BLD2012-00385 Final Reinstated SFR, Porches DDR2012-00086 - BLD Inspections - 11/22/2023
4 " Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 - ava� Shelton, WA 98584A Cd RESIDENTIAL B ILDING PERMIT BLD2012-00385 OWNER: ROBERT SARGENT ,1 RECEIVED: 6/4/2012 CONTRACTOR: LICENSE: EXP: L ISSUED: 7/9/2012 SITE ADDRESS: 2010 ONE TAHUYA BLACKSMITH RD TAHUYA 7, L. EXPIRES: 1/9/2013 PARCEL NUMBER: 223195000112 LEGAL DESCRIPTION: WOOTEN LAKE LOT 112 & 113 VOLUME 4 PAGE 4A PROJECT DESCRIPTION: DIRECTIONS TO SITE: REPLACE MANUFACTURED HOME WITH NEW RESIDENCE, with ST RT 3 TO BELFAIR, L ON ST RT 300/NORTH SHORE RD. R ON BELFAIR screened porch +4 other covered porches TAHUYA RD, R ON TAHUYA BLACKSMITH RD TO SITE ADDRESS ON THE RIGHT General Information Construction&Occupancy Information Square Footage Information o.of Bedrooms: 2 Type of Constr,: VB Type of Use: SF Insp.Area: No.of Bathrooms: 3 Occ. Group: R3 Lot Size: Deck: 430 Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,577 Valuation: $ 336,187.17 Building Height: Occ. Status: Primary Basement:1,538 cov porch 464 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. FrontNW 25.0 Ft. Shoreline: 64.0 Ft. ater o y: HAVEN LAKE Rear: SE 64.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: 20.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: 20.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt 0 Water Closets (Toilets) 3 Furnace<100K 1 Planning Review Fee GMM 6/4/2012 $205.00 S12012000000dj c Lavatories 5 Heat Pump 1 Plan Check Fee GMM 6/4/2012 $ 1,257.46 S1 2 0 1 2 00 000 001 Bath Tubs 1 Ventilation Fan 6 EH Plan Review KKK 6/4/2012 $ 103.00 S6201200000001 U Showers 2 Propane Tank 1 Building State Fee DLC 6/22/2012 $4.50 S1 2 0 1 2 000 00 0010 O Water Heaters 1 Gas Outlets 6 Building Permit Fee DLC 6/22/2012 $2,320.95 s1201200000001� Clothes Washer 1 Fireplace 2 Mechanical Permit Fee DLC 6/22/2012 $339.10 S1201200000001t Kitchen Sink 1 Exhaust Hood 1 Mechanical Base Fee DLC 6/22/2012 $28.50 S120120000000t " E Plumbing Permit Fee DLC 6/22/2012 $ 145.40 S1201200000001 Dishwasher 1 Dryer 0 D er Vent 1 Plumbing Base Fee DLC 6/22/2012 $24.70 S1201200000001� Z7 Hosebibs 4 - a, Laundry Tray 1 ADJUST--Plan Check Fee DLC 6/22/2012 $251.16 S120120000000( Total $4,679.77 C BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 1 of 7 � C. CASE NOTES FOR BLD2012-00385 CONDITIONS FOR BLD2012-00385 1) A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450. The building permit will not be"finaled"until the permit holder can show proof that the access permit from Public Works has been"fin d1' pproved. Xf O 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-64 -098 The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) Owner/A ent is res sible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X i 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Departme t rior to any further inspections being performed or approvals granted. X -a-.+ 5) Owner/Age r t i sponsibte t post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. 00 6) The plan review c�tandections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the C corrections indicated on the plans. Once the plans are marked"APPROVED", they shall not be changed or altered without authorization from the BuildingC Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or 0 C removal `f a gtoved- currents will result in failure of required building inspections. CU o N X m o 7) The"appr "srte plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the E Buildin Departmen or to any further inspections being performed or approvals granted. 0 X L a- L.r LnL�, W BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 2 of 7 CL 5) Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table 9-1 shall be completed: Option 1A, Heat pump HSPF 8.5 or better X 9) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls, foundation (slab, basement wall,crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration;and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area(SLA) when tested with a blower door at a press of 50 Pascals(0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical,ventilation, and combustion appliances and sealing thereof.The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate"and are available in %or sheets. The Mason County Permit Center will also have some available. cw�4 10) A minimum f-50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSE Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor ors installed in(or r around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Reference, SC 5 X i 0 D c 11) WIND LO a:w..Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85C U MPH. X 12) REQUIREMENTS-FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the ° manufacturer's installation instructions. X © .s d a—+ I_v BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 3 of 7 YS" 3) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. `NOTE if Stormwater Management option"A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contracto Isaeknowle ging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 14) The international code requires a fire apparatus access ro d-for very facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads 8nn�ct with unty maintained public road or to another fire apparatus access road which connects to a county maintained public road. X L . 15) Any changes i proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and 01all bee collected by the Building Department prior to any further inspections being performed or approvals granted. X 16) All construction rftust"meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washingt Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocatl.. 00 w ® n c c C o ® U c � a E G L E 0 C t� nL LL ion C: BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 4 of 7 0 " 7) Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and IMC. Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches(38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA)and be so labeled. (WSEC503.4)or in accordan e 1411. X 1 ' ' 0 18) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition(or major renovation)of any structure unless all asbestos containing materials have been s identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or 0 p operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org U w 19) Provisions#Q[..suelsubsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact 10 o rfac adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the co stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further E information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which a is proposed to be located wi in 5'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may Q c affect your project. X LL IL BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 5 of 7 't;. 20) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regu�ti(M,-_M t-be�reviewed and approved by Mason County prior to construction. X r' F 21) CONSTRUCTIO `PRO0CESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shal!)be madepdor to requesting additional inspections. X_ 22) All propane tanks LibejnstaIISd_,mqccordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installatiopUoqdkments and inimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X , 23) All property lines shall e-el2arly identified at the time of foundation inspection.X 24) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration.The failure to request a final inspectjort-or•to-o n approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County g i --n " nd yildiri -regulations. X �J 25) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time forty action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevent ion from- Bing taken. No more than one extension may be granted. X 26) Retaining walls ne o support a surch ge-sd as structures, roads, or to support slopes, shall require a separate building permit and approval prior 4" to construction of the retaining wait. X '~ 27) ALL SURFACE WATER AND POTENT IAL:F.ttrJl�i' FF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT 0 PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTENO c OR ROAD WAY. o X o v (n 10 28) Approved per dimensions and setbacks on site plan