Loading...
HomeMy WebLinkAboutBLD2010-00487 SFR - BLD Permit / Conditions - 7/20/2010 Inspection Line(360)127-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Ir Shelton, WA 98584 flo RESIDENTIAL BUILDING PERMIT BLD2010-00487 OWNER: MALCOLM THOMSON RECEIVED: 6/16/2010 CONTRACTOR: A A& E INC GENERAL CONTRS LICENSE: AAEINGC136DK EXP: 3/11/2012 ISSUED: 7/20/2010 SITE ADDRESS: 150 E WESTLAKE DR NORTH ALLYN EXPIRES: 1/20/2011 PARCEL NUMBER: 122195000044 LEGAL DESCRIPTION: LAKELAND VILLAGE 7 LOT: 44 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR ST RT 3 TO ALLYN, L ON LAKELAND DR, L ON WESTLAKE DR NORTH TO SITE ADDRESS ON THE RIGHT General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp. Area: No. of Bathrooms: 3 Occ. Group: R-3/U Lot Size: Deck: 231 Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,571 Garage-Attached 503 Valuation: Building Height: 28 Occ. Status: Primary Basement:1,272 COV PORCH 18 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 74.0 Ft. Shoreline: 52.0 Ft. Water Body: ANDERSON LAKE Rear: W 52.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: IN 5.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee GMM 6/16/2010 $1,388.50 S12010000 Hosebibs 2 Furnace<100K 1 Planning Review Fee GMM 6/16/2010 $205,00 S120100o0 Kitchen Sink 1 Gas Outlets 1 EH Plan Review SJC 6/16/2010 $103,00 S72010000 Laundry Tray 1 Propane Tank 1 Water Adequacy Plan Review SJC 6/16/2010 $103.00 s7201bbbb Lavatories 4 Ventilation Fan 5 Building State Fee LDK 6/30/2010 $4.50 sinnbbb Showers 1 Heat Pump 1 Building Permit Fee LDK 6/30/2010 $2,136.15 S120100oo Water Closets (Toilets) 3 Propane Stove 1 Mechanical Permit Fee LDK 6/30/2010 $255.90 S12010000 Water Heaters 1 Dryer Vent 1 Mechanical Base Fee LDK 6/30/2010 $28 50 s1201bb00 Bath Tubs 2 Plumbing Permit Fee LDK 6/30/2010 $136.70 S12010000 Clothes Washer 1 Plumbing Base Fee LDK 6/30/2010 $24.70 S12010000 Total $4,385.95 BLD2010-00487 Please referto the following pages for conditions of this permit. 1 of 6 CASE NOTES FOR BLD2010-00487 CONDITIONS FOR BLD2010-00487 1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be 9Nnted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building DepartryMt prior to any further inspections being performed or approvals granted. X 2) Owner gent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) The p review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The ermit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of ap ocuments will result in failure of required building inspections. X 4) All slabs with the heated space shall be insulated to a minim R-10 for at least 24". Monolithic slabs shall be insulated around the perimeter from the top of the slab to the bottom of the footing X 5) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNZ URBED, NATIVE SOIL. X 6) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requeC and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building De rt ent prior to any further inspections being performed or approvals granted. X 7) Washington N4Qate Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the underside e f sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X BLD2010-00487 Please referto the following pages for conditions of this permit. 2 of 6 8) Per IRC SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accorda with the applicable provisions of this section and the manufacturer's installation instructions. X 9) A Mason unty Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish t consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is Howled in g that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 10) Concrete used for basement walls, foundation II , exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete wor exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 11) The international co quires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access roa Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads c nnect ith a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 12) All construcu must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Wash' ton. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocati n. X 13) Provisions for su a/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be locat t:�� of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 14) Placeme f structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 15) All changes to' pproved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or re ation, must be reviewed and approved by Mason County prior to construction. X BLD2010-00487 Please refer to the following pages for conditions of this permit. 