020 Richmond 10E80-HP5S30 '.. 80 4 3.2 -- x 4/23/2020 Ruud HPLD40-1RU 40 2 3.1 -- x 10/23/2020 Ruud HPLD50-1RU 50 2-3 3.2 -- x 10/23/2020 Ruud HPLD65-1RU _ 65 2-3 3.2 -- x 10/23/2020 Ruud HPLD80-1RU 80 4 3.2 -- x 10/23/2020 Ruud PROUH40 T2 RU37515 40 2 3.1 -- x 4/23/2020 Ruud PROUH50 T2 RU375-15 so 2-3 3.2 -- x 4/23/2020 Ruud PROUH65 T2 RU375-15 65 2-3 3.2 - x 4/23/2020 Ruud PROUH80 T2 RU375-15 80 4 3.2 - x 4/23/2020 Ruud PROUH40 T2 RU375-30 40__ 2 3.1 - x 4/23/2020 . ._.. _. Ruud PROUH50 T2 RU375-30 50 2-3 3.2 - x 4/23/2020 Ruud PROUH65 T2 RU375-30 65 2-3 3.2 x 4/23/2020 Ruud PROUH80 T2 RU375-30 80 4 3.2 - x 4/23/2020 Ruud PROUH40 T2 RU375-SO _ 40 2 3.1 - x 4/23/2020 Ruud PROUH50 T2 RU375-SO 50 2-3 3.2 - x 4/23/2020 Ruud PROUH65 T2 RU375 SO 65 2-3 3.2 - x 4/23/2020 Ruud PROUH80 T2 RU375-SO .,.80 4 3.2 - x 4/23/2020 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U9,dated,1Maximum CTA-2045 18 2021 QualifiedProduct Tier Product Brand Model volume Recommended Cool Climate Energy Factor Compliant (gallons) Household Size Efficiency(CCE)t NCt Communication Date Tier 3 mit H 5 0 50 2- 6 2 A.O.Smith HPTU SON**' 50 2-3 2.9 -- -- 6/24/2016 dLSU 2 6dL IL JL AL JL JL JU X - IL A.O.Smith HPTU 66N"* 66 3 3.1 - - 6/24/2016 A.0.Smith HPTU 80 120 80 4+ 2.9 6/24/2016 A.O.Smith HPTU SON"` 80 4+ 2.9 - - 6/24/2016 A.O.Smith HP10-SOH45DV 50 2-3 2.9 -- -- 3/14/2017 A.O.Smith HP10-50H45DV"• 5o 2-3 2.9 -- - 3/14/2017 A.0.Smith HP10-BOH45DV 80 4+ 2.9 -- -- 3/14/2017 A.O.Smith HP30-8OH45DV"• 80 4+ 2.9 -- -- 3/14/2017 A.0.Smith HP105OH45DVCTA 130 50 2-3 2.9 -- x 1/18/2021 A.O.Smith HP108OH45DVCTA 130 80 4+ 2.9 -- x 1/18/2021 A.O.Smith HP105OH45DVDR 130 50 2-3 2.9 -- x 10/14/2020 A.O.Smith HP108OH45DVDR 130 80 4+ 2.9 -- x 10/14/2020 A.0.Smith HPTU-SOCTA 130 50 2-3 2.9 -- x 1/18/2021 A.O.Smith HPTU-66CTA 130 66 3 3.1 -- x 1/18/2021 A.0.Smith HPTU-80CTA 130 80 4+ 2.9 -- x 1/18/2021 A.0.Smith HPTU-50DR 130 50 2-3 2.9 -- x 10/14/2020 A.O.Smith HPTU-66DR 130 66 3 3.1 -- x 10/14/2020 A.O.Smith HPTU-80DR 130 80 4+ 2.9 - x 10/14/2020 American HPHE10250HO45DV 120 50 2-3 2.9 - - 6/24/2016 American HPHE10250HO45DVN••• 50 2-3 2.9 - - 6/24/2016 American HPHE10266HO45DV 120 66 3 3.1 - - 6/24/2016 American HPHE10266HO45DVN'•' 66 3 3.1 - - 6/24/2016 American HPHE10280HO45DV 120 80 4+ 2.9 - - 6/24/2016 American HPHE10280HO45DVN- 80 4+ 2.9 - - 6/24/2016 American HPHE10250HO45DVCTA 130 50 2-3 2.9 - x 1/18/2021 American HPHE10266HO45DVCTA 130 66 3 3.1 - x 1/18/2021 American HPHE10280HO45DVCTA 130 80 4+ 2.9 - x 1/18/2021 American HPHE10250HO45DVDR 130 50 2-3 2.9 _ -_^m x 10/14/2020 American HPHE10266HO45DVDR 130 66 3 3.1 - x 10/14/2020 American HPHE10280HO45DVDR 130 80 4+ 2.9 - x 10/14/2020 Bradford White RE2H5OR10*-***** 50 2-3 2.8 - - 2/9/2017 Bradford White RE2HSOR10*-***'* 80 4+ 3.1 - - 2/9/2017 Bradford White RE2H50S10--**•'• 50 2-3 2.8 - - 2/8/2018 Bradford White RE2H65T10-***** 65 3 3.0 - - 3/26/2020 Bradford White RE2H80T10-*"•' 80 4+ 3.1 - - 2/8/2018 Direct Energy ECE H40 T2 RH310BM 40 2 2.9 10/23/2020 Direct Energy ECE H50 T2 RH3108M 50 2-3 2.9 - - 10/23/2020 Direct Energy ECE H65 T2 RH3108M 65 2-3 2.9 - 10/23/2020 Direct Energy ECE HBO T2 RH310BM 80 4 2.9 -- - 10/23/2020 GE BEH50DCEJSB 50 2-3 -- 2.8 - 9/8/2016 GE BEH8ODCEJSB 80 4+.