HomeMy WebLinkAboutCOM2019-00055 COM BUILDING - COM Application - 4/25/2019 �goN c0 MASON COUNTY COMMUNITY SERVICES s'a ��
V PERMIT ASSISTANCE CENTER: Permit No: �
_" "
BUILDING.PLANNING •PUBLIC HEALTH•FIRE MARSHAL RECEIVED
v,�D
615 W.Alder Street,Shelton,WA 98584
- - Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone JUN O 5 2Ot9
Belfair. (360)275-4467•Phone Elma:(360)482-5269
1854
BUILDING PERMIT APPLICATION 615 W. Aider Street
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: S A 1V NAME:
MAILING ADDRESS: 15; /// Suer`iS e Gt JJ uJ MAILING ADDRESS: -7 t 't Green �cNa e too Sw
CITY: pt STATE: q- ZIP: `e56 CITY: (}l'J m P t c. STATE I.--4- ZIP:
PHONE#1:— bra- -7gq_ (o-i Lt PHONE S.-g55-►Sc�CELL: S— --
PHONE#2: EMAIL : S R V A I- K ov 7 E (�) 6 r..., 1 .
EMAIL: In-S N ccs— L&I REG# EXP.
PRIMARY CONTACT: OWNER❑ CONTRACTOR,E OTHER❑
NAME EMAIL
MAILING ADDRESS CITY vl` Ml✓L STATE �-Ata ZIP c3e.S/C
PHONE CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 4 Z Q 0 Z Z 4 00 S G ZONING ,L N /D U S((�a
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITEADDRESS I&O ItJ W,-5 t-4 idd Ca' CITY
biRECTIONS TO SITE ADDRESS u t 'r-6 l7and+�. t-r r-,, -4- (L�
&f 4-P Zn c(^ a--n-4.
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO [?"
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): 10ori-{
SALTWATER❑ LAKE❑ RIVER/CREEK ❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM❑
TYPE OF WORK: NEW er ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.
IS USE: PRIMARY rl' SEASONAL ❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS__
HEATED STRUCTURE? YES(Whole Bldg) a YES(Part[s]of Bldg) ❑ NO ❑
DESCRIBE WORKS LL �' C 0 12E — C A 53 1 OC e S5 i,n Gj 0 A
SQUARE FOOTAGE: (propose+existing)
IST FLOOR LS t;F) sq.ft. 2ND FLOOR_ -,JZ sq.ft. 3RD FLOOR_ sq. ft. BASEMENT O' sq.ft.
DECK_sq.ft. COVERED DECK_ sq.ft. STORAGE �3rZ sq. ft. OTHER ,90' sq. ft.
GARAGE_0 sq.ft. Attached❑ Detached❑ CARPORT ff sq. ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE ( ,(,(k MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC P' SEWER❑ / NEW[-" EXISTING ❑
PLUMBING IN STRUCTURE? YES NO ❑ If yes, attach completed Water Adequacy Form
PERIMETER&OUNDATION DRAINS PROPOSED? YES ❑ NO[�f- EXISTING SQ.FT.
EXISTING BEDROOMS ?tl PROPOSED BEDROOMS (� TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed. I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF ONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT AP ICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON
COUNTY CODE 14.08.42)
Signaturo,of WNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
SUN GROWN FARMS C ' �
S r
77 �• .#� v`." 9 +Yi.r. s w*a�iaeMsr tea.we
` 11! 14j
,. . ,ter r.km. { _
A
y ASp1V COtjp Pp q-r, ®VE®
If'9.y � a r ♦ i S/TE PLAN �va../ ,'i.l
CHANGES
kEQUIR r� A/ II/V
BY s SU'Jit r 3EApp oN SATE
E Date AL
E •• i
i
iti
i
{
{ � ,�• �t.Rf- � i � tQ'-` 7r tel: 4MXk
r
6 k
i
'4 r%,.aA OM'fie
a gy va
f :!B rrr mat.•.+et`
vw f t
M I i
, ♦. �t##�yR.aw�IwnI�IM�+At r t
y >
,H h : .,, z.
20 ES,4i nT
` . A,.
INTINC
p �
� t 1
. F,'t SttARTy;YF_
WdC f X 94G'4FRQA3G AREA x 1G4'GR< 1
�EEk
SYSTEM • ;.
CASEMENT
20'*AtER
PO'i.£R€ASEMEw \ f 1
# 16G'%104`GRD'MFvGAREA E
19,','x 146'cEinT Ale-
CFAVYL 2W
615, : ' . � ' - i ��
� Y 267'k 160'CfitlMtrC AREA
34• �¢
i
i n
_p� sear L"
� +—sca,ceuaen _uezV >_
RROr'C 71'X 141'GROW NG AREA 74 X 41
BuaIl�IG
( { AREA
F
t x
e a
i
iRRIGAT„N K Lt ..
