Loading...
HomeMy WebLinkAboutBLD2022-00604 SFR - BLD Inspections - 4/3/2024 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 SHELTON:360 427-9670, EXT 352 COMMUNITY SERVICES �- BELFAIR:360-275-4467,EXT 352 Building,Planning,Environmental llelth.CommunityH-111i ELMA:360-482-5269,EXT 352 -- www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bld-inspection.php Permit Number BLD2022-00604 Date Issued 08/04/2022 Issued By Project NEW SFR _ kin u Site Address 30 E Graham Rd Applicant BOWYER LAURA C&JOHN O -- -- Contractor ZIESER BUILT CONSTRUCTION INC Contractor Phone 1.360.271.3715 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED." PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks &,17-2Z PED Slab Footing Perimeter t i Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls AJA Other Rough-In Groundwork Plumbing Framing m ` Groundwork Mechanical Plumbing „2 Groundwork Gas Pipe Mechanical , 3 Gas Piping Shear Wall Nailing UnderfloorT a-z"01 *T Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls r 5 Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other t S,�b ►�t+re c:� u P MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Be lm ext.352 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBERZ\(A, $h'2-\' aQL ADDRESS/LOCATION:&) FINDINGS: V-( r Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. e corrections, items will be checked on the next inspection. ❑ OK to Date:__ -9 ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: a rr 6� "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 67 Belfair ext.352 0-275- �a COMMUNITY SERVICES 3 360-4822--5 69 Elma ext.352 Building,Planning, Environmental Health,Community Health • 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER'6\C�ZQ'LZ— Q(-) SCOL'1 ADDRESS/LOCATION:,2--)n �Vr�� I(Y� L6, FINDINGS: v V-PCA C') Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ell� Make corrections, items will be checked on the next inspection. ❑ OK to Date: ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: ()(-i( "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: RiD 0)0?.?-0060q ADDRESS/LOCATION: 36 E C4411AM ►Z b FINDINGS: DETECTOR f?EQ 0 R6'4) N VrAGE. o 6-- or^4^11 oc Aof — 1 SX ly IB'a Dty ?Erf'OMR)t accvPA y Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: a'{ ❑ Please contact our office regarding possible Department: l.D structural damage incurred by recent Inspector: Doi "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 r ' Mason County Mason County - Division of Community Development �r 615 W. Alder St. Bldg.8 t Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us B DD2022-00604 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: NEW SFR ISSUED: 08/04/2022 SITE ADDRESS: 30 E GRAHAM RD BELFAIR EXPIRES: 01/31/2023 PARCEL: 222125400903 APPLICANT: BOWYER LAURA C&JOHN 0 OWNER: BOWYER LAURA C&JOHN 0 114708 CONNELLY RD 114708 CONNELLY RD SNOHOMISH,WA98296 SNOHOMISH,WA98296 206.226.4903 GENERAL CONTRACTOR'S LICENSE: ZIESER BUILT CONSTRUCTION INC License: ZIESEBC077PR 7636 NW WILDCAT LAKE RD Expires: 09/30/2023 BREMERTON,WA98310 1.360.271.3715 VALUATIONS: FEES: Paid Due Covered Deck/Carport 257.00 $5,654.00 Planning Review Fee $240.00 $0.00 R-3 VB Residential, one- 2069.00 $306,894.77 Plumbing Fees $138.00 $0.00 and two-family Building Permit Fee $2,596.16 $0.00 U VB Utility, miscellaneous 536.00 $32,095.68 Technology Surcharge $95.45 $0.00 Mechanical Base Fee $30.00 $0.00 State Fee-Residential $6.50 $0.00 Plumbing Base Fee $25.00 $0.00 Mechanical Fees $296.00 $0.00 Plan Check Fee $1,687.50 $0.00 Building Plan Review/Change of $125.00 $0.00 Use-Onsite Sewage Total: $344,644.45 Totals : $5,239.61 $0.00 FIXTURES (fit Mechanical Fixtures Qt C Plumbing Fixtures 1,0000 Dryer Vent(s) 1.0000 Number of Clothes Washers 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers 1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks Printed by:Genie Mc(arland on:08/04/2022 02:33 PM Page 1 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 Sty Mechanical Fixtures Qtty Plumbing Fixtures 1.0000 Heat Pump(s) 1.0000 Number of Water Heaters and or Vent 1.0000 Propane Tank(s) 2.0000 Number of Showers 1.0000 Wood/Gas/Pellet Stove(s) 3.0000 Number of Hose Bibs 2.0000 Gas Outlet(s) (1-5) 3.0000 Number of Toilets 6.0000 Spot Vent Fan(s) 4.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Rough- Plumbing Inspection Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Inspection Insulation Inspection Underfloor Inspection Connection has been verified by Health or Utilities Shearwall Inspection BLD-Final Inspection Framing Inspection CONDITIONS • All property lines shall be clearly identified at the time of foundation inspection. " Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 2 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries(L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 3 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 . Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at(206)357-2620, ext. 630. * A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor),and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in or%sheets. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 4 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 y Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/d ra infield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 5 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 Adopted Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. Fuel Normalization Credits: Table406.2 2 Heat pump Table 406.3—Energy Credits (Single Family) 1.2 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.20 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present).Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.5 Air-source, centrally ducted heat pump with minimum HSPF of 11.0. 4 5.5 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 6 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 " Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. " OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. • All setbacks are measured from the furthest projection of the building. * The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report.All applicable recommendations and specifications shall be applied to the development on this site. Any deviation requires stamped written approval from the registered design professional responsible for the report and may require special inspection by the same. Structures and/or land modifications (grading, cuts, fills, etc.)required in the geotechnical report, may require a separate permit. The geotechnical report shall remain attached to the approved building plans. Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 7 of 8 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00604 " Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2018 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S2 designate wall(s)type 2, 3,AND 4 with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections,the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: \\A Contractor or Autho zed Agent: Date: ci29 Printed by:Genie Mcfarland on:08/04/2022 02:33 PM Page 8 of 8 r s.� � c ,.__.. _.... .....,.._.. ......�.._.._. ,.� .. : S til•♦ 1 i�lv'+i„Srwi, . p hi•L� ................ u/i�,SK+Ki rv. �._ __._ .............. _: ShecK if "'�o Uu TO-Ir id2o22 • �coo� For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for g climate zone 5 of ICC 400. Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits)and Table 406.3(energy credits)to achieve the following minimum number of credits.To claim this credit,the building permit drawings shall specify the option selected and the maximum tested building air leakage and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit:3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit:6 credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit:7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 11�k 4. Additions less than 500 square feet: 1.5 credits �5�c'� All other additions shall meet 1-3 above Before selecting your credits on this Summary table,review the details in Table 406.3(Single Family),on page 4. Summary of Table R406.2 Heating Credits-select ONE Options Fuel Normalization Descriptions heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 3 Electric resistance heat only-furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each p category 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 1.4 1 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC - 1.0 ❑ 3.31 High Efficiency HVAC 1.5 3.4 High Efficiency HVAC 1.5 ❑ 3.5 Hi h Efficiency HVAC 1.5 ❑ 3.61 High Efficiency HVAC 2.0 ❑ Prescriptive Path-Single Family 2018 Washington State Energy Code-R 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 5.6 Efficient Water Heating 2.5 ❑ 6.1° Renewable Electric Energy(3 credits max) 1.0 ❑ 7.1 Appliance Package 0.5 Total Credits a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)orC403.3.2(5) c. Equipment listed in Table C403.3.2(1)orC403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually,up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path—Single Family 2018 Washington State Energy Code-R s T241F905SP 24—INCH BUILT—IN FREEZER COLUalVIN WITH Thermador INTERNAL ICE MAKER FREEDOM® COLLECTION, PANEL-READY PROPERTIESGENERAL Home Connect®(Wi-Fi Enabled) Yes Panel Ready Yes I Reversible Door Swing Yes SoftClose®Door Yes j` SoftClose®Drawers Yes Lighting LED Sidewall and Theater Lighting Freezer Shelves 4 I Adjustable Shelves 3 Shelf Material Glass w/Aluminum Profile " ° f Full Extension Drawers @ 115°Door Opening Yes Angle r Y if�lt General Use Drawer 2 Door Bins 4 External LED Proximity Sensor No Oversized Dispenser Opening No _ Chilled Water,Crushed and Cubed Ice No Rapid Water Replenishment System No Ice Maker with Diamond Ice System Yes Door Open Alarm Yes 0 Home connect �K< s�a Open Door Assist Yes vv C us N Special Modes Sabbath,Economy, Vacation FEATURES & BENEFITS CAPACITY Full Stainless Steel Inner Liner Total Capacity(cu.ft.) 12.2 cu.ft. Freedom®Hinge enables true flush design PERFORMANCE Auto Door Opening provides the opening of the door with just Dedicated Evaporator&Compressor System Yes a slight push or pull SuperFreeze® Yes Energy Efficient Diamond Ice made with twist tray technology Defrost Process Frost-Free Smooth Filtered Lighting for clear and easy viewing of all TECHNICAL DETAILS product Watts(W) 350 W SoftClose®Drawers for easy and controlled storage Sleek clean design for the perfect symmetry when paired with Current(A) 15 A additional columns Volts M 110-120 V TFT control panel managing all your columns functions Frequency(Hz) 60 Hz Power Cord Length(in.) 118 TEMPERATURE RANGES Plug Type 120V 3 Prong Freezer -11°F(-24°C)to 7°F DIMENSIONS (-1VC) i. Appliance Dimensions(H x W x D)(in.) 84" x 23 3/4"x 24" SuperFreeze® -22°F(-30°C)for Required Cutout Size(H x W x D)(in.) 84"x 24"x 25" approximately 52 hours ---- --- — Net/Gross Weight(Ibs) 327/349 Ibs Energy Saving(Economy)Mode 3°F(-16°C) EFFICIENCY ENERGY STAR®Certified Yes Annual Energy Consumption 435 kWh 'Height adjustable+/-1/2•(+/-13 