Loading...
HomeMy WebLinkAboutBLD2009-00219 - BLD Plot / Site Plans - 4/22/2009GREEN BUILDING PRACTICES: I. WOOD: A. USE SUSTAINABLY HARVESTED FSC-CERTIFIED WOOD FOR FRAMING & TRIM WHERE POSSIBLE OR AS SPECIFIED BY ARCHITECT B. SPACE FRAMING ON 24" CENTERS W/ DOUBLE TOP PLATE WHERE POSSIBLE; (VFY. w/ STRUCTURAL ENGINEER) C. USE ONLY SUSTAINABLY HARVESTED TROPICAL HARDWOOD TRIM OR CABINETS; AS SPECIFIED BY ARCHITECT D. USE ENGINEERED WOOD WHERE POSSIBLE -- VERIFY W/ ARCHITECT/STRUCTURAL ENGINEER E. USE INTERIOR DOORS CONSTRUCTED OF DOMESTICALLY GROWN WOOD WHERE POSSIBLE; NO LUAN UNLESS OTHERISE SPECIFIED F. USE REMILLED SALVAGED TIMBER WHERE POSSIBLE; AS APPROVED BY ARCHITECT 2. INSULATION: A. USE FORMALDEHYDE/CFC/HCFC- FREE FIBERGLASS INSULATION OR ULTRA TOUCH NATURAL COTTON FIBER INSULATION WHERE POSSIBLE B. INSULATE HEADERS WHERE POSSIBLE; SEE STRUCTURAL C. FULLY INSULATE CORNERS (REQUIRES 2-STUD INSTEAD OF 3-STUD CORNERS) AND AT INTERIOR/EXTERIOR WALL INTERSECTION WHERE POSSIBLE; SEE STRUCTURAL 3. FINISHES AND PAINTS TO BE LOW VOC, UNLESS OTHERWISE SPECIFIED BY ARCHITECT 4. SUPPLIERS: USE LOCAL SUPPLIERS, WITHIN 500 MILES, WHENEVER POSSIBLE. ITEMS OVER 500 MILES TO BE APPROVED AND/OR SPECIFIED BY ARCHITECT. 5. BUILD TO "GREEN" CODES & SPECIFICATIONS: A. MEET WASHINGTON STATE WATER USE EFFICIENCY STANDARDS B. MEET STORMWATER/SITE DEVELOPMENT STANDARDS C. MEET WASHINGTON STATE ENERGY CODE D. MEET WASHINGTON STATE VENTILATION/IAQ CODE 1 w w V i TAX PARCEL # 120205000009 20'-0" ® ' 'CO c_ E POINT WILSON RD. SITE PLAN 1". 20' c_ OF E PT. WILSON RD SITE SECTION 1"=40' +1 ; o I 0 O O 0 1 I I I 1 I sJCp-ili"c 6. 7. 8. APPLIANCES: A. ENERGY & WATER -EFFICIENT APPLIANCES TO BE USED (HIGH EFFICIENCY WATER HEATER), LOCATED NEAR POINT OF HIGHEST USE, INSULATE PIPE WITHIN 3 FEET OF THE HWH, OR ON -DEMAND WATER HEATER @ FARTHEST POINT FROM GREATEST USE. WHEN POSSIBLE USE SOLAR HOT WATER HEATER AS BACKUP. B. APPLIANCES SHOULD HAVE ENERGY STAR OR ENERGY GUIDE LABLES 9. IOBSITE: A. REDDUCE JOBSITE WASTE; PREPARE JOBSITE RECYCLING PLAN AND POST ON SITE B. USE SUPPLIERS WHO OFFER REUSABLE OR RECYCLABLE PACKAGING WHEN POSSIBLE C. PROVIDE WEATHER PROTECTION FOR STORED MATERIALS D. REQUIRE SUBCONTRACTORS TO PARTICIPATE IN WASTE REDUCTION EFFORTS & 10. RECYCLING EFFORTS I I. E. REUSE BUILDING MATERIALS WHERE POSSIBLE 12. F. USE REUSABLE SUPPLIES FOR OPERATIONS SUCH AS CONSTRUCTION FENCES, TARPS, REFILLABLE PROPANE TANKS G. MOVE LEFTOVER MATERIALS TO NEXT JOB OR PROVIDE TO OWNER H. SELL OR GIVE AWAY WOOD SCRAPS I. SELL OR DONATE REUSABLE ITEMS