Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
bld2007-02048 - BLD Plot / Site Plans
Master Bedroom Master Bath • W.I.C. • 10 ,S D •G) • SHOWER L CLOSET • Bedroom (SD) Bath SD) , Wet Bar Pwd. (SD) SD; Den r Living CEILING BREAK $ WALL LINES ABOVE Entry Dining CEILING BREAK LI N ES -TYPICAL �) /UPPER CABINETS /- / // / / / OPEN TO ABOVE Covered Porch AFCON 514 Common Installations Vertical Support and Restraint Front Horizontal Stabilize and Restraint AFCON FIGURE 514- - CPVC HANGER `C_Or1.-}:a Sprint/ �ft I\Eod 1� i fi.Er-1.�(�F � Cam- + RCN-S ,1-Nc `. nSf�c-� FLOOR PLAID Kitchen 1 1/4 UPPER CABINETS 3/4" CONNECTION TO TANK FOR WATER FILL (BY OTHERS) Covered Deck CRY Nook • (xl Utility DAYTON 4RJ67 2HP PUMP RATED TO SUPPLY: 40 GPM © 32.9 PSI (WIRED BY OTHERS) Q� r 'be- h e -V c csi G- o Garage SCALE: 1/4" =1 '-0' AFCON FIGURE 515 - CPVC HANGER STEEL CEILING PLATE ALL THREAD ROD ADJUSTABLE RING HANGER CEILING PLATE, ROD AND RING J GENERAL NOTES ALL PIPING IN ATTIC TO BE COVERED (TENTED) WITH INSULATION ALL SPRINKLER HEADS AND PIPING TO BE INSTALLED ACCORDING LISTING. PIPE TO BE SUPPORTED AT 6' o/c MAX. (1" CPVC) WITH WOOD JOIST CLIP, OR JOIST PENETRATION. SUPPORT PIPE WITHIN 6" OF ALL DROPS TO SPRINKLER HEADS. MAXIMUM SPACING OF SPRINKLERS IS 9' OFF WALLS, 18' X 18' AT FLAT CEILINGS. MAXIMUM SPACING OF SPRINKLERS IS 8' OFF WALLS, 16' X 16' AT SLOPED CEILINGS. NO SLOPE TO BE MORE THAN 8 IN 12. ALL PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. SYSTEM HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA MOST REMOTE 2 HEADS. BY OTHERS. TO THEIR HEADER, MAXIMUM SPACING MAXIMUM SPACING 13D FOR THE TOR 11/4" CPVC 1 V "x11/4' SUP X THREAD ADAPTER 3/4" FILL BY OTHERS 300 GALLON TANK 11I GRV COUP. 6" ELECTRIC BELL (WIRED BY OTHERS) 11/2" RELIABLE 13R RISER MANIFOLD WITH GAUGE, FLOW SWITCH, AND TEST -AND -DRAIN PUMP PRESSURE SWITCH 11/2" BRASS CHECK VALVE —11/2" GROOVED COUP. —11/2"x11/4" TxT REDUCER —2.0 HP PUMP e,__/ PUMP & TANK DETAIL FLOW TESTI CHURN: 56.7 psi RESIDUAL: 32.9 psi FLOWING: 40 gpm SOURCE: 2 HP PUMP NOT TO SCALE I COPY I t• APPROVED MASON COUNTY FIREMA�SRAL DATE-` 2. "Q1 BY �„�' SUBJECT TO FIELD INSPECTION ACL APPLICABL• CODES SHALL APPLY. EFPOanS AND/OR OMISSIONS ON PLANS ARE SOLE RE- SPONSIBILITY OF OWNER CONTRACTOR. CORREC- TIONS REQUITED FROM FIELD IHSPECT'ON SHALL BE AT OWNER%CONTRACTOR'S EXPENSE. THIS AP- PROVAL DOES NOT GRANT TO ANY PERSON THE RIGHT TO VIOLATE ANY CITY OR STATE LAWS. J SPRINKLER LOCATION