�.. -- 3.1 - 9/8/2016 GE GEHSODEEJSC 50 2-3 •- 2.8 - 9/8/2016 GE GEH50DFEJSR t 50 2 3 - 1 2.8 - 9/8/2016 __....._-_.-_ It - ...._ GE GEHSODHEKSC 50 2-3 - 2.8 - 9/8/2016 GE GEH80DEEJSC 80 4+ - 3.1 - 9/8/2016 GE GEH8ODFEJSR 80 4+ - 2.9 - 9/8/2016 GE GEH80DHEKSC - 80 4+ F �- 3.1 - 9/8/2016 Kenmore 153.5925 50 2-3 2.9 ------ - 6/24/2016 Kenmore 153.5926 _ 66 3 3.1 - - 6/24/2016 Kenmore 153.5928 80 4+ 2.9 - - 6/24/2016 Lochinvar HPA051KD 120 50 2-3 2.9 - - 6/24/2016 Lochinvar HPA052KD'•• 50 2-3 2.9 - - 6/24/2016 Lochinvar HPA067KD 120 66 3 3.1 - - 6/24/2016 Lochinvar HPA068KO"' 66 3 3.1 - - 6/24/2016 Lochinvar HPA081KO 120 80 4+ 2.9 - - 6/24/2016 Lochinvar HPA082KD'•' 80 4+ 2.9 - 6/24/2016 Reliance 10 50 DHPHT 120 50 2-3 2.9 - - 6/24/2016 Reliance 1050 DHPHTNE*** 50 2-3 2.9 - - 6/24/2016 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U dated:1 18 2021 maximum CTA-2045 Qualified Product Tier Product Brand Model Volume Cool Climate Energy Factor Compliant (gallons) Recommended Efficiency(CCE)t NCt Communication Date Port*Household Size Reliance 10 66 DHPHT 120 66 3 3.1 -- - 6/24/2016 Reliance 10 66 DHPHTNE- 66 3 3.1 -- -- 6/24/2016 Reliance 1080 DHPHT 120 80 4+ 2.9 -- -- 6/24/2016 Reliance 1080 DHPHTNE*** 80 4+ 2.9 -- -- 6/24/2016 Reliance 10-50-DHPHTCTA 130 50 2-3 2.9 -- x 1/18/2021 Reliance, 10-66-DHPHTCTA 130 66 3 3.1 -- x 1/18/2021 Reliance 10-80-DHPHTCTA 130 80 4+ 2.9 -- x 1/18/2021 Reliance 10-50-DHPHTDR 130 50 2-3 2.9 -- x 10/14/2020 Reliance 10-66-DHPHTDR 130 66 3 3.1 - x 10/14/2020 Reliance 10-80-DHPHTDR 130 80 4+ 2.9 - x 10/14/2020 Rheem PRO H40 T2 RH3108M 40 2 2.9 - -- 4/23/2020 Rheem PRO H50 T2 RH310BM 50 2-3 2.9 - - 4/23/2020 Rheem PRO H65 T2 RH310BM 65 2-3 2.9 - - 4/23/2020 Rheem PRO H80 T2 RH310BM 80 4 2.9 - - 4/23/2020 Rheem PRO H40 T2 RH310UM 40 2 2.9 - x 11/23/2020 Rheem PRO H50 T2 RH310UM SO 2-3 2.9 -- x 11/23/2020 Rheem PRO H65 T2 RH310UM a 65 2-3 2.9 - x 11/23/2020 Rheem PRO H80 T2 RH330UM 80 4 2.9 - x 11/23/2020 Rheem PRO H50 T2 RH350BM 50 2-3 3.2 - -- 8/20/2018 Rheem PRO H65 T2 RH350BM 65 2-3 3.4 - -- 8/20/2018 Rheem PRO H80 T2 RH350BM 80 4 3.4 - - 8/20/2018 Rheem PROPH50 T2 RH350 DC 50 2-3 3.2 - - 12/6/2017 Rheem PROPH65 T2 RH350 DC 65 2-3 3.4 - - 12/6/2017 Rheem PROPH80 T2 RH350 DC 80 4 3.4 - 12/6/2017 Rheem HPLD50 50 2-3 3.2 - - 12/6/2017 Rheem HPLD65 65 2-3 3.4 - - 12/6/2017 Rheem HPLD80 80 4 3.4 - - 12/6/2017 Rheem XE50T10HD22U0 50 2-3 3.2 - - 12/6/2017 Rheem XES0T10HD50U1 50 2-3 3.2 - - 12/6/2017 Rheem XE65T10HD22U0 65 2-3 3.2 - - 12/6/2017 Rheem PROPH80 T2 RH350 D 80 4 3.4 - 10/24/2016 Rheem XESOT10HD5000 50 2-3 3.2 - 10/24/2016 Rheem XE65T10HD5000 65 2-3 3.4 -- 10/24/2016 Rheem XE80T10HD5000 80 ! 