Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2023-00372 - SWG Application / Design - 9/6/2023
MASON COUNTY 415N6T"STREET S"ELTON,0, 0 SHELTON:360A27 7W EXT EXT 4 4000 ♦, BELFAIR:360-275-4467.EXT 400 ;. Public Health & Human Services ELMA.360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00372 APPLICANT EMPIRE HOME CONSTRUCTION LLC Phone: 1.360.751.1745 Address: P 0 BOX 241 KELSO, WA 98626 OWNER GULBRANSON ERIK& JENNIFER Phone: Address: 120 LEMIEUX LANE SE TENINO, WA 98589 SEPTIC DESIGNER PAULA JOHNSON -Arrow Septic Phone: 360-898-2255 Designs Inc. Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER Allan Kirk-MASON COUNTY Phone: 360-426-0574 EXCAVATING INC Address: 30 E WILCHAR BLVD SHELTON,WA 98584 Site Address: 560 E LAKESHORE DR EAST Primary Parcel Number: 220175000045 Permit Description: New 3bd ATU to pressure trench Permit Submitted Date: 09/06/2023 Permit Issued Date: 10/04/2023 Issued By: Rhonda Thompson Current Permit Fees Paid: $525.00 (additional fees may be required upon installation of system). Permit Expiration Date: 10/03/2026 (based on date of Inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backlill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. i • OFFICIAL USE ONLY - GATE RECFN[O C . I IA, MASON COUNTY y > cn trig COMMUNITY SERVICES .MOIJ 21T - a FcEXTE 03 CO o m Public Health(Community aA Ern nmental Nealt'I ` < N ...nn,_,-,N�w.MM. SWG 1eIn _oc N1 o 8z • z N ON-SITE SEWAGE SYSTEM APPLICATION E• > E • n APPLICANT PHCNE m r Empire Home Construction David Duvall (360)751-8062 z p O.OBox-STREET.CITY.STATE.ZIP CODE Kelso . WA 98626 3 m ADDRESSSITE 560 E Lakeshore Dr E Shelton WA 98584 F I N' NAME OF DESIGNER PHONE CD IN Arrow Septic Designs (360)898-2255 NAME OF INSTALLER PHONE o Mason County Excavating (360)490-3144 m I PERMITp TYPE(se)em onel C C DRINKINGIN WATER SOURCE Q h.RESIDENTIALOSS IL COMMUNITY ass Y.ICOMMERCLALass /a PRIVATE INDIVIDUAL WELL t7 PRIVATE TYC-PARTY WELL Z I --4 PE OF vORK(select onel Q PUBLIC WATER SYSTEM TYg NEW CONSTRUCTION/UPGRADES f REPAIR/REPLACEMENT OTHER SETAS Noonan tar apd) D TABLE IX REPAIR N) ICT SUBMITTALSM 1 0 SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE CO LYL DESIGN FORM(REQUIRED) ASEPTIC DESIGN(REQUIRED) i BEDROOMS BR LOT SIZE Q I CD OF APPLICABLE) _ _ __ 3 .20 acres o I DIRECTIONS 10 SITE AND SITE CONDITION (ex roc/mate) O S Go out Hwy 3 and turn (R) onto E Pickering Rd. Continue on E Agate Rd. Turn (R) onto E I 0 Timberlake Dr. Turn (R) onto E Lakeshore Dr W. Turn (R) onto E Timber Pkwy. Turn (L) r I o onto E Lakeshore Dr E. Yellow sign: "Empire Homes#560" aIA oiI• RAG GED FROM MAIN ROAD AND TEST HOLES MUST BE FIAGCEO MTH TEST HOLE NUMBERS cn OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE ffor reiaor.rng pu'ooses) ❑VOLUNTARY Q MAINTENANCEPUMPING 0 BUILDING PERMIT 0 HOME SALE • • 'INT 0 OTHER. INSPECTOR SOIL LOGS 0 J Z S L- ( ,� SE ���• Omorvs 'V' 0- L' Sul 11 4- -1'I I( � - RECEIVEQI 1 bwkNei 4Lezn—s� i , oa , j RECORD DRAW ND AND INSTALLATION REPORT SON.CODES: ▪=VERY G=GRAVELLY S=SAND L.LOAM S:=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINALAPPRCVA INSPECTOR SIGNATURE � ���AI> ���r+Ancv DATE -- - IR APPLICATION APPROVED;ssuEo3r DATE APPLICATION EXPIRATION 0(4�1}1(1'� 7, /7� ( Z THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE PEVISE2IID2015 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 0 1 7 — 5 0 — 0 0 0 4 5 A design will be reviewed when 3 copies of each of the following are submitted: 'r Completed design form that has been signed and dated. Scaled layout sketch,including all applicable items on checklist r Scaled plot plan,including all applicable items on checklist. "Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X 17" Permit Number: SWG Z0213 00.S� r�+esigner's Name: Arrow Septic Designs,Inc Applicant's Name: Empire Home Construction Designer's Phone Number (360)898-2255 Mailing Address: P.0. Box 241 Designer's Address: 171 E Vuecrest Dr Kelso WA 98626 Union, WA 98592 City Stale Zip City State Zip r ,1 Th. AIESLELS PARAMETERS . Treatment Device ❑Glendon Biofilter ❑Sand Filter 0 Mound ❑Sand Lined Drainfield 0 Recirculating Filter,Type: Et Aerobic Unit MakeMfodel NuWater BNR-500 0 Disinfection Unit Make/Model Other 500 gallon pre-trash tank Drainfield Type ❑Gravity RI Pressure fi 'Trench 0 Bed 0 Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 Schedule/Class 40 Daily Flow:Operating Capacity 270 gpd Length (2)55, (1)50, (1)40 ft Daily Flow:Design Flow 360 gpd Diameter 125 in Septic Tank Capacity(working) NuWater BNR-500 gal Number 4 Receiving Soil Type(1-6) 4 Separation 5 ft Receiving Soil Appl.Rate 0.6 gpd/ftc Orifices Required Primary Area 600 ft' Total Number of Orifices 40 Designed Primary Area 600 ft' Diameter 3/16 in Designed Reserve Area 600 ft2 Spacing 60 in TrenchBed Width 3 fr Manifold TrenchBed Length 200 ft Schedule/Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 2 % Diameter 1.25 in New Slope.If Altered 2 % _ Preferred manifold configuration used? Rf Yes 0 No Depth of Excavation Up-slope at i•,/- ) Transport Pipe m from Original Grade nowsmpe 42 S in W��' Schedule/Class 40 Designed Vertical Separation 13 in Length 30 ft Gravelless Chambers Required? ❑Yes 0 No IIr'Optional Diameter 2 in Pump Required? ft Yes 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 4 Dill in Elevation Between Pump&Uppermost Orifice 5 ft Dose quantity 90 gal Drainfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 1,000 gal Uppermost Orifice rif Higher 0 Lower than Pump Shutoff Pump controls:Please check those required. Capacity a Total Pressure Head 23.6 gpm glrimer lElapse Meter Ir 'Event Counter Calculated Total Pressure Head 8.63 ft If Timer: Pump on 2 minutes pump off 6 hours Comments T Pf< 0 I..r/ _. DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 0 1 7 — 5 0 -- 0 0 0 4 5 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch fe Test hole locations g