E]
4 (r / ;� 6Q'ACCESS AND
r i3ja ti11liDES EASENENT
W � ?
i 3 % — _ -- - - - _- - — — — — —
APPROVED
30 0141 tES EASEMENT~ COW'SLYER t9k £CATED FD 4AST,S1ES1, MASON L J N F Y C L}
EASEMENT ? ( p1b S,AN4 CASCADE NATURAL GAS .
SITE PLAr1? REQt,1RED To BE ON SITE
CHANGES ,3uLijEC r TO APPROVAL
BY �.
Z
rnn
Q
�z
yid
z
G)
0
2
Z
N
O
RL
rt
N
Z
m —
•
N
G
A
9
s
o
B C)
co
O_ -
rn cn
O X m O
W O O m OO
(A m a_
co
t0 < d
V m CN
• O
m
r� m
K
a
CA
O
W
(A
co
w
V
m
� O ,
[»
V1 co
z
rZ 0
P
r —
�z
v
v
O
D
F
z 12'-0" o z w 12'-0"
Duo
of crn � ,'i
N o �
s
� 9 m
il z cn
I
o v�
CD
� Z
z �
c�
0
� 12'-0" 12'-0"
0
z
D
Z
O
m
z
c
Cn U
ri
z Y
a
Z
m
o i> o
GO
f\. co O I - O --- -
> D mCnn� rZ U) m Y m
N Z7Of z m m
N
D r ICJ r i
v hoc)
ro DDn to m
9 m`� � Z ��
OD N ,mC) r
W Z Z H
C) =gym 0 m n
moD rn m M
-0h 0 c p
zg� m �
0 0° co mm C'
3 �p r ZO Cn 0
co P > I I
o c1
z 0
I� � o
w a?
Q
0, <
µ N y 10 Y
\£ w
N cm (D Am IC-1
b� b
nrn corn
x x
i � m
f
E
N H �
t �R
i
° <Li
r-
ro �
n
m
M p1!
f' I
t
;�3 3333
�m
m m E,4
z o m m x 0
.,i nQ cbiE
fi Apop �� b~ b MI .o 3 LO
rt
C LL [nsJ O. H
O p °< O p i7 17 y O I'f
Y
Q £ £ C V M OL (}
CD 0
NO O O y y Y�
0 O 1mb Z
9 3 z
8
�t H :� o C y�C�--
w n Y O E ypy CQ1
`z-7
£ £ Q [h
?Y
W W
W
b
p
ti
... TA!
t I
Brand Management Tenant Improvements s
• �a Floor Plan 4 160 West Westfield court Unit A
Nd a Shelton WA 98584
0
Y i d d
ami
SEC 2,T20N.R04W,W.M.
I l i l
91ARW WELLS
312.
<<
I + `1 I ' I II T 250'X 160'GROWING AREA
w
WATER Ir li I/
�\ ( SYSTEM
EASEMENT
00
_
La. - L31 -
GRAVEL 20'
20'WATER AND Il a
POWER EASEMENT
T-='42002 24-90050 j
LO7 4 i
4-c AG I�
I � I ;� s3 267'X IW GROWING AREA
19
. i
_
W ' - -- --f -
PRIVATE NtGATION WELL 20 AVEL.
APPROVED '
- -
_� - ---- -
MASON COUNTY OCD F' IL��JNIN
SITE PLAN, REQUIRED TO F3E1 �NISITE
CHANGES SUBJECT TO AP���IAL
267'X 160'GROWING AREA
,y_� Late
I`
41,
I i{ I
{ SEPTIC TANK
_.
I ' 3 SEPTIC ORAINTTELI}
2V _.
PROPOSED i
' if ''. ' BU0.GNG 180'X 68'GROWING AREA
" a
.�I .." ..
I
i� _P'_'7_..,
F.---- - i PRIVATE IRRIGATION WELL
El
60'ACCESS AND
- _ -1 Il -d _�/ UTILITIES EASEMENT
W
— tiA-GT3 .) Lu — — — — — — — — — — — — -
I 10'UnUTIES EASEMENT
IVEASEMENT
NLUNE I I DEDICATED TO COMCAST•WEST, E y E V
PUD 3,AND CASCADE NATURAL GAS i
JUN Q ^T 19
f to Brand ManageMent Tenant Improvements
• N SITE PLAN 160 West Westfield Court Unit A �5 W
u Shelton WA 98584 1 d W. Alder Street
I-- o u
r
u
MASON COUNTY
{ COMMUNITY SERVICES RECEIVED
Building.Planning,Environmental Health,Community Health JUN 0 5 2019
Physical and Mailing Address: 615 W Alder St.,Bldg 8, Shelton, WA 98584 615 W. Alder Street
Shelton Phone: (360)427-9670 ext 352 •:• Fax (360)427-7798
IpLn
PLUMBING & MECHANICAL PERMIT APPLICATION Permit#: t
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Y-24W Y � e b�) NAME: SG;rvlF'S" klL.1 -ITV J.kC
MAILING ADDRESS: ':Di) c'-T MAILING ADDRESS: '3 3 i-2
E— —
CITY: r t�,�► tit STATE: ZIP:`� CITY: Q` qor Vti STATE: ZIP: `78-97_ 1
1st PHONE! PHONE: CELL:
2nd PHONE: EMAIL: S N✓+3GUt/�(/?E` cr<> . c��`
EMAIL: L&I REG# /aa- EXP.
