Loading...
HomeMy WebLinkAboutBLD2010-00336 Revised COM Community Shelter - COM Permit / Conditions - 9/3/2014 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 0010 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2010-00336 OWNER: PIRATES COVE COUNTRY CLUB RECEIVED: 4/29/2010 CONTRACTOR: LICENSE: EXP: ISSUED: 6/11/2010 SITE ADDRESS: 283 E LOMBARD RD SOUTH GRAPEVIEW EXPIRES: 12/11/2010 PARCEL NUMBER: 121085004004 LEGAL DESCRIPTION: PIRATE'S COVE DEDICATED PLAYGROUND PROJECT DESCRIPTION: DIRECTIONS TO SITE: Construction of new Community Picnic Shelter(Reviewed as com) ST RT 3, R ON GRAPEVIEW LOOP RD, R ON LOMBARD RD SOUTH TO SITE ADDRESS ON THE LEFT SIDE, LOCATION OF COMMUNITY PLAYGROUND General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: OTH Insp.Area: No. of Bathrooms: Occ. Group: A-3 Lot Size: Deck: Type of Work: ACC Fire Dist.: 3 No. of Stories: 1 Occ. Load: 45 Building:672 Valuation: Building Height: 16 Occ. Status: Unknown Basement:0 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 110.0 Ft. Shoreline: Ft. Water Body: SEPA?: Unkn Rear: N 156.0 Ft. Slope: Ft. Model: Width: Ft. Shoreline Desig.: h1wtiApplicable Side 1: E 10.0 Ft. Year: Serial No.: Side 2: W 300.0 Ft. I Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 4/29/2010 $108.71 S12010000 Planning Review Fee GMM 4/29/2010 $205.00 S12010000 Fire Warden Review GMM 4/29/2010 $73.00 S12010000 Building State Fee LDK 5/10/2010 $4.50 S12010000 Building Permit Fee LDK 5/10/2010 $167.25 S12010000 Additional Plan Check Fee LDK 6/7/2010 $73.00 S12010000 Total $631.46 BLD2010-00336 Please refer to the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2010-00336 CONDITIONS FOR BLD2010-00336 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. XS 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X_ /4 S 3) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X �T 5) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be applied for, reviewed and approved prior to the change. X 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X_ 7) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 8) Per IRC -SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accord2n.ce with the applicable provisions of this section and the manufacturer's installation instructions. X BLD2010-00336 Please refer to the following pages for oonditions of this permit. 2 of 5 9) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 10) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X S 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. x_�!J S 13) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 41-4 (� 14) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 1( c, 15) All property lines shall be clearly identified at the time of foundation inspection. X BLD2010-00336 Please referto the following pages for conditions of this permit. 3 of 5 16) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason C unty ordinances and building regulations. X ��s 17) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for • action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X a.�s 18) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 19) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 20) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X SWJ S 21) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X V,IJ S 22) Provide 1-2A10BC fire extinguisher within 75 ft of travel placed between 4-60"above floor. X 23) This permit should have been taken in as Com permit. It was reviewed as a Corn and all accessiblity requirements and barrier free requirements must be meet for final. X 24) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X Qom„(/S 25) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6.9 /s' BLD2010-00336 Please referto the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. / l/ OWNERORAGENT: DATE: BLD2010-00336 Please refer to the following pages for conditions of this permit. 5 of 5 CONCRETE MECHANICAL MANUFACTURED HOME I? Gas!Setbacks Date By Ribbons _ _ 0 .D.,i Gas Piping rlI 0o intenor Date By Interior-Date By Date By Cl) Exterior Date By Exterior-Date _ By Set-up C7 Point Load/Isolated Footings INSULATION Date By BG/SLAB INSULATION -- M Date ��-�6 By /ice Data By FIRE DEPARTMENT n Foundation Walls Floors Date By 0 Date By data By DECKS Z FRAMING walls Date By X CIln_ t! By Data By PROPANE TANKS -< PLUMBING G1' Vault Date By n Data By OTHER C Groundwork Attic � By Type. e. Dale By Date By o.w.v DRYWALL Type. Int Brace Wall Date By W Date By Date By FINAL INSPECTION fD Water Line Fire Saperation m Date By Date By Date %!i( By .� (D O Pass or Request Inspect. c Type of Insp. Fail Date Date Dane By Comments w 0 0 v s _5 o a 712-110 QA Cn z d rr ri ro>J�ih arti!' a 0 Zn Ir rya s o�-il- 3 _il- over fax ; o _0 evww j,u„1s� iN 3 /N 1-ti0L' 0 OOb January 23, 2014 Mr. Glen Baskett PO Box 689 Civil Engineers Graham, WA 98338 Structural Engineers Project: Pirates Cove Country Club Picnic Shelter, AHBL No. 210224.20 Subject: Permit No. BLD2010-00336 Landscape Architects Community Planners Dear Mr. Baskett: The picnic shelter is designed as a pole building utilizing cantilevered columns to resist lateral Land Surveyors loads. The plywood ceiling is not a structural component and therefore, at the owner's option, can be omitted from the project. Neighbors If the plywood is removed, the bottom truss chords need to have horizontal bridging installed, as specified on the truss manufacturer's shop drawings. This is typically one or two rows of 2x4's nailed on top of and perpendicular to the bottom chord. If you or the building inspector has any questions, please feel free to contact me on my cell phone at (253) 380-3401. Sincerely, -�� - B Allan E. Bessette, PE, SE Og V4 (S Principal AEB/lsk Q:\2010\210224\WORDPROC\Letters\20140123 Ltr(Permit BLD2010-00336)210224.20.docx 1 28� 9 ,c�a• SIGNALyCs EXPIRES TACOMA 2215 North 30th Street Suite 300 Tacoma,WA 98403-3350 253.383.2422 TEL 253.383.2572 FAx www.ahbl.com � MASON COUNTY J ' BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 2 93 6c' �W>!9111V /'h This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gaincompliance 7'/t/S /S��S"L3Di��"S' A �..� � /f� '�' ��✓.lO� c:/�-�...- f=� .L e-C- You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Q Call for re-inspection when corrections are made before continuing ❑ please contact our office Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" This is not a complete inspection disasters.This is NOT a Date -��/� >C !, CORRECTION NOTICE. Department Inspector !`2 • ,s* o N* OT , rl�L *4 ' THI lqlllllh� TAWM Permit#4 ezZ>16 -65)C MASON COUNTY BUILDING /II 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location L� /?,,0 I-T- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance LET G/-Y —lc �T t�rDfifSstS — y �T�} X 1 ni cc, tee— Cd�✓ You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is_NOTa Date '// AZ-? Department C o CORRECTION NOTICE. Inspector TZ1 Do djT i I iWoU ' ' THIqft, T, MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 411 N. Fifth Street/ P.O. Box 186, Shelton WA 98584 360.427.9670 ext. 352 DDR ay10 - w6d Rec'd by Request for Administrative Variance for Reduction in the Required Setb ks ($115.00) For administrative review, the minimum variance on a setback request is 5 feet from the side yard lot lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction requires a standard variance. Setbacks are measured from the furthest projection of the structure, including roof eaves. L Applicant/Owners. ► t" ,Q Mailing Address: �.� . Uo)( (O Telephone '. l�.�t.