Drainfield orientation and layout Reference depth from original grade: g Soil logs g Trench/bed dimensions and g Septic tank 0 Property lines critical distances within layout 61 Drainfield cover ❑ Existing and proposed wells D-BoxNalve box locations Reference depth from original grade within 100 II of property g Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts,banks,and locations g Laterals,trenchbed,top and surface water and critical areas lig Observation port location bottom ❑ Location and orientation of lig Clean-out location 0 Curtain drain collector curtain drain and all absorption g Manifold placement 0 Sand augmentation components 0 Orifice placement Other cross-section detail: g Location and dimension of Lateral placement with distance Observation ports/clean-outs primary system and reserve area to edge of bed Buildings dx Other Information Audible,'visydl a referenced Yes No • Direction of slope indicator g Scale of d n on scale g 0 Design staked out ei Waterlines bar 'sP. ,'.�f ❑ gRecorded Notices attached g Roads,easements,driveways. ''-y. '. !' ' fiirx fir 0 Waiver(s)attached parking . ' j' •..Apv, g 0 Pump curve attached :^.} 0 Eg Evaluation of failure g North arrow and scale drawing :a .. sco e shown on scale bar --=. PAULF dot uonason'. Non-residential justification y7 f?�� $ t) tONW. ❑ fig Waste strength rwnea 9t r 0 g Flow DESIGN APPROVAL The undersigned designer must be no ' d by installer t timeation g Yes 0 No A 2), -L`(-23 Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: uRn�ti n�f v t tilAr) Lof t-t 123 Environmental Health Skecialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: I The design is stamped"Approved"by Mason County Public Health. �.., ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: (.0 '3/ C4 ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12 7/2015 0 y NJ v Pam' a "t T N . aka s t 0, 1t F a % AA Zz bjx \ F Z z ANr i .Jt �t W N m ' ao 4 1 $ I n \ 0 s/e R / 1 ice z MC3 I 11 . > O 03 � �� 4-N. S � i � .a3 a h }T W. / / "�✓�" :: ‘ :1 li PI. 0 x Ii N, A f- •t� }' !i �/� h N : U i v (n a ,� I �_ F e ! �(—`��� C & d t wvv't 4 :.—D1a 4`2. d� 3 �. p, e i? A " ,- .- F --+ =— \�t ;t yt j y� t 'z�� `.34 d n I"]T y r re OCT 04 2023 MASON 6JUNTY EN41RCNYENTAi.HEALTh' NET 2 .E TO .4: - APPROVED 4 OCT 0 4 2023 �f 6 � � a. ... p� ..y `'rr13CNMETAL HEALTH� ,` � tA'J,„ • REi t f,o,.s 4� Q� PAOLA JOY JOHNSON 22 to Lk; S f Ell" RES 14' e Y s p-� og0� 0 Q 0 . rO t* FY'iMaryi- G i - - 2 ' x418 %,e1seW2 areas -Fro w\ . • © J'P.1.niCle. a Fc1 L. e — I Y5 4-2 , ei_AeLatn \bCO 4-%1 te �S � ` ef5 (2.) 3X85' cc , .i .--- (1) 31 x SO G Qrievo.-y D.F. ,„;, Trevtrifies c-+ S D-C• vYJ " 45 / LAD'iill Res ereenbove _ F. !_o-ke&Clove. -Dr. o d below Key_: - F " = 7-06 CM �:i o-visld:- b ,v 'S za o 9C � . VP.L'A ''Pis_ !1 Cl!eanout _y., U Evn fl , re- ieuTe CbKS \ SCO Gallo f e-T ash an — ret needed i wv.cre -4ank5 NSGl CI:)C E Lo.Y-es tct . Dr. E J N-Water BNR-500 ATu Tank (5VTe. I, \e.., .L'Pf `l8 btet 1,CCC Galion Pump Chamber I `/ w.Y�. u...w�- rty Leer. eFaAtce..j V22e I-7-So-nc045 Valve Control Box AV No ,p-( A I--t it olo-L—tt- Ar\-_} taita C oua,eel rakes •� �,s aL t T C•2Y + +� W 0� 1ls.