mm) Page 1 of 3 3/23 T241 F9055 P 24-INCH BUILT-IN FREEZER COLUMN WITH Thermader INTERNAL ICE MAKER FREEDOM@ COLLECTION, PANEL-READY WARRANTY Limited,Entire Appliance,Parts and Labor on Any Part of the Refrigerator that Fails Because of a Manufacturing Defect 2 Year Limited Warranty for Sealed Refrigeration System*;Parts and Labor 3rd to 6th Year Limited Warranty for Sealed Refrigeration System*;Parts Only 7th to 12th Year Limited Warranty for Stainless Steel Rust-Through Lifetime *Sealed refrigeration system includes compressor,evaporator,condenser,dryer/strainer and connection tubing CUTOUT DIMENSIONS 24" (610 mm) Furniture return A: Area for installation of power connection. B:Area for running the water line. It is recommended that the waterbox is placed adjacent to the installation cavity, so that it can be accessed for service without uninstalling the appliance. If this is not possible, place the recessed waterbox adjacent to the water supply socket elevated at the heights as referenced in areas A and B. 84"-851/1s"; C C: Niche depth depends on kitchen design. For a flush (2134 mm-; installation, the depth needs to be at least 24 inches plus 2164 mm) the thickness of the door panel. Stainless steel models contain a panel-ready base unit, AIR ; ready-to-install stainless steel door(s)with a right or left 00 door swing and handle(s). B� — rr min. 4"� 4 (102 mm) (102 mm) `:B. TOP VIEW CLEARANCE I.-24" (610 mm) *" Door handle must be added 1 to this dimension 113/4,,** 24" (299 mm) 1 1 (610 mm) /8 /s (3 mm) (3 mm) * Depends on the thickness of the furniture door. 3/4" (19 mm) is relevant for the 233/4" —� stainless steel door. (special Accessory). (603 mm) 115° 7 2611/16" O (677 mm) 3/4" (19 mm)* 90° i Page 2 of 3 3/23 T241F905SP Thermadar 24-INCH BUILT-IN FREEZER COLUMN WITH INTERNAL ICE MAKER FREEDOM® COLLECTION, PANEL-READY PRODUCT AND PANEL DIMENSIONS 233/4" 233 " 24" (60I�3 mm) m I (603 mm) (610 mm) 84" 797/8" (2029 mm) (2134 mm) 797/8" (2029 mm) 71/8" (181 mm) variable:water- . . ... .................................... connection at 213/16"-43/16" the appliance (72-106 mm) 233/4" 4" e(� 30 mm) (102 mm)±J 24" (610 mm 4" (102 mm) t ACCESSORIES . • FLAT STAINLESS STEEL DOOR PANELS HANDLES 24-Inch Flat Stainless Steel Door Panel Without Dispenser Choose between two options: in TFL241R800 For use with Handle PR36HNDL20 j TFL241R905 36-Inch Professional Series Handle Heater Kit Required Handleless HEATRKIT20 — 13W @ 120V or Freedom®Heater Kit STORAGE When two appliances are installed __........_..,, MS36HNDL20 side-by-side a sealing kit must ICEBUCKETL be used.For combinations 36-Inch Masterpiece®Series Handle that involve a freezer column, Large Ice Bucket this sealing kit is included.For all other(non-traditional,i.e. two wine columns,two bottom F RA M E K I T 10 FILTERS freezers,etc.)side-by-side combinations or instances where Freedom®Frame Kit For any custom column installation in 24-inch REPLFLTR55 any appliances are installed less Freedom®Water Filter than 6-inches(152 mm)apart from deep cutouts.With two metal side trims whose placement between the interior cutout wall and Replacement water filter for one another but not connected the appliance helps overcome the challenge of use in all freezer and bottom side-by-side,purchase this kit. unfinished cabinet returns. freezer models This kit is recommended for use with any installation in areas that are subject to humidity,or located next to an outside wall. These warranties give you specific legal rights and you may have other rights that vary from state to state.Limited warranty from date of delivery.For complete warranty details,refer to your Use &Care manual,or ask your dealer. Specifications are for planning purposes only.Refer to installation instructions and consult your countertop supplier prior to making counter opening.Consult with a heating and ventilation engineer for your specific ventilation requirements.For the most detailed information,refer to installation instructions accompanying product or write to Thermador indicating the model number.Specifications are correct at time of printing.Thermador reserves the right to change product specifications or design without notice.Some models are certified for use in Canada. Thermador is not responsible for products that are transported from the U.S.for use in Canada. 1 800 735 4328 1 USA THERMADOR.COM I CANADA THERMADOR.CA 1 02023 BSH HOME APPLIANCES CORPORATION.ALL RIGHTS RESERVED. 3/23 Page 3 of 3 t, 24" Custom Panel Dishwasher C44) BoscH 800 Series DLX — Custom Panel SHV878ZD3N Invented for life General Properties Details Number of wash cycles 6 Watts (W) 1440 W Number of options 6 Current (A) 12 Amps dBA 42 Volts (V) 120 V Third rack Flexible 3rd Rack Frequency (Hz) 60 Hz Rack adjustability Rackmatic@ Power cord length 67" Tub material Stainless Steel Install length from 45" _ corner of unit - Control type Touch Control Minimum water pressure 14 Concealed water Yes (lb/sin) SHV878ZD3N heating element Custom Panel - - -- - Length outlet hose (in) 79" Leak protection system 24/7 AquaStop® Dimensions&Weight Patented CrystalDry'" Water softener No ___ Overall appliance 33 7/8" x 23 9/16" technology transforms Five-level wash Yes dimensions (HxWxD) x 23 1/16" moisture into heat to get (in) ChildLock No dishes, including plastics, — — -- Required cutout size 33 7/8" x 23 5/8" Special features InfoLight®, (HxWxD) (in) x 24" 60% drier.