HomeMy WebLinkAboutSWG2023-00469 - SWG Application / Design - 10/30/2023 MASON COUNTY 415 N 6TH STREET.SHELTON,WA 98584 SHELTON:360-427-9670.EXT 400 l BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00469 APPLICANT PETERS RODNEY B & SHARON L Phone: 360-701-7592 Address: 160 W OLD OLYMPIC HWY OLYMPIA, WA 98502 OWNER PETERS RODNEY B & SHARON L Phone: 360-701-7592 Address: 160 W OLD OLYMPIC HWY OLYMPIA, WA 98502 SEPTIC DESIGNER PAULA JOHNSON -Arrow Septic Phone: 360-898-2255 Designs Inc. Address: 171 E VUECREST DRIVE UNION, WA 98592 Site Address: 11 SE Jainee Ln Primary Parcel Number: 320267590061 Permit Description: 3-bedroom OSCAR X02 system w/OS-50 coils Permit Submitted Date: 10/30/2023 Permit Issued Date: 11/06/2023 Issued By: David Anderson Current Permit Fees Paid: $780.00 (additional fees may be required upon installation of system). Permit Expiration Date: 11/03/2024 (based on date of inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF 055. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental)onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. 4 _. OFFICiAL U ()NAYOr 442, - MASON COUNTY IEIP ) 0 - 30 - 1.3 4 �? N 0 COMMUNITY SERVICES .1 � At- tri I' CAC,, �O,3 VUFI N Itl, C is rl h .nm:HeaRM M o SWGQOZ � - oo 1 , °z N ON-SITE SEWAGE SYSTEM APPLICATION E A m n APPLICANT ON- m Rodney Peters (360) 701-7592 z MAI INGPODPESS-STREET c-.ALAlp ZIP 160 W Old Olympic Hwy Olympia, WA 98502 m 11 SE Jainee Ln Shelton, WA 98584 I `o NAME Tr'DGONER 1`LO E 1N Arrow Septic Designs, Inc (360) 898-2255 WMEOF:NS-ALLEN o I C y N AMIN:,AP-ER PE IYI E p a CC -eq' s L.,.. O RE 'DENTIAL OSS COMMUNITY OSS hOOMMER IAL OSS �Ln�PR '1DVDUA WELL 6 PRIVATE TNO'ARTY 3EL_ Z 1 � STRUC 0 PUBLIC WATER SYSTEM TYPE Of N tLhEN CONSTRU„TICNIUPGRADES REPAIRIREPLAC,EMEN'� S ._., r_ � 0 TABLE IX REPAIR ! -..4 O ,LEA El SURFACING SEWAGE XISTING FAILURE 0 SHORELINETAWU CD Spi.DESIGN FORM(REQUIRED) SEPTIC DESIGN;48 JI II_. C ,' - = Icn i 6 WAIVER;BI(:=AFPLICABL, i 2 --> 3 2 acres S co DIRECT!OFF-o SCE ANDS`E CO`YJIT ONE (Fr'taan wax) Start out going south on N 4Th St toward W Cedar St. Take the 3rd left onto W Railroad I O Ave. Turn (R) onto S 1St St/WA-3. Continue to follow WA-3. Turn left onto E Arcadia Ave. E r I o Arcadia Ave becomes SE Arcadia Rd. Turn right onto SE Binns Swiger Loop Rd. Stay o straight onto SE Fireweed Rd, turn R onto SE Jainee Ln. Destination 1st house on (L). I a) SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. CFFKIAL USE ONE. -HIS LINE- -_ - JI'CRAOE?FAILURE SOURCE am repAs'e9 P.. ses 0 VOLUNTARY Q MAINTENANCEPUMP'I.NG ❑BUILDING PERMIT O:TOME FAI F ❑COMP INT C0 ".ER. INS._CTCR SOIL LOGE .,..MM1I_M1SCOWIdVc 7111 : 0 - NII 6/ L5 bsd- di+ 7 f'- 1-7 S1odrdmj woke- TO 7 ; 0 - Zg" (1I,5#- cS'- Gl iv/ 541C&11G Ina fr_.#/• l` ✓vf '4p "i ✓ SOIL CODES p A„ VERY G=ORAX o, S-SAND L=_GAM S=SC' EFOL ,_n=_ ROOTS di/ NAPE APPL ON acPPO,EDe ISSLED BY :RE 11/3/Z073 'I ll/5/207 y / T ///6770-1 0,t THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Ms-DIA7--CS DESIGN FORM-PAGE ONE Assessors Parcel Number: 3 2 0 2 6 - 7 5 - 9 0 0 6 1 A design will be reviewed when 3 copies of each of the following are submitted: "Completed design form that has been signed and dated. " Scaled layout sketch, including all applicable items on checklist "Scaled plot plan.including all applicable items on checklist. r Cross-section sketch. including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site. Maximum paper size' I i' X IT' u PARCEL IDENTIFICATION y� Permit Number: SWG 2 )73- 16? ___ Designer's Name: Arrow Septic Designs, Inc Rodney Peters__ Designers Phone Number: (360)898-2255 Applicant's Name: __.