• a rj 3 + �Q� a�o�0 City: tI I F, Z_ State: (,a�� Zip: If this reduction is tied to a building permit, please give permit case number. BLD 2Z 10 ♦ 00?z15ja Parcel Number(s): 17.11D� �� Oy�� Zoning 21-5 Site Address: m Requested variance- ront / Rear / Side Yard (please circle all that apply) Requested setback v lance: An illustrated site plan is required. Your site plan must show the following: north arrow, abutting street or easements, set backs to all property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and driveway. Show all proposed new development. The following circumstances must apply: FRONT AND OR REAR YARD REQUIREMENTS: 1) Existing lots of record as of March 5, 2002; You must meet one of the following: (Please circle all that apply) 2) One of the following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c) lot width at the front yard line of no more than 50 feet, d) lot size of no more than one-fourth acre; \\CLUSTERI_HOME_SERVER\HOME\COMMON\COMMUNITY DEVELOPMENT\PAC\VARIANCES\2009 Adminstrative.var.doc Updated: 12-15-2008 e) existing improvements of buildings, septic systems, and well areas. SIDE YARD REQUIREMENTS: 1) Existing lots of record as of March 5, 2002; You must meet one of the following. (Please circle all that apply) 2) One oftthe following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c) lot width at the front yard line of no more than 50 feet; d) lot size of no more than one-half acre; e) existing improvements of buildings, septic systems, and well areas. Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard far Rural Residential 2.5, 5, 10, or 20 zones. (1 E +0 Owner/Agent (please indicate) Signature and date Official Use O 1 Approved G 1. Date �rxf Denied Date Reason for denial: \\CLUSTERI_HOME_SERVER\HOME\COMMON\COMMUNITY DEVELOPMENT\PAC\VARIANCES\2009 Adminstrative.var.doe Updated: 12-15-2008 FORM MUST BE COMPLETED IN INK MASON COUNTY PERMIT N PLEASE PRESS HARD BUILDING PERMIT APPLICATION ltll( 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 - Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner PACC tit C 44jJAY CLLA Company Name Mailing Address 6 0" 6 Mailing Address City 6 a an tv i e w State�_Zip Code 4� ,4( City State Zip Code Phone Other Ph. Phone Other Ph. Holder(_,:!,', r, ill �,.o�a I - -Cbntrictor Reg. # Exp. Lien/Title H^! E mail addressP,a Ior•t �i uc / t�� /gab (�,Yd �a.r E Mail Address Drivers Lic.# DOB Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. Fire District Legal Description Site Address (Please include street name, street number an city) 2 V'3 F. Ld AA 4t Directions to site &QPA C-, L.emRs.eA A, A . So-ri- Will timber be cut and sold in parcel preparation?Yes/ o Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New .-' Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building SA I—Ki Describe Workr., r}ut r PIKA.14i 9•lrl"' Fat yeM,'w- No. of Bedrooms No. of Bathrooms S uare Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck overed Deck-' l.,..' Other Sq. ft. Garage Attached Detach Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFAPROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 18PDAYS WILL INVALIDATE THEAPPLICATION. X Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: ~ :° � Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department qlotfo (.AIL Planning Department Environmental Health Department Ti " I Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES ACCESS & GRADE INSPECTION PERMIT #: .�ZOl r — �-334!!5� ADDRESS 2- 9 INSPECTOR DATE: DRIVEWAY ACCESS Length: Width: Surface: Size of turn-around: Condition of shoulders: Vertical clearance: ) need post at end of driveway with reflective address numbers GRADE,OF DRIVEWAY %, OF ROAD % ROAD ACCESS Length: Width: Surface: Condition of shoulders: Vertical clearance: ( ) BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. ( ) LOT INSIDE SMZ, 4X4 FIRES ONLY. ( ) LOT INSIDE UGA, NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4X4 FIRES. REMARKS (continue remarks on back) Zech Builders RECEIVED Mike Zech 3•� c } 7010 Po Box 516 Grapeview WA 98546 Phone: 360-275-6295 MASON COUNT Fax: 360-275-1412 Proposal Customer Information Name: Glen Baskett—Pirates Cove community Date 4-22-10 Address: Order No. City: State: Zip: Phone: Fax: Qty Description Amount 24x28 picnic cover: Materials including all engineering hardware, lumber, and metal roofing as per drawings. 6,800.00 Framing labor to include post prep and set. 9 .00 Concrete labor and materials for slab. 1,800.00 F Sub Total 18,400.00 Sales Tax 1,545.60 Total 19,945.60