* CrystalDryTM Option - Adjustable feet Yes Features&Benefits Efficiency Net weight (Ibs) 99 Ibs 42 dBA: dishwasher runs Water usage per cycle 3.5 quietly so your kitchen conversations aren't Energy efficiency class Tier 1 Junction Box SMZPCJBIUC interrupted. ENERGY STAR®qualified Yes - Bosch Dishwasher Water SMZSH002UC The Flexible 3rd Rack Total annual energy 269 Supply Hose with fold down sides adds consumption (kWh) 30% more" loading area, Drain Hose Extension Kit SGZ1010UC perfect for utensils and Total annual water 623.5 consumption (g) Dishwasher Accessory SMZ5000 ramekins. Kit Touch Control Technology Capacity Anti-Tarnish Silverware SMZ5002UC allows for quick cycle Number of place settings 16 Cassette programming. _ The AquaStop° leak Edge Protector SIVI POOlUC protection system contains Stainless Steel Straight SMZ1007UC leaks through a precisely Bosch Bar Handle engineered system. If a leak occurs, the system -- contains it by shutting down operation and pumping out water. So you have the ultimate peace of mind whether you are away or at home. *Based on aggregate average drying performance of Bosch Dishwashers with CrystalDry on combined household - load including plastics,glass,steel,and porcelain as compared to Bosch Dishwashers with PureDry.Drying performance may vary by dish type. - - - -Compared to a Bosch dishwasher with 2 racks. Accessories:To purchase Bosch accessories,cleaners&parts please visit www.bosch-home.com/us/store or call 1-800-944-2904(Mon to Fri 5 am to 6 pm PST,Sat 6 am to 3 pm PST). Notes:All height,width and depth dimensions are shown in inches.BSH reserves the absolute and unrestricted right to change product materials and specifications,at any time,without notice.Consult the product's installation instructions for final dimensional data and other details prior to making cutout. Warranties:Please see Use&Care manual or Bosch website for statement of limited warranty. For more information on our entire line of products,go to www.bosch-home.com/us or call 1-800-944.2904 0 BSH Home Appliances Corporation.All rights reserved.Bosch is a registered trademark of Robert Bosch GmbH. OS/19 24" Custom Panel Dishwasher BOSCH 800 Series DLX — Custom Panel SHV878ZD3N Invented for life Installation Details Included: (600-616) �•' Pre-connected 231/16" 239/16" drain hose (585) (598)� 24" I� (610)ill min.337/8"; Toe-kick 337/a"-35" (min.860) (860-890) '271/2"-301/8"' Power cord •(700-765) i "231/8= (3-prong plug) 233/8" ''(588-594) (16-22) 31/2"(89) 35/e"-71/2" I,r 21/8"(53) (92-190) 4"(100) (A) A:Front view *measured from the bottom edge of the countertop panel thickness 67"(1750)(B) 63"(1600)(B) B:Drain hose recommended 3/4"(20 mm). C:Electrical Power Cord: This dishwasher can accept custom door panel weights ranging 45"(1140)(C) 4 45"(1140)(C) length shown according to Installation Instructions from 7 to 24 lbs;however,the dishwasher comes from the factory D:Inlet ready for custom panel door weights from 11 to 18 lbs. E:Drain If you plan on using a door panel that is not 11 to 18 lbs. (D): (E) (F) F: Electrical please contact customer service at(800)944-2904. **24"(610 mm)wide panel may be used All connections are at the rear of the appliance. Extension for drain hose available as accessory. depending on cabinet design Junction Box for hard wired connection Note: Refer to installation template for mounting hardware locations available as an accessory. measurements in inches(mm) measurements in inches(mm) 0 21/2" 0 2 1/2" (63.5 mm) (63.5 mm) 7„ 7" 0 (178 mm) (178 mm) (63.5 mm) (63.5 mm) Note:Cutout Note:Cutoutct� required on left or right 3-prong required on left or right Junction box accessory cabinet wall,depending on power cord cabinet wall,depending on AMavailable for purchase location of water inlet,drain included location of water inlet,drain SMZPCJBI lJC and electrical connection and electrical connection (not included) Example of Hardwire Installation Example of an Electrical Receptacle Installation Accessories:To purchase Bosch accessories,cleaners&parts please visit www.bosch-home.com/us/store or call 1-800-944-2904(Mon to Fri 5 am to 6 pm PST,Sat 6 am to 3 pm PST). Notes:All height,width and depth dimensions are shown in inches.BSH reserves the absolute and unrestricted right to change product materials and specifications,at any time,without notice.Consult the product's installation instructions for final dimensional data and other details prior to making cutout. Warranties:Please see Use&Care manual or Bosch website for statement of limited warranty. For more information on our entire line of products,go to www.bosch-home.com/us or call 1.800-944-2904 05/19 0 BSH Home Appliances Corporation.All rights reserved.Bosch is a registered trademark of Robert Bosch GmbH. 24" Custom Panel Dishwasher 800 Series DLX — Custom Panel SHV878ZD3N C44) BOSCHInvented for life Installation Details Non-metallic tie Non-metallic 6e Note:Plumbing installations will vary-refer to local codes. Drain hose included is 79" (201 cm)and can be extended / to a maximum of 155 3/4' (396 cm). Always use the approved drain hose extension kit E ,- �� E (SGZ1010UC). C Remove o C plug Ensure a portion of the drain hose is raised between min. x 33" (84 cm)and max.43"(110 cm) above the cabinet floor. E E )= E IJ Accessories:To purchase Bosch accessories,cleaners&parts please visit www.bosch-home.com/us/store or call 1-800-944-2904(Mon to Fri 5 am to 6 pm PST,Sat 6 am to 3 pm PST). Notes:All height,width and depth dimensions are shown in inches.BSH reserves the absolute and unrestricted right to change product materials and specifications,at any time,without notice.Consult the