--_ -- e 171 EVuecrest Dr :Nailing Address: 160 W Old Olympic Hwy _ Desi_sner's Addass: -- Oi mpia, WA 98502 Union, WA 98592 City State Zip City State Zip DESIGN PARAMETERS Treatment Device ❑Glendon Biofilter ❑ Sand Liter 0.Mound ❑Sand Lined Droinfield ❑ Rocimulming Filtes lO pe: gAerobic Unit Make Model OSCAR X02 0 Disinilimon Unit Make Model Other: Drainfield Type fat}-Gni 0tC ❑Gravity g Pressure 0 Trench ❑ Bed g Sah Se.fi ._Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 ✓ Schedule Class Netatim .42 gph Daily Flow:Operating Capacity 270 gpd Length 25 }t Daily Flow: Design Flow 360 gpd Diameter .66 in Septic Tank Capacity(working) XO2 in exist 1,200 gal - Number 6 Receiving Soil Type I1-6) 3 Separation .5 ft Receiving Soil Appl. Rate 0.8 gpd/ft_ Orifices Vs Required Primary Area 450 ft` Total Number of Orifices 50 X 6 = 300 Designed Primary Area 450 fe Diameter emitter in Designed Reserve Area 450 ft' ' Spacing 6 in Trench/Bed Width 10 ft c Manifold Trench/Bed Length 45 ft ,- Schedule.Class 40 Elevation Measurements Length 45 ft Original Drainfield Area Slope 0 ro Diameter 1 in New Slope. if Altered 0 ,o Preferred manifold configuration used? fid Yes ❑No Depth of Excavation UP-Fare — in Transport Pipe from Original Grade 40 oo�.rslop.- - in Schedule/Class Designed Vertical Separation 20+ in - Length 30 ft Graveness Chambers Required? ❑ Yes it No ❑Optional Diameter 1 in Pump Required° BS Yes 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdosesiday 411 Duff in Elevation Between Pump& Uppermost Orifice 6 ft Dose quantity .89 gal Drainfield Squirt Height:Selected Residual (head) - ft Chamber Capacity (flood) New 2-comp- 1,000 min gal,- Uppermost Orifice g Higher 0 Lower than Pump Shutoff Pump controls:Please check those required. Capacity(o?Total Pressure Head 6.2 gpm gmimer gElapse Meter I 'Event Counter Calculated Total Pressure Head 6.69 ft If Timer: Pompon 30 sec ,Pump off 3 min Comments • DESIGN FORM-PAGE TWO Assessor's Parcel Number 3 2 0 2 6 -- 7 5 — 90 0 6 1 Permit Number: SWG — DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch O Test hole locations g Drainfield orientation and layout Reference depth from original ade: g Soil logs fi'?J drench/bed dimensions and g Septic tank critical distances W ithin layout 1 Draintleld cover 66 Property lines 1 Existing and proposed wells g D-Borg Valve box locations Reference depth from original grade within 100 ft of property fiii Septic tanklpunrp chamber and restrictive strata: gi Measurements to cuts. banks.and locations V Laterals, trench/bed,top and surface water and critical areas fi7j Obsmanon port location bottom O Location and orientation of V Clean-out location 0 Curtain drain collector curtain drain and all absorption g Manifold placement 21 Sand augmentation components 1 Orifice placement