J. EMPLOY REUSABLE FORMS K. SAVE AND REUSE SITE TOPSOIL L. RECYCLE: CARDBOARD, METAL SCRAPS, WOOD SCRAP & BROKEN PALLETS, PACKAGING, DRYWALL, CONCRETE/ASPHALT RUBBLE, ROCK AND BRICK, PAINT, ASPHALT ROOFING, CARPET, CARPET PADDING, FLUORESCENT LIGHTS, LANDCLEARING AND YARD WASTE, SOIL & SOD M. SINGLE STABILIZED CONSTRUCTION ENTRY N. LIMIT HEAVY EQUIPMENT USE ZONE TO LIMIT SOIL COMPACTION CAULKING: A. USE ADVANCED CAULKING TECHNIQUES: CAULK OR GASKET DRYWALL WHICH IS INSTALLED ON EXTERIOR WALLS AT THE TOP & BOTTOM PLATES, (E) GRAVEL DRIVE 0 0 ® I I I -1- -1- 230'-11%2 W/11 f ®/ / PROPERTY CORNER GENERAL NOTES: 1. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL EXISTING AND NEW UTILITIES AND SITE CONDITIONS BEFORE AND DURING CONSTRUCTION. INFORM ARCHITECT OF VARIATIONS BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. 2. ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE CURRENT EDITIONS OF ALL APPLICABLE CODES AND ORDINANCES. ALL METHODS, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE 2006 IRC, IMC, IFC, WASHINGTON STATE AMENDMENTS, AND WASHINGTON STATE ENERGY CODE. 3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IN CASE OF ANY DISCREPANCIES. 4. DIMENSIONS ARE TO FACE OF MASONRY, FACE OF ROUGH FRAMING, CENTERLINE OF COLUMN, OR CENTERLINE OF ROUGH OPENING, UNLESS NOTED OTHERWISE 5. TYPICAL INTERIOR PARTITIONS ARE 2X4 AT 16" O.C. U.N.O. 6. FLOOR LINE REFERS TO TOP OF FINISHED FLOOR, UNLESS NOTED OTHERWISE. 7. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL BE 4" FROM FACE OF FINISHED WALL TO EDGE OF DOOR OPENINGS, OR CENTERED BETWEEN ROOM PARTITIONS AND /OR OTHER BUILT-IN FIXTURES, AS SHOWN. 8. VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT OR BY OTHERS. 9. VERIFY SIZE AND LOCATION OF, AND PROVIDE ALL OPENINGS THROUGH FLOORS AND WALLS, FURRING CURBS, ANCHORS, INSERTS, MACHINE BASES, AND ROUGH BUCKS AND BACKING FOR, SURFACE MOUNTED ITEMS. INSTALL ALL PIPING IN WALL AND FLOOR SPACE WHERE STRUCTURALLY POSSIBLE. 0 EXIST G CABINS TO EMAIN 0 1. 436'-7" PARCEL LENGTH i WINDOWS AND DOORFRAMES, AT INTERSECTIONS WITH EXTERIOR WALLS AT INTERIOR. CAULKED DRYWALL IS USED AT ELECTRICAL PLUMBING & MECHANICAL PENTRATIONS INTO DRYWALL. B. USE LOW -TOXIC, WATER -BASED, SOLVENT -FREE SEALERS, GROUTS, MORTARS, CAULKS, AND ADHESIVES INSIDE THE HOUSE SITE PROTECTION: A. PRESERVE AS MUCH EXISITING NATIVE VEGETATION AS LANDSCAPING AS POSSIBLE B. PROTECT TREES DURING CONSTRUCTION C. REPLANT OR DONATE REMOVED VEGETATION FOR IMMEDIATE REUSE D. GRIND LANDCLEARING WOOD AND STUMPS FOR REUSE USE FORMALDEHYDE -FREE PLYWOOD & COMPOSITES WHERE POSSIBLE. USE POLYETHELENE PIPING FOR PLUMBING (NO PVC) WHERE POSSIBLE CONCRETE: USE FLYASH IN CONCRETE, REGIONALLY -PRODUCED BLOCK, RECYCLED 414.41'± • ♦♦ 436.60'± OUTLINE OF (E) HOUSE TO BE DEMO. 1-T • • • ♦♦ • PROPOSED STRUCTURE SETBACK LINE ♦• ♦ 0 N • • ♦ ♦ • ♦ • • ♦ • • SHEET INDEX: ARCHITECTURAL AI.0 SITE PLAN, GEN. NOTES A2.1 FIRST + SECOND FLR PLANS A2.2 ROOF PLAN A3.I EXTERIOR ELEVATIONS A3.2 EXTERIOR ELEVATIONS A4.I BUILDING SECTIONS A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 CHIMNEY/FIREPLACE DETAILS A6.I WIN. AND DR SCHEDS. ELECTRICAL E2. I ELECTRICAL PLANS • • ♦ • • • • 0 • • • • • \ • • • • • • • ♦ • • • • • ♦ • • 0 N ♦ ♦ EXIST. BULKHEADS STRUCTURAL SI.O GEN. STRUCT. NOTES S 1.1 GEN. STRUCT. NOTES S2.0 FOUNDATION PLAN S2.I FIRST FLR. FRAMING S2.2 SECOND + ROOF FRAMING S3.0 TYP FOUND. DETS. S3.I TYP CRAWL DETS. S4.0 TYP WOOD DETS. S4.I TYP WOOD DETS. S4.5 SPECIFIC STRUCT. DETS. 1 O LOCATION OF (E) ACCESSORY DWELLING UNITS TO REMAIN 10. PROVIDE SOLID BLOCKING BEHIND ALL WALL HUNG FIXTURES AND ACCESSORIES. I I. THE SEISMIC ANCHORAGE OF THE WATER HEATER TO INCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER & LOWER ONE-THIRD OF ITS VERTICAL DIMENSION. THE 16. LOWER ANCHOR/STRAP LOCATED TO MAINTAIN A MINIMUMUN DISTANCE OF 4 17. INCHES ABOVE THE CONTROLS. WATER HEATER TO BE PLACED 18" ABOVE FLOOR ON PLATFORM. 12. ALL HOSE BIBS AND LAWN SPRINKLERS SHALL HAVE APPROVED BACKFLOW I8. PREVENTION DEVICES. 13. GARAGE SEPARATION SHALL BE IN ACCORDANCE W/ IRC R309.2 19. 14. BATHROOMS/ SHOWERS. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO SET-UP INSTRUCTIONS. PLUMBING AND MECHANICAL PERMITS REQUIRED FOR ALL WORK. 20. SHOWERS TO BE FINISHED WITH SMOOTH, HARD, NON-ABSORBANT SURFACE NOT AFFECTED BY MOISTURE. SHOWERS AND LAVATORIES SHALL HAVE FLOW CONTROL DEVICES OR AERATORS TO LIMIT TOTAL WATER FLOW RATE TO 3 GPM. TUB OR SHOWER ENCLOSURE WALLS SHALL BE HARD NON -ABSORBENT SURFACE OVER W.R. GWB TO HEIGHT NOT LESS THAN 70" ABOVE DRAIN. ANY GLAZING IN SHOWER OR TUB DOORS OR ENCLOSURE WALLS SHALL BE TEMPERED OR SAFETY GLASS; ANY GLAZING LESS THAN 60 INCHES ABOVE THE DRAIN IN BUILDING WALLS SHALL BE TEMPERED OR SAFETY GLASS; IRC R308.4-SHOWER DOORS TO OPEN OUTWARDS; HOT 21. WATER HEATERS INSTALLED PER IRC Chapter 20, 24, and 28. 15. EMERGENCY EXITING/EGRESS WINDOWS; per IRC R3 I0 MINIMUM ONE WINDOW OF EXTERIOR WINDOW OR EXTERIOR DOOR IN EACH BEDROOM. 