HomeMy WebLinkAboutBLD2005-01253 Addition - BLD Plot / Site Plans - 8/17/2005EXISTING SFL I T LEVEL 1-4OME
I l'-O"
60 5L GI_ DR
EXISTING
PATIO
TRUSS NOTES:
N
N
ALL TRUSS DESIGN AND ENGINEERING
BY SUPPLIER
TRUSS SUPPLIER 15 AUTHORIZED TO
MODIFY TRUSS DESIGN FROM
DESIGNER'S TRUSS PROFILES AS
NECESSARY AS LONG AS BEARING
AND BUILDING STRUCTURE REMAINS
THE SAME
ALL TRUSSES ARE 2"x SET AT 16" O.G.
WITH 1/16" OSB SHEATH -ZING OVER
ALL HANGERS AND UPLIFT
PREVENTION DEVICES TO BE
SPECIFIED AND SUPPLIED BY TRUSS
DESIGNER
O
N
0
N
0
0
'-O"
REMOVE 4 RE -LOCATE
FRAME NEW OPENING
50 5L GL DR
I
r
I
60 50 5LD
N
Z'--Ii" it;
26 FRENCH
1'-q " 10'--1 "
_
wF
ALCOVE
/OFFICE
1'-0" x q'-0" -
in
50 51-FOLD
SNELVING
SUNROOM
101-0" x 01'-0"
J
0
26 BI-FOLD
w
CY
IL
60 B I -FOLD
-
----
CO
-11-1 "
8'-3 "
4"
o
ART STUD I O/I-4OBBY ROOM
11'-o" x 10'-O"
1--1 I
205051-1 60505LD 205051.4
20'-0"
ADDITION FLOOR FLAN
SCALE: 1/4"=11-0"
(2)2x8 DFw2 I4DR
111112x8
ROOF FLAN
tort
r
ir
0
N
0
aw
0
2'-0"
W
O
a n
EXISTING SPLIT LEVEL HOME
11'-0"
N
q Q
k 4 6 " x 24" 1441fLL W/ REBAR
G"x 12" FTGS.'W/ 2 *4 RESAR
a a
20'-0"
*4 ® 24" O.G. - TYP.
® ALL SLAB TO FDN
CONNECTIONS
4GONG.^CONTROL .4,
JOINTS
J
FOUNDATION FLAN
SCALE: 1/4"=1'-O"
l2
-
4
ere
r r r / r r r- r / / f\
r / r / /r
r r /
/
/ / / /
=-1m
U)
PLATE PT.
1
L
CONTINUOUS RIDGE VENT
_ r r e r r r r
1// 1 r r, r f .rl r j_ j/ ./� I
r r / / / / / / / r 1
/ 1 / 1 rr / r / r s / r r
r r / / / ZZZZZZZZZ
r / / r / / / / e / / r / r / /
1 r r r / / / / r 4 / r 4/ r / /
/ / r r / / / r r / / r / r r
//r1 //ere//rr/r/r / / / r ram/
r
/
ROOFING TO
MATCH EXIST.
1"x FASCIA
1"x CORNER TRIM
- SIDING TO
MATCH EXIST.
FRONT ELEVATION
SCALE: 1/4"=1'-O"
ATTIC VENTILATION:
440 SF / 300 = 1.46 x 144 = 211 5.1. / 2 = 105.6 5.1.
REQUIRED UPPER 4 LOWER VENTING
(3) 50 RIDGE VENTS = 150 SQ. IN.
(3) 48.0 5.1. 20" x 6 " SOFFIT VENTS = 1445.1.
RIGHT SIDE ELEVATION
SCALE: I/4"=11-O"
a
W
4'
r
1
J
1
ADDITION: 440 SF
Ui
r-
0
fi
(I)u_ < ?j
zQ
0 z zz U
o
A 0 F vo
Cam W�
a al()
(I
01
z (Nv
4 to
4'
REVISIONS
4'
DRAWN BY: DEK
G-IEOKED BY: del(
DATE: O1/15/05
SHEET I OF 2
SWEET NO.
A 1.0
SCALE: 1/4"=1'-O"
GENERAL NOTES:
OWNER 15 RESPONSIBLE TO PROVIDE OR NAVE OTHERS
PROVIDE ALL ENGINEERING AND/OR SPECIFICATION
AND/OR SIZING OF ALL ITEMS NOT SHOWN ON THESE
DRAWINGS RELATED TO STRUCTURE, ELECTRICAL,
H.V.A.C., PLUMBING, ENERGY COMPLIANCE ANALYSIS AND
OTHER 'SYSTEMS'.