Other cross-section detail: lid Location and dimension of [i1 Lateral placement with distance gObservation ports/clean-outs primal} system aid reserve area to edge of bed Other Information 64 Buildings gVud.hl ivisua al referenced Yes No • Direction of slope indicator 54 Scale of dra t n on scale d 0 Design staked out g Waterlines bar r 0 g Recorded Notices attached 12 Roads, easements.driveways, • 'r} 0 g Waiver(s j attached parking , i t* 91 X g ❑ Pump curve attached g North arrow and scale drawing r. C1 0 Evaluation of failure soaans rly itt shown on scale bar /t P.AULA JOY JOHNSON '•�e,� Non-residential justification �- P. f61:T 5fG' " 'l) 0 &I Waste strength 3a1 . 0 d Flo DESIGN APPROVAL The undersigned designer must citified by installer at time of installation g Yes 0 No Signature o esigncr Date n t The undersigned has revietsed this design on behalf of Mason County Public Healthpsnw_ryprrrq?I�e�°ifto be in compliance With state and local on-site r ° 1lal ions: [ ° 2p23 1116/ZazS Noy °E Environmental I lcalth Specialist Date ,crti r o f -`031 CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION` The design is 'tamped "Approved' by Mason Counts Public health.✓ the Onsite Sewage Permit has not expired,the Permit Expiration Date is: ii /3/?0 t - ✓ Drai nfmld site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12.7/2013 Arrow Septic Designs 171 E. Vuecrest Dr. Union, WA 98592 October 27,2023 Mason County Department of Health Services 415 N 6th St Shelton,WA 98584 RE: Rodney Peters Property (Parcel #32026-75-90061) Septic Upgrade Dear Inspector: Attached is a repair/upgrade septic design for a property located at 11 SE Jainee Ln, Shelton, WA 98584. The existing septic was installed in 1994. The 2-bedroom septic consists of a 1,200-gallon 2-compartment septic tank, a 400-gallon pump chamber,a 10' x 25' sand filter and a 22' x 83' mound drainfield. At a recent service, it was discovered that the sand filter is clogged and had been overflowing. The pump in the sand filter basin is operational and the mound drainfield is functioning. A previous permit SWG2022-00353 was approved for the rebuilding of the existing 10' x 25' sand filter. That permit has since expired. A new owner has purchased the property and since the septic needs repaired,they would like to go ahead and upgrade the septic to 3-bedrooms since that is the actual size of the house and what the assessor has on record. To upgrade to a compliant 3-bedroom septic,the following is required: • Abandon/decommission the existing sand filter. • Abandon/decommission the existing mound drainfield. • Ensuring the existing tanks have risers and lids to the surface. • Add an OSCAR X02 kit to the existing 1,200-gallon 2-compartment septic tank. • Add a new OSCAR XO2 control panel. The existing panel may be used on-demand for the lift pump. • Add a new 1,000 gallon minimum 2-compartment dosing/pump chamber with headworks. • Add a new 10' x 45' low-profile OSCAR mound drainfield. There are no wells within 100 feet of the drainfield and we have also designated a full reserve drainfield area. The property owner's contact information is as follows: Rodney Peters 160 W Old Olympic Hwy Olympia, WA 98502 (360)701-7592 If you