3 of 6 16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the inNnational codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector Ah ll be made prior to requesting additional inspections. X 17) All propa nks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10'from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the great f 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards s be installed. X 18) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in th ason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X 19) All propane to ust be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installat 1 requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X 20) Fuel piping shal Qte pected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspe tioes ssure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used n ' t al inspection has been performed and approved by a Mason County building inspector. X 21) The placeme mall propane tanks are no normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regul ns primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think such featu s exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 22) All property lines shall be clearly identified at thJme of foundation inspection. X 23) All building permits shall have a final inspection performed and approved by the Mason C(otialilding Department prior to permit expiration. The failure to request a fin i rhces or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County dand building regulations. X BLD2010-00487 Please referto the following pages for conditions of this permit. 4 of 6 24) All permits a ire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a er d not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have re nted action from being taken. No more than one extension may be granted. X 25) Pressure tr ood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors*N flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 26) Retaining Lled to support a surcharge suchh structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 27) By definition, propane tanks and heatpumps are stru res, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these struct��,7 eet the setback conditions listed. X 28) Landings an airs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Sit P n"to ensure these structures are shown and meet the setback conditions listed. X 29) Contractor reg ion laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0 . Th person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 30) Approved per n and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 31) The proposed p of t must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County S eline ter Program. X 32) Prior to fi I a proval, all upland areas disturbed or newly ated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 33) The applicant acknowleMthathis development was s(isuch that further shore protection measures will not be required for protection of the new structures. X 34) Temporary erosion co trot easures must be implemented to prevent water quality deg a�fif adjacent waters or wetlands. Silt fencing must be installed and maintaine ntil upland vegetation has become established. X 35) Mason County Utilities will need to be contacted to recieve the sewer control panel and p p core. Please contact Tom Moore at(360)427-9670 ext. 771 BLD2010-00487 Please referto the following pages for conditions of this permit. 5 of 6 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progr s inspection owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described propert a d struc re for eview and inspection. OWNER OR AGENT: DATE: BLD2010-00487 Please refer to the following pages for conditions of this permit. 6 of 6 MASON COUNTY PERMIT NO. r;5td 2010 - QVIM'' BUILDING PERMIT APPLICATION AILfy�-- L,6ja 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 ?)l_{0 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION n�v r nr _�tn t ILRAQ 7-t4o -' >00 Company Name AA A 1NC - ,.CNc1 AL(9JM� IDiZ Owner /�,-,.--v•-- - - Rib . Mailing Address 1 P1- , Mailing Address R6 . 3a 7 30 D1 Zip Code s City Irf� 1 City KFJ.t 1' State W State \IV — Zip Coded S Z Phone 253- '1- 200 Other Ph.2S3 -131l - 1�41 Phone 36a-ZIS-4D2i6 Other Ph.3.60-131-2602- Lien/Title Holder CLF►12 Contractor Reg. #faAC//J GC 1361DK Exp.a3- 2a11 E mail address E Mail Address Jo Hi-) LQ \/Ah4DlsAf4t9ME'5 -CO W� Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic t11 L�Q EGA ing Septic ��Z Connect to Water System ,X� Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No 122-1 95 COO o¢4 Fire District oJ Legal Description LA6 P---A"-10 �11 t,L� G'f" L-0 I - ��y� �� Site Address (Please include street name, street number and city) ( 5o W ESI 1-A-1')E DQ �i e tion�to sit U P 4I LL -f-D LAV)FL.A� V!l_LAr(,-E- O� nnDUIJTf�1�yt1=1cJ 1 -F-T O�V LAME ul Ei� FULL-O� �1412,J I- Q.1OLE R7�-L f)�J -ra 1 SD LZt 6-I�I Will timber be cut and sold in parcel preparation?Yes o Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New_X Add Alt Repair Other F`I^Qv RESIDENCE SEASONAL ❑ Use of Building 2ES1 p EN CI Describe Work COti7STei.1CT uJ�r �vt�t_(1 /'�6,t-- 47AO4 '0-E No. of Bedrooms --3 No. of Bathrooms 3 Square Footage- 1st Floor 1 S-7 1 2nd Floor 3rd Floor Basement 121 Z Deck 231 Covered Deck 12- Other Sq. ft. Garage ,393 Attached Detached —_Carport Attached Detached MANUFACTURED HOME INFORMATION - e Model Year Length Width Serial N No. of Bedrooms Na of Bathrooms Type of Heat urchase Price$ Replacement Unit? Yes/No Installer Name Certification No. CNVNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PR F OF NUATION QF WORK IS BY MEANS OF A PROGRESS INSPECTION. Date• A¢ ZO 1 D Owner/Owners Representative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date [Q- l L0-Z40 10 DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department E l-� EV i E. Public Works Department v bItC-- WInGrS Fire Marshal FEES Building Permit Fee Site Ins ection Plan Review Fee EH Review Fee Plumbing & Base Fee Plannin Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal MASON COUNTY PERMIT NO.6020 FFIQ-QQgl PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670-Belfair(360) 