5.7 SF MINIMUM NET 22. OPENING; 20" MINIMUM CLEAR VVIDTH; 24" MINIMUM CLEAR HEIGHT; EMERGENCY ROOF PITCH: .75/12 EXISTING/ USE HO / / _a w SECOND FLOOR $ 9'-0" ti0 N a cv FIRST FLOOR ESCAPE AND RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. FIREBLOCKING & DRAFTSTOPS; per IRC R3I5, R502.12 GUARDRAILS; per IRC R3 I2 REQUIRED FOR ALL WALKING SURFACES 30" ABOVE 23. ADJACENT GRADE OR FLOOR BELOW. 36" MINIMUM REQUIRED HEIGHT; MAXIMUM CLEAR SPACE BETWEEN INTERMEDIATE RAILS TO BE LESS THAN 4". INSULATION REQUIREMENTS; per 2006 WASHINGTON STATE ENERGY CODE: SEE ENERGY SUMMARY A1.0 MECHANICAL & APPLIANCES: FURNACES, DUCTING, AND APPLIANCES per UMC Chapters 2, 3, 6, 7, 9, 13, NATURAL LIGHT & VENTILATION; per IRC Section R303 EXTERIOR GLAZED OPENINGS TO BE AREA AT LEAST I/10 OF FLOOR AREA OF HABITABLE ROOM; MINIMUM 10 SF. 24. OPERABLE WINDOW AREA MUST BE 1/20 OF FLOOR AREA FOR NATURAL VENTILATION OF HABITABLE ROOMS, MINIMUM 5 SF. BATHROOMS AND LAUNDRY ROOMS SHALL HAVE NATURAL LIGHT AND VENTILATION NOT LESS THAN 1/20 OF THE FLOOR AREA; MINIMUM 1.5 SF; UNLESS PROVIDED WITH A MECHANICAL AND VENTILATION SYSTEM 25. CONNECTED DIRECTLY TO THE OUTSIDE CAPABLE OF PROVIDING FIVE AIR CHANGES PER HOUR. SMOKE ALARM; per IRC R3 13 PROVIDE AND INSTALL PER IRC LOCATIONS. ALL SMOKE 26. ALARMS TO BE LISTED AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE PROVISIONS OF NFPA 72. TO BE PLACED IN ALL SLEEPING ROOMS STAIR DESIGN; per IRC R3I 1.5 MAXIMUM 7 3/4" RISE, MINIMUM 10" TREAD; MINIMUM 6'-8" HEADROOM; MINIMUM 36" WIDE. TOP OF HANDRAIL TO BE 34"-38" ABOVE STAIR MASON C SITE P1_i • CHAR2ES PROPERTY CORNER PROPERTY LINE @ SECTION CUT m 0 -n rn ELEV. 0'-0" NOSING, MINIMUM I-1/4" IN CROSS SECTION AND MAXIMUM 2"; MINIMUM SPACE BETWEEN HANDRAIL AND WALL TO BE I-1/2"; OPEN STAIRWAYS REQUIRE GUARDRAIL PROTECTION; IRC Section R3 12 VENTILATION/ROOM; per WASHINGTON STATE ENERGY CODE KITCHEN EXHAUST TO BE MINIMUM 100 CFM intermittent or 25 CFM continuous; BATHROOM AND LAUNDRY EXHAUST TO BE MINIMUM 50 CFM intermittent or 20 CFM continuous; WHOLE HOUSE EXHAUST TO BE MINIMUM 80 CFM (I bedroom), MAXIMUM 120 CFM (3 bedrooms). FANS TO ACHIEVE REQUIRED FLOW RATE AGAINST 0.25 INCHES WATER GAUGE (W.G.) PRESSURE WHEN TESTED AS PER HVI STANDARD 916, or AMCA Standard 210. VENT DIRECTLY TO OUTSIDE (UNLESS CONNECTED TO HEAT RECOVERY SYSTEM) NOT LESS THAN 3 FEET FROM OPERABLE WINDOW(S). VENTILATION/ ROOF; per IRC R806 ONE SF NET -FREE VENTILATION AREA PER 150 SF OF ROOF AREA, 50% OF VENT AREA TO BE LOCATED IN UPPER PORTION OF THE SPACE. COVER WITH CORROSION -RESISTANT WIRE MESH WITH OPENING MIN. I/8"-MAX. 1/4" IN DIMENSION. CROSS VENTILATION REQUIRED. WALL COVERING FOR MIMIMUM