PARCEL INFORMATION: 24� 22 00 '`_
PARCEL NUMBER (12DigitNumber): ` 2.0Q L4 19 0 Zoning:
LEGAL DESCRIPTION (Abbreviated:
SITE ADDRESS: I r_,0 L vJep `�T" �� r_C CITY:
DIRECTIONS TO SITE ADDRESS: '�, 1 d 1 1,��-�.f o� -' t{'a{ � 1� 4rl^
TYPE OF JOB/WORK: NEW ADD ALT REPAIR OTHER
USE OF BUILDING <_' V( r2 +n ck (1 0 rC - ( c,"r\na -bt '7' \R'r`,( <-'i 0-f
PLUMBING FIXTURES MECHANICAL UNITS [] Electric in-wall heaters(notee)
Type of Fixture No. of Fixtures Fuel Type Fees Type of Unit No. of Units Fuel Type Fees
Toilet(s) ( Furnace [E/G/LPG]
Bathroom Sink(s) , Heat Pump [E/G/LPG]
Bath Tub(s) b o Ductless H.P. [E/G/LPG]
Shower(s) Spot Vent Fan
Water Heater(s) 0 [E/G/LPG] Propane Tank gal.]
Clothes Washer(s) J [E/G/LPG] Gas Outlet(s)
Kitchen Sink(s) '> Heat Stove [E/G/LPG/W]
Dishwasher(s) Kitchen Exhaust Hood
Hose bib(s) t Dryer Vent
Other ( Solar Panel
Other C) Other
Plumbing Subtotal Mechanical Subtotal
Plumbing Base Fee Mechanical Base Fee
Final Inspection Fee Final Inspection Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to
do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this
project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not
commence within 1 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF
INSPECT IO NA TIV OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
I
X � ��� l � Gi�?
Sign !re of Applicant Date�e
x - Owner/Owners Representative/Contractor
Prm Name (Circle one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
O Building
O Fire Marshal
O Permit Tech (OTC permit only)
Project Title: Brand Management .Date 08/15/2019
If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is
required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information
shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms.
VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.)
DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR
AG=Above-grade
Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door
Project Areas-> VF= NW= DR=
Existing Non-project Areas- VF= NW=
Gross Exterior Max Vert. Fen.% Maximum Target
AG Wall Area (C402.3.1) Vert. Fen.Area
�( 30.0% — 100 =
Total Vertical Delta Vertical Excess Vertical
Fenestration Maximum Target Fenestration 0 Fenestration
II greater =
Multiplier applied to all
Project Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical
Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to
_ calculate Target Vertical
Fenestration Area
Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all
+ _ _ �� = Proposed Opaque Above- "
Grade Wall Areas to
Tar et Areas - UA calculate Target Above-
Target Grade Wall Area
Commercial
Vertical Fenestration Proposed Area Target VF Mult. Target Area
Non-metal frame X —
Metal frame,fixed X
Metal frame,operable X —
Metal frame,entrance door X
Target areas in shaded
Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to
Steel Frame X = target areas on ENV-UA
Metal Building X
Wood/Other frame X —
M ass X —
Mass Transfer Deck X —
Group R Mass X
tat above-grade
Sum of Proposed Sum of Target J
sum walla d vertical
fenestration areas are
Target Areas - SHGC x A calculated to equal the
g sum of proposed
Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area
PF<0.2 X —
0.2<_PF<0.5 X —
PF>_0.5 X = SHGC target areas in
shaded boxes are applied
North Vertical Fenestration _ to target areas on ENV-
PF<0.2 X = SHGC
0.2<PF<0.5 X —
PF>_0.5 X =
i
a
'Skylight
• Area Adjustment Calculations
Project Title: Brand Management .Date 08/15/2019
If skylight area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is required. This
worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in this
worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms.
SKY=Skylight NR-Net roof(excludes skylight) Gross Exterior Roof Area=SKY+NR
Proposed Areas Skylight Net Opaque Roof
Project Areas-> SKY= NR=
Existing Non-project Areas-> SKY= NR=
Gross Exterior Max Skylight% Maximum Skylight
Roof Area (C402.3.1) Fenestration Area
X 5.0$ - 100 =
Total Skylight Area Maximum Target Delta Skylight Area 0 Excess Skylight
— = II greater =
Project Multiplier applied to all
Skylight Area Excess Skylight Target Skylight Area Total Skylight Area Target SKY Multiplier Proposed Skylight Areas
to calculate Target
Skylight Area
Net Project
Roof Area Excess Skylight Target Net Roof Area Net Roof Target Net Roof Mult. Multiplier applied to all
Proposed Opaque Roof
+ I — — Areas to calculate Target
Roof Area
Target Areas - UA and SHGC x A
Skylight Proposed Area Target SKY Mult. Target Area
All X =
Roof Proposed Area Target Net Roof Mult. Target Area
_ Target areas in shaded
Insulation Above Deck
X boxes are applied to target
Metal Building X areas on ENV-UA
Joist/Single Rafter X -
Attic/All Others X =
Sum of target roof and
Sum of Proposed Sum of Target skylight areas are
calculated to equal the
sum of proposed
i
Calculation
2015 WSEC Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Oct 2017
Project Title: Brand Management Dafe 08/15/2019
Target Insulation Allowance: For Building Department Use
Component Performance Not Selected
Fenestration Area as%gross above-grade wall area 2.7% Max.Target: 30.0%
Skylight Area as%gross roof area Max.Target: 5.0%
Vertical Fenestration Alternates: None Selected on ENV-SUM
Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed
fenestration areas in ENV-UA.