275-4467-Elma(360)482-5269 On the web www.co.mason.wa.us APPLICANT INFORM, TION CONTRACTOR INFORMATION Owner MA-LCOLNI f bAe_8 i2A 7140►tit ,ON Company Name AA r F:' IN C•G-EN EP_4-t- C otircACT(Je Mailing Address 2030o 131 Pt, 5a Mailina Address P.O• BOX 730 City KG-jjT State\^/A Zip Code 990 31 City.. ELi-A t 2- State �� Zip Code`f ,S Z 9 Phone 2 - 6Y) 201 D Other Ph.2S3-630-I LI Phone 31r."0' Z7 S-iCO& Other Ph: D Lien/Title Holder Ci-F=.4Q- Contractor Reg. # HAE f N GC 13&PKFxp eo 3 -2� E mail address E Mail Address`u D RAJ \/Ar tD1 3-I4,02WI.CS CD V-A Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System X Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No I ZZI 9 S CZ212o Fire District Legal Description L V'SE-LA-t-AQ L.07 Site Address (Please include street name, street number and city) 160 WEST LA E b(2 . b.LLY� klq Directions to site P f�l LL L>=P_T- Z?Ki MDU&3 IAI.ELj L>=� Oti �K f 0S T:OL DX AJ O C-�p t2.!(1-4T ON la1• LA U �L�.O� TD ISO Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New X Add—Alt—Repair Other Use of Building Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric. LPG_Natural Gas Heat Pump Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace I Bath Tubs Z. Heatpumps I Showers I Spot Vent Fan Water Heater I Propane Tank Clothes Washer I Gas Outlets t Kithen Sinks I Wood/Gas/Pellet Stove- Dishwasher I Kitchen Exhaust Hood I Hosebibs Z- Dryer Vent t Other � Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents teat the information provided is accur e and grants employees of Mason County access to the above described property and structure for review and hspec,�tion. PROOF OF C NU D D ATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. � x ate � 2 01 Owner!Owners Rep /Contractor ndicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Lf- I Lo-2.CZf(--)Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building De art ent p I Occ G rou N T e Constr.J Fl , Planning Department Environmental Health Department FEES Plumbing &Base Fee Site Inspection Mechanical& Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other P-- Name MALCQ M'tgQM CXJ Parcel# 1221 -e S -VOOO - BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE TIME STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in thheTirIfttirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the sysfem'will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the Stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described pro for review and inspection as may be required. Owner/Age(/Cont�ctor>cle one)Date: O Page of 2 Name 14DLM SOO Parcel# l 2ZI !q S�OOOL �- BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a Stormwater site plan is required whenever a building application is made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios, driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area * All dimensions in feet Buildings X 2 = l56 Zg X Z = I Measurements for buildings are taken at the perimeter of the farthest projections (example: X = eaves/gutters) X = Driveways g0 X X Length of drive begins at the right of way X = Parking Areas X ZZ S Any paved, gravel or packed area per definition X = above table X = Patios/Walks X = X _ Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/ VIAQ Compliance Application Owner: M,4(,60r_.M rt-pom5c"J Telephone:Zs3 � Parcel#: 22 S 6000 Type of project N New Residence ( ) Addition ( ) Remodel Total Sq. Ft. is Floor : 2 n6 floor: Heated Basement: of heated area:: 2943 1 I S3I 1 12- 7 2- Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace 0 Heat Pump with electric furnace O Heat pump with gas furnace O Boiler, specify fuel type: O Other: S ecif _ Glazing A Prescriptive Option see reverse side circle one: 1 11 IV Percentage: Compliance Method O Component Performance , Chapter 5— Calculation worksheets required Check one:: % O Systems analysis, Chapter 4 4 Whole House Ventilation system O Whole House Ventilation using a Heat Ventilation using exhaust fans&window or wall fresh air Recovery Ventilation System (VIAQ 303.4.4) System vents (VIAQ 303.4.1) Check one O Whole House Ventilation Integrated O Whole House Ventilation using an inline with a Forced Air System (VIAQ 303.4.2) supply fan. VIAQ 303.4.3) Window & Door Schedule (If needed, attach an additional sheet) Total Manufacturer Room/location U-Factor Size Quantity Square Feet Windows: AM LA Qo 0 25 3�X 3� I ID.S 8�0. Z 2 s 3°X s° 2- 30.o yylSt2 . gA-ril w 0. 25 Z� I I 4. 3-7 m� TE2 g� O.Z 5 8° x 4° 1 3Z .00 Li U lvi . 2S X S 2 lv)n� .2 ' Zt'x 2 � 3 /g .-7 �l �LN- 2S 59 X 3 6 1 I S � . 3 0 •2S 6° A4° Z4D F4M►LA 0 .25 6 KS° 1 SK`lu N-T S a.3D Z" X 29 3 12-0 Windows: Total Sq. ft. Ze;0. 1 Z Doors: AMU D I V1 1/1 11M o Zs 6� 0 40. 6 VVI I , d .2� 6 io g 1 4-0. 0 LaS . FQ`Q2- 0 -2S l tl x Sb Z. 10 . 0 Doors: Total Sq. Ft 00 Total window and door area Z Total window & door area 348. (Z/(divided by)total sq.ft of heated area 2843 = •13 %of glazing u 1 C PLANNING New Residence PLANNING: Water Power Line E ETBACKS ARE MEASURED - 190'-01, FROM THE FURTHEST - - - - JECTION OF THE BUILDING o - --- RECEWED AN -- --- --------------------- ' t MASON COUNTY ----------------- 44 w o J APPROVED Q co MASON COUNT DCD AN -- SITE PLAN REQUIRED TO BE ON SITE TE SUBJECT TO APPROVAL BY \, Date s = S s s s Line of Site DE516NFOR: 517EADORE55 � 50 Nest Lake Drive North Pane/# DATE: Jane[e--9, p �� ElTHOM50N, Malcolm & Barbara 122�9�000044 -. ,� _ ❑ 5CALE. 1 20