DRAWINGS REPRESENT THE FINISHED BUILDING. DO NOT
SCALE DRAWINGS. BUILDER SHALL BE RESPONSIBLE
FOR CONSTRUCTION METHODS, PROCEDURES AND
CONDITIONS EXCEPT AS SPECIFICALLY INDICATED
OTHERWISE IN THESE DOCUMENTS.
THE CONTRACTOR SHALL VERIFY DIMENSIONS AND
CONDITIONS AT JOB SITE. THE CONTRACTOR SHALL
PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL
PERMANENT CONNECTIONS AND STIFFENINGS NAVE BEEN
INSTALLED.
CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE BUILDING CODES AND STANDARDS. WHERE
THE DRAWINGS MAY VARY FROM APPLICABLE CODES
AND STANDARDS THE MORE STRINGENT PROVISION
SHALL GOVERN.
VENTILATION NOTES:
VENTED WINDOW THROUGH WALL PORTS OR FRESH AIR
DUCTS AT FURNACE.
ALL REQUIRED ITEMS AND EQUIPMENT SHALL BE
PROVIDED AND INSTALLED TO MEET APPLICABLE
VENTILATION CODES.
GABLE ROOF VENTILATION (SECT. 1505.3) VENT THROUGH
GABLE END VENTS, ROOF CAPS OR RIDGE VENT AND
EAVES PER UBC SECT. 1505.3. PROVIDE REQUIRED
SQ.FT. OF NET VENT AREA BOTH AT EAVE AND NEAR
RIDGE EACH UNIT. (1/300 OF ATTIC AREA)
ATTICS SHALL BE PROVIDED WITH A NET FREE
VENTILATION AREA OF NOT LESS THAN 1/I5O OF THE
AREA OF THE SPACE VENTILATED, EXCEPT THAT THE
AREA MAY BE 1/300, PROVIDED AT LEAST 50% OF THE
REQUIRED VENTILATING AREA 15 PROVIDED BY
VENTILATORS LOCATED IN THE UPPER PORTION OF THE
SPACE TO BE VENTILATED; OR PROVIDE A VAPOR
RETARDER ON THE WARM SIDE OF THE SIDE OF THE
ATTIC INSULATION.
PROVIDE WINDOW VENTING OF 1/20 OF FLOOR AREA PER
SECT. 1203.3. PROVIDE NATURAL LIGHT OF 1/10 OF
FLOOR AREA PER SECT. 1203.2. PROVIDE EACH
SLEEPING ROOM WITH AN EXIT OR WINDOW OPENING NOT
LESS THAN 24" CLEAR OPENING HEIGHT PER SECT. 310.4.
FOUNDATION VENTILATION SHALL BE PROVIDED WITH
OPENINGS PER UBC 2306.1 WITH A NET AREA OF 1 SQ.FT.
FOR EACH 300 SQ.FT. IF THE INSTALLED VENTILATION IN
A CRAWL SPACE IS LESS THAN I SQ.FT. FOR EACI-I 300
SQ.FT. OF CRAWL SPACE AREA, OR IF THE CRAWL SPACE
VENTS ARE EQUIPED WITH OPERABLE LOUVERS, A
RADON VENT SHALL BE INSTALLED.
INSULATION NOTES:
ALL PENETRATIONS, OPENINGS AND JOINTS IN THE
BUILDING ENVELOPE SHALL BE CAULKED, SEALED, OR
WEATHER-STRIPPED. WSEC 502.4
ACCESS DOORS FROM CONDITIONED SPACES TO
UNCONDITIONED SPACES (E.G., ATTIC AND CRAWL
SPACES) SHALL BE WEATHER-STRIPPED AND INSULATED
TO A LEVEL EQUIVALENT TO THE INSULATION ON THE
SURROUNDING SURFACES. ACCESS SHALL SE PROVIDED
TO ALL EQUIPMENT WHICH PREVENTS DAMAGING OR
COMPRESSING THE INSULATION.
ELECTRIC WATER HEATERS IN UNHEATED SPACES OR ON
CONCRETE SLABS SHALL BE PLACED ON A FLOOR
INSULATED TO R-1O. WSEC 504.2.1
ALL BUILDING SYSTEMS SHALL BE THERMALLY
INSULATED TO MEET ALL RELATED BUILDING CODES,
ENERGY CODES, AND INDUSTRIAL STANDARDS. ALL
THERMAL INSULATION SHALL BE INSTALLED WITH VAPOR
BARRIER TO HEATED SIDE OF INSULATION.