submitted on June 8, 2012. Distance to shoreline to closest proposed roofline or deck shall be 64 t6 X et or gre e�S �ba�k8-to property lines and shoreline are measured from the furthest projection of the structure. j o E 29) The proposed project must be consistent w' h all applie le policies and other provisions of the Shoreline Management Act, its rules, and the Mason 0 County Shoreline Master Program. X i 30) All construction and demolition debris must Semm`oved from the property after project completion. Proper di sal of construction debris must be on "0 land in such a manner that debris cannot enter or cause water quality degradation of State waters. X - (U BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 6 of 7 '� 31) Prior to final approval, all upland areas disturbed or new cleated by,construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 32) Temporary erosion control measures must be implemeflted-to-06vent water quality radaYj,Qt1 of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced vidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuatio f work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Ma n County aE es o he ove described property and structure for r iew a inspection. OWNER OR AGENT � —�ti� 'e �� — DATE: U) t` 00 �s C o ® U c co G E 0 U © c L 0 W C BLD2012-00385 Please refer to the following pages for conditions of this permit. Page 7 of 7 CONCRETE MECHANICAL MANUFACTURED HOME D Date By _ _ X FO Footings!Setbacks / /' �ti Gas Piping Ribbons G) Interior Date�5'� y -� By J/' Interior-Date 11���1'1 BY A L Dale By Z 00 Exterior Date :qJ� lay Exterior-Date ay Set- "4 u Point Load/Isolated Footings ', INSULATION Date B X Date �T•v�i' - BG f SLAB INSULATION Y 00 -� Bye` Data ay FIRE DEPARTMENT m Foundation Wails 1r�7� / fA '' L� Floors 4 p jrJ3car',4ti Date By X Date By Data Sy DECKS FRAMING Walls Date By Date j / gy Data 111,7111HBY L PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundworij%(yy,&9 Attic Date -3`f By Date By Type- Date By o-w.v DRYWALL Type. Date jillijoe By + 1, Int.Brace Wall Date By 00 N LiiRJ Date BY FINAL INSPECTION p Water Line Fire Separation N Date By Date By Dole By m N g Pass or Request Inspect. b Type of Insp. Fail Date Date Done By Comments w 0 Z3-!3 •1TEAq ` Z �3 - -aq 0.4-P) L z/� 0 7 1 N l ! I I l cJ G S L v l <' N 1 L l r `" eev h{� w� �- .ems i i D ✓T�f�.c�'S�'j2 "�-�r f� J J-V .C3-�i�'/Il� v� LOG _ e. QJ C �-)ranted From ��' � `�o s, T-c r i .7 ills l /VLF �i� UvI f�.�d� i 41, �� T I'rinted�t� OLD:=punty�M �11 il-k 7v�, 7'tJ r �J �✓J ; j� ��'•�-✓J/> ItlliS'il/t'�. fib-Uk-7_1. M& �:�r.1 - S r.:�. ��--- l �'21-33 VGD 'F 1 AIA-1-- vPk�6 o CONCRETE MECHANICAL MANUIPACTUREO HOME y Footings!Setback& Date By Ribbons Gas Piping o IntertorDate By Interior-Date By Data By oF.xteriariDate By Werior-Date By Set-up Point Load/Isolated Footings INSULATION $ By BG/SLAB INSULATION Date BY Data By FIRE DEPARTMENT Foundaalcn Walls Floor& Dale By Dane By Data By DECKS FRAMING Walls Date By Dane By Data By PROPANE TANKS PLUMBING Vault Data By Data By OTHER Groundwork Attic Date g Data By Type: y Data By D.w.V DRYWALL Type: Date B Int Brace Wall Date By -0 y Date By - FINAL rrvsP€cnoN Iv Water Line Fire Separation Daw Dy Daie By Dale By m Pass or Request Inspect.. Type of InsP. Pail Date Date Done By Comments o ASS �55 3 ►y ` ►r7 _�Ia'c 1/L� G 104� T.� /G ���Ll .� ��I�-�` ors. y►�,C,t,,�. . r^,vwb I' c ti ����•�w I ip uvt, N4L Stows 3. tj fo 4 CD �..t k �:u�� r�s=s �- � J- 3 sty►�s i r�s'Ck�Inp �a �c�f r►,ce,-�' Rsc. uc, �.'t u.� . 644r Slgy 4 iY, o _ Alt' - wTio, sgoup> Printed From Mason County UVI Printed from Mason County DMS Birllding Permit #, MASON COUNTY BUILDING 111 426 W. CEDAR , SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location & 1 This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance _ fry G��'✓!/fir///�' � �oT/ �1� �=u�J /fin) v '!:�'vT- F'��/ ' ' v _ vl/ c G �- /�/S L� L T a2,k �✓ L - - ✓ S/ You are hereby notified th;df the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department oL40 Date f — Z 8 ;l 3 Inspector :7�a h - yjMGV� THIC TAL PrinNer!nruntY i-a Building Permit #13,,'o 12-Cx-)2&`T— MASON COUNTY BUILDING 111 426 W. CEDAR / SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location W10 V �� This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 9) c o SL .r o,✓ c�it� o '� na2!?