need further information,please contact my office at(360) 898-2255. Sincerely A,l ULPA gle�y, � e ter Treatment System Designer N"5'- FJwRESUUIt r fp Di 2 to ul Stara 8C3II NM MYOt1s • I 6� V1N*Val IN 1r'- tj t, v "-• MTN WM 0 W CO () 0 r \ — N 4= o f N •• In 9 p I !; vu �, 9 \ � N"O3 1.j o oU o `�i • z z `� s ��i Z050 V] V< I ri iY I : ��� / nF U'trawl F kJ 14 ++ A • I \ ...1 1 aaEn ti r'7a•' CC I �L / / z N - 1 �A' Z O - < W4 • 9 �1 2 Z ccz oN I 3 . Ira c� UZ IW -7 W3 m lk A. � W F• %IJ. q la j 1�1,t, F V1Z I I w L� NIZ y o- Q�\�; 3 Z 5kb6ea z m . QJ z and _/,/ F oo Z OZ //y V nie•Ill -12 x m 4 x < N C IC �� Fa a� Ey wLM .F 14i. 4t (1. NO V 112923 9E9 .11 67% 1' Sin ',ACC --"`71 -;, h�h,r,- Al ri Li • 3e&11 IVs_y_i rIN Audio-Visual Alarm-Upgrade to OSCAR XO2 Panel L\ _-Ves \-..-e -Q Cleanout - 0- 2W ii G.-LSt0-MokS .. 0Existing 1200 Gallon Septic Tank S. 2-Compartment with S1. 1), , LS W( Q""' Effluent Filter-Add risers &XO2 L Kit . tS v ' Z- 0-30 fs S ' � O Existing 400 Gallon Pump Chamber Ili 3 Existing Primary Mound Drainfield - to be abandoned\decommissioned O6 Existing 10'x 25' Sand Filter- to be 'I abandoned/decommissioned I_� ONew 1,000 Gallon 2-Compartment Dose/Pump Tank with Headworks ,`i WE,-.C• OS Airbox-Place at higher elevation than tank lids T 5ka�a r s Ti, . Iv .0 A. < /0 O \ l 4�*• '�°g/.+'d„r / �- 0 Zo 4o b< 0�.1 /xc; 7- o V S20 2� tix \ C ✓ �_/ 02- �0' Sc- �Cc P l.oi- man $Fz--- \ cj'�'i 'ua.^c 32cz-6-7S-,a061 /f i` SE \ tis t.E Lv,_ . Lacy la.s. fit, d • it - s'tuias l� �AVLA JOT JOHNSON'; 4411 OSCAR-XO2 at-grade drip design calculations Friction Loss Calculations: F = L(Q/K)?85 F=friction loss through pipe in feet of head L= length of supply line in feet Q= Flush GPM K=47.8 (1" sch 40 PVC pipe) (Table 2) Hydraulic Layout'05-50 coils' Design Flow Total Coils #of lots Coils per lot Dose GPM Flush GPM Excess TDH. 1240 4 4 1 1.4 7.8 50' 1 300 5 5 1 1.75 9.75 �-._...._.50 '1360 6 3 2 2.1 6.2 50' 1450 8 4 2 2.8 9.2 50' 480 8 4 2 2.8 9.2 50' 1600 10 5 2 3.5 11.5 50' ' Coils must be arranged in a single line F= 30 (6.2/47.8)1 a5 F=0.69 Total Design GPM= Flush GPM =6.2(from chart) Total Head = Friction Loss+Elevation from Pump Tank to OSCAR Coil Drainfield Total Head =0.69+6= 6.69 (6.69< 50'excess TDH-OK) Factory Timer Settings: 1,440 minutes per day/411 doses per day=3.5 min per dose cycle{incl. on & off) From Factory: 30 seconds On&3 minutes Off G o�� � f tz .;WA. r .fill.kh frilly it /u LA /1123 oY5J V j�' PAUU JOY JOHNSpN'; LICENSE l SOME . OAS�Z'rctCES )i� SSc 5 otll OSCAR at-grade drip drainfield design calculations Basal Area Calculations: Base Design Criteria: 360 gpd design flow, soil type 3 (0.8 gpd/ft2),flat site (<5%slope) Basal area required =daily design flow:soil loading rate 360 gpd+0.8 gpd/ft2=450 sq.ft. Coil length =6 coils @ 5' diameter(6 x 5'=30')with 18" coil spacing 5 x 1.5=7.5' =37.5' Minimum shoulder width @ 6" (2 x 6" = 1')= 1' Minimum side slopes at 1 : 1 slope @ 6" (2 x 6" = 1')= 1' Minimum basal area length =coil length+shoulder widths+side slopes=37.5'+ 1'+1'=39.5' ...use 45' Basal area width= required basal area a minimum basal length =450 sq.ft. =45'= 10' Basal area dimensions=45'x 10'(450 s.f.) Media: OSCAR drainfield: ASTM C-33 sand