WHERE INDICATED "R" VALUES VARY FROM APPLICABLE
CODES AND STANDARDS TINE MORE STRINGENT
PROVISION SHALL GOVERN.
FRAMING MEMBER SIZES MAY NAVE TO BE INCREASED TO
ACCOMMODATE REQUIRED INSULATION.
ALL EXHAUST FAN DUCTING SHALL BE INSULATED.
ALL NEATER/AIR DUCTING TO BE INSULATED TO R-8
MINIMUM WHERE APPLICABLE.
STRUCTURAL NOTES:
GRADES AND INSTALLATION OF STRUCTURAL. ITEMS TO
MEET ALL RELATED BUILDING CODES, A.S.T.M.
STANDARDS AND INDUSTRIAL STANDARDS.
ALL "LIVE" AND "DEAD" LOADING OF STRUCTURE TO BE
CALCULATED IN ACCORDANCE WITH I.R.G. REQUIREMENTS
AT TIME OF CONSTRUCTION.
FOOTINGS SHALL EXTEND BELOW FROST LINE OR A
MINIMUM OF 24" BELOW FINISHED GRADE WHICHEVER 15
GREATER.
SOIL BEARING CAPACITY SHALL BE ASSUMED AT 1000
PSI UNLESS ENGINEERED TESTING INDICATES OTHERWISE.
OWNER SHALL BE RESPONSIBLE TO VERIFY SIZES OF
FOOTINGS BASED ON STRUCTURAL LOADING AND SOIL
BEARING.
CONTINUOUS POUR FOOTING/FOUNDATION AT GARAGE
OVERHEAD DOOR w(2) *4 REBAR CONTINUOUS MINIMUM
OF 30" AROUND CORNER @ BRACED WALL PANELS.
MINIMUM 2" THICK CONCRETE AROUND SIDES AND
BOTTOM OF PLENUM BLOCKOUT @ GARAGE FLOOR.
COMPACTED FILL SHOULD CONSIST OF PREDOMINANTLY
WELL -GRADED, GRANULAR SOIL, FREE OF ORGANIC
MATERIAL AND DEBRIS. FILL SHOULD BE PLACED IN
MAXIMUM 8" LOOSE LIFTS AND COMPACTED TO A MINIMUM
OF 15 PERCENT OF THE MAXIMUM DENSITY AT OPTIMUM
MOISTURE CONTENT DETERMINED BY ASTM D-1551 TEST
PROCEDURES.
PRE -FABRICATED ITEMS TO BE HANDLED AND INSTALLED
PER MANUFACTURERS RECOMMENDATIONS.
ALL STRUCTURAL STEEL TO MEET A.S.T.M. A-36.
ALL REINFORCING STEEL TO BE PLACED, SLICED AND
COVERED PER APPLICABLE CODES.
ALL STRUCTURAL WOOD TO BE DOUGLAS FIR/LARCH *2
OR BETTER.
ALL WOOD STUDS TO BE "STUD" GRADE.
OWNER SHALL BE RESPONSIBLE FOR ALL STRUCTURAL
CONNECTIONS NOT NOTED.
PLUMB NOTES:
BATHROOM, KITCHEN, LAVATORY FAUCETS AND SHOWER
HEADS SHALL BE LIMITED TO 2.6 G.P.M. MAXIMUM FLOW.
WATER CLOSETS AND URINALS SHALL BE LIMITED TO 1.6
GALLONS PER FLUSH MAXIMUM WSWGPS WAG 51-18-030.
ALL HOSE BIBBS CONNECTED TO DOMESTIC HATER
SUPPLY SHALL BE EQUIPED WITH BACK FLOW
PREVENTION DEVICES. UPC I103(n)
H0T WATER TANKS SHALL MEET A.S.H.R.A.E. 1OA-8O, AND
BE SO LABLED.
GALVANIZED WATER PIPING SHALL NOT BE USED.
MISCELLANEOUS NOTES:
FURNACES AND NOT WATER TANKS LOCATED IN THE
GARAGE SHALL BE INSTALLED SO THAT NO BURNER,
HEATING ELEMENT OR SWITCH IS LOCATED CLOSER THAN
18 INCHES TO THE FLOOR. UMC 508; UPC 1310(o)
PROVIDE MINIMUM 36" LANDING @ EXTERIOR DOORS NOT
MORE THAN 8" BELOW FINISHED FLOOR.
DOWNSPOUTS TO 4" TIGHTLINE TO APPROVED STORM
DRAINAGE (TYP) CONTINUOUS METAL GUTTERS.