THICKNESS AND APPLICATION OF GWB SEE IRC TABLE R702.3.5 GWB SHALL BE USED OVER VAPOR RETARDER IN HIGH HUMIDITY AREAS SUCH AS TUB/SHOWER ENCLOSURE CEILINGS. GWB TO BE RECYCLED GYPSUM WALL BOARD. WOOD & FRAMING; per SUBMIT ENGINEERED FRAMING DETAILS TO BUILDING DEPARTMENT. PROVIDE UPLIGHT AND SLIDING ANCHORAGE OF ALL WALLS, COLUMNS, BEAMS, JOISTS, RAFTERS, AND/OR TRUSSES WITH APPROVED CONNECTORS; SEE STRUCTURAL NOTES. FSC CERTIFIED WOOD TO BE USED FOR ALL FRAMED WALLS. PROJECT DIRECTORY SITE ADDRESS: 132I EAST POINT WILSON RD. SHELTON, WA 98584 OWNER: CHRISTOPHER + STEPHANIE DALEY-WATSON 11268THW SEATTLE WA 98119 (206) 465-1416 ARCHITECT: PRENTISS ARCHITECTS, INC. 224 WEST GALER SEATTLE, WASHINGTON 981 19 (206) 283-9930 CONTACT: KOZO NOZAWA CONTRACTOR: TERRY EVANS STRUCTURAL ENGINEER: QUANTUM CONSULTING ENGINEERS I51 1 THIRD AVENUE SEATTLE, WA 98101 (206) 957-3900 CONTACT: DAN FENTON, P.E., S.E. www.quantumce.com PROJECT DESCRIPTION CONSTRUCTION OF A NEW SINGLE FAMILY RESIDENCE: 3 BEDROOMS, 3 BATHROOMS LEGAL DESCRIPTION POINT WILSON TRACTS TR 9 & TAX I I34-A-2 LAND USE: I BEDROOM TIDE RUN/LGN SW FR TAX ASSESORS PARCEL NO.: 120205000009 ENERGY SUMMARY: ALL NEW CONSTRUCTION WILL COMPLY WITH THE FOLLOWING PRESCRIPTIVE REQUIREMENTS: 2006 WA STATE ENERGY CODE PRESCRIPTIVE OPTION IV FOR CLIMATE I, R-3 W/ UNLIMITED GLAZING: GLAZING = U.35 MINIMUM VERTICAL/ U.58 OVERHEAD GLAZED DOORS = U.40 MINIMUM (PER 602.6 EXEMPTION 2) SOLID DOORS = U.20 MINIMUM (I) EXEMPT DOOR = 24 SF (PER 602.6 EXEMPTION I) WALLS = R-21 SLAB = R- I0 RIGID (FULLY INSULATED) FRAMED FLOORS = R-30 BATTS VAULTED CEILINGS = R-30 BATTS OTHER CEILINGS = R-38 BATTS SQUARE FOOTAGE: NEW CONSTRUCTION TOTAL NEW CONSTRUCTION: IMPERVIOUS AREA: PROPOSED GRAVEL DRIVEWAY/PARKING ROOF AREA OF ALL PROPOSED BUILDINGS PROPOSED DECKS, PATIOS, COVERED PORCHES PROPOSED SPORTS SURFACES (TENNIS COURT,ETC.) ROOF AREA OF ALL EXISTING BUILDINGS BUILT AFTER SEPT. I , 199 I AREAD OF EXISTING DRIVEWAYS, PARKING AREAS, DECKS, PATIOS, AND SPORTS SURFACES BUILT AFTER SEPT. I, 1991 TOTAL IMPERVIOUS SURFACE AREA: EXCAVATION/FILL: NEW CONSTRUCTION: APPROX. CUBIC YARDS OF EXCAVATION FOR FOOTINGS AND FOUNDATION WALL - TO BE SPREAD THROUGHOUT PROPERTY. VICINITY PLAN NTS 2155 SQ. FT. 2155 SQ. FT. 0 SQ. FT. 2155 SQ. FT. 480 SQ. FT. 0 SQ. FT. 0 SQ. FT. 0 SQ. FT. 2635 SQ. FT. McMICKEN ISLAND STATE PARK SITE LOCATION CC LiJ CC co CV CO CD o CO BUILDINGS + LANDSCAPES 0 02 LU co 6515 ARCHITECT STATE OF WASHINGTON PROGRESS SET # DATE NOTES PRINT DATE: 03.26.2009 PROJECT ARCHITECT: KRN DRAWN BY: KRN SITE PLAN A1.0