� 6Cssh A•sCi��1 .2'S c,o 6.51 'C 6e • 0 4 ' 55' \0 _ . ,bD I - SO' - - CJc¢a^v'.v' ci_ i o<G. M.M. 40 ' . r p 2„ Tieital Or;-E'en Crich 2%569a / line TAENn' , IALl4EPER THAN: 1.25'.�maBx. UF,.. ..HE $caQQ : 1 �t=for -- ;.aa DUJVNSLOPE '�" 1 1 t o s to (S 2.0 APPROVED Toad Obeers n Part • OCT 04 2023 . MASONCCUNFE5ti1RCNYENTALHRLTH 9 a +z • RET Fa Fmri �' • Detailed Drainfield Layout y! a . Za Sere + • t0 � • v a+2' Cr- tzT Lase 1 t I t......1...1 V - by • ,}' 3fi of -� SoerO" Qi . 0" as Ogee Feaa — a.aiaa Droinfield Cross-Section View � • ; a. a. • w To Scots Nr Calmat ar from ersOno ea.. . ) Fiidr! SraFe. Mat se la Sm. G•w aV NNa 0 • mar win Pat wr !.f� p•aia! d,as End d Fad +.a+YLL Tab 4' FK Par Oa Woo d TnvW d , h To Fbssd be. srula fi •td be ... °"�. . �'1, bead a (aF.aObwtPi •' ' r Arrow Septic Designs Se Sae AP °"°" T` y Y'` (360) 898-2255 Ifs d k Told p�ja/ jt SJEIY �_'� p0.VLA JOY JOHN60N�'. LiCkYlSE 1 5i vow. FJWRES t PPGE*OFCPAC S . Length Length Orifice # Distance from Distance from Lateral# (In.) (Ft.) Spacing Orifices Feeder Line(In.) Cleanout(In.) 1 660 55 60 11 30 30 2 660 55 60 11 30 30 3 600 50 60 10 30 30 4 480 40 60 8 30 30 Total Lateral Length 200 Total#Orifices 40 GPM = 23.6 APPROVED Dynamic Head Calculations OCT 0 4 2023 Selected residual pressure: MASON COUNT'ENv1RON4ENT'L HEALTh 2 ft. RET #Orifices Length (Ft.) Transport Pipe 30 40 0.30 ft. • Feeder Total Lateral Line - Length Lateral#1 55 2 57 11 0.37 ft. Lateral#2 55 7 62 11 0.41 ft. Lateral#3 50 12 62 10 0.34 ft. Lateral#4 40 17 57 . 8 0.21 ft. Total Elevation Lift 5.00 ft. Total Dynamic Head 8.63 ft. SECURED LID WITH GASTIGHT SEAL THREADED UMIbet SP DIAMETER ACCESS RISER r SERVICE VALVE' . . /t it r.=.TC OruWFe.D c I .. A 1'J I • 1 I 'I SIPHON sroRA6E ' ARVTr HIGH WATER ALARM LEVEL 1'V YIOIOIIrIO VOLUME ' .1H09Tt HOWEALTrr!!ApPF LEVEL t • 4mm FOR O FLOA J� ,�, Iall pI�II VALVE' �jy sf 1 S^ s -'� - D . . 4='mi.ir BUSIMESISSOLE CENTRAL a ' '�� aE PUMP :1. 1049 ryas/ '5}PAULASJOYJJOHNSON LICFMSFD Il) G 'ASS ?, R lured by WAC chapter 246-272C and standards required FIGURE 2 Septic Tanks must meet manufacturer must be on kept of Health list of registered sewage tanks. 5 • 10 7 '� page 35 of 65 137 A?1 Bronze construction available(139 series) (• High head version available(145 series) > • Double shah seal versions available for added protection Flow-Mate on models 140/145. For more information,see Technical Data Sheets FM2782,FM2 Z83. In high head dewatering or effluent applications where pumping -' performance is critical, this robust _ -_ - Noo4�A1ANCE`"a" ,1401,45 family of pumps is known for reliability, - Ell and performance. These •-. pumps are especially suited for harsh •r environments. Zoeller's coot run designilli (p and corrosion-resistant fsh t powder coatedng, y c epoxy finish add up to along-lasting, 9' trouble-free product. ' �-, ■n G_ APPLICATIONS: . ®, . 