media: as per Washington Department of Health's Recommended Standards and Guidance for Intermittent Sand Filters. Supplies/Control Panel: • OSCAR XO2 Control Panel: The LF1P-RF-AR or ARA control panel shall be used to operate the timed dosing sequencing of the OSCAR-XO2. Timer settings for the OSCAR-X02 are short and very frequent(3 minutes off and 30 seconds on). The supply line needs to drain between doses, so the "on time" may need to be increased to compensate for filling the supply line prior to each dose. Each OSCAR-XO2 unit will include: $yt�(\� 1, • LF1P-RF-ARA control panel ate g, • LOT-30, 1/2 hp, 120 volt pump ."a ••• { ,44 1% ' G, V � 6 2023 • Hi-Blow Aerator, HB-80 (80 liter/minute) }+ ; o' • Hi-Blow diffusers • OS-50 or OS-100 Coils • PVC fittings and drip tubing adapters c Crc)c"HSEfi1fESIGNER' • HWN-.7-RF automatic headworks •- 1-"-¢o9/t5 • Solid inches poly tubing for connections • 2 float switches ttl Headworks: HWN-.7-RF • %inches Arkal disc filter, mesh, 130 micron • % inches Arad flow meter • Three oil filled pressure gauges (0-100 psi) • 5 Netafim normally closed solenoid valves (Model 80) OSCAR Cover Options: There may be a desire to cover the OSCAR with something additional to the specified ASTM C-33 sand. The intent is not to have too much additional cover over the final C-33 sand layer. Placing too much cover will inhibit plant root growth. Because the C-33 sand is sub-surface irrigated, grass and other ground cover will grow rapidly,forming a firm protective cover over the OSCAR.At the end of the first growing season the C-33 sand layer will be as firm as native soil to walk on. Cover Options include: • Landscaping jute mat with grass seed or ground cover plantings • Thin layer of mineral soil low in organic content(<10%organics) • Thin layer of crushed or washed rock for wind erosion protection • Thin layer of bark or wood chips Do Not Cover C-33 Sand drainfield with: • Organic mix(manufactured top soil from compost) • Filter fabric OSCAR authorized dealer supply kit contact info: • H.D. Fowler, contact Jacob Gober or Dennis Groff, phone: (360)459-7300 • Ferguson Waterworks (Silverdale) contact Zach or Daryl 360-697-1510. • Iconix Waterworks,(Tumwater)office (360) 539-7518 C*) s k Ji` gi"'@ NOV 0 6 2023 C C. O. - a. /y/ uMUM 0 Nna O 2 w 1 t C # a � N � 1f IL 41 H141M 1VStl9 NOV 0 6 2023 I en ni N O ZI < 1 a tri H 0 5 Al q,. �. eu,.. � AA w«. .bv ... =. �' aVA i - ,. � ad 1 SI a aIk � .�1x •t ' 1 V k` . li ". YA. C ... ^tiYe#ti'F.--r2 1/4.,, ,,,-. COro X ,tia',_ c /ism ° y tiiI.II d w + 7' pt 3 O o y > it Q .W, s �4 i _ - h a 1 _IL ai CZ j g o u V X U W U-�UUJ �f r _ tee+, _ 6 ` N p N cei 1 ' I I" H ., . d° w II m 0 C' o NOV 0 6 2023 gs6-ll X02 Tanks in to • t.�It= 9• •k� �..: • f000 GA= t000 Gallon • tcItale in to • omit l jAim 5—.L .1 rar Treatment tank Discharge tank Introduction: The OSCAR-X02 treatment system is comprised of two systems: the X021a septic chamber, aeration chamber, clarifier, and pump chamber) and the OSCAR: coils, C-33 sand, reverse flush headworks, and control equipment. Wastewater-is collected in the septic chamber where gross solids are separated.The waste stream is aerated in the aeration chambers.Aerated effluent passes