Loading...
HomeMy WebLinkAboutBLD2014-00360 Garage, Breezeway - BLD Permit / Conditions - 8/28/2014 r 111biJuLmuII LIIIC tJVV/YL/-/LVL MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 1� RESIDENTIAL BUILDING PERMIT BLD2014-00360 OWNER: DARRYL BICKEL RECEIVED: 4/21/2014 CONTRACTOR: MONNIER CONSTRUCTION LICENSE: EXP: ISSUED: 6/9/2014 SITE ADDRESS: 337 E POINTES DR EAST SHELTON EXPIRES: 12/9/2014 PARCEL NUMBER: 121195000099 LEGAL DESCRIPTION: HARTSTENE POINTE S 34/126 LOT: 99 PROJECT DESCRIPTION: DIRECTIONS TO SITE: GARAGE WITH STORAGE TRUSSES AND ATTACHED BREEZEWAY General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building: Garage-Attached 784 Valuation: $ 34,116.32 Building Height: 28 Occ. Status: Primary Basement: BREEZEWY 56 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 50.0 Ft. Shoreline: Ft. Water Body: na Rear: W 5.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 5.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 30.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee TW 4/21/2014 $293.70 S220140000000i Planning Review Fee TW 4/21/2014 $205.00 S220140000000i EH Minor Plan Review BJS 4/21/2014 $ 100.00 S7201400000001 Building State Fee LDK 5/13/2014 $4.50 S220140000000i Building Permit Fee LDK 5/13/2014 $492.25 S2201400000001 Total $ 1,095.45 BLD2014-00360 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2014-00360 CONDITIONS FOR BLD2014-00360 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X M &k 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. 3) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6!! tk 4) Approved Per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. �%fk 5) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR RQAQWAY. 6) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X �Y 7) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X 0_1 AA, 8) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depa ment prior to any further inspections being performed or approvals granted. X � BLD2014-00360 Please refer to the following pages for conditions of this permit. Page 2 of 5 :) i ne plan review cnecK nst ana corrections are part or ine approvea plans ana must remain triereta. it is me respansiunny ar ure appucanr w rnarce the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X /AM 10) This structure is approved as unheated space. To be considered unheated space the area may be provided with a heating system that does not exceed energy usage of 1 watt per sq. ft., or 3.4 Btu/h per sq. ft. A permit and approval shall be required prior to installation of any heating system. When a heating system exceeds 1 watt per sq. ft(or 3.4 btu/h per sq. ft)the heated space shall be insulated in accordance with the energy code in effect at the time of permit application. X A Pl 11) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X M,,M 12) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X fA tAA 13) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) X oLki'\ 14) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X /V f"k 15) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation drains within 30ft, down gradient of drainfield/reserve area. X M BLD2014-00360 Please refer to the following pages for conditions of this permit. Page 3 of 5 16) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X /�\/"� 17) This structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X j(h 11A, 18) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permil revocation. X 19) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your t.projec X 20) The placement of buildings and structures on or adjacent to slopes steeper than one unit vertical in three units horizontal (33.3% slopes) shall conform to the International Residential Code Section R403.1.7 for descending or ascending slopes. Alternate setbacks may be approved subject to approval of the building official based upon the investigation and recommendations of a qualified engineer licensed in the State of Washington. Such an investigation shall include consideration of material, height of slope, slope gradient, load intensity, and erosion characteristics of slope material. X l t 21) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X M 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building X specctto\r shall be made prior to requesting additional inspections. 23) All property lines shall be clearly identified at the time of foundation inspection. X /A_\ P— BLD2014-00360 Please refer to the following pages for conditions of this permit. Page 4 of 5 24) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with X Mason County ordinances and building regulations. a 25) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X NM 26) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, conn ctors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X fA, 27) Retaining walls needed to support a surcha a such as structures, roads, or to support slopes, shall require a separate building permit and approval prior A to construction of the retaining wall. X m' OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. cvdc �h 114 Signature q Date hp,r:' r G-1,4k. L. L-L /VVkE /_� Y\A- ,r OWNER - REPRESENTATIVE - CONTRACTOR :�) Print Name (Circle one to indicate) BLD2014-00360 Please refer to the following pages for conditions of this permit. Page 5 of 5 Do o CONCRETE MECHANICAL MANUFACTURED HOME n Footings t Setbacks Gas Piping By Ribbons nI o Interior Date Z/ By interior-Date By Date By r oExterior Date 7 1 / Bl J4 Exterior-Date B Set-up INSULATION > Point Load J Isolated Footings Date By BG f SLAB INSULATION Date By Data By FIRE DEPARTMENT r Foundation Walls Floors Date By Date67- "-/ By;%? Data By DECKS FRAMING Walls Date By Date Zi �N By LOL Data By PROPANE TANKS PLUM IN vault Date By Date By OTHER Groundwork Attic Date By Type_ Date By Date By D.w.v DRYWALL Type. Int.Brace Wall Date By 103 CD Date By hater' FINAL INSPECTION v Water Line Fire Soperation N Date By Date By Date By LJ L m � s Pass or Request Inspect. c E TyR of Insp. Fail Date Date Dane By Comments CD o c 0 -i 4/ cam ' o i nc.1 �sS Zs/N L N O S Vl (D 3 i a `Permit# MASON COUNTY BUILDING Ill 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location '33�7 P`n�s Dr. !% This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance c)C-�O- Ytee& f Lc' -t bG ro c t� r ti,,fi Iti . ti'i( -( et.1'S AA%n -4)cl �. /),1 Le 1 � s You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office W Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection ',�� disasters.This is NOTa Date _ 5/z i I /` t Department 01 L 10 CORRECTION NOTICE. Inspector V Dov NnT R MkjoV ' TH/a TArmw PLANNING V% _ -�� dryry- ' PLANNING—:----" ALL SETBACKS ARE MEASURED FROM THE FURTHEST PROJECTION OF THE BUILDING I RECEIVED APR 18 2014 APPROVED , L 426 W. CEDAR ST.MASON COU`) t-CD PLAN ING SITE PLAN REQUI - - ) TO BE ON ITE j - ' -C, CHANGES S�'- APPRO AL By Name ' Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface. "Redevelopmerrt means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. 'T� £alct�late lmperuus Sauces; se Coijiple#e;Ttais Fab1Q- ..;:. : Surface Type Length X Width = Area 4 All dimensions in feet Buildings X _ X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X X = Any paved, gravel or packed area per definition above table X Patios/Walks X ILI — X Any paved, gravel or packed area per definition above table X = Others X 426 W• - - X = :'If.the total.impervious area of the proposed site - . X = develops is_greater than_2DDD square feet a' mall parcel Stormwater-Bute Plan.is Required:. Total impervtotjs Surface Area:(3urri.bf.`a11 areas) Y 90 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Masson County are granted access to the above, described property for review and inspection as may be required.XN+w (04, J"� Owner/Agen ontractor circle one)Date: �/141J 1 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name Parcel# BLI7# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stornrwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: httT>//www.co.mason.wa—us/code/commissioners/fndex htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48.section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots, The SmaD Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE I\T I BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots,The Smal7 Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail:P 0 Box 1850,Shelton WA 98584 Physical: 415 N 6th St,Shelton WA 98584 If this development has, or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel. You may also wish to consuh with the septic design professional involved with the project Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative, or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 MASON COUNTY PERMIT NO. � � y; DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352 tsu PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 BUILDING PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:�D-r<y I .?; NAME:[1'10'%r'vt f �L,v s��, l.-L L MAILING ADDRESS: 2033 3bz" .Ajz LJ MAILING ADDRESS: CITY: STATE: d= A ZIP:gI lcty--3�3ij CITY:Shc 11aA, STATE: t o ,A- ZIP:q t 5lq PHONE: CELL:U4 yob Ql,13 PHONE:310 Liz? •S0-1-z CELL: Sao die (a3y EMAIL:_rk r r y (tom. e\ (z-� l: w�� EMAIL caul. A:e< L&I REG#Mutin;.lu q otc/U EXP. 2 PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) I Zf\ — j O —060( 'ct FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): SITE ADDRESS 35-7 Po:� s 7r'Je � CITY �h2\ � DIRECTIONS TO SITE ADDRESS IS PROPERTY WITHIN 200 FT: SALTWATER❑ LAKE ❑ RIVER/CREEK ❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO [� TYPE OF JOB: NEW tZ ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) u3z�� "'c,� 51�'c `` c Ltiv�iY �� chi �xTSt► ha,v IS USE: PRIMARY ❑ SEASONAL ❑ ER OF BEDROOMS NUMBER OF BATHROOMS DESCRIBE WORK ,e� SQUARE FOOTAGE: 1ST FLOOR • sq.ft. 2ND FLOOR sq. ft. 3RD FLOOR sq. ft. BASEMENT sq. ft. DECK — sq.fL COVERED DECK:,?;�sq.ft. STORAGE,,44� sq.ft. OTHER GARAGE _sq.ft. ATTACHED DETACHED D§ CARPORT — sq. ft. ATTAC XFMIN" MANUFACTURED HOME INFORMATION: *4 COPIES OF TH FLOOR PLAN 426 W. CEDAR ST. MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. x n ,,� A, wv�-� Signature of Applicant Date XMgri., OWNER/ REPRESENTATIVE /CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT L-0if- 13 / PLANNING DEPARTMENT FIRE MARSHAL