Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2022-01572 CANCELLED SFR ADV2022-00179 - BLD Inspections - 1/25/2024
MASON COUNTY 615 W.Alder St. Bldg 8, SHELTON,WA 98584 I 'I SHELTON: 360-427-9670, EXT 352 COMMUNITY SERVICES BELFAIR. 360-275-4467, EXT 352 Building,Planning.Environmental Health,Community Health ELMA- 360-482-5269, EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/hl, -irl90ection hp Permit Number BLD2022-01572 Date Issued 03/20/2023 fty Project SFR WITH ATTACHED GARAGE Site Address 130 E TACOMNSTEIN C ��D Applicant COMCO TEO LLC UK (�Contractor COMCOR CONSTRUCTION CORP Ilr—� L Contractor Phone 253-224-4172 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST 1-'- <.Ir,1G ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF I AS! i;1 InN. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPFCT1( **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE ',i'.A�dTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUS T tl : MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other Mason County Mason County - Division of Community Development 615 W. Alder St. CANCELLEO Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2022-01572 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: SFR WITH ATTACHED GARAGE ISSUED: 03/20/2023 SITE ADDRESS: 130 E TACOMA ST UNION EXPIRES: 09/16/2023 PARCEL: 322325208013 APPLICANT: HAUENSTEIN LLC OWNER: HAUENSTEIN LLC 14781 HORSESHOE AVE SW 14781 HORSESHOE AVE SW PORT ORCHARD,WA 98367 PORT ORCHARD, WA98367 1.317.697.7553 GENERAL CONTRACTOR'S LICENSE: COMCOR CONSTRUCTION CORP License: COMCOCC922JW PO BOX 702 Expires: 11/28/2024 GIG HARBOR,WA98335 253-224-4172 VALUATIONS: FEES: Paid Due R-3 VB Residential, one- 1632.00 $246,219.84 Plumbing Fees $113.00 $0.00 and two-family Mechanical Base Fee $30.00 $0.00 Covered Deck/Carport 85.00 $1,870.00 Mechanical Fees $92.00 $0.00 U VB Utility, miscellaneous 535.00 $32,330.05 Planning Review Fee $240.00 $0.00 Plumbing Base Fee $25.00 $0.00 State Fee-Residential $6.50 $0.00 Building Plan Review/Change of $125.00 $0.00 Use- Onsite Sewage Building Permit Fee $2,201.92 $0.00 Plan Check Fee $1,431.25 $0.00 Technology Surcharge $77.86 $0.00 Total: $280,419.89 Totals : $4,342.53 $0.00 FIXTURES Qty Mechanical Fixtures Cat Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Bath Tubs 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Clothes Washers 1.0000 Furnace(s) 1.0000 Number of Dishwashers Printed by:Amber Selby on:03/20/2023 09:06 AM Page 1 of 8 Mason County 41 Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01572 (Qty Mechanical Fixtures Qty Plumbing Fixtures 1.0000 Heat Pump(s) 1.0000 Number of Kitchen Sinks 3.0000 Spot Vent Fan(s) 1.0000 Number of Showers 1.0000 Number of Water Heaters and or Vent 2.0000 Number of Hose Bibs 2.0000 Number of Toilets 3.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Framing Inspection Footing Inspection Rough- Plumbing Inspection Foundation Wall-Pre-Pour Inspection Mechanical Inspection Underfloor Inspection Insulation Inspection Shearwall Inspection Connection has been verified by Health or Utilities Insulation Inspection BLD-Final Inspection CONDITIONS " All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. " All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). Printed by:Amber Selby on:03/20/2023 09:06 AM Page 2 of 8 Mason County mp Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01572 * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. * All property lines shall be clearly identified at the time of foundation inspection. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, " WSEC 2015 Certificate"and are available in '/<or'/2 sheets. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Amber Selby on:03/20/2023 09:06 AM Page 3 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01572 " Adopted Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine -4C, Window(Max U- Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. Fuel Normalization Credits: Table 406.2 2 Heat pump Table 406.3— Energy Credits (Single Family) 1.4 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.25, Wall R-21 plus R-4 ci. Floor R-38, Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by15% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.2 Air-source centrally ducted heat pump with minimum HSPF of 9.5. 3 4.1 All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of return duct and 5 linear feet of supply duct connections to the equipment may be outside the deeply buried insulation. All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic. If flex ducts are used, they cannot contain splices. Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area. Air handler(s) shall be located within the conditioned space. 5.4 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or for R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. 5 7.1 All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher—Energy Star rated Refrigerator(if provided)— Energy Star rated washing machine—Energy Star rated Dryer—Energy Star rated, ventless dryer with minimum CEF rating of 5.2, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. * A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. Printed by:Amber Selby on:03/20/2023 09:06 AM Page 4 of 8 Mason County 40 Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O22-01572 * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. Printed by:Amber Selby on:03/20/2023 09:06 AM Page 5 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01572 * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. * WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. Printed by:Amber Selby on:03/20/2023 09:06 AM Page 6 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O22-01572 * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/ Reserve area. * Setbacks are measured from the furthest projection of the structure. * INSPECTION REQUIRED TO VERIFY R4 FOAM INSULATION. PROVIDED INSTALLATION MANUAL ONSITE AT TIME OF INSPECTION. IF NOT PROVIDED INSPECTION WILL RESULT IN A FAIL. * A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2018 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S2 designate TYPE 2, 3, 4, AND 5 WALLS with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Amber Selby on:03/20/2023 09:06 AM Page 7 of 8 Mason County �. Mason County - Division of Community Development 615 W. Alder St. A C Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01572 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herei r no . The gra tin f a permit does not presume to give authority to violate or cancel the provision f any ther st ell )' `iv regulating construction or the performance of construction. Issued B . Contractor or Authorized Agent: Date: p�i�3o sip; Printed by:Amber Selby on:03/20/2023 09:06 AM Page 8 of 8 .0 MASON COUNTY COMMUNITY SERVICES Permit No- bd•(y LP awk,� PERMIT ASSISTANCE CENTER: — ——. •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL 615 W.Alder Street,Shelton,WA 98W4 DEC 2 8 2022 Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone Belfair(360)275-4467•Phone Elma:(360)482-5269 BUILDING PERMIT APPLICATION 615 W. r�iuer Street PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: ]� NAME:Kevin Hauensteln NAME:Robert Rodriguez i 'be. rl� 1.1 itI[M� MAMING ADDRESS:14781 Horseshoe Ave SW MAILING ADDRESS: L C=:Fort orchard STATE:WA ZIP:98367 CITY:Gig Harbor STATE-EA ZIP: PHONE#1:317-697-7563 PHONE: CELL.z53 2za o172 PHONE#2: EMAIL:anothermessage@hotmail.com CM EMAIL:kavin.l.hauenstein@gmail.00m L&I REG# o ZL j aL . I I / 1 PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER[] NAME K*'Nxianwh EMAIL keyin.l.hauensteinOgmall.com MAILING ADDRESS 14781 Horseshoe Ave SW CITY Port o"t"'d STATE WA ZIP 98367 PHONE 317-i7-750 CELL 317-M-7553 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number)32232-52-08013 ZONING LEGAL DESCRIPTION(Abbreviated)UN104Q1AYs NARaoR a troae r♦oo etx:s LOT 13.18 s 5on41 FIRE DISTRICT SITE ADDRESS)OMTacoma Street CITYUnion DIRECTIONS TO SITE ADDRESS ca IS THE PROJECT WITHIN 300 FP OF SLOPE(S)GREATER THAN 14%: YES[] NO r❑ SNOW LOAD:_psf IS PROPERTY WITHIN 200 FP OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW E] ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(.R id m Garage,Commercial Bldg,&c.)Residence IS USE: PRIMARY Ej SEASONAL❑ NUMBER OF BEDROOMS3 NUMBER OF BATHROOMS2 HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Part[sl of Bldg)0 NO❑ DESCRIBE WORK Garage is not heated SQUARE FOOTAGE:(propased) 1 ST FLOOR 1632 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT DECK sq.R COVERED DECK85 sq.ft. STORAGE sq.ft. OTHERIAM f,eII� GARAGES sq.ft. Attached a Detached❑ CARPORT sq.ft. Attached❑ Detached[] MANUFACTURED HOME INFORMATION: *4 CO REQUIRED* MAKE` MOD YEAR LENGTH WIDTH B MS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGEISEWER SOURCE: SEPTIC 0 SEWER❑ / NEW I] EXISTING❑ PLUMBING IN STRUCTURE? YES© NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES© NO[] EXISTING SQ.FT. EXISTING BEDROOMS O PROPOSED BEDROOMS%,3 TOTAL BEDROOMS OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.1 have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void 9 work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICA21ON OF 180 DAY MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) X n re ff ANER(2st�be slaned by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT f v PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH i MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: •BUILDING •PLANNING •FIRE MARSHAL 615 W.Alder St-Shelton, WA 98584 www.co.mason.wa.us Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 • Phone Be/fair.,(360)275-4467• Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Hauenstein LLC NAME:Robert Rodriguez MAILING ADDRESS:14781 Horseshoe Ave Sw MAILING ADDRESS: CITY:Port Orchard STATE:wA ZIP:98367 CITY:Gig Harbor STATE:wA ZIP: V PHONE:317-697-7553 PHONE: CELL: 253-224-4172 2nd PHONE: EMAIL, :anothennessage@hotmail.com EMAIL:kevin.l.hauenstein@gmaii.com L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):32232-52-08013 Zoning:A3 N1-1 unit per.25 acres LEGAL DESCRIPTION (Abbreviated):UNION-GRAYS HARBOR&UCRR ADD BLK:8 LOT 13-16 S 50/141 SITE ADDRESS:xxxx Tacoma street,Union,WA 98592 CITY:Port orchard DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW E_7_1 ADD=AL'I=REPAIR=OTHER=USE OF BUILDING LOCATION OF FIXTURES/UNITS—1 sz FLOOR=2ND FLOOR=BASEMENT=GARAGED OTHER[ PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric=LPGONatural GasE=JDuctlesSbFn Toilets 2 Type of Unit No.of Units Fees Bathroom Sink 3 Furnace T_ Bath Tubs 1 Heat Pump 1 Showers 1 Spot Vent Fan Water Heater 1 Propane Tank Clothes Washer 1 Gas Outlets Kitchen Sinks 1 Wood/Gas/Pellet Stove — Dishwasher 1 Kitchen Exhaust Hood Hose bibs Dryer Vent 1 Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE. PLICATION. X Sign ur of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JSN I 1 NC T 47 EL 1(o• r -;il EL PRESC"siP'VE FLAW.DIZFROLAdJa"JRES ARE TO BE DESIGNED BY UC£NSED INDIVIDUALS � c�eii� � � • 'gib- IAW VATH APPLICABLE LICABLE TALE AND COUNTY ODES. _�_ ��� ` 1 � • PROPER rY FWN,Et NOTE, u� I Carektlty review ALL aspects cLs of this septic PROPOSES the C t d i. .. t�'EmVm AJW toss incarred due to changes to I is es^n alte ssu #issiorrto1 P13OPOJSE i£ �? oddly li�lth DeWur 3-B R HOUSE Ali are tne sole respons9hihty of the property owner, � �I DRIVE AY i Yarae r c t - - cd y ."#1+`ex. ..'.isreo*r#rP.crt.Su.o-�.r-.iwarees "T ,1 uPSi 1 4 $1; $ { j rsa 1�.�j t` I J— .1 V�' i 5 `:�i ! Y L{ s`fT4_ Tu FEu C6 -0' EL 1 T IF O r1 r n - T ( 1 ' ---------------------- NOBUILD ZONE _-', I � ►_ �' �; r r AV SL4 1 -- ,._.."-"�." ` • 1 ` it; DSH RESERVE . 113l' t -2.':REDW WO SW LWIN WTHLOTS OF P93ES ow# at - APPR <. j Tj a r +5*EL A 0 III »' _... ICI2o U I� I�• �g 5 1 V 30 50 75 s n P 1 P- F-BLWRR USE SIEMENS PANEL �C�QEL ##LF R ALL f>RG7J=',rFR7-Y LIN4E7.S/a0�UA{1�)ART_S "A VIETSCALE (FEET) `(�' �" E3 N L_)lje 0A1,S7-F?A C.) f3-Y 'T'J s 0 V^lkFr-'('S) AJVC G3#�'c TH,E_IR 1� ,EJ t7"(...a•')• � S�.. ALE (F E I "SM. 'f`At_LE.Fa`. MI,J-.�T V+F RI'.F'Y THA"Y"w�.T�.s�.d..1NYw to Cw CATlC1N Q.T Tlfi71E. C9� ilW'.�.TA[_L R/{>*�."1"S"s` At...L G+CY C� «�'.ItiS ETGiA.0 K'F'w- � -IT {S Ti--4 R$SPQ'T�I2r1..iTY Gf= QWi+.iER7Ri=•.r='R1W. .ti,�.r.ETr1'*3G dsE.tVT T e=f2 G'�V_f PTA T-G?RL^.r+..'i f!".i v✓1=L#TiKG. f„[C�Y'X X r�aR,+i✓.Y�'T'r`d�rGqVh.yNiNS"[:i?.I.��N.,,iT+�r Cv.Ht_�tLIE"..t,TtfifrL�.3:S#?i=N.N�C.J'C�!>~"LrM fNA..tE:te-s,:1T.L.*T..r T�G£.c'-Sr Rri.V Q.4$'Nkt'1 tB�Apt7-V it�X+.?�r=i:.s�Ki•1ArVE:N.4FC'•?fi f SaS�tr-TS Ef3TRliJC S(7LL-. LC -r lmmpc `,J"J=r•.rr`r=, -r"i LEGEND E E - w - -£-FzC�-f- .C-r t-r;Zir.n<,..r4y A,.rir rats 6vrL.0 zt}rtE ACME DESI N °,�ATf4N�,,3�C7rtS E7R 84._l.R NiNCa L"3Y'+r LSf�A-3 rd f=9�Lt�. �* m �V3 f8.¢T��„q`:tl#Yifl('b� �y �/a }T-s,�{^{f �♦y,^��{1y� �^�yr{/��rr€��� C.7 L.»TG LdiV�G)K�s.. �. h: w'AT R'X'A6l.E'S. A GL3 F2TAiN G',a R./+..tN >v1..r4W eE: r-i. Ci LJIF2.ES:S. r AT L. E1J1.A .0 iA\1. L..V S P.O� BOX 2954 t?EP�.fi.i C?3NC+1J�G"ti FTINAL 3w 1_�.'L`�..TJ{?N�. A.RL.dlu'IP Mh"Y' E!!= R��t LD9 Fi�::�- & -7t �53 aC�.t, ry/���,7{ ` C:,�K?ti'a'NSCst.1'!"It+F2A 1*`.ff.T.EfR,e®,WAY i=2:Q irsS C?f .r�,.i:w.e f=1�LC?>�..Y2' ,�..�a, ' I J �.sJE��./ .ii..f.�t •''^ '.�'3.._T-i iM.ES Y •' ( t:f+ NAME— J� LLC L�j r {CT�f'''t}�} t'� f/t NCI tom' LF+.."T'Ef2.Af_T.3 Oil AJSGC�V LE:...s P>.R EPtZ✓'.TE=Gz< TP^4EY . FQ! Ai�P�t C'�..?u..e 'tATc AFa E? MA^e' VARY. .': j�jj ME- SIL ffE t4..ALL_F 4'1't"`,. P i�^.:C3ViCS C?YMrwY ttErd4. Jr4 fN"r'Yi r F:t.tied E=d.'1'�Cl rDr-Xw�L�F*.. d 1 �y Q/��j',� .__ -__..............._ ..., ,.,..»,.m..r_.....»... J L3..}4.7�.: %"r>'t-41" 'i 00 r±m -yr f=Rod . se�urac a i e i ss+v r� nr sr sc �vrs [200 c>rz cs.� T wasv Rs. ( CL:.; G?UT yg� 1'-�5 sue{�/ }+��+Jy �(}.i}�r .S;C E3sT ir,=>fk r"E=- R:SAL_.:^c,;1 i�AP NT=,NT. &.L-.,,.tic-4:TtC"_ C_"^�:J N44'��.7N�:rtiT.a tk+t t•i�T F.3�.\.+U..�..TE RTdC3H'7`T'cz, �LJR W:F^�E:,. TAX ID— 322,32"V.i.-0801 w.p,,rEfze Ljr 4a ?At,4_S-r as A M. T-fir✓•r_JM C)W rta< 1=fRcsne r i y s��Z i� G ns Y o v r.T_ t --TRASH TRAP srx nEirc rrA iY i�dCsa �.s rinLlcestr ni =Lxr rv+s eG C Utz aIrr cs�7 .cr t caysna s-t rr rniriri.iLsnn c»= c sf r + C is i i5> L ?e+E xt s-s i rs. A" t DEVICE STREET- E TACOMA STREET crys =_CsvaFZ EL. 360.y7Q84 8 Ca E. ra z�isv c_^: C.sr,t C>=..t.Tt� Vffic-M. .^_rm.t,.$a-a-r; *.r nnr.:•,- aE t .Gc .