4 3.4 - 10/24/2016 Rheem Canada CPRO H40 T2 RH310BM 40 2 2.9 - 10/23/2020 Rheem Canada CPRO H50 T2 RH310BM 50 2-3 2.9 - - 10/23/2020 Rheem Canada CPRO H65 T2 RH3: 65. .. 2-3 2.9 - - 10/23/2020 Rheem Canada CPRO H80 T2 RH310BM 80 4 2.9 - - 110/23/2020 Richmond 10E65-HP4D15 65 2-3 3.2 �- - 12/6/2017 Richmond 10E80-HP4D15 80 4 3.2 - - 12/6/2017 Richmond 10E50-HP4D 50 2-3 3.2 - - 10/24/2016 Richmond 10E65-HP4D 65 2-3 3.4 - - 10/24/2016 Richmond 10E80-HP4D 80 4 3.4 - - 10/24/2016 Ruud PRO H40 T2 RU310BM 40 2 2.9 - - 4/23/2020 Ruud PRO H50 T2 RU310BM 50 2-3 2.9 - - 4/23/2020 Ruud PRO H65 T2 RU3108M 65 2-3 2.9 - - 4/23/2020 Ruud PRO H80 T2 RU310BM 80 4+ 2.9 - - 4/23/2020 Ruud PRO H40 T2 RU310UM 40 2 2.9 - x 11/23/2020 Ruud PRO H50 T2 RU310UM 50 2-3 2.9 - x 11/23/2020 Ruud PRO H65 T2 RU310UM 65 2-3 2.9 - x 11/23/2020 Ruud PRO H80 T2 RU310UM 80 4 2.9 - x 11/23/2020 Ruud PRO H50 T2 RU350BM 50 2-3 3.2 - - 8/20/2018 Ruud PRO H65 T2 RU3508M 65 2-3 3.4 - - 3 8/20/2018 Ruud PRO H80 T2 RU350BM 80 4 3.4 - - 8/20/2018 Ruud PROUH50 T2 RU350 DCB 50 2-3 3.2 - - 12/6/2017 Ruud PROUH65 T2 RU350 D15 65 2-3 3.2 - - 12/6/2017 Ruud PROUH65 T2 RU350 DCB 65 2-3 3.4 - - 12/6/2017 Ruud PROUH80 T2 RU350 D15 80 4 3.2 - - 12/6/2017 Ruud PROUH80 T2 RU350 DCB 80 4 3.4 - - 12/6/2017 Ruud PROUH50 T2 RU350 D 50 2-3 3.2 - 10/24/2016 Ruud PROUH65 T2 RU350 D 65 2-3 3.4 - 1_10/24/2016 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U dated:1 18 2021 Product Tier Product Brand Model Volume Maximum '45 Compliant Qualified Recommended Cool Climate Energy Factor Igallons) Household Size Efficiency(CCE)t NO Communication Date Ruud PROUH80 T2 RU350 D 80 4 3.4 -- -- 10/24/2016 Sanden G53-45HPA-US,SAN-435SAQA 43 3 2.9 - -- 3/10/2017 Sanden GS3-45HPA-US,GAUS-160QTA 43 3 2.9 - -- 3/10/2017 Sanden GS3-45HPA-US,SAN-83SSAQA 83 4+ 3.3 - - 3/10/2017 Sanden GS3-45HPA-US,GAUS-315EQTD 83 4+ 3.3 - - 3/10/2017 Sanden GUS-45HPA,SAN-83SSAQA 83 4+ - 3.2 - 3/10/2017 Sanden GUS-45HPA,GAUS-315EQTD 83 4+ - 3.2 - 3/10/2017 Sanden GS3-45HPA,SAN-119GLBK 119 4+ 3.0 - 7/25/2018 State HPX 50 DHPT 120 So 2-3 2.9 - - - 6/24/2016 State HPX 50 DHPTNE•'• 50 2-3 2.9 - - 6/24/2016 State HPX 66 DHPT 120 66 3 3.1 - - 6/24/2016 State HPX 66 DHPTNE""' 66 3 3.1 - - 6/24/2016 State HPX 80 DHPT 120 80 4+ 2.9 - - 6/24/2016 State HPX 80 DHPTNE""• 80 4+ 2.9 -- - 6/24/2016 State HPX-50-DHPTCTA 130 50 2-3 2.9 -- x 1/18/2021 State HPX-66-DHPTCTA 130 66 3 3.1 -- x 1/18/2021 State HPX-80-DHPTCTA 130 80 4+ 2.9 - x 1/18/2021 State HPX-50-DHPTDR 130 50 2-3 2.9 - - x 10/14/2020 State HPX-66-DHPTDR 130 66 3 3.1 -- x 10/14/2020 State HPX-80-DHPTDR 130 80 4+ 2.9 x 10/14/2020 US Craftmaster HPHE2K50HDO45VUN`"' S0 