2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically
adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation.
3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the
default value per Section C303.1.3.
4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. FU.e,Note
Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation.
Skylights Proposed SHGC Target SHGC
Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x SHGC x Area(A)= SHGC x A
0.35
SHGC 0.35
Skylight Totals
All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++
PF
Sch. ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)'=SHGC x A Category SHGC x Area(A)= SHGC x A
PF<0.2 0.40
0.2<PF<0.5 0.48
PF>_0.5 0.64
++If projection factor(PF)credits are
applied to the proposed design, Target
SHGC will sum fenestration area by PF
category.
+If PF credit is applied,then vertical fenestration Non-North Window Totals
must be entered in the correct table according to
orientation. If credit is not applied then all vertical
fenestration can be entered in either table.
North Vertical Fenestration+ Proposed SHGC Target SHGC++
PF SHGC x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A
Sch.ID Provide SHGC source and fenestration schedule ID Category
PF<0.2 0.53
0.2:5PF<0.5 0.58
PF>_0.5 0.64
++If projection factor(PF)credits are applied
to the proposed design, Target SHGC will
sum fenestration area by PF category.
North Window Totals
C x A
TO COMPLY-The Proposed Total SHGC x A Area SHG Area SHGC x A
shall not exceed the Target Total SHGC x A. Total(Skylight+Window)
Component Performance Compliance (SHGC) Compliance Performance Not Selected
f
Lighting, Motor, andElectricalPermit Checklist, •
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3stories and all R1 Revised July 2016
Project Title: SUNGROWN FARMS Date 9/5/19
The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the Washington
Slate Energy Code, Commercial Provisions.
Applicability Location in Building Department
(yes,no,na) I Code Section Component Compliance information required in perm it documents Documents Notes
LIGHTING CONTROLS
C405.2 Lighting controls, For all light ng fixtures,indicate lighting control method on plans for
general spaces and lighting zones served,or exception taken
Luminaire level lighting Indicate on plans all fixtures provided with U-LC in lieu of C405.2
C405.2 controls(LLLC) lighting controls;provide description of control capabilities and
perform parameters
Lighting in dwelling For permanently installed lighting fixtures in dwelling units,indicate
C405.1 units lighting control method on plans for spaces and lighting zone(s)
served,or demonstrate compliance with high efficacy exception
C405.2.3 Indicate on plans the method of manual lighting control(whether
C405.2.1.1 combined with occupancy sensor,automatic light reduction, daylight
C405.2.2.2 Manual controls
C405.2.4 responsive or specific application controls),location of manual control
C405 2 5 device and area or specifice application it serves
C405.2.2.1 Manual interior luting Indicate on plans which method of manual 50%lighting load reduction
C405.2.2.2 controls is provided,or whether lighting load is reduced via occupancy sensors
C405.2.3 or daylight responsive controls
Indicate on plans the method of automatic shut-off control during
unoccupied periods(occupancy sensor or time switch)for all lighting
Method of automatic zones;
C405.2.2 ---------------- -------- ------------------------------------ ----------------------
shut-off control Indicate locations where automatic shutoff is provided by other
methods(occupancy sensor or digital timer switch)or which time OCE SENSOR
switch control exception appil ies
Indicate on plans the spaces served by occupancy sensors;
C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to be
C405.2.1.1 controls manual-on,automatic 501/6-on,or serve a space eligible for automatic
1001/.-on per exception
C405.2.1.2 Occupancy sensor Indicate alsletvays and open areas in warehouse spaces provided with
controls-warehouses occupancy sensor controls that reduce lighbrig power by 50%
C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is
used
C405.2.2.1 Automatic time switch Indicate locations of override switches on plans and the lighting
controls zone(s)served,1ncude area sq.ft.
Indicate primary and secondary sidelight daylight zone areas on plans,
includesq.ft.;
C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include sq.ft.;
C405.2.4.3 Sidelight and topflight For small vertical fenestration assemblies(rough opening less than 10
percent of primary daylight zone)where daylight responsive controls
are not required,provide fenestration area to daylight zone
calculations)
Indicate on plans lighting zone(s)served by daylight responsive
controls;
----- --------------------------------Identify sidelight sidelight and toplighl daylight zones that are not provided with
Daylight responsive Wight sensingcontrols and the exception(s)that apply,
C405.2.4 controls Indicate on plans the lighting load reduction method-continuous
dimming,or stepped dimming that provides at least two even steps
between 0/0 1001%of rated Power:
................................... .... ........................................................................................ ....................................