product's installation instructions for final dimensional data and other details prior to making cutout. Warranties:Please see Use&Care manual or Bosch website for statement of limited warranty. For more information on our entire line of products,go to www.bosch-home.com/us or call 1.800-944-2904 ©BSH Home Appliances Corporation.All rights reserved.Bosch is a registered trademark of Robert Bosch GmbH. 05/19 Electrolux Front Load Perfect StearoTM Electric Dryer with Balanced DryTM and Instant Refresh—8.0 Cu.Ft. Dryer Available Products:ELFE7637AT,ELFE7637AW Available Colors:Titanium,White Version:02/23 Product t Dryer Dryer Cycles Air Flow ni Balanced Dry Yes Yee Dram Back Ten=r Painted Sti ei Yes Dnun Iyfateri. Stainless Steel Yes Dryness Levi., glom Yes Yes Lint Filter Yes Fast Diti' Yes _ W Heaal Duty_� Yes In stant Refresh �- Yes Dryer Options Mixed Load .14u stoic Yes Normal Delay Start Time 1-12 Hours Timed Dry Time Yes Drum Li t _ Yes Towels Div Boost Yes Extended Thmble Yes Drying Temperatures Peifect Steam Yes Low Yes Wrinkle Release Yes Normal Yes Yes Dryness Level sanitize _Yes hlax Yes Ies Norma( Yes Controls Low Yes Ca»cel Yes Damp Yes Cycle Status Lights Yes Delay Start Yes Exterior Estimated Time Remaining Yes Door l..:atch Yes Conuol Lock Yes Reversible Door Yes Pause Function Yes Power On/Off. Yes Electrical Specifications Minimum Circuit Rt ulrcd..... 31)Am s Volute Rating 2081240v Dimensions and Volume Height_ 3g" Installation Width 27" O pnonal Pedestal Yez Depth 32" _ Dryer 1)i n c opacity� 8 Cu.Ft. Performance Certifications and Approvals ENERGY STAR Certified Energy Data __ _........_ _.____ Comhfned Enet •Factor C.EF 3.48 kwlvcy'cle 2.5 kWh kWh/year 620 kWh rightWe reserve the 1' I or discontinuemodels • YI ElectroluxI Appliances, 10200 1 , 1 itt I Front Load Perfect SteamTM Electric Dryer with Balanced DryTM and Instant Refresh—8.0 Cu.Ft. Dryer Available Products:ELFE7637AT,ELFE7637AW Available Colors:Titanium,White Version:02/23 General Specifications Chime Chi/Chime Off Yes 1,eveling Legs yvs Prop GS f.,ahel No Warranty-L.ahor 1 Year Warranty-Pans 1 Year Safety Certifications and Approvals UL Listed Yes We reserve the right to change specifications or discontinue models notice. Front Load Perfect SteaMTm Electric Dryer with Balanced Dryer Dry rm and Instant Refresh—8.0 Available Products:ELFE7637AT,ELFE7637AW Available Colors:Titanium,White Version:02/23 Installation Diagram Front Left 53 /8" 31 2" 38" Optional Rear 15" Pedestal Drawer 27 Front 15" We reserve the right to change specifications or discontinue models without notice. Electrolux Major Appliances,N.A. Side 15'/4" Installation*for Electrolux Front Load Dryer TO INSTALLER: Leave these instructions with the customer. ® Electrolux "Please refer to the Use&Care Guide provided with this dryer for further details. "DO NOT exceed 8 It.(2.41)total duct length If 1 ing semi-ngid venong. 4 Le Vel and connect AN DO NOT install flexible plastic a flexible foil ducting material. WARN I NG - RISK OF FIRE DO NOT use screws,rivets or other fasteners that extend bro the duct to assemble the exhaust Use adjustable pliers to adjust the leveling legs so the washer e system. is level front-to-rear and side-to-side,and stable corner-to- Read all the following instructons before instaling and using this appliance. For detailed Information,refer to"Exhaust system requirements"and LIJ cercer •Ensure the entire dryer exhaust system is clean and free of lint and debris prior to "Clearance requirements'in the Installation sections of the Use&Care Guide 2.Comect power. the installation of your new dryer.The entire exhaust system should be inspected provided with this dryer. and cleaned a minimum of every 1a months with normal usage.Failure to comply with cleaning your exhaust system will increase the RISK of FIRE- DO NOT install a clothes dyer with flexible plastic or flexible foil venting material.Flexible venting materials are known to collapse,be easily crushed and trap lint.These conditions will obstrl clothes drverarnow and increase the risk Offire. 2 Connect Water Line(Steam Dryer Only) •DO NOT screen the exhaust ands of the vent system,or use any screws,rivets a other fas- teners that extend into the duct to assemble the exhaust system.NO screen or grate of any if this is not a steam dryer,skip to section 3. IMPORTANT mesh size is allowed to cover the outdoor exhaust opening. 1. Inspect all hoses for rubber washers prior to use. •Install the clothes dryer according to the manufacturer's instructions and local codes. 2. Fun water from cold outlet to d nt clear contaminas. Short Hose •Clothes 3. Conn dryer installation and service must be performed by a qualified installer,service ages- ed the dryer Assembly Hose Kn hose � Please review the"Trouaashootng"section in your Use&Care Guide before calving for service. cy or gas supplier. extensions from the cod supply to the•Y• 'Y"Connector For detailed information refer to the Installation sections of the Use&Care .The electrical service to the dryer must conform with local codes and ordinances and the Connector,than from the'r connector to the Water Inlet Guide provided with this dryer. latest edition of the National Electrical Code,ANSI/NFPA 70,or in Canada,the Canadian water rxlel on the dryer. on Dryer Electrical Code CSA C22.1 part 1. 4. Attach the washer cold water supply line to the •The gas service to the dryer must conform with local codes and ordinances and the latest "Y'connector edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54,or in Canada,the Natural Gas and Propane Installation Code,CSA 6149.1.An individual manual shutoff valve must be in- 5. Tighten all connections by hand,than tighten 512 Installation Checklist stalled within 6 ft.