Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2024-00091 TANK ONLY - SWG Application / Design - 3/8/2024
THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. 415 N 6TH STREET, SHELTON, WA 98584 SHELTON: 360-427-9670, EXT 400 BELFAIR: 360-275-4467, EXT 400 ELMA: 360-482-5269, EXT 400 FAX: 360-427-7787 On-Site Sewage System Tank Only Permit:SWG2024-00091 OWNER CHAMPOUX MONTY & CARLY A Phone:425.709.7002 Address:41934 SE 136TH STREET NORTH BEND, WA 98045 APPLICANT B-LINE CONSTRUCTION Phone:(360) 426-4221 Address:2971 E PHILLIPS LAKE LOOP RD SHELTON, WA 98584 SEPTIC INSTALLER TAYLOR TONEY*Phone:360-426-4221 Address:2971 E PHILLIPS LAKE RD SHELTON, WA 98584 Site Address:32940 N US HIGHWAY 101 Primary Parcel Number:323105002005 Permit Description:Septic Tank only Permit Submitted Date:03/08/2024 Permit Issued Date:03/12/2024 Issued By: Current Permit Fees Paid:$265.00 (additional fees may be required upon installation of system). Permit Expiration Date:03/12/2025 (based on date of inspection) Type of Work OSS Repair Components being Replaced:Septic Tank Only Surfacing Sewage?No Existing Failure?No Shoreline?No Horizontal Setbacks Met?No Number of Bedrooms:4 Drinking Water Source:Private Two-Party Well Additional Details:Existing metal tank to be replaced with 2 compartment infiltrator 1060 Permit Conditions: 3 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 1 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 4 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. Features & Benefits •Strongcompressionmoldedpolypropyleneconstruction •Lightweightplasticconstructionandinboardliftinglugsallow foreasydeliveryandhandling •Integralheavy-dutygreenlidsthatinterconnectwithEZsnap risersandpiperisersolutions •Structurallyreinforcedaccessportseliminatedistortionduring installationandpump-outs •Reinforcedstructuralribbingandfiberglassbulkheadsoffer additionalstrength •Canbeinstalledwith6”to48”(152to1,219mm)ofcover •Canbepumpeddryduringpump-outs •Suitableforuseasaseptictank,pumptank,orrainwater(non- potable)tank •Nospecialwaterfillingrequirementsarenecessary •Thetankmaybebackfilledwithsuitablenativesoil.See installationinstructionsforguidance. TheInfiltratorCM-1060isalightweight,stronganddurableseptictank.ThiswatertighttankdesignisofferedwithInfiltrator’slineofcustom-fitrisersandheavy-dutylids.Infiltratorcompressionmoldedtanksprovidearevolutionaryimprovementinthermoplasticseptictankdesign,offeringexceptionallong-termstrengthandwatertightness. CM-1060 HEAVY DUTY LID CUTAWAY Reinforced24”structuralaccessport Structuralbulkheads Partitionbafflewall Infiltrator EZsnapRiserSystem TANK CUTAWAY MID-SEAM CUTAWAY Reinforcedwatertight mid-seamgasketed connection CM-1060 General Specifications and Illustrations TheCM-1060isacompressionmoldedtwo-piecemid- seamthermoplastictank.TheCM-1060compression moldeddesignallowsforamid-seamjointthathas precisedimensionsforacceptinganengineeredEPDM gasket.Infiltrator’sgasketdesignutilizestechnologyfrom thewaterindustrytodeliverprovenmeansofmaintaining awatertightseal.Thetwo-piecedesignispermanently fastenedusingasystemofmolded-inalignmentdowels andlockingseamclips.TheCM-1060isassembledand soldthroughanetworkofcertifiedInfiltratordistributors. Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436 4BusinessParkRoad P.O.Box768 OldSaybrook,CT06475860-577-7000•Fax860-577-70011-800-221-4436www.infiltratorwater.cominfo@infiltratorwater.com U.S.Patents:8322948;8337119;8297880;7914230;7008138.Otherpatentspending.Infiltrator,Quick4andEZflowareregisteredtrademarksofInfiltratorWaterTechnologies.InfiltratorWaterTechnologiesisawholly-ownedsubsidiaryofAdvancedDrainageSystems,Inc.