WHEN GYPSUM 15 USED AS A BASE FOR TILE OR WALL
PANELS FOR TUB OR SHOWER ENCLOSURES,
WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE
USED, EXCEPT ON CEILING.
NAILING TO BE IN ACCORDANCE WITH I.R.G. NAILING
TABLES.
ALL DOORS ARE TO BE 6'-8" HIGH UNLESS NOTED.
ALL INTERIOR DOORS SHALL BE UNDERCUT 3/4".
ALL INTERIOR WALLS TO BE 2x4'S @ 16" O.G. WITH 1/2"
G.W.B. EACH SIDE.
SMOKE DETECTORS SHALL BE CONNECTED TO NOUSE
POWER.
25 YEAR LAMINATE COMPOSITION
ROOFING APPLY OVER 15* FELT
OVER "1/16" OSB ROOF SHEATHING
CARDBOARD INSULATION BAFFLE
SIMPSON I-1-1 TIES AT
EA. END OF TRUSS
2x4 SOLID BLOCKING
2x4 SUB FASC I A
4/4x6" CHOICE TRIM FASCIA
3" ALUM. CONTINUOUS SOFFIT
VENTING AS SHOWN
1/2" SOFFIT
CLASS 60 VINYL WINDOWS
IaORZ. HARDBOARD SIDING
ON HOUSE WRAP ON 1/16"
OSB HALL SHEATHING
ON 2x6 STUDS ® 24" OC.
16"x8" GALV. FOUNDATION
VENTS CUT INTO RIM JOIST
1" VERSA -RIM
RIM JOIST
2x6 PT PLATE W/ I/2"xIO"
AB ® 6'-0" OC MAX
ON SILL SEALER
�IIII,III I
7IIIIIIII,,
12"
2x6 DOUBLE TOP PLATE
R-2I INSULATION BATTS W/
POLY VAPOR BARRIER
3/4" TffiG DECKING -
GLUE AND NAIL
— 01 1/2" I -JOIST ® 16" OC -
TYP.
6"x24" CONC. FOUNDATION W/ 1-*4
HORZ. AND *4 VERT. ® 48" OC, ON
12"x 6" GONG. FOOTING HI I-*4
HORZ. AND *4 '' 48" OC VERT.
I I=1 11=1 11=1 11=1 I(=1 I I I I 1_ '" I i
��-i11=1II_II►=1i11�
TYPICAL MALL SECTION
SCALE: 1/2"=1'-O"
(THIS IS A TYPICAL EXTERIOR WALL SECTION
OTHER VARIATIONS MAY APPLY (CCC PLANS)
SIDING OVER
INFILTRATION BARRIER
OVER 1/16" OSB
SHEATHING (TYP)
2x6 TREATED PLATE
ON CONT SILL SEALER
GASKET W/ I/2"xIO"
ANGI-IOR BOLTS 0
6'-0" OC
5/8" x 6" EXP BOARD
4" GONG SLAB SLOPED
R-21 BATT INSUL (TYP)
2x6 STUD HALL O 16" OC
W/ TREATED SILL PLATE
$ DBL TOP PLATES
—1/2" GHB (TYP)
5/8"x4" EXP BRD (TYP)
—*4 REBAR O 2'-0" OC
4" CONC SLAB—
o�v o�u o,-,U oJu oU0
*4 O 2'-0" OC VERT
z_
L
4
•
le
k9
*4 TOP $ BOTTOM CONT N
-�O"c Ovav0vov0 ' SovO ovOv"vOv"`l
000000Quo 00000O0000.
f�n(�Pn( Pnr Pn( `Pn(`Pr Pnl�n
4" COMP GRAVEL
6ml VAPOR BARRIER
R-1O RIGID INSUL
(2) *4 CONTINUOUS
SLAB TO WALL SECTION
SCALE: 3/4"=1'-O"
(THIS 15 A TYPICAL EXTERIOR HALL SECTION
OTHER VARIATIONS MAY APPLY (SEE PLANS)
PRE-ENGINEERED ROOF
TRUSSES C 24" OC
R-38 BLOWN INSULATION
5/8" GWB @ CEILINGS
1/2" GWS C WALLS
R-30 UNDER FLOOR
INSULATION
6 MIL BLACK POLY
VAPOR BARRIER
r
ADDITION: 440 SF
I
7
0
I-
AL()
u
z
9.1- z
0
as
< W
111 to&
n4
I-1---
1
/REV ISI ONS
1
DRAWN BY: DEK
CHECKED BY: dek
DATE: 01/15/05
SHEET 2 OF 2
SHEET NO.
42.0
J