Indicate that daylight sensing controls are configured to completely
shut offall controlled lights inthelightingzone
Additional controls- Identify spaces and lighting fixtures on plans that require specific
C405.2.5 Specific application application lighting controls per this section
lighting controls
Indicate on plans that display and accent lighting,and display case
C405.2.5- Display and accent lighting are controlled independently from both general area lighting
Itemsl&2 lighting land other lightingappflications within ftsamespace;
Indicate manual and automatic lighting lighling control method
Lighting, Motor, • • ElectricalPermit Checklist, •
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 016
Project Title: SUNGROWN FARMS Date 9/5/19
The following information is necessary to check a permit application for compliance with the lighting, motor,and electrical requirements in the Washington
Applicability Location in Building Departmant
(yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes
C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key control
Item 3 roans of all installed luminaires and switched receptacles in guest room
C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy control for
Item 4 lighting supplemental task lighting,including under-shelf or under-cabinet
li Nin
Indicate on plans eligible non-visual lighting applications,include sq.ft.
area of each fighti control zone; _
C405.2.5- Lighting for non-visual Indicate on plans that non-visual lighting are controlled independently
Item 5 applications from both general area lighting and other lighting applications within the
same space;
Indicate method of m anal lighting control and applicable automatic
lightinq control
Indicate on plans that lighting equipment for sale or demonstration are
C405.2.5- Lighting equipment for controlled independently from both general area lighting and other
Item 6 sale or demonstration lighting applications within the same space;
Indicate method of manual lighting control and applicable automatic
Ii hti rig control
Identify on plans egress fixtures that function as both normal and
emergency means of egress illumination; ................... ..... ...................................
C405.2.5- Means of egress Provide colcula_tlon of li�htirx_power density of total egress Ii�Min �
Item 7 lighting If total egress lighting paver density is greater than 0.02 W/sq.ft.,
indicate on plans egress fixtures requiring automatic shut-off during
unoccu�ed periods; y
Indicate method of automatic shut-off control
Indicate on exterior lighting plans and fixture schedules the automatic
li htin canVol method,controls uence,and local onus served;
For building fagade and landscape lighting,indicate automatic controls
shut off lighting as a function of dawn/dusk and fixed opening/closing
C40527 Exterior I ighti ng time; _________ _ _____
controls Fa all other exterior lighting,indicate automatic controls shutoff
lighting as a function of available daylight;include control sequence that
also reduces lighting power by at least 309%between 12am-6am,or
from 1 hour after closing to 1 hour before opening,or based upon
motion sensor
Exterior building For building grounds fixtures greater than 100 watts,indicate on plans
C405.5.1 grounds lighting whether fixtures have efficacy greater than 80lumens or;are
controls controlled by motion sensor,or are exempt lighting C405.5.2
Indicate location(s)of master control switch(es)intended to control
Area controls-Master multiple independent switches;circuit breaker may not be used as a
C405.2.5 control switches and master control switch;
circuit power limit Verify that no 20 amp circuit controlled by a single switch or automatic
control is loaded beyond 80%
To comply with additional efficiency package option,indicate on plans
all interior lighting fixtures that are individually addressed and provided
C406.4 Enhanced digital with continuous dimming,or exception taken;
... _ _
lighting controls Include calculation of percent total installed interior lighting power that
is configured with required enhanced lighting control functions(min
90%to com pl y with additional effici ency package option
Ifclaiming lighting system commissioning exemption provide
supporting calculation;
....................................................................................................................................................................... ....
C405.13 Lighting system Identify applicable commissioning documentation requirements per
C408.3 functional testing Section C408 or eligibility for exception;
Provide written procedures for functional testing of all automatic
controls and describe the expected system response
Exterior • •
Project Title: SUNGROWN FARMS Date 9/5/19
Exterior Lighting For Buildinq Department Use
()Zone 1 OZnne 2 OZane 3 O Zane 4
Zone Table C405.5.2(1)
Specified by jurisdiction. Zone selection required to enable LTG-E?CT form
Calculation Area OAddition -stand Addition
alone +existing
QAlteration with<509/6 QAlteration with>_500/6 ext.
Building Grounds CEfficacy>80 lumenshwatt CExemption
Applies to luminaires>
100 watts CControlled by motion sensor
Tradable Maximum Allowed Lighting Wattage""' ease site Allowance: o
Area(fe),perimeter(If) Allowed Watts Aliawed Watts
Tradable Surfaces Surface Description or#of items r ft2 or r If x e or x I
Total Allowed Tradable+Site Allowance Watts:
Tradable Proposed Li Yhting Wattage"OTE z
Number of Watts per Wafts
Tradable Surface Fixture Description NOTE 3,4 Fixtures Fixture NOTE 5 Proposed
Total proposed tradable watts may not exceed the scan of total allowed tradable watts Total Proposed Tradable Watts:
plus the base site allowance. Any base site allowance riot needed to make tradable
watts comply can be applied to individual non-tradable categories.
