HomeMy WebLinkAboutFIR2004-00020 - FIR Plot / Site Plansr pitcher 2011 1 1f 1 11 _ i N en 203 Eni Women 202 Neetinc Rm. [2oQj 15cd N4- 15cd N4-3 Main Floor Fire Alarm Plan 118" = 1, - 0" _ _ NMI 110cd 11 vech. Rill. 1 L_N2 J vlech. Rm. 113011 Mezzanine Fire Alarm Plan Lobby 7-4 EOL Admin. IFr 0 -11 Office [209 Training L210 1 Hallway 212 Closet [213 1ST Cont. Rm. L216 -1- 11 u (E) Office 20 7] Office L2C8:1 Communications 7.11 0 Toilet [214J Janitor 215] Decontamination [217 (E) (E) (E) F Storage 1Q1J '-1 • (E) Apparatus Says [no _ (E) — — (E) Zone Descriptions 1. Sprinkler Waterflow. 2. Sprinkler Tamper Supervision. 3. Sprinkler PIV Tamper Supervison. 4. Apparatus Storage Heat Det. and Pullstation. 5. Apparatus Pullstations. 6. Office Area Smoke Det.(s) and Pullstation(s). 7. Meeting Rm. / Kitchen Pullstation(s). 8. - 10. Spare(s). (E) (E) (E) (E) (E) Hose Tower � 103] r- (E) (E) (E) _ (E) Wire List A Inflating Zone (2) #18 AWG. FPLR (Fire Rated Cable) B Notification Appliance Circuit (2) #12 AWG. FPLR (Fire Rated Cable) 10 9 8 7 (EXISTING) Silent Knight 5208 Fire Alarm Control / Communicator 31X RJ 31X Fire Alarm Riser Diagram (E) (E) N.A.C. #2 (E) N.A.C. #1 Apparatus Area (E) (E) (E) A (E) N.A.C. #3 Office Area N.A.C. #4 To Alarm Center, Inc. for UL cental station monitoring. To dedicated AC circuit. Symbol Legend Make/Model # Fire Alarm Control Panel (EXISTING) Silent Knight 5208 FA P 0 Photoelectric Smoke Detector (EXISTING) © 135° Rate of Rise Heat Detector (EXISTING) F ; Manual (wall Back mount Box: Pullstation top Standard of device 2 gang @ 48" with 1 A.F.F.) gang m.r. (NEW) Silent Knight PS -SA 4 F I(wall Horn/Strobe cd Back = candela mount Box: rating Standard Combination bottom of of strobe 2 device gang light with @ 80" 1 gang A.F.F.) m.r. (NEW) Gentex GEC3-24WR 2 i xxcd Strobe (wall cd Back = candela mount Box: Light rating Standard bottom of of strobe 2 device gang1 Iight with @ 80" gang A.F.F.) m.r. (NEW) Gentex GES3-24WR 3 0 F I 10" Bell with Ajacent Strobe Light (EXISTING) © Sprinkler Waterflow System Alarm Switch (EXISTING) © Sprinkler Supv. System Switch (EXISTING) Tamper © Sprinkler Post Ind. System Valve Tamper Supv. Switch (EXISTING) EOL Indicates End of Device (E) Indicates Existing Device 44LE coPY APPROVE MASON 0u FI E !ARSHA DATE 12:3 BY SUBJECT TO FIELD INSPEC TIO ALL APPLICABL CODES SHALL APPLY- ERRORS AND/OR OMISSIONS ON PLANS ARE SOLE RE- SPONSIBILITY OF OWNER/CONTRACTOR. CORREC- TIONS REOUIREo FROM FIELD INSPECTION SHALL SE AT OWNER/CONTRACTOR'S EXPENSE. THIS AP- PROVAL DOES NOT GRANT TO ANY PERSON THE RIGHT TO VIOLATE ANY CITY OR STATE LAWS. Project Name: Mason County Fire Protection District #18 New Fire Station Phase III 240 N. Standstill Dr. Hoodsport, WA 98548 A co fir Date: 4/5/04 System Type: FIRE ALARM Scale: As Shown Contractors ALARMCI055CW License # Drawn By: J.F. Approved By: Date Revision Date Revision ACE FIRE & SECURITY SYSTEMS A Division of Alarm Center, Inc. P.O. BOX 3363 LACEY, WA. 98509-3363 1-800-354-1555 SHEET NO. FA-1 1 OF 1