NEAR HEAT SOURCES SPRINKLERS MUST BE PLACED A SUFFICIENT DISTANCE AWAY FROM COMMON RESIDENTIAL HEAT SOURCES THAT INCLUDE KITCHEN RANGES, WALL OVENS, FIREPLACES, STOVES, LIGHT FIXTURES, HOT WATER PIPES, WATER HEATERS, FURNACES, AND ASSOCIATED FLUES AND DUCTS. SPRINKLERS INSTALLED TOO CLOSE TO THESE HEAT SOURCES CAN OPERATE PREMATURELY. THE FOLLOWING MINIMUM DISTANCES MUST BE MAINTAINED: • 6" LATERALLY FROM THE SURFACES OF FURNACES, WATER HEATERS AND LIGHT FIXTURES • 1' LATERALLY FROM THE SURFACES OF HOT AIR FLUES, UNINSULATED HEATING DUCTS, AND UNINSULATED WATER PIPES • 1'-6" LATERALLY FROM THE SURFACES OF KITCHEN RANGES AND WALL OVENS • 2' LATERALLY FROM THE EDGES OF A CIELING MOUNTED HOT AIR DIFFUSER, AND 2' LATERALLY FROM THE SIDES AND 3' LATERALLY FROM THE FRONT WALL -MOUNTED HOT AIR DIFFUSERS • 3' LATERALLY FROM THE EDGES OF FIREPLACES (5' LATERALLY FROM THE FRONT OF A RECESSED -HEARTH FIREPLACE) • 3'-6" LATERALLY FROM THE SURFACES OF A WOOD OR COAL BURNING STOVE �I?�14.1b0 � HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Z SPRINKLER LEGEND ..kii)424a+C)2°41S., STATE CERTIFICATION , eesSeW'ler. 1 - I� ' -9030 __ � SPKR THRDS SPRINKLER ORIFICE SIZES AND TYPE UPRIGHT I- z m a W TEE SIZE 2 5 3 7 1 O O 1" 16 8 16 2 SPRAY ee� 3 4 17 32 SPRAY 3 7 1 a,2 t; 8 16 2 SIDEWALL 1" 2 DRY TYPE O O l(�/ 2- WAY TEMP RATING SPRINKLERS I UP AND DOWN J z j m z 3 EARTHQUAKE BRACE Q 165° a acl 4 - WAY EARTHQUAKE BRACE Q 212° 1/2" CO 1" STRUCTURE TO CENTER LINE OF PIPE IN INCHES 286° 1„ 1/2" 350° 1 1" FITTING LEGEND soo° /2" ( 1/2" P PIPE-O-LET APPROVAL REQUIRED F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE - MASON COUNTY TSN THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY • VIKING VK456 CONCEALED RES 1/2" K=4.9 NA IVORY 135E 19 -4)- RELIABLE F1FR REC. PENDENT 1/2' K=5.6 WHT WHT 212T 1 DRY RELIABLE F30R DRY HSW 1" K=5.6 CHR CHR 155E TOTAL 2° QUALITY CONTROL BY MF DATE 4.-`. 4-08 APPROVED FOR FAF.'?ICATION BY DATE GENERAL .NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPUCABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA DESIGNED PER NFPA 13D PIPE NOTES 1. ALL THREADED PIPE TO BE BLACK SCH 40 U.N.O. 2. ALL WELDED/GROOVED PIPE TO BE BLACK SCH 10 U.N.O. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: ASHBEY HOMES 70 WEST VALLEY HTS DRIVE SHELTON, WA 360-427-9487 PROJECT NAME: GRINDSTAFF RESIDENCE SINGLE FAMILY DWELLING 190 NORTH MARDELL AVE HOODSPORT, WA 98548 CHRIS 360-490-9380 PATRIFP099CF pATRIoT E PROTECTION. INC. 2707 70TH AVENUE EAST TEL: (253) 926-2290 TACOMA, WA 98424 FAX: (253) 922-6150 DESIGNER Chris Wilson SHEET DATE 4-14-08 1 0F 1 JOB NO. 14-7303 Vertical Support and Restraint Master Bedroom Master Bath W.I.C. L SHOWER (5 7) Bath 1 I\ Wet Bar Living INIEfiIQ VAULT D f Dining CEILING BREAK LINES -TYPICAL /) / UPPER CABINETS /— / / / / / / / / / I // 1 /4 Pwd. T 1— 7 CLOSET Bedroom ;SD; 5Di Den CEILING BREAK 4 WALL LINES ABOVE Entry Kitchen • 1 1/4 Covered Deck ,DRY Nook UPPER CABINETS 1/ OPEN TO ABOVE Covered Porch IT - AFCON 514 Common Installations r% 0011WM Ts‘o Front Horizontal Stabilize and Restraint AFCON FIGURE 514 — CPVC HANGER FLOOR PLAN 3/4" CONNECTION TO TANK FOR WATER FILL (BY OTHERS) u 5- • I Utility DAYTON 4RJ67 2HP PUMP RATED TO SUPPLY: 40 GPM © 32.9 PSI (WIRED BY OTHERS) Garage 1 SCALE: 1/4" =1 '-0" AFCON FIGURE 515 — CPVC HANGER STEEL CEILING PLATE ALL THREAD ROD ADJUSTABLE RING HANGER CEILING PLATE, ROD AND RING J GENERAL NOTES ALL PIPING IN ATTIC TO BE COVERED (TENTED) WITH INSULATION ALL SPRINKLER HEADS AND PIPING TO BE INSTALLED ACCORDING LISTING. PIPE TO BE SUPPORTED AT 6' o/c MAX. (1" CPVC) WITH WOOD JOIST CLIP, OR JOIST PENETRATION. SUPPORT PIPE WITHIN 6" OF ALL DROPS TO SPRINKLER HEADS. MAXIMUM SPACING OF SPRINKLERS IS 9' OFF WALLS, 18' X 18' AT FLAT CEILINGS. MAXIMUM SPACING OF SPRINKLERS IS 8' OFF WALLS, 16' X 16' AT SLOPED CEILINGS. NO SLOPE TO BE MORE THAN 8 IN 12. ALL PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. SYSTEM HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA MOST REMOTE 2 HEADS. BY OTHERS. TO THEIR HEADER, MAXIMUM SPACING MAXIMUM SPACING 13D FOR THE 11/2"x11/4" SLIP X THREAD ADAPTER 3/4" FILL BY OTHERS 300 GALLON TANK T6R 11/4" CPVC- 1 /2' GRV COUP. 1, 6" ELECTRIC BELL (WIRED BY OTHERS) 11/2" RELIABLE 13R RISER MANIFOLD WITH GAUGE, FLOW SWITCH, AND TEST -AND -DRAIN PUMP PRESSURE SWITCH 11/2" BRASS CHECK VALVE 11/2" GROOVED COUP. B—11/2"x11/4' TxT REDUCER go 640 in —2.0 HP PUMP PUMP & TANK DETAIL NOT TO SCALE FLOW TESTI CHURN: 56.7 psi RESIDUAL: 32.9 psi FLOWING: 40 gpm SOURCE: 2 HP PUMP Cr) SPRINKLER LOCATION NEAR HEAT SOURCES SPRINKLERS MUST BE PLACED A SUFFICIENT DISTANCE AWAY FROM COMMON RESIDENTIAL HEAT SOURCES THAT INCLUDE KITCHEN RANGES, WALL OVENS, FIREPLACES, STOVES, LIGHT FIXTURES, HOT WATER PIPES, WATER HEATERS, FURNACES, AND ASSOCIATED FLUES AND DUCTS. SPRINKLERS INSTALLED TOO CLOSE TO THESE HEAT SOURCES CAN OPERATE PREMATURELY. THE FOLLOWING MINIMUM DISTANCES MUST BE