Non-Tradable Maximum Allowed Lighting Wattage NOTE' Site Allowance Remaining: o
Area(e),perimeter(If) AflawedWatts Allowed Watts
NarTradable Surfaces Surface Description or#of items per W or Der If x ft2 a x I
Non-Tradable Pro osed Lighting Watta a NOTE z
Number of Watts per Watts
Non-Tradable Surface Fixture Description NOTE 3,4 Fixtures Fixture NOTE 5 Proposed
Non-tradable proposed watts may riot exceed allowed watts for any individual surface Nan-Tradable Watts Exceeding LPA:
unless the total excess watts for all iron-tradable surfaces are less than fhe remaining Remaining Site Allowance:
site allowance.
Exterior Lighting
Note 1-List all unique exterior sufaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop
down menu.
Note 2-List all proposed lighting fixtures including exisfing-to-remain fixtures.
Note 3-For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type(ifapplicable).
Note4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the samemanner
as new fixtures.Identify as existing in fixture description.
Note 5-For proposed WattslFixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage). For low
Building Area types and gross interior areas. "`
Summary
ray Code Camnliance Forms for Commercial Build nag inclLidtna R2.R3.R4 over 3 stories and a I R1 Revised July 2016
Project Info , Project title: SUNGROWN FARMS Date 9/5/19
Compliance Applicant Information. Provide contact information for individual who can respond For Building Department Use
forms do not to inquiries about compliance form information provided
require a Company Name: SUNGROWN FARMS
password to
use. instructional Company Address: 5111 Sunrise Beach Rd NW Olympia WA 96502
and calculating
cells are write- Applicant Name: SEAN KIRBY/JAMES VANHOUTE
protected
Applicant Phone: 253-985-1520
Applicant Email: seanikirby@msn.com
Project Description C New Buildng CAddition E Alteration Plans Included
Include PROD-SLIM form(included in envelope forms workbook) with fighting canpiliaice forms.
Building Additions Compliance Method Interior lighting Exterior lighting
Lighting systems in addition area comply with all applicable ❑ 1""
Refer to Section C50226 for addtfonal ovisions as a stand alone new construction project L—
requirements. Lighting systems in addition are combined with existing ❑
building lighting systems to demonstrate compliance
Addition is combined with existing:
For interior lighting projects,include new+existing interior fighting fixture wattage in Proposed Lighting
Wattage table in LTG-INT-BLD or LTG-INT-SPACE form.
For exterior lighting prcyects, include new+existing exterior fighting fixture wattage in Proposed Tradable
and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form.
Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting
Lighting Alterations 5(r/o or more of existing are replaced C
Select all Lighting Power and Lighting Less than 50%of existing are replaced C
Control elements that apply to the scope of
the retrofit project ifpr4ect includes a
combination of spaces where less than Lamp and/or ballast replacement only —
5001.of the existing fixtures are replaced in existing total wattage not increased C
some spaces, and 50'1.or more of the 5tr/a or more replaced -Total lighting power of new+existing-to-remain fixtures shall comply with total LPA
fixtures are replaced in others, then provide per Sections C405.4.2 and C405.5.2 Include new+existing-to-remain fixtures in Proposed Lighting
separate lighting power compliance forms Wattage table in LTG-INT-BLD, LTGiNT-SPACE or LTG-EXT form.
for the two retrofit conditions. Spaces undergoing the same We of retrofit may Less than 50'/o replaced-Total fighting power of new+existing-to-remain fixtures shall not exceed the total
be combined into one fighting power lighting power prior to alteration. Include new+existing-to-remain fixtures in the Proposed Lighting Wattage
compliance form. table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50%threshold applies to number of luminaires for interior spaces and parking garages, and total installed
Refer to Section C50a 6 for additional
requirements. Lighting Controls Interior lighting Parking garage Exterior lighting
New wiring installed to serve added
All alteration fighting controls shall be fixtures and/or fixtures relocated to new C C
circuit(s)
New or moved lighting panel C
Interior space is reconfigured - ❑
luminaires unchanged or relocated only
........ ...........................................................................................................
New wiring or circuit-For interior fighting, provide required manual controls per C405.23, occupancy
sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific fighting
No changes are being made to controls per C405.25. For exterior lighting, provide required controls per C405.2T
the interior or exterior lighting New or moved panel-Provide all applicable fighting controls as noted for New Wiring and automatic time
systems and existing space uses switch controls per C405.22
and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior space.
changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces.
Change of Space Use ❑Existing interior lighting systems in areas under-going a charge in space use are upgraded to comply
with LPAs for the new space types per Tables C405.4.2(1) or C405.42(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in
LTG-INT-BLD or LTG-INT-SPACE form.
i. I L
• • Summary, cont.