2-3 2.9 -- - 6/24/2016 US Craftmaster HPHE2K66HDO45VUN'•• 66 3 3.1 - _ - 6/24/2016 US Craftmaster HPHE2K8OHDO45VUN'•• 80 4+ 2.9 - - 6/24/2016 Whirlpool HPHE2K50HDO45V 120 - 50 2-3 2.9 - - 6/24/2016 Whirlpool HPHE2KSOHDO45VN 120 SO 2-3 2.9 - - 6/24/2016 Whirinn Tier 2 There are no Tiet 2 products avai I a I a as oft h a d a tei of this posting. _ Tier IL A.0.Smith FPTU 50'•* 50 2-3 - 2.4 - 8/9/2016 A.O.Smith FPTU 66•'" 66 3 - 2.6 - 8/9/2016 A.O.Smith FPTU 80"" 80 4+ 2.7 - 8/9/2016 A.O.Smith HHPT 80102 80 4+ - 1.8 - 11/10/2011 American HPE6280HO45DV 102 4. 80 4+ - 1.8 - 8/9/2016 American HPHE6250HO45DV"' 50 2-3 - 2.4 - 8/9/2016 American HPHE62H45DV"' 66 3 - 2. 8/9/2016 American HPHE628080HO45DV•** 80 4+ - 2.77 - 8/9/2016 Bradford White RE2H5OS6-****• 50 2-3 2.8 - - 4/23/2020 Bradford White RE2H65T6-••'•" - 65 3 3.0 I - 4/23/2020 Bradford White RE2H8OT6-•***" 80 4+ 3.1 4/23/2020 Reliance 650 DHPHT*•' 50 2-3 - I 2.4 -- 8/9/2016 Reliance 666DHPHT'*' 66 3 - 2.6 - 8/9/2016 Reliance 6 80 DHPHT•"• 80 4+. - 2.7 - 8/9/2016 Reliance 6 80 DHPT 102 80 4+_ _ _ 1.8 - 11/10/2011 Rheem PROPH50 T2 RH245BM 50 1-2 - 1.9 5/15/2016 Rheem PROPH80 T2 RH245BM 80 3 -- 2.3 - 5/15/2016 Ruud PROPH50 T2 RU245BM 50 1-2 ' - 1.9 - 5/15/2016 Ruud PROPH80 T2 RU245BM 8o 3 - 2.3 5/15/2016 State EP6 80 DHPT 102 80 4+ 1.8 - 11/10/2011 State HP6 50 DHPT"" 50 2-3 - 2.4 - 8/9/2016 State HP6 66 DHPT`•• 66 3 - 2.6 - 8/9/2016 State HP6 80 DHPT'•• 80 4+ - 2.7 - 8/9/2016 US Craftmaster HPE2F8OHDO45VU 102 80 4+ - 1.8 - 11/10/2011 US Craftmaster HPHE2F5OHDO45VU'"" 50 2-3 2.4 - 8/9/2016 US Craftmaster HPHE2F66HDO45VU•'" 66 3 - 2.6 - 8/9/2016 US Craftmaster HPHE2F80HD04SVU••• 8o 4+ -- 2.7 -- 8/9/2016 Advanced Water Heater Specification Qualified Products List for Heat Pump Water Heaters Last U dated:1 18 2021 Maximum t45 Compliant Qualified Product Tier Product Brand Model Volume Recommended Cool Climate Energy Factor (gallons) Household Size Efficiency(CCE)t NCt Communication Date For models listed with an asterisk—any number is allowed to substitute for the'.For example,"'could be 120 or 130. t Version 7 of the Advanced Water Heating Specification renamed the Uniform Energy Factor NC(UEFnc)to Cool Climate Efficiency(CCE)and the underlying tests and cakulations remained identical.Prior to May 2016, •Version 7of the Advanced Water Heating Specification requires all products at Tler3 and higherlevels to hove a CTA-1045 compliant communications port.Prior to version 7,the CTA-2045 port was optional at Tier3 For specifications,procedures,and criteria,see: htta://neeo.ora/advancedwaterheatersaec VNorthwest Energy Efficiency Alliance neea SUBMITTAL D. ttt : WALL-MOUNTED Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: Wireless Remote Controller MSZ-GL12NA ❑MUZ-GL12NA-U1 ❑MUZ-GLI2NA-U2 GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Maximum Capacity BTU/H 13,600 