� 4jai v_ /� �-CS !� d/r yG ov Jl.�,w�3�—�� d 7` 3 z �o �v rlo,.� Lot dy SST a B y /Z . You are hereby notified that the above corrections shall be made,_,, BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection This is not a complete itfspection Department Date 1 —1 3 Inspector -1" T/� ,R L ;MOV TH11" TA" ,r I nn i n� ,....so aurl.y JIB 8uild;ng Permit # _"���`� MASON COUNTY �� �"� 'n y BUILDING 111 426 W. CEDAR ����-',✓� �I' ������/'�� SHELTON, WASHINGTON 98584 � (360�427-967000RR T3✓'i— +✓/�?F iir::�� �i.:s�t:;,ir, Tit�/i EcfliON ���/¢��ca ' ��.�_�y''�� .,���«+=�✓-/7 Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance b4z) • f c R'L�e z&l Hae fE Td y ' o LL ' `S ' of �zn -1/ iv �1/ "�G- �✓ C /fit, G,vy � F,vtL_ f-E (-42 C C aVA14 ou are hereby noti ied fhafthe a ove correctiorfs shall be made EFORE PROCEEDING WITH ANY FURTHER WORK 4LC, 1�rt'4'v'0 l A�niens�amid)r✓✓ t 5 1 A i r forf/F Call or re-i spe o correction ree before conti mg rI THq%ALL- F/)(7-V17C ❑ Make corrections, items will be checked on next inspection ��r4p,OF-o-11" ,lep 7- OK to p0/Yc�" f�R This is not a complete inspection d� �Im Department Date Inspector no ; "f)n �lVIV THIQTA ,r tI 11 svj& 'Coutl[Y b Permit# 2 3S' MASON COUNTY BUILDING Ill 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location ZOl U This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance 3 H y L -ro L c-r rG v lL T O � 1 I n� z t l KGa wtt G,.� to G tis L.SrCr e, ✓D✓L C, ti X LAL( Y itj�yY{v, r h1 1L51 1• TO �.G(�� z _to k F GU�tiG 47 eloax- e,-T .n 1l I -44A A-T-T"C- T M� nTst, N �.�� �z� v le- 441 k2 L�'Ct_ 1 —trti s c S - ^s. 1 r• n U...` u ,.S"ta l l i a►l f T To a , 'ram c You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is NOT a CORRECTION NOTICE. Date 1 df q11 q Department > Inspector (i� PriDOoNGT REMOVE THIS TAG Printed from Masan County OMS MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 t '1 Building,Planning,Fire Marshal 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 1 C—\ ZQ —Oj ADDRESS/LOCATION:Zc� \b /� �o�hy,� rl C c v,:Z-sMk FINDINGS: Sr�U v E rvt . \oc- Ln, I�Y�C eV17CL-n.- fe C ���. p`(�In aS Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: \D-- �.��~� ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: _ ( f t _ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 5007 Pacific Highway East,#16 Fife, Washington 98424 GCOResources, (253)896-1011 (253)896-2633 Daily Field Report OWNER JOB NUMBER Woodland Industries Woodland Ind.LakeHeaven PROJECT DATE Lake Heaven Residence February 4, 2011 LOCATION WEATHER REPORT NUMBER 2010 JE Tahuya Blacksmith Road Prtly Cloudy 1 PREPARED BY CONTRACTOR: SITE CONTACT: PAGE Keith Schembs Woodland Industries Lee Rogers_ 1 of 5 PURPOSE Or VISIT SUBCONTRACTOR SITE PHONE PERMIT NUMBER Foundation Subgrade (253)606-9663 We arrived on site at the request of the contractor to observed the condition of the exposed subgrade soils for the proposed single family residence. Upon our arrival, we noted that the foundation for the residence had been completely excavated and that the back, basement wall had already been poured. The front foundation and deck foundation still had to be formed and poured. The front foundation line was about 6 feet back from the break in slope, while the deck foundation was at or just beyond the break in slope. Based on observations during our site visit, we noted that most of the foundation excavation consisted of hard, unweathered glacial till. We probed the front foundation line with a '/Z-inch steel T probe and noted minimal embedment (less than '/z inch). In our opinion, the front wall subgrade soils appear firm and unyielding, and suitable to support the anticipate loads. The deck foundations, located at or beyond the break in slope, appear to be founded on glacial till fill. When probing the fill, we noted up to 4-inches embedment. We recommend that the deck foundations be deepened a minimum of 4-feet. This depth will ensure that the foundation extends into the deeper native soils and has a sufficient setback from the top of the slope.We attached a detail showing the deepening of the foundation. For the piers, we recommend 12-inch diameter drilled piers. These piers should have or exceed the typically residential bearing capacity of 1,500, but structural steel spacing and configuration should be confirmed by the structural engineer. X CA Photographs of the rockery are attached to this daily field report. aF w ,�. ,;� .