MAINTAINED: • 6" LATERALLY FROM THE SURFACES OF FURNACES, WATER HEATERS AND LIGHT FIXTURES • 1' LATERALLY FROM THE SURFACES OF HOT AIR FLUES, UNINSULATED HEATING DUCTS, AND UNINSULATED WATER PIPES • 1'-6" LATERALLY FROM THE SURFACES OF KITCHEN RANGES AND WALL OVENS • 2' LATERALLY FROM THE EDGES OF A CIELING MOUNTED HOT AIR DIFFUSER, AND 2' LATERALLY FROM THE SIDES AND 3' LATERALLY FROM THE FRONT WALL —MOUNTED HOT AIR DIFFUSERS • 3' LATERALLY FROM THE EDGES OF FIREPLACES (5' LATERALLY FROM THE FRONT OF A RECESSED —HEARTH FIREPLACE) • 3'-6" LATERALLY FROM THE SURFACES OF A WOOD OR COAL BURNING STOVE HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W Y z STATE CERTIFICATION SPRINKLER LEGEND .,. II e `�f• ,' at 4 SPKR THRDS SPRINKLER ORIFICE SIZES AND TYPE x 9 a_ n PENDENT TEE SIZE 2 O CD 1,. 16 8 16 2 SPRAY 1 d 3 4 17 •❑ • 3/4" 32 SPRAY IP11 .. A ye eca`.,°>vSpri3vfth� �f �+bg� (4 �/ b 1 2 3 7 1 a a 1/2" S 76 2 SIDEWALL < , 1„ 1" DRY TYPE O O 1" 2 O . 1" 2- WAY EARTHQUAKE BRACE TEMP RATING SPRINKLERS UP AND DOWN z a 0 z 3 0 165° a = o No a 4 -WAY EARTHQUAKE BRACE 212° 1/2„ () 1" vo STRUCTURE TO CINCHES ENTER IN 286° 1„ ® 1/2" 350° 1" 1- FITTING LEGEND s00° 1/2„ ® 1/2„ P PIPE-O-LET APPROVAL REQUIRED F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE MASON COUNTY TSN THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY • VIKING VK456 CONCEALED RES 1/2" K=4.9 NA IVORY 135E 19 ® R RELIABLE F1FR REC. PENDENT 1/2" K=5.6 WHT WHT 212T 1 <RY RELIABLE F3QR DRY HSW 1" K=5.6 CHR CHR 155F 1 TOTAL 21 QUALITY CONTROL BY MF DATE 4-14-08 APPROVED FOR FAtRICATION BY DATE mmiimmw GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET ND. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION_ 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICADLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROV=D BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA DESIGNED PER NFPA. 13D PIPE NOTES 1. ALL THREADED PIPE TO BE BLACK SCH 40 U.N.O. 2. ALL WELDED/GROOVED PIPE TO BE BLACK SCH 10 U.N.O. REVISIONS 10 DATE BY DESCRIPTION CONTRACT WITH: ASHBEY HOMES 70 WEST VALLEY HTS DRIVE SHELTON, WA 360-427-9487 PROJECT NAME: GRINDSTAFF RESIDENCE SINGLE FAMILY DWELLING 190 NORTH MARDELL AVE HOODSPORT, WA 98548 CHRIS 360-490-9380 n A PATRIFP099CF ChristianWC�pRIFP099 ATRIO1 WWWhPATRI @patrio COM FIREPROTECi1ON, INC. 2707 70TH AVENUE EAST TEL: (253) 926-2290 TACOMA, WA 98424 FAX: (253) 922-6150 DESIGNER Chris Wilson SHEET DATE 4-14-08FP1 1 OF 1 JOB NO. 14-7303