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 1,500 Cooling' Maximum Power Input W 1,300 Rated Power Input W 920 Moisture Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor % 95/95 Maximum Capacity BTU/H 18,100 Rated Capacity BTU/H 14,400 Heating at 47°FZ Minimum Capacity BTU/H 2,000 Maximum Power Input W 1,620 Rated Power Input W 1,100 Power Factor % 96/96 Maximum Capacity BTU/H 12,000 Heating at 17°F3 Rated Capacity BTU/H 9,200 Maximum Power Input W 1,240 Rated Power Input W 870 Heating at 5°F4 Maximum Capacity BTU/H 9,790 Maximum Power Input W 1,020 Heating at-4°F5 Maximum Capacity BTU/H 7,920 SEER P3.1 EER1 13.0 HSPF(IV) 12.5 Efficiency COP at 47°F2 3.84 COP at 17°F in Maximum Capacity3 2.84 COP at 5°F in Maximum Capacity4 2.81 ENERGY STAR®certified units(ENERGY STAR products are third-party certified YES by an EPA-recognized Certification Body.) Voltage,Phase,Frequency 208/230V,1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) kA 5 Recommended Fuse/Breaker Size(Outdoor) A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 MOCP A 15 Indoor Unit Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 399-321-237-170-145 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. A & Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 45-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight Lbs.(kg) 26(11.5) Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)' -F 90 DB,73 WB/67 DB,57 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 80 DB/70 DB MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229/1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Cooling' dB(A) 49 Sound Pressure Level,Heating2 dB(A) 51 Compressor Type DC INVERTER-driven Compressor Model SNBO92FQAMT Outdoor Unit Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type H Charge oz. FV50S H 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional W.In.(mm) 31-1/3(800) Unit Dimensions D:In.(mm) 11-1/5(285) H:In.(mm) 21-5/9(550) W:In.(mm) 37(940) Package Dimensions D:In.(mm) 14-15/16(380) H:In.(mm) 24-13/16(630) Unit Weight Lbs.(kg) 81 (37) Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. A & Package Weight Lbs.(kg) 89(40) Cooling Air Temp(Maximum/Minimum)* °F 115/14 Outdoor Unit Operating Cooling Thermal Lock-out/Re-start Temperatures** °F -1/3 Temperature Range Heating Air Temp(Maximum/Minimum) °F 75/-4 Heating Thermal Lock-out/Re-start Temperatures— °F -9/-4 Type R410A Refrigerant Charge Lbs,oz 2,9 Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Piping Maximum Piping Length Ft.(m) 65(20) Maximum Height Difference Ft.