HomeMy WebLinkAboutMiles Sand Gravel Addition Alarm - FIR Plot / Site Plans - 1/5/2007Symbol Legend Make / Model No. Qty. Li 4-6 N2.2 r:?EOL EOL F.c�7` any •110cd LD F•; H H 45 • D&F• D&FI 4-3 D&F' D&F {D28`F2 (H (H Fire Alarm Plan 1/8" = 1' - 0" NEW SHOP From FACP D&F 110cd N1-4 EOL North EXISTING 1-1 035 H o-C2 03-4 O o-E N1-2 75cd S o-C2 2-1 EOL 60cd 01.3 0-A2 1-2 1-4 Efil F - ---• -�-- EOL Building Data ADDRESS: 3100 W. Franklin St. Shelton, WA 98584 TAX PARCEL NUMBER: 420242400180 CODE: 2003 International Codes with Washington State Amendments (WAC 51-50) IMC 2003 UPC 2003 WSEC 2003 WSIAQ 2003 TYPE OF CONSTRUCTION: V-B OCCUPANCY: Existing- S-1, M New - S-1 BUILDING AREA: Existing - 3,200 New - 3,200 Total - 6,400 SF Vicinity Map 1235m_' 1160Oft 06 Yahoo! Ow Wire Legend A ZONE #1 (2) #18 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) B ZONE #2 (2) #18 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) C ZONE #3 (2) #18 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) D ZONE #4 (2) #18 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) E N.A.C. #1 (2) #12 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) F N.A.C. #2 (2) #12 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) G DOOR RELEASE CKT. (2) #18 AWG. FPLR (FIRE RATED SOLID COPPER CABLE) Zone Descriptions 1. OFFICE DETECTION. 2. OFFICE ABOVE CEILING DETECTION. 3. EAST SHOP DETECTION. 4. WEST SHOP DETECTION. 5. -10. SPARES. DEDICATED 120VAC CIRCUIT FOR PRIMARY POWER SILENT KNIGHT 5208 10 FIRE ALARM CONTROL PANEL BATTERY BATTERY 12 VDC 12 VDC 12 A.H. 12 AM. Riser Diagram 14:411zR-ct Rd �Ft3�rrd to I_ tAilSeqflgt Aim Shalton-_MaRd: .�r Sequence of Operations SMOKE DETECTOR HEAT DETECTOR MANUAL PULL STATION SYSTEM TROUBLE AUDIBLE & VISUAL ALARM INDICATION @ FACP / ANNUCIATOR LCD DISPLAY • • • ACTIVATE NOTIFICATION DEVICES TRANSMIT ALARM SIGNAL TO CENTRAL STATION AUDIBLE & VISUAL TROUBLE INDICATION @ FACP / ANNUCIATOR LCD DISPLAY • TRANSMIT TROUBLE SIGNAL TO CENTRAL STATION • ACTIVATE CLOSURE OF COILING OVERHEAD FIRE DOOR • • • TO ALARM CENTER, INC. FOR UL CENTRAL STATION MONITORING RELAY OUTPUT#1 COILING FIRE DOOR RELEASE RELAY OUTPUT #2 (SPARE) RELAY OUTPUT #3 (SPARE) RELAY OUTPUT #4 (SPARE) STROBE SYNC. MODULE 01 8 800 [ I [ ]N.A.C. #2 N.A.C. #3 (SPARE) N.A.C. #4 (SPARE) N.A.C.#1 FACP FIRE ALARM CONTROL PANEL SILENT KNIGHT 5208 1 0 PHOTOELECTRIC SMOKE DETECTOR ESL 429C 3 0 135° RATE OF RISE HEAT DETECTOR EDWARDS 281 B-PL 10 194° FIXED TEMP. HEAT DETECTOR LOCATED ABOVE CEILING EDWARDS 284B-PL 1 I� MANUAL PULL STATION wall mount @ 48° A.F.F. to bottom of device SILENT KNIGHT PS -SA 4 HORN / STROBE COMBINATION wall mount @ 80" A.F.F. to bottom of device cd = candela rating of strobe light GENTEX GEC3-24WR 5 xxcd STROBE LIGHT wall mount @ 80" A.F.F. to bottom of device cd = candela rating of strobe light GENTEX GES3-24WR 2 WP8xxcd 10" BELL WITH ADJACENT WEATHERPROOF STROBE LIGHT wall mount @ 12' -0" A.F.G. to bottom of device cd = candela rating of strobe light BELL MBA 10--24 STROBE GENTEX WGES24-75WR 1 1 0 JUNCTION BOX N/A EOL INDICATES END OF LINE DEVICE N/A N/A Flag Notes CONNECT COILING OVERHEAD DOOR TO CLOSE UPON ACTIVATION OF GENERAL FIRE ALARM. ALV13 k,1 l e__- : _ r-N 646_ t fe_r- N r P'Pr 72- G d- .1) c- 4-k ns�c_L�c��i'oY1 e_cl--? ALL APP-;CA-_- CODES SHALL AP i.Y.. L_ V.Tt Mlle PROJECT NAME: Miles Sand and Gravel Building Addition 3100 W. Franklin St. Shelton, WA 98584 DATE: 12/11 /06 SYSTEM TYPE: FIRE ALARM AND DETECTION DRAWN BY: J. FOSSETi SCALE: AS SHOWN CONTRACTORS ALARMCIO55CW LICENSE NO. DATE REVISION DATE APPROVED BY: REVISION A ACE ACE FIRE & 1-800-354-1555 SECURITY SYSTEMS A DIVISION OF ALARM CBTIER. MO PO BOX 3363 - LACEY WA 98509-3363 SHEET NO. FA7 1 of 1