Loading...
HomeMy WebLinkAboutBLD2010-00885 - BLD Plot / Site Plans - 10/13/2010METAL FENCE POSTS 6_ 0" MAXIMUM NOTE: ANGLE SILT FENCE BACK LIP THE SLOPE AT THE END OF RUN. LI FILTER FABRIC MATERIAL 6D" WIDE BOLLS. USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO VIIRE MIRAPI 700X OR PRE —APPROVED EQUAL 2" X 2" X 14g0 WIRE FABRIC OR EQUIV. (OPTIONAL —PER SITE CONDITION) -- BURY BOTTOM OF FILTER MATERIAL IN 6" X 12" TRENCH FILTER FABRIC MATERIAL BACKFILL NTH NATIVE SOIL MATERIAL OR GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FENCE FABRIC ON THE SURFACE EASOIN• TO INTERCEPT DETAIN SMALL AMOUNTS OF SEDIMENT UNDER SHEET FLOW CONDITIONS FROM • DISTURBED AREAS DURING CONSTRUCTION. TO DECREASE VELOCITY OF SHEET FLOWS. TESC DTL: FILTER FENCE NOT TO SCALE STRAW WATTLE STOCKPILES z„--- ANCHOR WEIGHTS W1TH STAKES \\k\ MAX. CONVEY RUNOFF TO APPROVED LOCATION. BURY SHEETING IN 4 IN, X 6 IN. TRENCH A ---\\ MINIMUM OF 8 FT. SETBACK FROM TOP OF SLOPE. BACKFILL 'MTH WASHED ROCK. PROVIDE ENERGY DISSIPATION A T TOE WHEN NEEDED. TOE IN SHEETING IN 4 IN. X 6 IN. TRENCH A MINIMUM OF 3 FT. SETBACK FROM BOTTOM OF SLOPE. BACKFILL WITH WASHED ROCK. CONVEY RUNOFF TO APPROVED LOCATION. 10' MAX. SOIL BERM STRAW BALES CUT SLOPES ANCHOR WEIGHTS WITH STAKES CONVEY RUNOFF TO APPROVED LOCATION. 10' MAX. 3 MIN. EAcON. TO PROVIDE IMMEDIATE TEMPORARY EROSION PROTECTION TO SLOPES AND • DISTURBED AREAS THAT CANNOT BE COVERED BY MULCHING ck MATTING TESC DTL: STOCKPILING NOT TO SCALE SEEDING MAY BE USED ONLY BETWEEN APRIL 1 AND JUNE 30, AND SEPTEMBER 1 AND OCTOBER 30. -- AREA STRIPPED AND THEN TEMPORARILY 7 SEEDED, USING EITHER BONDED FIBER MATRICES OR HYDRO SEEDING TECHNIQUES. )0( STRAW MULCHING; 1. FOR AREAS OF SITE WITH LESS THAN 30% SLOPE; 2-3 BALES OF STRAW EQUALS 2—INCHES OF STRAW MULCH OVER 1000 SOARE FEET. 2. MULCH SHALL BE WEED FREE STRAW. . . .. ..... ........... . . NAME PROPORTIONS BY MIGHT % PURITY % GERMINATION REDTOP (AGROSTIS ALBA) 10% 92 90 ANNUAL RYE (LOLIUM MULTIFLORUM) 40% 9B 90 CHEIMNGS FESCUE (FETUCA RUBRA COMMUTATA) 40% 97 80 WHITE DUTCH CLOVER (TRIFOLIUM PEPENS) 40% 96 90 690 EASO \ I . TO PROVIDE TEMPORARY SOIL STABILIZATION BY PLANTING GRASSES AND LEGUMES TO AREAS THAT VirOULE '1• REMAIN BARE FOR MORE THAN 7 DAYS WHERE PERMANENT COVER IS NOT NECESSARY OR APPROPRIATE. TESC DTL: TEMP SEEDING/MULCHING NOT TO SCALE MIN. 4"-8" QUAP.RY SPALLS GEO—TEXTILE FABRIC 12" MIN. THICKNESS LENGTH PER THE DPD SITE 7— DEVELOPMENT INSPECTOR PROVIDE FULL WIDTH INGRESS/EGRESS AREA STABILIZED ACCESS SHALL BE USED IN ALL AREAS OF THE SITE W1TH VEHICLE TRAFFIC AND PARKING, INCLUDING PLANTING STRIPS. OTHER MEANS OF PROVIDING STABILIZED ACCESS WILL BE CONSIDERED. REASON. TO REDUCE THE AMOUNT OF MUD, DIRT, ROCKS, ETC. TRANSPORTED ONTO - PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF. TESC DTL: TEMP. CONST. ENTRANCE/STAGING NOT TO SCALE // // // /- 1/ // / // 1/ / " \ rlS NO ART OF ADDITION CA, ENCROACH INTO 5' SETBACK NOTCH ROOF AS EEDED7- 7/2 / / / / / / / / / / / / / I/ / // / /1 / / / / / 1 / I/ // iti / /4 / II / I / ij / / / EAS --._ /s'• / / N / / N/ x FILTERbrENCE EMENT '+ • 11 EASEMENT -I PL:, N 89° 54-27" E 10 / / ( f / I / / C.) / Liu 4Q; / / / / ./ / 44' e <(/ I \ / PL: N 89,°. 54.-27" • ( TEMPORARY EROSION AND SEDIMENTATION CONTROL PLAN (TESC) SCALE: 1" = 20' ASSES LINE /— / 13.9 OF BAR SET • DEMO EXIST / N / 7 AREA OF EXIST. STRUCTURE TO REMAIN F.F. =13.5'/ / PLOT PLAN SCALE: 1" = 10' APPROXIMATE OUTLINE OF EXISTING EASEMENT AREA OF EXIST. STRUCTURE TO BE REPAIRED/REMODELED F.F. = 13.5' / li , I „ -i. „ „ , , \ 1.. 1,I -57 , NOTE: SEE ATTACHED SURVEY FOR LOCATION OF NEIGBORING STRUCTURES EXIST. DECK TO BE REMOVED 4 / 7 (//, I / 5 / • :.1 EXIST. 30" F\IR MASO SITE By PL: N 89 ° 54-27" E 983.24 PL: N 89 ° 54'-27"E 7029.78 APPROVt: OUNTY DCD PLANN REQUIRED TO BE ON SIT4// SUBJECT DTatOe APPRO` 15/ 11 11 11 11 // // 1/ // // // // 9.18 --------- // // // // // // / REFERENCE STAKE FROM // // // // (EXIST. FIRE PIT // PERMIT SET ia rwr ill 9/19/2010 sheet \ NOTE: SEE ATTACHED SURVEY FOR LOCATION OF NEIGBORING STRUCTURES number