HomeMy WebLinkAboutBLD2008-00564 - BLD Plot / Site Plans - 8/20/2008PROPOSED DRAINFIELD TO BE
ADJACENT TO GRAPEVIEW LOOP
ROAD PER SEPTIC DESIGN
CC
AC
gm mil — ME IME INE ME ME ME MEI NM ME ME ME ME
PRI'. V? 0 SOT? YE '1
TO GRAPEVIEW
LOOP ROAD
20' EASEMENT FOR ROAD AND
LOT 1
'
goik0
LOOP
— —
S 87°36'46" E 600.25
//,5
•
•
•
5ro ,
NSTRUCTION
CESS ROAD
mm mm mm mm mm mm mm mm mm mm
730.00
NN.
10' GRAVEL ROAD
UTILITY RIRPOSES7-
71 0.00
...... ..... .....
a... .1,
a... ......
••••• .....
•••• Ss
.s.. .....
.....
••„,
GRAVEL
R
„ / •••'' '• •
1-0
FIRE APPARATUS
ACCESS ROAD
'--TURNOUT EVERY
150' ALONG
DRIVEWAY AS
REQUIRED
1.1111—EM-1111E—MIE EE—I
•
5
(E) EASEMENT TO BE
ABANDONED
PROPOSED REVISED
LOCATION OF UTILITY
EASEMENT
LINE OF MODIFIED HAMMER
HEAD TURN AROUND TO BE
ON PASTURE PER COUNTY
FIRE DEPT. REQUIREMENTS
S 8736'46" E 859.59
-•••,„
mm • mm m'ille/
0
PROPOSED
DRIVEWAY
lmm•--mm7immm•-mm-m
....
,/' , - . • . /- ...-•
,, .▪ ., .../ • .
•/"."
,,f• to
:
„"
LOT
..... ..... .....
I .
MOBILE
(EAVES)
-•-••••••,","••••••-• -•••••••••••••• •••••,-"•••— ••••-•-•-•••••••••• •
(31
0
OrD
-mm-mm-m-mm-mm-mm.--- -ming AmEmmm-
X17.111Eit)(:)(:)
S 87.36'46" E 241.48
5.
HOUSE
(EAVES)
•:,..
461-4 i $-., - /
,..., ..
------.....-..... 23'_4" ._:
i
.... .............................
BUILDING jWIDTH 1 \
mm mu am Amm mo mu um mo Mil wm no mos mm
.,
.----:
231.48
BUILDING WIDTH/
54
By
SHORELNE
SETBACK PER
COUNTY
REQUIREMENTS
/2
/
/
/
.,- 1',
i
I /
143 S.F. ALLOWED
It I I --
PER (E)
NON —CONFORMING
CONDITION f I
I i
$
7--- — 1— 41 55
23'-1”\\
APPROVED
MASON COUNTY DOD PLANNING
SITE PLAN REQUIRED TO BE ON SITE
GES SUBJECT TO APPROVAL
Date leA9
SI ORT PLAT NO. 2062
/
,
-
;
./
;•• es'
/
L...
; .
(E) BENCHMARK,
SEE SURVEY
orrz
(E) BENCHMARK,
SEE SURVEY
55
•5.
55
LEGEND
EXISTING CONTOUR
--- PROPOSED CONTOUR
SLOPE GREATER THAN 15%
16' 8' 0 16'
SCALE IN FEET
32'
CA
SECOND
(NC
H dIT
collaborative, Ilc
3400 PHINNEY AVE N., STE 200
SEATTLE, WASHINGTON 98103
T: 206,545.0700
F: 206.545.0702
E: www.hdltcollaborative.com
REVISION
DATE
OWNER APPROVAL
DATE
STAMP
7100
GISTERED
HITECT
S. CH
ST E OF
L HOFFMAN
ASHINGTON
No dimensions should be scaled from drawings and oh dimensions
and values should be checked and verified against field conditions.
If any dimensions are found to be incorrect or invalid, then it is
the responsibility of the user to inform the Architect, and to obtain
the correct dimensions prior to acting upon anything contained in
these drawings. Contractor to verify all dimensions, conditions, etc.
pertaining to the Work on site before proceeding with the Work.
Copyright 0 2007 H+dIT Collaborative. All rights reserved.
PRINCIPAL IN CHARGE
CARLOS DE LA TORRE
PROJECT TEAM
CDLT, AZF
REVIEWED
CDLT
DRAWN
AZF
SHEET TITLE
SITE PLAN
PLANNING: . I
ALL SETBACKS ARE MEASURED
FROVVTITIE::FURTH EST
ROJECT:ONOF THEi3UILDING
/ 0 0 1
1.) 624
NORTH
11 I
SITE PLAN SCALE:
1/16"=11-0"
PROJECT NUMBER
0622,000
SHEET NUMBER
A1.1