� -,_--,-emu., - _¢..�5, ��- --r -•¢w ,:� ,�,���', i eoReso leld Technician GeoResources Project Manager Printed From Mason County DMS Printed from Mason County DMS Conventional Footing , i Residential Structure Slopes Greater Foundation Than 30 Percent Element Setback Distance Footing Extension Residential Structure Footing Extension Slopes Greater Than 30 Percent Foundation Element Setback Distance Not to scale GeoResources, LLC Structural Setback 5007 Pacific Highway East, Suite 16 Proposed Lake Heaven Residence Fife,Washington 98424 2010 NE Tahuya Blacksmith Road Phone: 253-896-1011 Mason County, Washington Fax: 253-896-2633 DocID:Wood landlnd.LakeHeaven February2013 Figure 1 Printed From Meson County DWI Printed from Mason County DMS r m "'sss#'#►#►""" d5"l�Jc Lt .t."k ..*A r ✓ t�i7.� +La /°c eE`'.f`'i !• .. :.tea« 'f: yi .v .�. ;1 I,',:�• f ' 6 } 1 p --wow a - w •u a w '+ f _t l � C � co IS 00 C � O U c ,Y q3r i -Hayes, PE Nabil Kausal&KH1 8739 21st Ave NW x Seattle,WA 98117 ENGINEEwww.nkhengineering.com MEMORANDUM : TO: Kevin Holmes- Holmes Construction 136 ` FROM: Nabil Kausal-Hayes, PEQ � i'' DATE: November 15th, 2023 ` t AL PROJECT: 23-127 Haven Lake Assessment 11/15/23 SUBJECT: Assessment of existing deck&sunroom conditions This memorandum is in regards to an existing deck that was constructed with a residence near Haven Lake, WA. It is my understanding that the county is requiring FOR approval/verification of the existing deck. On November 2nd, 2023 my associate Allen Rishel visited the residence to observe the deck in question. The deck is constructed with 2x8x1O'-O"joists @ 16" o.c., (3)2x8 beams on 6x6x8' posts @ —6'-6" o.c. w/ 12" diameter sonotube footings. See below for our recommendations. 1. Attach the 2x8 ledgers with((2)%0x4"L Exterior Grade Timberlok/Ledgerlok screws @ 8"o.c. Add Simpson DTT2Z tension ties @ each corner&8'-0" max in between on the decks/sunroom with %"x4"L lag screw to ledger/rim joist. 3. Add Simpson H2.5A from each joist to end beams. 4. Clamp all (3)2x8 beams and stitch screw with '/<"x4"L Exterior Grade Timberlok screws @ 8" o.c. staggered each side. 5. Add 2x6x18"L post/beam gusset each side of post with (3)%"x4"L Exterior Grade Timberlok screws staggered to beam and @ 6" o.c. staggered to post. Provide shim as required at beam. At the sunroom, a single gusset may be used where fascia/rim is present. 6. Add P.14x424"L knee braces from all posts to beams, attach with (2)'/<"x6"L Exterior Grade Timberlok screws each end. 7. Clamp and install %"x4"L Exterior Grade Timberlok screws @ 4" o.c. staggered at all post splits greater than 3/16" (perpendicular to split, extend 12" beyond split). This memo is to serve as official FOR approval that the existing deck is adequate once the above recommended upgrades are completed. If there are any questions regarding the above statements, feel free to contact me directly. NKH Engineering I www nkhengt n@-erinQ.com 1 206-601-9728 u S A tJ L1. �511,�� i ,3 0,7 So uk 2)n S7=' � / J��i/�I i►:' W `-f'— 3 3 / QA MASON COU NT'f PLANNING ALL SETBACKS ARE MEA6URED FROM THE FURTHEST I � FROJECTION OF THE BUILDING SHED / i I f /J e � APPROVED MASON COUNTY DCD PLANNING S TE PLAN R U UIRED TO BE ON SITE / �� T TO APPROVAL / By CHANGES Date -Z(VLLU I 'Y / SHE / 112 OP OF BPEAK HAVEN LAKE uzr 49. / 218 1 ' PLAT OF HAVEN LAKE 1 / 1 / 1 / 1 1 1 US252532 - Sue Sargent / Brian Meaker , ------------------------------------------------------------ Sep. 20, 2011 �w' r O1 fl 1WfVED r Name SuSA1j �/s ' flAyz r``ns iT Parcel# 2 23 1q 5'ccv--,1l'2-- BLD#� Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 7Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. Tom=Calculate lmpeni►ous Surfaces P eas,6 Corn fete This Tab? Surface Type Length X Width = Area `All dimensions in feet Buildings ggX 3� = 16 7 2— l,t pi1, X _ � Measurements for buildings are taken at the perimeter of the farthest projections(example: X = eaves/gutters) X = Driveways X = X Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks 0 g5 X = X = Any paved, gravel or packed area per definition above table X = Others X X = ifae total impervious area-of the proposed site X = development is:greater than.2000 square fleet a all Parcel.$tormwater.Site Plan:is Required Total Impervious Surface Area(sum of all areas), If the Total Impervious Surface Area is LESS 20 0 S u Re please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further ac owledge that the info ation provided is accurate and employees of Mason County are granted access to the above- descnb roperty for e and' pection as ma e required. 6 X '—a�,, . Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface a is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management ApplicatiowWorksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48.section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850,Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has, or wilt have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I fi.uther acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 I N G MASON COUNTY PERMIT NO�0 Cq I( L BUILDING PERMIT APPLICATION _ 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-526 - On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION -� Owner .� J Company Name rUj v1 e- J Mailin Address L. 1 2-1 � .} Mailing Address City tADIAt'57 State Zip Code City State Zip Code Phone F cb� 9" `f -39 3 3 Other Ph. Phone Other Ph. Lien/TAP Holder I " e- Contractor Reg. # Exp. E mail addressa%AVJ�92N r_- ','I2BO 1 E Mail Address Drivers Lic.# � `s' cl Drivers Lic.#_ DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic— Existing Septic Connect to Water System . Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No. 49,3 ( 1_5 Oy tJ 9 1 Fire District Legal Description Site Address (Please include street name, street number and city) 2�'1 Cf `►r 1-�uv I�IGtikYr�i"��� {��a t3cJ �` Directions to site u � -L" `_8i r" 1 c e Will timber be cut and sold in parcel preparation? Yes Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs ] 15% .D,,,Zi Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yesoo TYPE OF JOB - New Add Alt Repair Other P IMARY RESIDENCE SEASONAL Use of Building k=�C)i Describ�-e��lV'ork ,t No. of Bedro9 s�_No. of B throoms�, Square Footage- 1 st Floor5 2nd Floor - 3rd Floor N Basement — Deck Al_Covered Deck 5 Othe 12i-0- ft i Garage_ Attached Detached Carport Attached etached MANUFACTURED HOME INFORMATION -Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspectiog. PROOF F CON-nNUXqON qF WORK IS BY MEANS OF A PROGRESS INSPECTION.. a Yt 1�r1 Dae & J2- h/Iel�c'-Gtye r0 clp_�X wftoners Reresenta e/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: 1 Date - DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department _ In(a -Wn 3 Environmental Health Department Public Works Department ;. Fire Marshal , . FEES P Building Permit Fee Site Inspection Plan Review Fee /{o $. d EH Review Fee Plumbing& Base Fee / . L10 'f >l 4. C) Planning Review Fee Mechanical & Base fee " !(> - e,5 Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal —7 IL Valuation$ TOTAL FEES t4slo 7a �30 sr � 538 M UP �f 5�` 5�7 79, �Y)Yr� I I X 8 8g MASON COUNTY PERMIT NO. I� � BU,ILDIN-9fiBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar•P.O. Box 186, Shelton, WA 98584 Shelton(360)427-9670•Belb (360)275-4467•Elma(360)482-5269 On the we www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner SviSA1J s1, 6.AR6EN7- Company Name Mailing Address 302 Soi17n 210-O Mailing Address City P iS m e t nl E>; State W_Zip Code l8 I l`>? City State Zip Code Phone-''�-O& .-f2q -3433y Other Ph. 2C'f, 290 -94 12 Phone Other Ph. Lien/Title Holder Contractor Reg.# Exp. E mail address SltcsaLja"+a msrJ. (.cW4 E Mail Address Drivers Lic.# IliDOB $<<'i 1 6`L Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No, Fire District Legal Description Site Address (Please include street name, street number and city) Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB -New Add Alt Repair Other Use of Building Location of Fixtures/Units- 1 st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL`JJ.NITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG_Natural Gas_Heat Pump_ Toilets Tvoe of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs �_ Heatpumps Showers Spot Vent Fan Water Heater I Propane Tank Clothes Washer I Gas O is lU Kithen Sinks 1 Woellet Stove Z Dishwasher I KAc;he aust Hood 1 Hosebibs Dryer Vent 1 Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grapts employees of Mason County access to the above described property and structure for review and inspection. PROOF QF CO U O WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date:_(, Z— Owner/Owners Representa' /Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted b 'Planning Pd Ck# Date Zld Pd Receipt No. DEPARTM NTAL REVIEW APPROVED DENIED NOTES Building Department Occ GroupType Constr. Planning Department Environmental Health Department FEES Plumbing& Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Volation Fee TOTAL FEES MASON Mason County Pen-nit Center Use: DEPARTMENT OF COMMUNITY DEVELOPMENT DDR - DOG i C 411 N. Fifth Street/P.O.Box 186,Shelton WA 98584 n 360.427.9670 ext.352 Date Rcvd Request for Administrative Variance for Reduction in the Required Setbacks ($115.00) For administrative review, the minimum variance on a setback request is 5 feet from the side yard lot lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction requires a standard variance. Setbacks are measured from the furthest projection of the structure, including roof eaves. Applicant/Owners: L),S a- O i' Y' Mailing Address: 30 �. 4 0 City:_1 : M, I l<Dlfttf j State: Zip: Telephone: l � 1 �Z4 ? GI �J CeJ ( Co�Z-! Email: If this reduction is tied to a buildin permit, please gi a permit case number. BLD '0012 - 003(6r Parcel Number(s): 1 ( Z Zoning Site Address: 2-0 10 ME Ril aAD TAt+uvAl WP'T I8-$ Requested setback variance: /0 ft. V Front ❑ Rear ❑ Side ft ❑ Front ❑ Rear ❑ Side ft. ❑ Front ❑ Rear ❑ Side ft ❑ Front ❑ Rear ❑ Side Front Setbacks—From access easements and road right of ways. Minimum 10 feet. Rear Setbacks—From the rear property line. Minimum 10 feet. Side Setbacks—From the side property line. Minimum S feet except for certain shoreline designations. An illustrated site plan is required. Your site plan must show the following: north arrow, abutting street or easements, set backs to all property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic,well and driveway. Show all proposed new development. 1ACommunity DevelopmenAPAMARIANCEMAdmin Variance.doc Edited on 7/16/10 FRONT AND OR REAR YARD REDUCTION REQUESTS: For existing lots of record as of March 5, 2002; You must meet one of the following: 2) One of the following exists on the lot(check all that apply): iff a) steep slopes,wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ c) lot width at the front yard line of no more than 50 feet; ❑ d) lot size of no more than one-fourth acre; ❑ e) existing improvements of buildings, septic systems, and well areas. SIDE YARD REDUCTION REOUESTS: For existing lots of record as of March 5, 2002; You must meet one of the following: 2) One of the following exists on the lot(check all that apply): ❑ a) steep slopes, wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ c) lot width at the front yard line of no more than 50 feet; ❑ d) lot size of no more than one-half acre; ❑ e) existing improvements of buildings, septic systems, and well areas. Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard for Rural Residential 2.5, 5, 10, or 20 zones. �E Sal BACI< /H{ L4KE ANA Yes �ECGTMR`' a GLACE `� 41nme closer 4an 1t 6 Z5 bo i SET 196c Kn, Owner/ gent(please indicate) /OLZ7_1�Signatur O rcial Use Onl Approved by: Date Denied by: Date Reason for denial: 1ACommunity DevelopmentTAOVARIANCESWdmin Variance.doc Edited on 7/16/10