Loading...
HomeMy WebLinkAboutBLD2023-00373 - BLD Application - 5/24/2023 If , ilr+.- J. MASON COUNTY BLD R� � 111111 COMMUNITY DEVELOPMENT aoaa-�7�� Permit Assistance tenter,Building Planning RC Y: MAY 2 4 723 1' ' 1FJ APPLICANT INFORMATION(please print clearly) 11 € I :' v J } Name of Applicant: Sheila Swalling, Swalling Walk Architects Parcel Number: 52004-50-00037 Site Address: 421 W Nahwatzel Beach Drive, Shelton This checklist must be completed and signed by the owner or owners authorized agents at time of submittal. Incomplete applications will NOT be accepted. For a complete application, all items on this checklist shall be submitted, unless waived by Staff. PERMIT APPLICATION N/A Provided Staff Provide a completed and signed(by owner or authorized representative)application ❑ 0 and applicable fees are due at submittal. Provide a com 8leted .lumbin. and Mechanical A$rlication 0 0 SITE PLAN Provide one(1)copy of proposed site plan. Drawn to scale of either ❑ 0 1"= 10' or 1"=20' depending on lot size. North Arrow,location and dimensions of all property lines and easements. 0 _ 0 Vicinity map showing location and names of all roads and easements.(public and ❑ 0 private) _ Show distances to all structures,septic tanks,drain fields,property lines,top of ❑ 0 slopes or cuts and easements. Zoning(indicate): Rural Residential: ❑2.5 0 5 ❑10 ❑20 ❑Other: IME Urban Growth Area: Zone: Front yard: Direction: Side yard: Direction: Rear yard: Direction: Side yard: Direction: All access points,width of access.(easements and driveways). 0 0 Contour lines in twenty(20)foot increments. See Parcel Map Viewer on website 0 0 Building height shown on elevations at all four corners of structure. ❑ I] Floodplain boundaries and setback distances. See Plans for additional requirements. 0 ❑ Wetland or surface water(if any)and any applicable buffers. If yes,a wetland 0 ❑ report may need to be submitted. Is the site near a Shoreline(stream,creek,lake,saltwater)if yes,please indicate? 0 0 Name of shoreline: Nahwatzel Lake Shoreline designation: Stream type(F,S,Ns,Np): 1.= Is the proposed site within 300 feet of a slope 15%of greater?If yes,a geological 0 ❑ report or assessment may be required. Existing/proposed on-site septic system and reserve areas, providing setback to ❑ 0 structures. Existing/proposed wells(show 100 ft well radius,with distances to structures). 0 0 Existing and proposed stormwater controls(downspouts,dry wells,etc.) 0 0 Exterior stora a tanks ro ane and HVAC a ui ment. 0 El PLANS N/A Provided Staff Provide two(2)copies of plans(1 full size min. 18"x 24"and 1 small size)and 0 0 one(1)copy of all specifications and engineering.Plans must be drawn to scale of ''A"= 1'.All notations and drawings must be clear and legible.All Engineering ❑ ❑✓ callouts must be on plans. Engineered plans must provide calculations/analysis.Analysis must include the following information: • 2018 International Building Code • Snow load(by location) ❑ ✓❑ • Seismic zone(D-2) • Exposure(by location and topography) • Wind speed(85 MPH basic and 110 ultimate w/3 second gust) If project is in a flood hazard area,the submittal must include an Elevation Certificate,flood venting compliance and an elevation detail indicating the location ❑ of finished floor relative to the Base Flood Elevation or Design Flood Elevation as designated by surveyor or engineer. FOUNDATION PLAN Plan view of foundation/footings/pads ❑ 0 Type,size and location of footing(stepped foundation provide detail) ❑ 0 Elevation view of foundation steps,with final grade ❑ ❑✓ _Cross-sections of footing and foundation(including height of wall). ❑ ❑✓ Floor joist and spacing(each floor). ❑ ❑ Show location of flood venting and detail the method and compliance for venting. ❑✓ ❑ Type and locations of hold-downs and anchors. ❑ ✓❑ Crawl access location and size. ❑ 0 Insulation value for foundation(if slab or basement).See Energy Credits for ❑ additional requirements,credits must be indicated on the plans. If project is in floodplain provide flood venting compliance including vent locations,vent type,elevation detail for venting location interior and exterior of the 0 ❑ crawl space. FLOOR PLAN Square footage of each floor 0 0 Use of each room 0 ❑✓ Location and size of attic access ❑ 0 Dimensions of building and rooms. ❑ 0 Location and type of furnaces,water heaters,smoke detectors,and carbonEl ❑ monoxide detectors.Include location of bollard for appliances located in garage. Plumbing fixture locations ❑ ❑✓ Location of doors,windows(include size,egress,tempered and skylights) 0 ❑✓ Insulation value in floor. See Energy Credits for additional requirements,must be ❑ 0 indicated on the plans. Location of ventilation fans and CFM for each. ❑ ❑✓ Location of whole house fan and CFM(continuous or intermittent) ❑ 0 Location,side and type of brace wall or shear-wall panels. If structure is ❑ engineered,must supply two copies of required analysis(calculations) Dimensions and framing details of decks(including joists,beams,posts,ledgers. El Plan MUST include size,grade,spacing, length and species or type of material) ELEVATIONS AND WALL DETAILS Typical and rated walls(garage separation) 0 ❑ Listing of fire-resistive wall designs(duplex or townhouse) ❑✓ ❑ Building elevations-all 4 sides Show distance from grade at each corner. 0 0 Exterior wall details when distance between overhangs is less than 5 feet. ❑ ❑ Insulation value for walls.See Energy Credits for additional requirements,must be ❑ 0 indicated on the plans. If project is in floodplain must provide Elevation detail indicating the location of 0 ❑ finished floor relative to the Base Flood Elevation or Design Flood Elevation as designated by surveyor or engineer. ❑✓ 0 ROOF PLAN Layout of roof system ❑ ❑✓ Label type of roof system,rafters,engineered trusses&spacing ❑ ❑✓ Headers noted at each location or typical header noted. ❑ ❑✓ Roof pitch and covering materials ❑ ❑✓ Sheathing types,dimensions and fastening 0 ❑✓ Attic venting(type, location and amount) ❑ 0 Insulation value for roof(R38 vault and R49 ceiling) See Energy Credits for ❑ addition ref uirements,must be indicated on the clans. ENERGY CODE REQUIREMENTS N/A Provided Staff Completed Washington State Energy Code form ❑ ❑✓ Plans must indicate fuel source for furnaces, water heaters and other appliances. ❑ ❑✓ Manufactures Specifications for each unit or component for HVAC&plumbing ❑ ❑✓ Compliance to the Washington State Energy Code and required Credits. Construction drawings/plans MUST include all credit information on the plan ❑ details such as insulation,ventilation,furnaces,windows etc. Plans must also include the number of credits and which credits are chosen. I verify that all required documents, plans,and specification associated with this application have been submitted and are accurate. (bobby ogned by Shelia K Swali g Sheila K Swallinge �sl°°� Sheila Swalling DatSignature of owner or authorized agent Print Name Date