though the clarifier then into the pump chamber. The expected waste strength will be 30 mg/I CBODS and 5 mg/I TSS. Effluent is dosed through a 120 mesh disc filter to OSCAR coils,installed in ASTM C-33 sand. Effluent discharged from the coils is treated by the sand prior to infiltrating into the receiving soil. Final discharge is expected to reach 2 mg/I CBOD, 1 mg/I TSS, and 36 FC/100 ml of effluent, meeting Treatment Level A. The X02 tanks can only be used with OSCAR coils. . re, 4A y+^�,� NOV 062023 El Design: The single family residence packages are designated as: OSX02-240, 0SX02-300, 05X02-360, 05X02-450, 05X02-480, and OSX02-600 and have the corresponding design flows of 240, 300, 360, 450, 480, and 600 gallons per day. The OSX02-240, 300, 360, 450, and 480, are standard packages. Design flows greater than 480 gallons per day are considered custom and will require design assistance from Lowridge Onsite Technologies, Inc. For the standard single family residence OSCAR-X02 package parts list see the appendix. The X02 can only be used with OSCAR coils. All tanks must be approved by Washington Department of Health. An OSCAR-X02 is two technologies combined together as one. The system can be designed in increments of flow up to 3500 gallons per day. The OSCAR has different sizing criteria than the X02. The X02 is designed in increments ranging from 500, 750, 1125, 2250, 3,000, to 3,500 gallons per day (see Table 1-2). The OSCAR is designed in increments of 62.5 or 125 gallons per coil per day, depending on coil model (see Tables 2 and 3). Consequently, a design for a 7 bedroom system (840 gpd) would incorporate a 1125 gallon per day X02 plus 14 05-50 OSCAR coils (875 gpd). X02: Treatment Tank: The partition wall between the first and second compartment of the treatment tank must have a 4 inch by-pass hole or the bottom of the tee baffle located between 40% to 60% of the liquid depth. Discharge Tank: The patrician between the first and second compartment of the discharge tank must have a 4 inch by-pass hole located at least 18 inches above the floor of the tank and no more than 27 inches between the bottom of the by-pass hole and floor of the tank. Recommended hight is 18 inches, if possible. Table 1-2 '' 660-670 330-340 660-670 330-340 80 Vm 7514Pd 1,000 500 1,000 500 120 Um or more 1125,11Pd 1,500 750 1500 750 180 Vm or more 3.000 1,500 3,000 1,500 360 I/m or more gpd 4,000 3,000 4,000 2,000 480 I/m or more -$±i�O d 4,500 3,000 4,500 3,000 560 I/m or more r NOV 0 6 2023 11I-1 n 4 c; SUBMITTAL DATA SHEET Thermoplastic Reinforced Thermoplastic motor bracket and dischargewith built-in.guise bearing This 1/2 HP pump has a stainless steel top bearing and motor coupling.These are assembled witr our F.Y. McDonald sta mess steel motors Two wire single phase models include pump. motor, and 10 lead. This four inch submersible's suopl iec with vaunted leads meeting the National Ele vicar Code(N.E.0!specifications. The performance curve below will assist you in choosing the pump that meets your news. A MODELS E-306PM CX) 7 '.,'. E - 30 GPM B 300 alma Wi 112 HP 122 FT • 53 PS.I. E 200 — ` Flush ws 6 too —1/2 HP•4 SMAGES• - - - - - - `Dose Simplex 0 5 10 15 20 25 30 35 40 Duplex 0 10 _..20 30 40 _.. 