71 • STEP or onsite applications " , ■ M • m • Water transfer : Z • Light commercial dewatering 1Is� ' SPECIFICATIONS: �� �./ • 1-1/2"NPT discharge ��z !N '-- i� ,� _Immi n � • 1R HP throughl HPIt' MADE IN THE USA fl I • Available in automatic or nonautomatic LEHREPIr191EE MIDI • i h vortex o te0i 1pel 112 mm)spherical solds^ P F . capacitywith 9,14x:1 impeller o ds '" • Model 145:3/4"(19 mm)spherical solids capacity with 3.s.a i_ 4 4 " vortex impeller OCT 0li 2023 '"'"'•"° 52p5E .::- 4 MAS0't000NT' EN IR SYEN 1LHE<I- 1J�1 r, RET PUMP PERENCE CURVE MODE 151 52/153 Dose-Mate or eQu Nut1 a Wea This is our fastest growing line of effluent 14— 4s 153 pumps.The 150 series is truly a workhorse I designed for reliability under extreme 4I conditions in an effluent environment. as 150 series pump curves cover a wide range a z0 of applications. They are well suited to Li I s a0 applications with low pressure pipe(LPP) , a- 51 and enhanced flow STEPsystems.Zoelter's Zi cool run design and corrosion-resistant, B powder coated epoxy finish, in addition I to the hermetically sealed, oil-filled motor a,'I .e and non-clogging vortex impeller add up to a long-lasting,trouble-free product. 10 ® T APPLICATIONS: �' • STEP or onsite applications 0I 60 rl e MADE IN THE USA to 20 30 40 50 0 80 .. 100 • Light commercial dewatering (SINA ItUlDl IF 35.[01191 GALLONS __ __ _ 3 40 30 120 1W NC 240 280 320 360 SPECIFICATIONS:di 6a. FLOW PER WW1 014538 • 1-1/2"NPT discharge • 3/10 HP through 1/2 HP a • Available in nonautomatic or with a variable level piggyback mechanical switch 1/2"(12 tom)spherical solids capacity with vortex thermoplastic impeller For more information,see Technical Data Sheet FM2784. ©All rights reserved. ZOELLER PUMP CO. 1502-778-2731 1800-928-7867 I zoellerpumps.com 9 n✓J 9$69 9 899L-L89 O9C 3NOM E sso aervvv3ria Cr Sei10o SN:aS 69990t-LVM9ON11OW 3L1V6 L60f X09 O d Liito i. E9° ° •3N1 JNI�I32NIONB h3 Bey 7 APPROVED OCT 04 2023 a s <D, I� YASONc3UNr'E'wTROHYENTALHEALTH -� 1- RET " -p' t = r' s � L . L-- III zf. __ 0 )111 I� t1 \ I �a - y - i e0i1i.,;: .: b L o -. \ / s . 1;1, :,!![;; _ - -z5 .- Ia n I —44,„kp 9'2 • WATERT]GM � LID VENT(t p) DUAL PORTAc'RATOR� • RISERS(TYP) ��^� ��— _T yZ SS Ld 1 35 MAX1 1•PVL(:: ($ 1 f •J •_ VT PVC1 AIRLINE MASTIC C 3 L / r AIRLINE I YLOUPLING I , S.RPM ILER 'II I III +1 - 1 2 TEE `1•PVC SLUDGE 12 RETURN LINE F-Q I 2.PVC /' �./ I TRASH CHAMBER A DIGESTER CHAMBER I CLARIFIER OPFFRATING CAPACRT:417 GALLONS IS- OPERATING DATING CAPACITY, GALLONS CAPACm.e90 GALLONSLoop WAcnr:a9a GALLONS 160 GALLONS / --\\ I IFL000:191 GAL.. . III I S. I 50• APPROVED ,1TE'" • OCT 04 2023 �• Ml04 COU'ITY EY,IRONYENTAL HEALTH • 2) Y DIFFUSER BARS RET PAR LiOTANKW L / ,. ` 3• SLUDGE RETURN 1 SNE VIA' // // IS TAPER -)/-i A STONE-FREE NATIVE SOIL OR COMPACTED SAND INSTALLATION INSTRUCTIONS OVER STOAT SOIL 1)Excavate tank hole Mt vertical walls to 1 foot larger than tank on all sides. 