�.s3rx :o. ( =I.,2`�§d'�l.PUW TANK _-- �.>_ ,� CLQ SE.R T,-.t .r,f Q� :> 1-1E �, 1�: SALE: 1"=2Q' SITE PLAN INF00a, �C�{ ES ��'��C.�� .f.° - ire vu,�.TE.d2 sk.rwC+.aE'wE~•.rz. L€^J CCz Yv`.. .. < '�-£-ewr• ew tJ s~+-r aE. cc.rv.6-rFr._s -t- `J t.ow�,:-r-,a-r as.. COI..l rv'"r•v" C.c9.::sE.... _.. _ RmM MAW H _ . s r Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Building s X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = —Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name TI(f.U�{'1`�'(�{ rL- Parcel#,t2,3a-52--061 BLD# 2.02.2-_01 s-72- Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: htty//www.co.mason.wa-us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) &-The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:(360)-427-9670 EXT.450 Mail:P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670,EXT.352 Mail:P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St,Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that information provided is accurate and employees of Mason County are granted access to the above- ', describe rty Kfor7rXed inspection as m -required. X Owner/Agent/Contractor(circle one)Date: 3 xJ Page 2 of 2 I PROPERTY: 10994 SF BUILDING COVERAGE: 2167 SF DRIVEWAY Q COVERED DECK: 85 SF CONCRETE PATIO: 152 SF - d xxe:r.w DRIVEWAY: 295 SF 0 FOUND W REBA�wTHI REMNANTS OF DID CAP. TOTAL COVERAGE: 2699 SF = 24.5% COVERAGE M PLACED CAP ON RE '77 AS IT RT P09TION EH APPROVED 23 N WOff 09'w Rh--Thompson 02/21i2023 b 100. bI b I W�in� I -71/2' r------------- --.--__- EH Setbacks S1 A.) Drainfield/Reserve requires 10'setback from footing/foundations I I I U B.)Septic tank(s)requires 5'setback from all footing/foundations R I PROP. 3 EIR I z C.)No foundation/Perimeter Drains within 30ft,downg radient of I I W ti Dr ainfield/Reservearea $_ RESIDENCE I N� D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of DrainfieldrReserve area L i PARCEL NO. : r-:- , 2B-r b 32232-52-08013 I" ' $_ , NOTES: 12 1 IN-Or ' 1.THIS IS NOT A SURVEY. ALL PROPERTY LINES/BOUNDARIES HAVE BEEN DEMONSTRATED BY THE OWNER/AGENT. D 2.SEPTIC/SEWER SYSTEM DESIGNED BY OTHERS. 1 3.IF EXCAVATION ENTERS 10.BUFFER TO PROPERTY LINE THEN SILT FENCE TO BE 17-10' I I O O b'• INSTALLED. 4.CLEARING LIMITS TO BE CLEARLY DELINEATED USING FLAGS OR FENCE. '♦D-6 1 2' I I $ ® / I I D a IV NO BUILD ZONE N I � 71 iz rrt 94 100% o RESERVE On - q' 0, $ N W02'n9'III IM.00 PAC T o. 000 X _ ALLEY ND FENCE i P/N 322325208013 140 W-8.4 UNION, WA 98592 sP1 NAME: HAUENSTEIN LLC 21 20 19 18 17 SPI w I PHONE NO.: (253) 224-4172 SITE PLAN 1;jGI PROPERTY: 10994 SF 02/16/2023 BUILDING COVERAGE: 2167 SF #UV2022-00179- 10' Min DRIVEWAY APPROVED COVERED DECK: 85 SF - - - _ _ MASON COUNTY�DCP P ANNING CONCRETE PATIO: 152 SF �C01T i:.UQY,, DRIVEWAY: 295 SF - �A�E,'„-' _ COVERAGE O FOUND " REBA(i WITH] TOTAL COVERAGE. 2699 SF 24.5 REMNANTS OF OOOLLLDDD CAW C7 co PLACED CAP ON REBAf� Z o AS IT FIT POSIT] N00 �3 EH APPROVED 23 7 i N 88'02'os" w Digitally > C7a� Rhonda Thompson 02/21l2023 100.00 i signed �o Scott Reedy by z w Front - / - o � Scott r ------------- — 27'-2" I Ruedy 01 N M EH Setbacks S,' D � I w I I A.) Drainfield/Reserve requires 10'setback from footing/foundations i PROP. 3 BR I U H B.)Septic tank(s)requires 5'setback from all footing/foundations C.)No foundation/Perimeter Drains within 30ft,downgradient of Z,) N ; RESIDENCE w� Drainfield/Reserve area N I CA D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within I °° 50ft,down gradient of Drainfield/Reserve area c L, PARCEL NO. I ~ f I f 28'-1" I 32232 52 08013 o Z �ADV2022-00179- WWI NOTES: I I I 13'-0• 12 I 1. THIS IS NOT A SURVEY. ALL PROPERTY LINES/BOUNDARIES HAVE BEEN I I DEMONSTRATED BY THE OWNER/AGENT. Rear I I m I D 2. SEPTIC/SEWER SYSTEM DESIGNED BY OTHERS. I I O Front 3. IF EXCAVATION ENTERS 10' BUFFER TO PROPERTY LINE THEN SILT FENCE TO BE I I n INSTALLED. 