(1.83 m)of the dryer in accordance with the National Fuel Gas Code.ANSI additional 2/3 turn with Pliers. o' Z223.1/NFPA 54. 6. Turn m water and check for leaks. Cold Water Supply 0®®@ Exhaust Venting 240v Electric Supply •DO NOT stack a dryer on top of washer already installed on pedestal.DO NOT stack washer Assembly Hose Kit P/N 5304495002 is not included Hose to Washer "'� j (Electric Dryer) on top of dryer.DO NOT stack washer on top of another washer. with purchase of strum model and MUST be `wO O Frse-ibvnng,dear of lint buildup 0 Approved NEMA 10-30 or 14-30 service •The dryer is designed under ANSI Z21.5.1/CSA 7.1 or UL 2158-CAN/CSA 022.2 No.112 purchased separately. Cl 4 inch(102 mm)rigid metal a (latest editions)for HOME USE only.This dryer is poll recommended for commercial applica- For detailed Information,refer to"Water connection(Steam Model only)"in the semi-ngid metal transition ducting cad with all screws fight on terminal block tions such as reslaurshis,beauty salons,etc. Installation sections of the Use&Care Guide provided with this dryer. of minimal length and turns O Approved strain relief installed •Destroy the carton and plastic bags after the dryer is unpacked.Chidren might use them to O NO foil or plastic venting material O Term l access cover installed before play.Cartons covered with rugs,bedspreads,or plastic sheets can become airtight chambers O Approved vent hood exhausted to outdoors initial operation causing suffocation.Place all materials n a garbage container or make materials inaccessible poor Reversal detailed instructions in this guide to children. Leveling •To reduce the risk of severe injury or death,follow all installation instructions in this manual. O Dryer is level,side-to-side and hart-to-back O Follow The instructions in this manual and all other literature ncluded with this dryer are not meant to Connect to Gas or Electric ❑Cabinet Is sitting solid on all comers O Test hinge and latch for function cover every possible condition and situation that may occur.Good safe practice and caution Electi Der Gas supply( Dryer) Electrical Power MUST be applied when installing,operating and maintaining any appliance. Gas Dryer p House power turned on 1. Apply approved thread sealant. I O Manual shutoff valve present In supply LS o 2. Wrench-tighten gas line. �00 �9l) ❑Al corxnections sealed with approved sealer ❑Dryer pugged in 3.Open gas valve and check for leaks with a 1 „„x- � and wrench tight Final Checks 1 ❑Conversion kit for LP GAS system O Door latches and drum tumbles when soapy water. Connect or Construct Vent Exhaust ' O Gas suoply turned on cycle starts NH•wi'" O No leaks present at all connections-Check O Registration card sent n "� co screen or grate of any �'"". I ::: �� IX with soapy water.NEVER check with flame \�IL�I mesh size is allowed to P I EEDcover the exhaust opening. i �re._, Water Hookup(Select Models) ewe. O Inspect hoses for Proper Placement of i �e robber washers Exhaust system rate be yarded outside with approved vent hood. I O Water supply is turned on • Use only 4 inch rigid or • Use 4'(10.2 cm)damp to ►Close O Check for leaks semi-rigid metal ducting. connect dryer&exhaust wumr Manual Shutoff • Clean lint from duct system. system. I O Steam navel dryers IT#5ve use of • Use only metal foil tape to • Use 901 quick-tum elbow to ASSEMBLY HOSE KIT bep purchased 2 connect ducts(no screws) vent left a right from dryer. � For detailed information, an to For detailed system separately land must be purchased "Gas supply requirements"and "Electrical system requirements" separately K125ft. AXIMUM LQJGTH' "Gas connection"in the Installation and"Electrical installation"in the of 4'(10.2 pit)Rigid Metal wd sections of the Use&Care Guide Installation sections of the Use&Care Correct provided with this dryer. Guide provided with this dryer. VENT HOOD TYPE neco i WARNING EM •Dryer must be properly grounded at all times.larveredg .5'(6.35 cm) LP systems MUST use conversion kit installed by qualified tocMidan,ktxfxolla gas imtalW-m 0 tt. .5 m tint or LP conversion coud result in injury a even death. 35 m 0 ft. .5 m 2m 0ft. 7.5In SAVE THESE INSTRUCTIONS FOR FUTURE REFEREN . m 0 ft. 4.5 m(26 m) o ft.(21.5 m Inoornct For support in the US.call 1-877-4ELECTROLUX( -877-435-3287)or visit WWW-e(ectroluxappIiances.com.For support in n Caada call 1-600-265-8352 or visit www.electroluxappliances.ca. 1 A17468301(1907) Electrolux Front Load Perfect SteamTM Washer with LuxCare®Plus Wash and SmartBoost©-4.5 Cu.Ft. Front Load Washer Available Products:ELFW7637AT,ELFW7637AW Available Colors:Titanium,White Version:07/22 Product S1 1 Washer Washer Cycles Drum Light Yes Drum Material Steel Color_ Yes Maaimmn Spin Sp,,- Cycle t Lout Water kleater Delicates Yes Water Level Adjusttnenc Yes Fast Wash Yes Hand Wash __ Yes Washer Options Normal - l es -- _ Extra Rinse Yes Rinse and Spin Yes Steam Yes Acuvewear Yes Stain Soak lLs Heavy Duty Yes Extended Refresh Yes Optic Whites Yes Delay Start Time 1 12 Hours Towels Yes Pure Rinse Yes Allergen __--yes - — _ Soil Levels Perfect Steam Yes Extra Light Yes Light Yes Temperature Settings Normal Yes Cool Yes Heaw -- Yes Wane Yes--- --— -- Solid Soil Yes Hoc Yes samti�e Yes Washer Spin Speeds Eco Cold Yes Spiu Speed Selections 5 Max Yes Controls ili n.. — . .— Yes Cancel Yes Medium It Status Ltdhts Yes I o" Yes Delay Staff Yes No Spin Control Lock Yes Pause 1'mictirm Yes Dispenser Power OlvOfl Yes Bleach Dispenser Yes Start Yes Detergent Dispenser Yes Prewash Detergent Dispenser Yes Exterior Fabric Softener Dispenser Yee Door Latch Yes PODS Dispenser Yes Reversible Door Yci Dimensions and Volume Electrical Specifications Minimum Circuit Ret�uired 15 Amps , — Width Volta eRatin�-- 12pV De,th Washer Drum C:al�acity L Installation Opr- _ Yes_ Sul — Yes We reserve the right to change specifications or discontinue models without notice. Electrolux USA-10200 David Taylor Drive-Charlotte,NC 28262 .11 *Front Load Perfect SteamTm Washer with LuxCare®Plus Front Load Washer Wash and SmartBoost®-4.5 Cu.Ft. Available Products:ELFW7637AT,ELFW7637AW Available Colors:Titanium,White Version:07/22 Performance Certifications and Approvals Energy Data C:EE Tier Tier 2 Integrated Water Factor 3.2 ENERGY STAR Certified Yes kWh/vear 85 kWh ENERGYSTAR Most Efficient Yes Modified Ene1y Factor 2.92 High Efficiency Yes Water Usage/Year 4,248 Gallons kWlUcpcle 0.29 kWh General Specifications Chime On,:(Jurne Off Yes Leveling Legs Yes Prop 65 Label No Warranty-Labor 1 Year \-varrann-P,irts 1 Year Safety Certifications and Approvals SSl Ler[iticd Yes tianitization and Allergy Reduction J------ --Yes — --- specificationsWe reserve the right to change inue models withoutnotice. Electrolux Major Appliances,N.A. 10200 D. • Charlotte, , CANADA • •• 511 Front Load Perfect SteamTM Washer with LuxCare®Plus Front Load Washer Wash and SmartBoost®-4.5 Cu.Ft. Available Products:ELFW7637AT,ELFW7637AW Available Colors:Titanium,White Version:07/22 InstaHation Diagram Front Left 27„� 32„ 53'12" 38" Optional Rear 15" Pedestal Drawer 7'1_2-' 7 � � .• 27" ..1 3" 2,/2„ -� M 3 ° Front 35'/2" i 35" 32'/2" �..--- 26'/2 Side 15 Y4 We reserve the right to change specifications or discontinue niodels without notice. Electrolux Major Appliances,MAL ii David Taylor Drive-Charlotte,NC 28262-Charlotte,NC 28262-1-877-4electrolux(1-877-435-3287) efectrolux.com/en :i: ® Electrolux Installation*for Electrolux Front Load Washer TO INSTALLER: Leave these instructions with the customer. 'Please refer to the Use&Care Guide provided with this washer for further details. WARN' d tuba a standpipe and Connect Drain and Electric -`�-----� / 1 Verity the anti-siphon disc is n place. Form a"U"shape on the r ...� 2. hose,Place the top formed hire m the to enclosure Package)to d seed toward the nnu-slonvn AN d of the dram those with the hose pointed a� ed RISK OF FIRE nit anti ry secure the drain /. �r ..� O e SlandPipe•blot O f f O . hose does net Pull out from the force of the water. Read all the following instructions before installing and using this appliance. ♦ 3 Plug the power cord into a grounded outlet. Dispose of the carton and plastic bags after the washer is unpacked,Children might use �� xt 4. Turn on the power at a circuit breaker/fuse box. them for play.Cartons covered with rugs,bedspreads,or plastic sheets can become airtight 5. Carefully slide the washer chambers causing suffocation.place all materials in a garbage container or make these materials to its final position.Recheck Iri Lm Q NOTE nocoessible to children. leveling and rock corners for Thane s .For your safety the information n this manual must be followed to minimize the risk of fire or For detailed information,refer provided with washer" the Installation (215an) The starWpipe rissole diameter explosion or to prevent property damage.personal injury or loss of fife.Do not store or use sections of the Use 8 Care Guide provided with this washer. stability..Re ove and the must be 1-1/4•(3.2 cm) washer.Remove and discard minimum.There must be an air gasoline a odrer fieru eble vapors and squids in the vicinity of this or any other appliance. w door tape. Install Me washer accordng to the manufacturer's instructions and Local codes. 1 Electrical Requirements } gap around the dram gross n 6. Run the washer through a / the standippe.A srutg hose 1a •The electrical service to the washer must conform wait local nodes and ordinances and the latest complete cycle,checking can cause a spheral action. edition of the Nationale Code,PNSVNFPA 70,or in Canada,the Canadian Electrical Code CIRCUIT-Individual,property polarized and 1. The washer MUST be grounded.In the event for v star leaks and proper caws T. CSA C22.t part 1. grounded 15 amp.branch circuit fused with 15 of malfunction or breakdown,grounding will operation. I I IMPORTANT •To audit back or other injury,have more Man one Person move a lilt the washer. amp.time of fuse«circuit breaker. retluce the risk of electrical shock by a path a least resistance for electrical current. 7. fi you have any questions l •Do not stack a dryer on top of washer already installed on pedestal.Do not stack washer on top POWER SUPPLY-2 wire,with ground,120 volt 2. Since your washer is equipped with a power during initial operation.please Check to ensure the power of dryer.Do not stack washer on top of another washer. single phase.60 Hz,Alternating Current. supply cord having an equipment-grounding review the"Troubleshoothg' ® is off at a circuit breaker/ rounded conductor and a grounding plug,the plug section n the Use&Care tune box before plugging the The instructions n the manual and all other Real included wait this washer are net meant to OUTLET RECEPTACLE-Properly g Guide before calling for power cord irto an outlet. cover every possible condition and situation that may occur.Good safe practice and call MUST 3-prong receptacle to be located so the power MUST ce plugged into an appropriate.copper service be applied when installing,op,rating and maintaining any appliance. guppy cord is accessible when the washer is in wired receptacle that is property installed and an installed position. grounded n accordance with all bcal codes For detailed information,refer to"Connecting drain and electrical'in the and ordinances or in the absence of local Installation sections of the Use&Care Guide provided with this washer. 1 Remove Foam Packaging and Shipping Hardware ANSV with the National Electricalor Codes, Q WARNING the Canadian 70l latest l code),a.1 Canada, tlne Canadian electrical code C22.1 pert 1. Remove Foam Packaging ELECTRICAL SHOCK HAZARD Ifin doubt,call a licensed electrician.DO on Temporariy remove door tape. © Improper connecton of the eWipment grounding NOT cut off or peer the grounding prong re 2. open washer door and remove e.�erything WARNING conductor can reuse an electrical shock that Me power supply cob.In situations where a may twe-skitr�ptacleis present,aismeowne`s 6 InstallationChecklist from the drum. ELECTRIC SHOCK HAZARD responsibility to have a licensed electrician 3. Close door and reapply door tape. Certain internal parts are memorially not a Licensed electrician A you are in doubt as to replace a with a properly grounded three Shipping Hardware Drain 4. Using a rug. grounded and maY present a risk of electrical whether the appliance is property landed prong grounding type receptacle. ❑ Foam sMPPin9 support(under wash tub) ❑ Stand Pipe or wall drain t>eght mninxun 24' blanket or piece of shock tt contacted c ur'vg installation. removed and stored ❑ Verity anti-siphon discs attached toward end cardboard to protect Do not contact the following parts while the For detailed information,refer to-Electrical system requirements'in the the Aber.carefully appliance is energized Installation sections of the Use&Care Guide provided with this washer. ❑ Shipping bolts and spacers removed from of drain hose Lay the washer on as rear of appliance and stored ❑ Drain hose secured inplace with bac" Pump.Dave man. Leveling the Washer ❑ Hole plugs(shipped in bag indrum)imtaled cable tie(shipped in drum) 5. Remove Styrofoam Electrical Control boards in holes n backsheet Door Reversal base and Excessive noise and vibration can be prevented legs)se the washe,sus solids m tits flrxx or sapping 'Water vaM� by PropeN leveling the washer. ALL four legs.Keep the leveling leg extension at Leveling ❑ Follow detailed instructions in plug and 1. Place a level be top of the washer. a minimum for best performance of the washer. ❑ washer is level,side-to-skle and Iron) - Tethist guide set Man" Q CAUTION 2. use an adjustable wrench to adjust the d cec4c ❑ rest hinge and latch for function aside. lav ing Legs so the washer is level ham-to-rear ❑ Cabinet is eating slid an all comers Electrical Power 6. Carefully EXCESSIVE WEIGHT HAZARD and side-to-side,and stable comer-to-corner. Water Supply ❑ House Power fumed ern ream the To avoid back or other niury,have more than n / washer one person move or let the washer. 3. Press Were he alternate comers and sides Cl Use only new hoses and verily rubber sealing ❑ Washer plugged in 1C� and feel for the slightest movement Adjust the washes are Installed uprght fltwl Chocks IMPORTANT For detailed information,to to'Lavaling the washer"in the Installation ❑ HOT supply is connected to HOT inlet and ❑ Installation nstM ors and Use&Care Glide position. sections of the Use&Care Guide provided with this washer. COLD supply is connected to COLD inlet 7. Carefully move the washer to within 4 feet DO NOT tip washer upside down onto its top« ❑ HOT and COLD water guppy Doreador thoroughly It m)of its final location. onto its right side for any reason. ❑ p Door and water enters drum when cyc e 4 Connect Water Line tuna on starts ❑ No leaks Present at water supply connections ❑ Registration card sent in1. Run some water from the hot and cold faucets guppy and the COLD or appliance inlet connections-recheck in Remove Shipping Bolts and Install Plugs 10 flush the water lines and remove particles irA hose to the COLD 24 hours i. Ferrel shipping bolls from rear of unit. 2. Sauer les boudril darn Is Petit sac toumi that might cog the wale valve screens and water supply .. vec leis hustles d'istnlctiors de Is Lai that determine which faucet is ha and which is 5. TxJrten by hand Q NOTE 3. Les insdren dance les trous clans to poll cold supply. until snug.Then arrom de Is lavefse 00 Is quwncaYlerie de trans- each supply need time to relax before 1gneY can port avart Ste retime. 2- Check ro cretins Mat the inlet hoses have the txjrten Spacers may rubber washer fimnly in place. comeabn another be ear Pulled through shippi g hole. 3. Connect the HOT inlet hose to the HOT inlet Do hum with Piers. connection on the washer and the COLD or not band,kink it\ Inlet hose to the COLD inlet connection on or Pinch water inlet the washer.Tighten by hand until snug.Then hoes' tighten each supply connection moths 2/3 & Turn on the water and turn with pliers.Do not crow tweed or check for leaks. over-tlghten these connections. 4. Connect the HOT,nlel hose fo the HOT water For detailed information,refer to'Connecting Inlet water'in the Installation sections of the use&Care Guide provided with this washer. 7-435-3287)or visit www.electroluxappliances.com.For support in Canada call 1-800-265-83.52 or visit www.electroluxappliances.ca. A17468201(1906) For suppor t in the U.S.call 1-877-4ELECTROLUX(1-87