(ADS). ©2022InfiltratorWaterTechnologies,LLC.Notresponsibleforanytypographicerrors.PrintedinU.S.A.CM020222 TOP VIEW SIDE VIEW END VIEW MID-HEIGHT SEAM SECTION CM-1060 WorkingCapacity 1,111gal(4,207L) TotalCapacity 1,309gal(4,956L) Airspace 17.8% Length 134.2”(3,409mm) Width 61.7”(1,567mm) Length-to-WidthRatio 2.3to1 Height 54.5”(1,384mm) LiquidLevel 44”(1,118mm) InvertDrop 3”(76mm) FiberglassSupports 2 Compartments 1or2 MaximumBurialDepth 48”(1,219mm) MinimumBurialDepth 6”(152mm) MaximumPipeDiameter 4”(102mm) Weight 331lbs(151kg) Must be backfilled and installed in accordance with the Infiltrator IM- and CM-Series Septic Tank General Installation Instructions. For shallow ground water conditions reference the Infiltrator IM- and CM-Series Tank Buoyancy Control Guidance. Please visit www.infiltratorwater.com or scan QR code for the latest information. SEAM CLIP (TYPICAL) LIFTING STRAP(TYPICAL) OUTLET 134.2 [3,409] EXTERIOR LENGTH RISER CONNECTION (TYPICAL) 61.7[1,567]EXTERIORWIDTH LIFTING STRAP (TYPICAL) LIFTING LUG (4 TOTAL) PER CODE PER CODE 3.0[76] 44.0[1,118]LIQUIDDEPTH 10.1 [257] FREEBOARD Ø 4 [102] PVC OR ABSINLET TEE OUTLET Ø 4 [102]PVC OR ABS OUTLET TEE FIBERGLASSSUPPORT (TYPICAL) 17.0% AIR SPACE Ø 24.0 [610] ACCESS PORTWITH LOCKING LID (2) INLET 54.5[1,384]EXTERIORHEIGHT TANK TOPHALF TANK INTERIOR TANK BOTTOM HALF CONTINUOUS ELASTOMERIC GASKET INTEGRAL ALIGNMENT DOWEL SEAM CLIP FIBERGLASSSUPPORT(TYPICAL) WITH BAFFLE WALL WHERE REQUIRED SEAM CLIP (TYPICAL) LIFTING STRAP (TYPICAL) OUTLET 134.2 [3,409] EXTERIOR LENGTH RISER CONNECTION(TYPICAL) 61.7[1,567]EXTERIORWIDTH LIFTING STRAP(TYPICAL) LIFTING LUG (4 TOTAL) PER CODE PER CODE 3.0[76] 44.0[1,118]LIQUIDDEPTH 10.1 [257] FREEBOARDØ 4 [102]PVC OR ABSINLET TEE OUTLET Ø 4 [102] PVC OR ABS OUTLET TEE FIBERGLASS SUPPORT (TYPICAL) 17.0% AIR SPACE Ø 24.0 [610] ACCESS PORTWITH LOCKING LID (2) INLET 54.5[1,384]EXTERIORHEIGHT TANK TOP HALF TANK INTERIOR TANK BOTTOM HALF CONTINUOUS ELASTOMERIC GASKET INTEGRAL ALIGNMENTDOWEL SEAM CLIP FIBERGLASSSUPPORT (TYPICAL) WITH BAFFLE WALL WHEREREQUIRED SEAM CLIP (TYPICAL) LIFTING STRAP (TYPICAL) OUTLET 134.2 [3,409] EXTERIOR LENGTH RISER CONNECTION(TYPICAL) 61.7[1,567]EXTERIORWIDTH LIFTING STRAP(TYPICAL) LIFTING LUG (4 TOTAL) PER CODE PER CODE 3.0[76] 44.0[1,118]LIQUIDDEPTH 10.1 [257] FREEBOARDØ 4 [102]PVC OR ABSINLET TEE OUTLET Ø 4 [102] PVC OR ABS OUTLET TEE FIBERGLASS SUPPORT (TYPICAL) 17.0% AIR SPACE Ø 24.0 [610] ACCESS PORTWITH LOCKING LID (2) INLET 54.5[1,384]EXTERIORHEIGHT TANK TOP HALF TANK INTERIOR TANK BOTTOMHALF CONTINUOUS ELASTOMERIC GASKET INTEGRAL ALIGNMENTDOWEL SEAM CLIP FIBERGLASSSUPPORT (TYPICAL) WITH BAFFLE WALL WHEREREQUIRED 1Rhonda Thompson From:Taylor Toney <taylor@b-lineconstruction.com>Sent:Monday, March 11, 2024 2:39 PMTo:Rhonda ThompsonSubject:Tank only permit As discussed on the phone, the well that is on the l ot to the north is approx. 65' from tank location and the well on the homeowners parcel is 50' to the tank location. As for the water line and transport line, there will be two ditches 10' apart and in the places that we need to cross we will double the case where needed. Let me know if there are any other questions that I can answer for you. -- Best, Taylor Toney, Lead B-Line Construction, Inc. Office: (360) 426-4221 Cell: (360) 489-9169 To help protect your priv acy, Microsoft Office prevented automatic download of this picture from the Internet. Please Note: The best time to reach me is between the hours of 6:30a to 8:00a by calling the number above. Caution: External Email Warning! This email has originated from outside of the Mason County Network. Do not click links or open attachments unle ss you recognize the sender, are expecting the email, and know the content is safe. If a link sends yo u to a website where you are asked to validate using your Account and Password, DO NOT DO SO! Instead, report the incident.