2015Washinaton State Eneray Code CornolianCe Forms for Commercial Buildings includi no R2.R3-R4 over 3stones and R1 Revised July ZQ_J.CZ
Project Title: SUNGROWN FARMS Date 9/5/19
Interior Lighting System INTERIOR OF PROCESSING BUILDING
Description
Interior Lighting Power 1:1Building Area Method ❑i Space-by-space Method
Allowance Method Select method used in project.
Interior Lighting Controls nAlI C405.2.1 -C405.2.s Controls [C405.2 Exception 5 Luminaire Level
CAdditional Efficiency Package Option
To comply with C406.4. no lass than 90•1 of the total installed interior lighfing power shall comply with the
required controls per C4064.
Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: .
Lighting CC405.2 thru C405.5 Commercial Lighting Controls and LPA
CC4W.3 High Efficacy Lighting
C
Exterior Lighting System N/A
Description
t
f
i
Project Title: SUNGROWN FARMS Date 9/5/19
Calculation • OAddition - O Addition For Buildinq Department Use
Area NOTE s stand alone existing
QSpaces where<50%of QSpaces where a 50%of O
LPA
QStaudad OArioltional Efficiency Package Option
Calculation
To comply with C406.3, the Proposed LPD shall be 25%tower than the Target LPA.
Type Refer to C406.3 for additional requirements.
Maximum Allowed Lighting Wattage NOTE'
Location(plan#, Ceiling Gross Interior Allowed Watts Allowed
room Space Type HeiqhtNOTE 2 Area in ft2 Watts per ft2 watts/ft x area
1 Warehouse:Medlumlbulky palletized items #N/A #N/A
Total Area
Retail Display Allowance from LTG-INT-DISPLA 1, j
Lobby ArtiExhibHt Display Allowance from LTG-INT-DISPLAY NOTE a� Allowed Watts
Proposed Li ing Wattage NOTE 3
Location(plan#, Number of Watts/ Watts
room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed
1 4'2LAMP 13W LED 12 26 312
Proposed Retail Display Lighting from LTG-INT-DISPLAY
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 312
Interior Lighting Power Allowance
Note 1-List all unique space types per Table C4054.2(2) that occur in the prgect scope. Select space We category per from drop down menu.
Note 2-indicate ceiling honght for atriums and spaces utilizing the ceiling height aqustment per Table C405.4.2(2), Footnotes d thru f.
Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures.
Note 4-For proposedFixture Description, indicate fixture type, lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(ifincluded). For
track lighting, list the length of the track(in feet)in addition to the fixture, lamp,and ballast information.
Note 5-For lighting e*pment eligible for exemption per C405.4.1, note exception number and leave Watts*ixture blank.
Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing
in fixture descriptian.
Note 7-For proposed WMY&Fixture enter the lurninaire wattage for installed lamp and ballast using marnnacturer or other approved source. For
luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture(mot the lamp wattage). For low voltage
lighting, enter the wattage of the transformer. For line voltage track/busway systems, ender the larger of the attached luminaire wattage or 50
wattsAineal foot, or enter the wattage limit of permanent current limifing device.
Note 8-Lobby ArtlEXhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage.
Note 9-Calcination Area Details:
a. Lighting fixtures in a building addition may comply as a stand alone prgect, or they may be combined with the overall existing building
luting systems to demonstrate coampliance. Refer to C502.1.
b. For alterations and building additions, provide Space Types and grass interior areas in the Maximum Allowed Luting Wattage table if a
bualdling addition will comply as combined with the overall existing bunlolng lightng systems,include all applicable existing Space Types
and grass interior areas.
c. ff less than 50%of existing lighting fixtures will be replaced, provide total existing luting wattage (prior to alteration) in the space provided
Interiori • • i Space-by-Space 1 1
2015 Washington State Enecgy Code Compliance Fiarmg for Commercial Buildings including R2 R3.R4 over 3 stories a A all R1 Revised.J la
Project Title: SUNGROWN FARMS Date 9J5J19
General Note-In Sales areas, an increase in lighting power allowance is permitted for lighting installed For Building Department Use
specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible
merchanise display lighting may be included in the Gross Interior Area under each Retail category. This
lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display
Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to
general area lighting.
Maximum Allowed Retail Display Lighting Wattage
Location(plan#, Gross Interior Allowed Watts Watts Adlawec
room#) Retail Sales Area Type NOTE I Area in ft Per f, NOTE 2 watts/fe x ar
Total Retail With Display Area Total Watts
Retail Display Lighting Base Allowance
Maximum Retail Display Allowance NOTE 3
Proposed Retail Display Lighting Wattage NOTE 4
Location(plan#, Number of Watts per Watts
Retail Area room#) Fixture Description NOTE 5 Fixtures Fixture NOTE s Proposed
Total Retail Proposed Display Watts NOTE T
Retail Display Power Allowance NOTE a
Proposed Retail Display Lighting Retail 1 Retail Retail 3 Retail
Totals from LTG-INT-DISPLAY
Note 1-Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.22.1 may be entered in this table.
Note 2-Retail display lighting power allowances per C405.4.2.21, Equation 4-11.
Note 3-Maximum retail display wattage allowance as calculated per C4054.2.2.1, Equation 4-11.
Note 4-Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in
this table.
Note 5-For proposed Fixture Description, list ALL proposed display lighting Fixtures, indicate fixture type, lamp type (e.g. T-8),number of
lamps in the fixture, and ballast type(if included). For track lighting, list the length of the track(in feet) in addition to the fixture,
lamp, and ballast information.
Note 6-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.
For luminaries with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage). For
low voltage lighting, enter the wattage of the transformer. For line voltage track1busway systems, enter the larger of the attached
luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device.
Note 7-Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG-INT-SPACE.
Note 8-Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed
Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in
LTG-iNT-SPACE.
Note 9- Enter a unique title for each lobby area in project that has artlexhibit display lighting.
Note 10-Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c =0.5 WM2.
Note 11 -Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table.
Note 12-Only separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of
general area lighting, maybe entered in this table.
Nnta 1.3-i nhhv Art/Fyhihit r)i.cnlav Allrwanrp bz antnmatina0v nntorad in l Tr:_INT-RPArF
Interior Lighting - Building Area Method LTG-INT-BLD
Project Title: ,SUNGROWN FARMS Date 9/5/19
Calculation O •Addition - OAddition For Building Department Use
Area NOTE 8 stand alone +existing
OSpaces where<50%of OSpaces where>_SM. of O
LPA OStandard OAdditional Efficiency Package Option
Calculation
To comply with C406.3, the Proposed LPD shall be 25•0 lower than the Target LPA.
Type Refs*to C406.3 for addfional requirements.
Maximum Allowed Li htin Wattage NOTE ,
Location(plan#, Gross Interior Allowed Watts Aillowed
Building Area room#,or ALL) Area Description Area in a Watts per if wattsbe x area
3000 Unlit
Total 3000
Proposed Li ing Wattage
Location(plan#, Number of Watts per
BuildingArea room Fixture Description NOTE 2,3,4,5 Fixtures Fixture NOTE s Watts Proposed
1 4'2 LAMP 13W LED 1.2 26 Not Defined
Compliance b Building Area NOTE?
Total Allowed Total Proposed Interior Lighting
BuildingArea Warnings Watts Watts Power Allowance
Note 1-List all unique bolding areas per Table C405.4.2(1) that occur in the Totals
project scope. Select building area category from drop down menu.
Note 2-Proposed fixtures must be listed in the buildng area in which they occur.List all proposed lighting fixtures includng exempt
lighting equipment and existing-to-remain fixtures.
Note 3-For proposed Fixture Description, indicate fixture type, lamp type(e.g. T-8),number of lamps in the fixture, and ballast type(ifinciuded).
For track lighting, list the length of the track(in feet) in addition to the fixture, lamp, and ballast intomafion.
Note 4-For fighting equipment eligible for exemption per C405.4.1, note exception number and leave WattsJFixture blame.
Note 5-Exisfing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as
existing in fixture description.
Note 6-For proposed Watts/Fixture ender the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw-in lamps, ender the manufacturer's listed maximnarn input wattage of the fixture(not the lamp wattage). For low voltage
lightng, ender the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or
50 watts/lineal foot or ender the wattage limit of permanent current limiting device.
Note 7-Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Buildng Area type. Trading wattage
between Building Area types is not allowed under the Boidnng Area Method compliance path.
Note 8-Calculation Area Details:
a.Lighting fixtures in a building addition may comply as a stand alone project, or they maybe combined with the overall existing bolding
lighting systems to demonstrate compliance. Refer to C502.t
b.For alterations and building addition, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage
table. If a buildng addition will comply as combined with the overall existing buildnng lighting systems, include all applicable existing
• • 1 • • • • • • • • • k 0 8W-AVA
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2 16
Project Title: SIINGROWN FARMS Date 9/5/19
General Note-In Lobby areas, an additional wattage allowance is permiited for lighting installed For Buildina Denartment Use
specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting
may use this additional allowance. Proposed display lighting for each Lobby area may rid exceed this
allowance.
Maximum Allowed Lobby Art/Exhibit Display LightingWatta e
Maximum Display Proposed Disph y
Gross Interior Watts Allowed Lighting Total
Lobby Area NOTE 9 Lobby Description including plan#&room#) Area in ft2 Per Area NOTE 10 Per Area NOTE 1
Total Lobby with Display Area
Total Lobby Art/Exh bit Display Allowance NOTE tar--�
Proposed Lobby Art/Exhibit Display Lighting Wattage 107E 12 N
Location(plan#, Number of Watts per Watts
Lobby Area room#) Fixture Description NOTE 5 Fixtures Fixture NOTE 6 Proposed
Total Lobby Art/Exhibit Proposed Display Watts
i
r