17'-10" I O 4. CLEARING LIMITS TO BE CLEARLY DELINEATED USING FLAGS OR FENCE. I 3 10'NO BUILD ZONE o I z FT rT11 RR 2.5 Zoning RESERVE a0 z Front Yard Setback. 25'. _ U' M o x -u Side & Rear Yard Setbacks. Residential dwelling rAiNwiEwb.,,, 40, D. 1 x oN and accessory structures is 20'. � w oar N 88.02'09" W U I "v OR 10% width of lot if not more than 100' wide j ° o OR approved ADV X — A[Rbbr I I �0 1 I ND FENCE REVISIONS ' p DATE P/N 322325208013 140 W - 8.4 2'6 I SHEET NUMBEUMBE R UNION, WA 98592 pi NAME: HAUENSTEIN LLC 21 20 19 18 17 SP1 OF PHONE NO.: (253) 224-4172 I SITE PLAN t r MASON COUNTY Mason County Permit Center Use: COMMUNITY SERVICES ADv 2o2Z -Dot� `1 Building,Planning,Environmental Health,Community Health 615 W.Alder St a—Bldg.8,Shelton,W 98584 Date Rcvd a Z�-Z Z- Phone:(360)427-9670 ext.352♦Fax:(360)427-7798 Fee: $130.00 Request for Administrative Variance for Reduction in the Required Setbacks For administrative review,the minimum variance on a setback request is 5 feet from the side yard lot lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction requires a standard variance. Setbacks are measured from the fiirthest projection of the structure, including roof eaves and gutters. Applicant/Owners: ACt- o r)'M L1 Mailing Address: I�A 7`['� I D r���Y�IU Z ';� E -"Au City - b[�F'1411G�. State: LOA Zip: Cl Q�3l0 I Telephone: 5317 - (091 • -155 3 Email: i n. (. Ltd C.Z ryAtL'. If this reduction is tied to a building permit, please give permit case number. � BLn 2..c2Z. - 015•�1� Parcel Number(s): 3-1,a 5d, UP-6 1.3 Zoning Ili Site Address: ' EC6M A fTe-L t" l "')1 10A- Requested setback variance: ft. ❑ Front Rear 1?(Side I(� ft ❑ Front Rear ❑ Side Z ;� ft. ❑ Front ❑ Rear ❑ Side ft ❑ Front ❑ Rear ❑ Side Front Setbacks-From access easements and road right of ways. Minimum 10 feet. Rear Setbacks-From the rear property line. Minimum 10 feet. Side Setbacks-From the side property line. Minimum 5 feet except for certain shoreline designations. An illustrated site plan is required. Your site plan must show the following: north arrow, abutting street or easements, and set backs to all property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and driveway. Show all proposed new development. I I i r FRONT AND OR AR REDUCTION RE VESTS: For existing lots of r s of March 5, 2002; You must meet one of the following: 1) One of the following exists on the lot(check all that apply): ❑ a) steep slopes, wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ ) lot width at the front yard line of no more than 50 feet; d) lot size of no more than one-fourth acre; e) existing improvements of buildings, septic systems, and well areas. SIDE REDUCTION RE VESTS: Fore sting lots of record as of March 5, 2002; You must meet one of the following: 2) One of the following exists on the lot(check all that apply): ❑ a) steep slopes,wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ c) lot width at the front yard line of no more than 50 feet; �d) lot size of no more than one-half acre; e) existing improvements of buildings, septic systems, and well areas. Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard for Rural Residential 2.5, 5, 10, or 20 zones. Of 1 z 4,, - ,J 01 Owner/Agent(please indicate) �— Signature Date Official Use Only ,N Approved by: � Date Denied by: Date Reason for denial: