HomeMy WebLinkAboutBLD2014-00006 Sprinkler - FIR Plot / Site Plans - 3/3/2014GENERAL NOTES 5W-0" ,2'-O" 44-8' 14'-6" 16'-0' T 1" _ _ T-1" 4'-6" 4'1" 6'1" 5'-S" • N To r- 2-8 ` 9-0 L_- ; rl_ BA MA •I 1 . 'r. 1 r I -014 Ti 1 GREAT ROOh1 /4-412 VAVLT VAULT COIN CELNG .4 /\ N.I.C. P & S WARDROBE ti BEDROOM CV t2 8-6 BLAZCMASTER® PIPE DIMENSIONS SIR 13.5 (ASTM r442) INC-rS (MI IMrTrRS) NOMINA SIZr AVrRAGr 07 AVrRAGr II D0..N)S/CT. 3/4" (20.0) 1.050 (26.7) .874 (22.2) .168 1" (25.0) 1.315 (33.4) 1.101 (28.0) .262 134" (32.0) 1.660 (42.2) 1.394 (35.4) .418 134" (40.0) 1.900 (48.3) 1.598 (40.6) .548 2" (50.0) 2.375 (60.3) 2.003 (50.9) .859 214" (65.0) 2.875 (73.0) 2.423 (61.5) 1.257 3" (80.0) 3.500 (88.9) 2.951 (75.0) 1.867 6'-6" _ _ 4'-1" 11.-0" 911 ■ 1� BATH 'W1°' 110 -war {1Rua tY-143'2"I"1!PAN Ti '� 0- Oh 1A si eY 2 DtN 5 N® 61 / E-592 ' - ENTRY 1: 1.1 to S-1" 1�\ 7-0" OFFICE 1 6-0 DINI G COVERED DECK /01412 II 01412 KITCHEN UTILITY • ROOM 1-2 21'-6' 1r-6" 5'11" 3 CAR GARAGE • 1: 31. >I -1" COVERED CONC. PATIO 16'-O" 2' 25'-O' 12-O' 34'-O' 37-0" 71'-0' SRiUCTURE BEYOND S' ` sPF ..,id 1111 1 1 ' 101 4/1‘ • immix i3 g 4 T86 OS8 aoi. R- 1/2' TA .13MS,8' o.O ROM MARRON LPL R-30 R-49 ATIC NALATIQI 5/8' BEDROCK C L 3/4 TM OM SUEROOR-; 912'A ROOFNG 1 RULING PAPER 7 G' o.S3 9CA291 SIRUCIURE BEYOND l i A I ir1 1 I A /r4r1 1 A 1 1/ 11 1 1 14 A I i 11 A n i l \° 'r 444 0A44444gr0a4r14\\,/hgl/1AgR4A,114O0JITATOMTlry' O' BASE FISCAL MOISTURE BORER O1 MUD NERLR BEANS i' POSTS (-0. DC n e '2'1m' FOm16S DBet MI int WIN (2) N ILL MBAR SUN vs- SIEKIIIS REED IRE (h BUILDING CROSS SECTION SIMULAR Am-`===== 1/4' - T-0' B LAZEMASTER0 PIPE SIR 13.5 (ASTM r442) -ANGrR SPACING NOMINA SIZr inches (mm) MAX S°ACING 'ee, (m) 3/4" (20.0) 5.5' (1.7) 1" (25.0) 6.0' (1.8) 114" (32.0) 6.5' (2.0) 1" (40.0) 7.0' (2.1) 2" (50.0) 8.0' (2.4) 234" (65.0) 9.0' (2.7) 3" (80.0) 10.0' (3.0) CLRE TIMES WITII ONE STEP SOLVENT CEMENT 200 psi (MAXIM...) TrST °RrSS..Rr DID SIZr inches Ambien. Tempera.ere 7 ering C ere Period 60'r .0 120'r 40'r .o 59'r 0'r ,0 39'r 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 114" 1.5 hr. 16 hr. 120 hr. 114" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See No.e 1 21i" 8 hr. 72 hr. See No.e 1 3" 8 hr. 72 hr. See No.e 1 No.e 1 ror ,here sizes, .he solven, semen. can be applied a. ,empera,ires below 32'r, however, .he sprinkler sys.em .empera.ire m as. be raised .o a ,empera,ere o' 32'r or above and allowed .o sire per .he above recommenda.ions prior .o press are ,esing. WATER METER CFTY MAIN LOCATION Q SYSTEM RISER UNDERGROUND DETAIL CHANGES SUBMIT CHANGES FOR APPROVAL PRIOR TO PERFORMING WORK ALLOWANCE FOR FRICTION LOSS IN C PVC FITTINGS (EXPRESSED IN EQUIVALENT FEET OF PIPE) FITTING PIPE DIAMETER 3/4 „ 1 " 1 1" 11r4" 2" 2 1" 3" TEE BRANCI- 3 5 6 8 10 12 15 TEE RUN 1 1 1 1 1 2 2 ELBOW 90' 7 7 8 9 11 12 13 ELBOW 45' 1 1 2 2 2 3 4 COUPLING 1 1 1 1 1 2 2 MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM TAB LE 1 MAXIM...M S..°PORT S°ACING 7ISTANCr rNI INr S°RINK cR -rAI 7R0° r 90W Dior sac inches SYSTrM °RrSS..Rr < 100 psi > 100 psi 3/4" 9" 6" 1" 12" 9" 1 X" 16" 12" 1)¢"-3" 24" 12" TAB LE 2 MAXIM..M S..°D0RT S°ACING 7ISTANCr IN INr S°RINK cR -rAI IR0° Ter olor SIZr inches SYSTrM DRrSS..Rr < 100 psi > 100 psi 3/4" 4' 3' 1" 5° 4' 114• 6' 5' 1)4"-3" 7° 7' Pion -ANGrR (C 0Sr TO Trc) C rl LNG r1Rc S°RINK rR r OOR, CPVC IRO° r]Rr S°RINK rR ASTM r442 C °VC -9RANC- INr' W007 ,.0I.STS • NSr INTrRNATIONA A°D40VrD r0R ..Sr WIT- °OTA9 r WATrR CLRE TIMES WITI I ONE STEP SOLVENT CEMENT 200 psi (MAXIM..M) TrST °RrSS,.Rr Dior SIZr inches Ambien. Tempera.ire 7uing C ire Period 60'r ,o 120'r 40'r .0 59'r 0'r .o 39'r 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 1X" 1.5 hr. 16 hr. 120 hr. Cr 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See Noss 1 214" 8 hr. 72 hr. See No.e 1 3" 8 hr. 72 hr. See No.e 1 ror ,heee sizes, .he solven. semen, can be applied a, empera.eres below 32'r, however, .he sprinkler sysem empera,ire mis, be raised ,o a ,empera,ere o' 32'r or above and allowed ,o sire per ,he above recommendajons prior ,o press are ,es,ing. 4 1 ea nesesucnom D A 1Lt A = (D-8")+B A (D-203mm)+B s D 30" s D 762mm SOFFIT FORMULA 1.OPVC ADAPIEt � 1" Sr -k-cy Yb ° F c- 1- G (( 1"PPE ?PPE Heed Box 001DiE3CTIMORE DETECTORS TO FLOP/SWITCH FOR/LAM 1"PPE��' 1' RAD1ffi0W DEVICE AID• 1"COPP9LADAPIER Fish Flow bl I CRAN NORCO FIRE PROTECTION POINT OF CONNECTION DRAW TO ARIE MINCE OFMIM D= RISER DETAIL soli HMV' 1. System to be designed to N.F.PA. #13D, 2010 edition and Fire Department requirements. 2. System hydraulically calculated to Fire Departments requirements and to N.F.PA.13D and Manufacturers Requirements. 3. Minimum pipe size cleated be 1" throughout Job. 4. System to be hung per manufacturers requirements. Avcon Hangers to be used - Fig 511 & no block & head set 5. All underground piping to conform to local Water Department requirements. Ns Is for fill line only 6. Water Information to be provided by pump manufacturer. Source of water by owner. 7. Transition from underground to riser to be copper type K typical unless noted otherwise 8. Risers that are exposed are to be PER CPVC LISTING. Risers that rise up in wall to have typical access panel, provision of this panel to be per contract 9. All electrical wiring and conduit for electrical switches to be by others. 10. Cleaning and painting of pipe to be by others, if required. 11. All drilling and notching to be per manufacturers specifications and Fire Department requirements. 12. All piping to be CPVC typical unless otherwise noted. 13. Items to be verMed at time of inspection: 1Pressure at base of riser Sprinkler head location and spadng. Heads located from heat zones 14. Alarm bells to be located per Fire Department requirements. 15. Testing of system to be per N.F.PA. #13D and Fire Department Requirements. 16. Sprinklers may be omitted from closets less than 3'06 In depth or not over 24 sq. tL Srr TA9 r 9r OW rOR N..M9rR 0r-ANGrRS RrO..IRr7 ASTM r442 C °VC 9RANG - INr' MINIMLM ALLOWABLE IIANGERS °rR rNGT- Or DIDC Dior SIZr inches pipe eng.h 1 -anger 2 -angers 3 -angers 3/4" 0'-0" TO 5'-6" 5'-7" TO 11'-0" 11'-1" TO 16'-6" 1" 0'-0" TO 6'-0" 6'-1" TO 12.-0" 12'-1" TO 18'-0" 134" 0'-0" TO 6'-6" 6'-7" TO 13.-0" 13'-1" TO 19'-6" 1)4" 0'-0" TO 7'-0" 7'-1" TO 14.-0" 14'-1" TO 21.-0" 2" 0'-0" TO 8"-0" 8'-1" TO 16.-0" 16'-1" TO 24'-0" 234 0'-0" TO 9'-0" 9'-1" TO 18.-0" 18'-1" TO 27'-0" 3" 0'-0" TO 10'-a" 10'-1" TO 20.-0" 20'-1" TO 30'-0" NSr INTrRNATIONA AD0ROVr7 rOR ..Sr WIT- °OTA9 r WATrR CLRE TIMES WITII ONE STEP SOLVENT CEMENT 200 psi (MAXIM..M) TrST °RrSS.Ar Dior SIZr inches Amblen. Tempera. ire 7 ring C are °eriod 60'r .o 120'r 40'r .0 59'r 0'r .o 39'r 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 1 Xa" 1.5 hr. 16 hr. 120 hr. 134" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See No.e 1 2)¢" 8 hr. 72 hr. See Noe 1 3" 8 hr. 72 hr. See Noe 1 No.e 1 ror .hese sizes, ,he solven, semen, can be applied a, ,empera,eres below 32'r, however, .he sprinkler sys.em empera,ere mis. be raised .o a empera.ere o' 32'r or above and allowed ,o sire per .he above recommendaions prior .o press ire ,esdng. 2 HOLE OFFSET HANGER AFC'ON 511 PIPE HANGER SIDE MOUNT KILT> IMIld CAIEWI HEIL A>!lROVAL& SAI000LLama IIMIKW/ .OALV♦!®yCJeBOYI/111101ITWIOL. CPJrC VIM WM ♦ 1 C MA III (IV S 11+! 11123 11D6 11111 i' 214. 111/14law f 11AP 4SYIP 1101 1215 MA 114' 47/1 2SW 111Hf 7 A NIP 17141 MN O r OWNER INFORMATION NAME ED SCOTT ADDRESS 140 N JESSIE COURT HOODSPORT, WA 96548 PHONE FIRE DEPT INFORMATION NAME MASON COUNTY ADDRESS 426 WEST CEDAR STREET SHELTON, WA98684 PHONE 360-427-0670 WATER DEPT. INFORMATION NAME OWNER TO SUPPLY P/T ADDRESS PHONE WATER INFORMATON STATIC 00 RESIDUAL 68 GPM 50 METER SIZE NIA souRcE PUMP FROM WELL BUILDING INFORMATION SQ. FT. 2033 S.F. TYPE Wood Frame OCCUPANCY Residential LEGAL DESCRIPTION TAX ACCOUNT # 42201-78-00070 FIRE MARSHAL VINCINITY MAP N WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Edwin P. Cogar 4295-0499-CG Level 3 Norco Fire Protecti. , I NORCOFPI J • NO SCALE N Wfi tif - 2' 4' 6' 8' 10' 12' 14' 16' 18' NOTES REVISIONS SPRINKLER SYMBOLS SYMBOLS ® SYSTEMS RISER o RISE UP • DROP DN 2 WAY EARTHQUAKE BRACE 4 WAY EARTHQUAKE BRACE GROOVED COUPLING \#0i. HANGER TYPE AND O UPRIGHT HEAD 0 PENDENT HEAD 1' WALL HEAD WAHEAD LEGEND OA UPRIGHT OVER PENDENT 25 PIPE SIZING 1 HYDRAULIC CALC NODE REVISION NUMBER E❑ BRANCH LINE NUMBER LOCHTIONTND WELD TAG NUMBER DATE DESCRIPTION BY 9 SYM CNT 17 NAME CONCEALED METAL WHITE TEMP 160 4.9 NPT 1/2' ❑RIF 7/16 MFG, RELIABLE MODEL* RFC49 ESCUT C❑NN. Defau it/ ,-.c,\\\)\ , I ORC Fire Protection, Inc. PO Box 363 Ravensdale, WA 98051 425-432-7250 SCOTT RESIDENCE 140 N JESSIE COURT HOODSPORT, WASHINGTON CONTRACTOR: NORCO FIRE PROTETION, INC. PIPING PLAN AREA 1 PERMIT NO. CONTRACT NO. N13094 APPROVAL MASON COUNTY DRAWN BY ED COGAR SCALE 1/8" = 1'-0" DATE 3/3/14 REVISED PLOTTED FP1of1 /Z2..c/-'7L - 00 7 D 6 LD26)/ 4' Oe cola