(m) 40(12) Maximum Number of Bends 10 Notes AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor H Outdoor) °F 70 DB,60 WB 1147 DB,43 WB determined at a fixed compressor speed) 3Heating at 17°F(Indoor H Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB SHeabng at-4°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo touchTm RedLINKTm Wireless Controller ❑MHK2 Deluxe MA Remote Controller' ❑PAR-40MAAU Simple MA Controller' ❑PAC-YT53CRAU-J Touch MA Controller' ❑PAR-CT01 MAU-SB Wired Remote Sensor a M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interface2 ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01 UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKPI CB Blue Diamond Sensor Extension Cable—15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. ❑C13-192 Blue Diamond Mu16Tank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump—230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711 -110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W I Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: Air Outlet Guide ❑MAC-881 SG Drain Socket ❑MAC-860DS Optional Defrost Heater ❑MAC-640BH-U Hail Guard ❑HG-B4 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" ❑ULTRILITEI Outdoor Unit Stand—12"High ❑QSMS1201 M Outdoor Unit Stand—18"High ❑QSMS1801M Outdoor Unit Stand—24"High ❑QSMS2401M Heavy Duty Wall Mounting Bracket—Coated Steel ❑OSWB2000M-1 Heavy Duty Wall Mounting Bracket—316 Series Stainless Steel ❑QSWBSS 15'x 1/4"x 15'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-15 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-30 50'x 1/4"x 50'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-50 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-65 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: Unit: inch 7/16xl Oblong hole 7/16x13116 Walla hole Installation plate 3 I/8 8 7/8 8-7/8 -I/8 ,p 31-7/I6 30-15/16 1/4 o ao _ m m 6 1/8 6-1/8 co 2 3/ �_-5/16 13-9/16 2 I/8 9 I/B 3/16 Indoor unit A rj in all hole /3 V Installation plate 1 I IS/16 24 3/8�5 I/8� �. Z- 3/4 — 4 3/I6� ' 2 5/16 3/4 — \Dro,n hose 4 3/ I Alf OUt M Insulation ol-3/80.D .a Liquid line o1/4 19-11/16(Flared connection o1/4) a Gas line o3/8 16-15/16 2-3/16 1-15/1 6 (Flared connection:o3/8(06109112 KBTU/H),e1/2(15 KBTUIH) 1-3/16 Drain hose Insulation of-1/8 0.13 Connected part o5/8 0,13 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MUZ-GL12NA Unit: inch REQUIRED SPACE '1 4 in. or more when front and sides of the unit are clear U pie 4 01 /hpre 15-3/4 j v Ak in �+ Drain hole 01-2V32(09/12/15 Bto/n) MA +2 { v ce v Air In m � pr `r o, a�� Mpre .. C N m m� '2 When any 2 sides of left, right 1-9/16 and rear of the unit are clear Air 0ut 2-holes 3/Bx13/16 Service panel 7/B 11/16 H.11n l Liquid refrigerant pipe joint aD Refrigerant pipe(flared)o 1/4 � N N rn M Gas refrigerant pipe joint N N N Refrigerant pipe(flared)to 3/8(09112 KBTU/H) N Ln Rl m N m 1/2(15 KBTU/H) i m m 1-29/3 5-11/32 -15/1 19-11/16 6-23/32 Bolt pitch for installation 31-1/2 2-3/4 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com Etb uS FORM#MSZ-GL12NA/MUZ-GL12NA-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.