2)If bottom of hole is stay,install 3"of compact sand&level $ aY A out with screed. N r 3)Install tank in center of hole,keeping 1 ft.void space on I 7 P all sides. I r 20•RISERS P) N'BLOWER I 4)As tank is filling li water.fill in space y. compact �i IHouH s1rlG Gsi, granular(sandy)soil free of large dumps of day. / \ \N*o_P OF(L/'q 5)Install rest of system.S affix risers to adapters with waterproof adhesive. l �\ 6)Perform water:iollmess test in field as required by local • (unsdictia. � I 7)Upon approval to backfill,carefully backfill with native I 1Y RISER soils over top of tank, i TRASH CHAMBER I (AV LEES I P RR468I 8)Fnai grade the surface to avoid chanelling surface , L_- water toward tank. -——- TOP NEW ,r ..o.it , AEROBIC TREATMENT TANK DETAIL FOR 4 :� NuWATER BNR-500 TREATMENT UNIT t�. I \1�� ENVIRO-FLO, INC. FENDED: Wastewater Treatment Technologies 3/01/12 -:s, `r' PO.BOX 321161,Flowood,MS 39232 (877)836-8076 (601)8454716 fax scAtE w.erwro-fo.net 1" = 1.4 ft. ww 6eg0 �` ` sN - Water JI > t-a._. M i • APPROVED aCkD 4 2023 e- iz . AMASONFLUNTYEY ,sift TALHEALTH !,. 4ET - , N. v\�® `* ' Ls $1. _ I n 1 0 ` ♦.� CVO j Q``� rilz<5 et yLvtie r,R A 7, _ 7• Ni %II ilk gratO I) iir4• 1:+� ' [/1 Ui U/ i PARTS LIST NuWater NR Assembly Diagram V i P DUAL PORT AERATOR M.POLY OIF FUSER EAR(2) 4, R; B.air RUBBER 00°VW CLAMPS 12) N t"PVC(2 1ft SECTION) ll C.3/8-BARBED ADAPTOR X ifY NPT fC 0 I"SLIP D.t0"SLIP X1/Y NPT ADAPTOR P V "CLEAR PVC HOSE(OPTONPLS [C-t© a r STREET X 1!I NPT BUSHING(3) 0 1/2 PVC PIPE(8Y INSTALLER) F ifs 90'ELBOW(3) R.V PVC PIPE(BY NSRdLER) H. X t'X TEE T. PVC PIES(AY INSTALLER:.lO H.V X ELBOBOW(8) T.ler A BARBED ADAPTORTO /6"NPT(2) 12-X V BUSHING U. 1?STREET X t/a NPT SU51i1NG:2) 1 Y SANITARY TEE V I a'PVC COUPLER(2) K.P PVC CROSS W T COUPLER;BY INSTALLER; L.V COUPLER(BY INSTALLER) Revised 2/25/12 q8Eio asiteut Septic Deoicgito NuWater BNR Pretreatment INSTALLATION&MAINTENANCE _,«s., :y?t Pressure Distribution Systems i ; t PAULA JOY JOHNSON Eel L'iCt=NSgtlUt5i6NEH" 1. Install Laterals with contour of the ground. 2. Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock, (do not glue), after pressure test and Environmental Health Dept. approval, turn orifices down(6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of tuning the orifices down to the 6 o'clock position. 10. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 11. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area. 15. Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19. All pressure systems with a pump chamber outlet higher than the drainfield must have a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines. 22. Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation& Maintenance on your APPROVED NuWater pretreatment system. OCT 04 2023 MASON CvU4'ry c1i9Rp5454I41.HEArP PET 10D