50 60 10 BO Fourplex 0 20 40 60 80 100 120 140 IGO FLOW GPM Specifications Model HP Material Volts Phase A B Wt. LOT-30 1/2 Plastic 115 1 T09: 9.53 2_ SUBMITTAL INFORMATION i.. - Stainless steel pump shell and pump shaft Powered by AP McDonald saomersble motorsl2 HP. - Reinforced Thermoplastic diffusers and impellers - I I S FNPT Discharge - Thermoplastic intake screen and cahle guard NO-LEAD:The weighted average of toe wetted surface of this ao-lead product con ma en oy consrna hie water:artacs less:ran one quarter or one percent(0.25%) lead. POW Bite e Onsite Technologies,Inc- Fax Free . 3E-H75-fl823 ae ai[CT' on h:om PLake Stevens1179 Fax 1 o Sac ao?2 os a sl e cam Lake Stns.WA 98258 AY McDenalaonsider 93 irorrazco or tdrs assemely dra. n; when purls.;ad ter-an any asl lad ssp€oiic D]ect Tao;� hi notice. Submitted by: , ' r' ' ;q i' t i-1 Novo 6 2023 _. ?RI N L HEALTH n i A /\ \ J I a_ >f__ 0 j 0 LL a. Ni V u ~ oN 2 2 = O t ro gm 1— cc c Pc) LL $ g _ I- o\ ce pT * urn NOV 062023 13t-1 Panel Wiring Diagram Model LF1P-RF-ARA 9ek Woe From Main Power Panel Quote 01 3023DC3 120VAC,10.60 Hz Men disconnect t.1 provide by others. GND SOI PUMP 1.2 LI ® 410 200VAC IO N ® C6 20A ® ------ • L4Hp 1.3 = t 4 From Main Power Panel 120VAC,10.60 Hz. Main disconnect provided by others. 1.5 GND 1 BLOWER 1 6 LtN ILI ♦ '20VAC'0 N 1:1 CE10AEf ♦ LH„^ S 6 BLOWER 1. ♦ 1/CFp 1.9 1.10 2LOWER 20VAC10 1/OF: • 1.11 • 1.12 GND LI m 1.13 N m 13 CONTROLS CB10A LOGO BASE :.IS ® ® LOGO SIEMENS 6ED1052-1 FB0&fi2AI 1.16 'igh LevelAlarm 1.17 Timer/Redundant Off I --0 00 1.113 1.19 corn El-'-� F'---� ❑' 1.20 NOV 0 6 202R 1.21 Push to silence 13 1.22 1.23 HAND PUMP I SEMICONDUCTOR 01 OFF eo MOTOR CONTROLLER1.2E F =. _ SIEMENS 3RE2150-19A22 1.25 1.26 EDWWD-OEMM: Rev.1.0®d}pg120i Page 1 of 1.4EIV�p r1 2.1 HANG 22 VALVE Vt(51,S2) OF, $2 RELAY 02 !DEC 2.3 o RJ9S-CL-A120 -so L4 VALVE V2(33 54) RELAY 03 �.� S1 )DEC 25 I Io RJ25CL-A120 26 wm VALVE VS(55) RELAY J o RJ2S-IDEC 04 CL-A120 I .] 2.3 2.9 000 EXPANSION LOGO EXPANSION DM8 2.10 I O Q SIEMENS 6EC1C55-1F500-0BAZ 2.11 01 ALARM LIGHT 212 I '— _(05) D2 MVO SERIES 213 AUDIBLE ALARM ® . FLOYD BELL SP-'061 214 REMOTE ALARM ® - ° !. a (AHw OR EOWV. 120 VAC ALARM) 2.15 1.5 2.6 TRANSFORMER 216 S goal CL2M24 120V-24V 7 12 40VA 21] FUSE 2A ill _ 6 20mm CR'. 219 I d rv/C Imo( Comm" 24VAC VALVE 51 I�1 VALVE PROVIDED BY 0-HERS 2.20 1I1II II 221 MC 1.1 Cpn.ma SOLENOID VALVE 52 1E1 1 24VAC VALVE _ PROVIDED BY OTHERS 222 FINN CS2 2 23 I1< El'. n2 1i1 Ccnmx. 4 24VAC VALVE LVE SS PROVIDED BY OTHERS 2..24 111111)1! 225 NC I-I Co.nimon SOLENOID VALVE So 101 • 20VAC VALVE PROVIDED BY 0-HERS 2.26 II I.N CR3 2.2] N/C an Ccmm� SOLENOID VALVE S5 A ® MI 4VACVALVE _v , ) L PROVIDE]BY OTHERS 2.20 Flail NOV 0 0 2023 Rey;1110 L9"RO Page 2N eV 3.1 Control Panel Connections 33 4 4 4 4 Q 4 V1 V2 �3 Q 3.4 { � • 3.5 l•' High Level PSwitche 51 53 St • 4- i i i Nam Timer/ Recurcant Off e Q 0 } 3.9 } 3.10 0 0 311 L 4 Discierye 3.12 3.13 3.15 3.15 3 17 3.18 3.19 3.20 321 3.22 3 p33 A 3mJ' �j '71•`f� 3.24 NOV 062023 3.25 CIA ,n�Iv7A1.HEALTH 3.25 3.27 EDW.WO.0EN1: Rev.1.0 ma ym9120: Page 3 of ~�l G 'Y1h �1,40?, ammo Septic DeyigiwA.., vt. OSCAR X02 Pretreatment q ; „0o„y . LNSTALLATION& MAINTENANCE >nuu JOY JOHNS 'yt OSCAR At-Grade Drip Distribution Systems I.I -ptl moor canes >t i- E 1. Installers must attend OSCAR X02 training and be certified by Dave Lowe at Low Ridge Technologies(www.lowridgetech.com) prior to installing this system. 2. Installer must review OSCAR X02 installer manual prior to system installation. 3. OSCAR X02 supply kits are available through LowRidee Technologies approved suppliers only. 4. The Treatment Tank and Discharge Tank must both be 2-compartment, State approved and sued per the OSCAR X02 manual and the onsite wastewater treatment system designer. 5. OSCAR Sand media must meet or exceed ASTM C-33 standards. 6. Install drainfield level with contour of the ground. 7. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 8. Tanks must have risers to the surface as required by Mason County to ensure easy access for future operation and maintenance. 9. Headworks must be in boxes accessible from the surface for future operation and maintenance. 10. Ensure any trees and shrubs are removed,grass is cut short and then scarify surface of ground in drainfield area to prep for drainfield. 11. Ensure 6"minimum cover sand media over the drip irrigation tubing. 12. Install audio/visual high-water level alarm. Redundant off switch not required. 13. Flow inducer tube or block are not required for the pump, it can sit on bottom of tank. 14. Install return line from headworks back into the tee outside the inlet of the treatment tank. 15. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 16. Divert all storm water runoff and house downspouts away from on-site sewage system. 17. No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 18. Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 19. All materials and workmanship must meet County and State regulations. 20. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 21. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 22. All transport lines under driveways or parking areas must be encased to prevent crushing. 23. The tanks are to be protected from vehicle traffic or traffic-rated tanks may be used. 24. The drainfield is to be protected from all vehicle traffic or other damaging factors that could compact or disturb the soils. 25. The preferable cover planting for subsurface drip is turf or grass, or non-invasive groundcover plants. It is recommended to install an optional jute mat upon completion of the drainfield to prevent erosion and then seed with grass immediately. Other options include a thin layer of mineral soil low in organic content(<10%organics)and grass, a thin layer of crushed or washed rock for wind erosion protection, or a thin layer of bark or wood chips. 26. Do not cover the drainfield with organic mix(manufactured topsoil from compost)or filter fabric. 27. The homeowner should ensure no vehicle traffic, roto-tilling or digging in the area of die drip field to prevent damage to the drip tubing. Also, invasive plant species should not be allowed. 28. Home/property owner is responsible for all property lines,corners,surveys,encroachments, etc. 29. Owner Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required QPeratic & laintennance. NOV052023 MASON cou5 T Y E NVP,ONMEN T AL HEALTH