HomeMy WebLinkAboutBLD2018-00245 - BLD Plot / Site Plans - 12/30/201840'-O"
20'-O"
20'-O"
UNIT A
4x6 POST
DESIGN DATA:
r
I
111
1
EXT&. BASEMENT FLOOR PLAN
14" = 11.011
000E
lnl I ND SPEED
SEISMIC ZONE
SNOW LOAD
SOIL SRG
FROST DEPTH
2015 - IRC, IMC, UPC, INSEC
110 MPH
0-2
30 PSP
1500 PSF
12" TO SOT OF FTG
1125 50. FT.
O
m
GENERAL NOTES:
UNIT S
DECK
EXTG. MAIN FLOOR PLAN
14" = I'-O" 611 50. FT.
I. PLANS DESIGNED ACCORDING TO THE 2015 IRG.
2. CONTRACTOR TO CHECK AND VERIFY ALL
DIMENSIONS BEFORE PROCEEDING.
3. CONTRACTOR TO CONFIRM THE SIZES, SPACING, AND SPECIES OF LUMBER
OF ALL STRUCTURAL AND FRAMING MEMBERS.
WINOOYVS:
I. THE CLEAR OPENING OF WINDOWS IN SLEEPING ROOMS SHALL NOT EXCEED
44" FROM FINISHED FLOOR.
2. ALL WINDOWS TO BE DUAL GLAZED
3. ALL GLASS IN A DOOR, NEXT TO A DOOR W/I 12", OR
W/I IS" OF FLOOR OR IN/I 60" OF TUB/SHWR VERTICALLY OR HORIZONTALLY
TO BE SAFETY GLAZED, OR ANY OTHER HAZARDOUS AREA PER IRC.
VENTILATION:
I. VENT D.W. go SINK
2. VENT DRYER OUTSIDE IRC MI501.1
3. VENT H.W.T. TO EXPANISON TANK
4. VENT ALL FANS OUTSIDE IN/ 3' MIN. TO BLDG. OPNG OR
5. KITCHEN RANGE VENT TO BE MIN. 100 GFM
6. PROVIDE WHOLE HOUSE FAN
1. PROVIDE PROPER ROOF AND CRAWL SPACE VENTILATION PER IRC
Option
4C
Glazing
Area %
of Floor
Unlimited
Fenestration
U-factor
Vertical
(Includes doors,
windows, etc.)
.30
Skylight
.50
Ceiling
R-49
Vaulted
Ceiling
R-38
Wall
Above
Grade
R-21
int KI
MECHANICAL $ ELECTRICAL:
I. LAYOUTS INCLUDED IN THIS PLAN SHALL BE INTERPRETED A5 SUGGESTED
MECHANICAL AND ELECTRICAL LAYOUTS. FOR PRECISE SPECIFICATIONS
CONSULT A PROFESSIONAL MECHANICAL 4 ELECTRICAL CONTRACTOR.
2. SMOKE 4 CARBON MONOXIDE DETECTORS SHALL RECEIVE PRIMARY
POWER FROM BUILDING WIRING IN/ BATTERY BACK—UP 4 SHALL
BE INTERCONNECTED TO BE AUDIBLE THROUGHOUT BLDG.
3. VERT. DIST BETWEEN GOOK TOP OF RANGE AND HOOD
SHALL BE NO LESS THAN 30"
4. HINT SHALL BE ANCHORED OR STRAPPED FOR EARTHQUAKE 4
PLACED ON R—I0 PAD IF LOCATED IN UNHEATED SPACE OR CONC. FLR
5. T4P HINT TO OUTSIDE
6. PROVIDE OUTSIDE COMBUSTION AIR FOR FURN PER IRC GH. 17
MISCELLANEOUS:
I. PROVIDE Q0# FELT BETWEEN POSTS 4 GONG.
2. ALL STAIRWAYS TO HAVE MIN. 6'—S" HEADROOM CLEARANCE $
STAIRS, RAMPS, AND LANDINGS ABOVE 30" REQUIRE 36" RAILING
3. ALL EXTERIOR DECKS AND PORCHES TO BE CONSTRUCTED
WITH PRESSURE TREATED WOOD
4. 22"x3O" ATTIC ACCESS REQUIRED IF ATTIC VERT HEIGHT 15 30" OR MORE
5. ALL DEFORMED REINFORCING STEEL SHALL BE
ASTM A 615 GRADE 60 Fy = 60/000 PSI
Wall
int ° n below grade
10/15/21 int +
TB
Floor
R-30
Slab don
Grade
R-10, 2 ft
Heated slabs
require R10
full slab.
40'-O"
20'-O"
20'-O"
4/o 5/o SH 4/o 5F/a SH 4/0 5/o SH
12' DOOR SYSTEM
EXISTING
4x6 POST
FURR IN WALLS
/FOR R-21 INSULATION ■
I
'6/4V
6'-q2
KITG
I10V G.M.
5D.
N
I REF I
1 1
L---J
IOOcfm
O®O
I I'-102"
II
II
II
� I
JI
\
1
II
SAFE
2/o 4/o
UNIT'A
LIVING RM.
I5'O "x22'8"
0
,/
\ / 1
'trq
7
/1
0
/0 4/o SL
FURR WALL TO OUTSIDE
FOR R-21 INSULATION
6Ocfm
0
BEDROOM
20'-O"
201-O"
40'-0"
LEGEND
EXISTING
REMOVE
NEW
40'-0"
20'-0"
20'-O"
0
m
1
zEF
1
O
O
OOcfm
60cf
I 4/4-5/6 SH, I
SAFE
UNIT
LIVING RM.
1q16"x15'5"
2/S
8'-4"
I® ®•
5D.
III
u
I®
5D.
51-0"),
3%�
4
GLST
m= _
6/o BP III
1
BEDROOM
TOE f-m =
T,i -m
D i E&RES5 in
20'-0"
0
i
N
20'-O"
4/o 5/6 SL
20'-0"
40'-O"
UNIT A UNIT B
NEW BASEMENT FLOOR PLAN
111 = II_O11
III 1 SO. FT.
NEW MAIN FLOOR PLAN
4" = 1 '-O" 616 SQ. FT.
I
FRONT ELEVATION
14 11 = I10 II
REAR ELEVATION
RIGHT ELEVATION
4 u = I I_Qu
LEFT ELEVATION
:;:d3
v
m
( s
O
_v
= o
O <
d
O 1
0- •
r
g
z g
• d3
w Eg
in R o i
tfa NE
11
kW
0
hi
34" 1:
PEr
d144,