HomeMy WebLinkAboutBLD2010-00885 - BLD Plot / Site Plans - 10/13/2010METAL FENCE POSTS
6_ 0"
MAXIMUM
NOTE: ANGLE SILT FENCE BACK LIP THE
SLOPE AT THE END OF RUN.
LI
FILTER FABRIC MATERIAL 6D" WIDE
BOLLS. USE STAPLES OR WIRE RINGS TO
ATTACH FABRIC TO VIIRE MIRAPI 700X OR
PRE —APPROVED EQUAL
2" X 2" X 14g0 WIRE FABRIC OR EQUIV.
(OPTIONAL —PER SITE CONDITION)
-- BURY BOTTOM OF FILTER MATERIAL IN 6"
X 12" TRENCH
FILTER FABRIC MATERIAL
BACKFILL NTH NATIVE SOIL MATERIAL
OR GRAVEL BACKFILL IN TRENCH AND
ON BOTH SIDES OF FENCE
FABRIC ON THE SURFACE
EASOIN• TO INTERCEPT DETAIN SMALL AMOUNTS OF SEDIMENT UNDER SHEET FLOW CONDITIONS FROM
• DISTURBED AREAS DURING CONSTRUCTION. TO DECREASE VELOCITY OF SHEET FLOWS.
TESC DTL: FILTER FENCE
NOT TO SCALE
STRAW WATTLE
STOCKPILES
z„--- ANCHOR WEIGHTS W1TH STAKES
\\k\
MAX.
CONVEY RUNOFF TO APPROVED LOCATION.
BURY SHEETING IN 4 IN, X 6 IN. TRENCH A ---\\
MINIMUM OF 8 FT. SETBACK FROM TOP OF
SLOPE. BACKFILL 'MTH WASHED ROCK.
PROVIDE ENERGY DISSIPATION A T TOE WHEN NEEDED.
TOE IN SHEETING IN 4 IN. X 6 IN. TRENCH A
MINIMUM OF 3 FT. SETBACK FROM BOTTOM
OF SLOPE. BACKFILL WITH WASHED ROCK.
CONVEY RUNOFF TO APPROVED LOCATION.
10' MAX.
SOIL BERM
STRAW BALES
CUT SLOPES
ANCHOR WEIGHTS WITH STAKES
CONVEY RUNOFF TO
APPROVED LOCATION.
10' MAX.
3 MIN.
EAcON.
TO PROVIDE IMMEDIATE TEMPORARY EROSION PROTECTION TO SLOPES AND
• DISTURBED AREAS THAT CANNOT BE COVERED BY MULCHING ck MATTING
TESC DTL: STOCKPILING
NOT TO SCALE
SEEDING MAY BE USED ONLY BETWEEN APRIL 1 AND JUNE 30, AND SEPTEMBER 1 AND OCTOBER 30.
--
AREA STRIPPED AND THEN TEMPORARILY
7 SEEDED, USING EITHER BONDED FIBER
MATRICES OR HYDRO SEEDING
TECHNIQUES.
)0(
STRAW MULCHING;
1. FOR AREAS OF SITE WITH LESS THAN 30% SLOPE;
2-3 BALES OF STRAW EQUALS 2—INCHES OF
STRAW MULCH OVER 1000 SOARE FEET.
2. MULCH SHALL BE WEED FREE STRAW.
. . .. ..... ........... . .
NAME
PROPORTIONS BY MIGHT
% PURITY
% GERMINATION
REDTOP (AGROSTIS ALBA)
10%
92
90
ANNUAL RYE (LOLIUM MULTIFLORUM)
40%
9B
90
CHEIMNGS FESCUE (FETUCA RUBRA COMMUTATA)
40%
97
80
WHITE DUTCH CLOVER (TRIFOLIUM PEPENS)
40%
96
90
690
EASO
\ I . TO PROVIDE TEMPORARY SOIL STABILIZATION BY PLANTING GRASSES AND LEGUMES TO AREAS THAT VirOULE
'1• REMAIN BARE FOR MORE THAN 7 DAYS WHERE PERMANENT COVER IS NOT NECESSARY OR APPROPRIATE.
TESC DTL: TEMP SEEDING/MULCHING
NOT TO SCALE
MIN.
4"-8" QUAP.RY SPALLS
GEO—TEXTILE FABRIC
12" MIN. THICKNESS
LENGTH PER THE DPD SITE
7— DEVELOPMENT INSPECTOR
PROVIDE FULL WIDTH
INGRESS/EGRESS AREA
STABILIZED ACCESS SHALL BE USED IN ALL AREAS OF THE SITE W1TH VEHICLE TRAFFIC AND PARKING,
INCLUDING PLANTING STRIPS. OTHER MEANS OF PROVIDING STABILIZED ACCESS WILL BE CONSIDERED.
REASON. TO REDUCE THE AMOUNT OF MUD, DIRT, ROCKS, ETC. TRANSPORTED ONTO
- PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF.
TESC DTL: TEMP. CONST. ENTRANCE/STAGING
NOT TO SCALE
//
//
// /-
1/
// /
//
1/
/
" \
rlS
NO ART OF ADDITION CA,
ENCROACH INTO 5' SETBACK
NOTCH ROOF AS EEDED7-
7/2
/ / /
/ / /
/
/
/ / /
/ / I/ /
// / /1 /
/
/ / / 1 / I/
// iti
/ /4
/ II
/
I /
ij
/
/
/
EAS
--._
/s'• /
/ N
/
/ N/
x FILTERbrENCE
EMENT
'+
•
11 EASEMENT -I
PL:, N 89° 54-27" E 10
/
/ ( f
/
I
/
/
C.) /
Liu
4Q;
/ /
/
/ ./ /
44'
e
<(/
I \
/
PL: N 89,°. 54.-27"
• (
TEMPORARY EROSION AND SEDIMENTATION CONTROL PLAN (TESC)
SCALE: 1" = 20'
ASSES LINE /—
/
13.9 OF BAR SET
•
DEMO
EXIST /
N / 7
AREA OF EXIST.
STRUCTURE TO REMAIN
F.F. =13.5'/
/
PLOT PLAN
SCALE: 1" = 10'
APPROXIMATE OUTLINE
OF EXISTING EASEMENT
AREA OF EXIST.
STRUCTURE TO BE
REPAIRED/REMODELED
F.F. = 13.5'
/ li
, I
„ -i.
„
„
, , \
1..
1,I
-57 ,
NOTE: SEE ATTACHED SURVEY FOR
LOCATION OF NEIGBORING STRUCTURES
EXIST. DECK TO BE
REMOVED
4
/
7 (//,
I /
5
/
•
:.1 EXIST. 30" F\IR
MASO
SITE
By
PL: N 89 ° 54-27" E 983.24
PL: N 89 ° 54'-27"E 7029.78
APPROVt:
OUNTY DCD PLANN
REQUIRED TO BE ON SIT4//
SUBJECT DTatOe APPRO` 15/
11
11
11
11
//
//
1/
//
//
//
//
9.18
---------
//
//
//
//
//
//
/ REFERENCE STAKE FROM
//
//
//
//
(EXIST.
FIRE PIT
//
PERMIT SET
ia
rwr
ill
9/19/2010
sheet
\
NOTE: SEE ATTACHED SURVEY FOR
LOCATION OF NEIGBORING STRUCTURES
number