Loading...
HomeMy WebLinkAboutSWG2023-00229 TANK ONLY - SWG As-Built - 8/3/2023 Ta /( Only 4bt' H- Mason Re ol County OSS Installationp pg. 1 MASON COUNTY PUBLIC HEALTH APPLICANT/ PERMIT INFORMATION Permit Number SWG 2023-00lla1 Parcel# 2 Z e I g -5( - (> 112 Applicant Name Robext Pad Subdivision (Name/Div/Block/Lot) Applicant Address 50 E SInciaiV H Tin'l6etXI ' t3 LOI- IIZ+ '/f4 int Iof IIE City, State, Zip .Shelton, WA c;185gu Installer Name ta,pl e - 6 XCel yowl Site Address 50 E sinCair PI. Designer Name INSTALLATION CHECKLIST 11 ❑ Full System Installation ❑Tank(s)Only ❑ Drainfield Only ❑Repair [Other t if Station System Type el oVttV Pretreatment Type >5 ft. from foundation? - - ❑ N/A ❑YES ❑ NO >50 ft. from wells? - - ❑ ❑ ❑ z• >50 ft. from surface water? - - ❑ ❑ ❑ a Cleanout between building and tank? - - 0 0 ❑ U Tank baffles present? - 24" access risers over each compartment? - - ❑ ❑ ❑ a. ❑ W Effluent filter installed?- ❑ ❑ rn Septic tank size gal Manufacturer C] D-box water level and speed levelers used? - • ❑ NIA ❑ YES ❑ NO X—I ❑ ❑ �O Manifold/D-box accessible from surface?- - ❑ m 2 Check valves installed? - - ❑ ❑ ❑ a Q Schedule/Class 2 Transport Line Size Bedrooms installed (check one) 2 ❑3 ❑4 0 5 0 6 ❑Commercial/Other >10 ft. from foundation?- - ❑ NIA ❑ YES ❑ NO • >100 ft. from wells?- - ❑ 0 ❑ W >100 ft. from surface water? - - ❑ ❑ ❑ E. >10 ft. from potable water lines?- - ❑ ❑ ❑ Z > 5 ft.from property lines and easements?- - ❑ ❑ ❑ Q ❑ re > 30 ft. from downgradient curtain/foundation drains? ❑ ❑ O ❑ ID level and observation ports present ❑ ❑ Graveless chambers or ❑ Clean gravel used? (check one) Proper cover installed over drainfield?- - ❑ ❑ ❑ Pump tank setbacks consistant with septic tank? - - ❑ N/A 'YES ❑ NO Pump tank size gal Manufacturer-z.oealex Z ❑ Q 24" access riser(s) and accessible from surface? 0 ❑ ~ Alarm or Control Panel Installed? - a- 0 ❑ E] Control Panel equipped with Timer/ETM I Counter- D a• Pump installed in ❑ Bucket or On Block or ❑ Other Floats F r 3_ Pump Make/Model Ai t'a fJ� � j_; in/min Pump capacity gpm Squirt Height ft d Tank draw down Height II IIrr nn A Pump on time Pump off time Daily f16 5`4tOa3 2023 gpd MASON COUNTY Updated 8nl/2018 DJA ENVIRONMENTAL HEALTH 7 I( oti1y / 5b( 1t Mason County OSS Installation Report pg. 2 Parcel # 2Z618-bt' 001 4 Z ABANDONMENT RECORD Were existing septic components abandoned as part of this project? - - YES IA NO If yes, please describe. Were all components pumped out and properly abandoned per WAC246-272A-0300? - YES NO RECORD DRAWING This is a permanent record and must be accurate and descriptive enough to re-locate in the need of maintenance activities and future development. Typical Record Drawings contain: Drainfield 8 manifold orientation&layout.Seplidpump tank location,Nor:n arrow,reserve drainfield,existirg and proposed buildings,location of wells,waterlines, wells,observation ports.cleanouts.and other maintenance access points. Incomplete Record Drawings may create additional delays in final Installation approval and related permits. [Record Drawing Attached CERTIFICATION OF INSTALLATION INSTALLER DESIGNER/ ENGINEER 1 certify that I installed the system in accordance with 1 certify that the system has been installed in accor- the septic design stamped"APPROVED"by Mason dance with the septic design stamped"APPROVED"by County Public Health and that any deviations shown Mason County Public Health and that any deviations here have been cleared/approved by both the designer shown here have been cleared/approved by both and Mason County Public Health and meet all State myself and Mason County Public Health and meet all and Mason County Codes. State and Mason County Codes I further certify that all information contained on this i further certify that all information contained on this form and attached Record Drawing is accurate. form and attached Record Drawing is accurate. Signature of installer Date .Chain t iavele Pnnted Name of Signee MASON COUNTY PUBLIC HEALTH The undersigned approves this Installation Report and Record Drawing on behalf of Mason County Public Health: Signature of Environmental H pe aliR Oe HA (stamp, signature and date) THIS FORM MAY BE SCAtAtP61Dy,il.ffB LE FOR PUBLIC VIEW ON THE MASON COUNTY WEB SITE Updated 3121/01S MASON COUNTY ENVIRONMENTAL HEALTH DJA Tovi/L 0171fri5b !fi RECORD DRAWING (continued) 46 -01 .42 CS tc- v � APPROVED AUG 0 3 2023 MASON COUNTY ENVIRONMENTAL HEALTF DJA • q JUN 14 2023 ,, r, ° Y' n r�_ ;r / MASON COUNTY ENVIRONMENTAL HEALTH ,0 9 r; RET 3 Y0 � rl ' �' - :' 'I /.� �i ,J'/J JJ .F-' F A./ 5 • Z < '46.?,1, \ 1-1 dy -4--,ir,(L-i -, 1-1 • / ri -t) Rxss 'ti /. /. xi r 8>3. 9L.9S(W ■■ .d i / T5t AND n co �9. ea 9 s y 1L .)./a� 0 o f ' • C 5.A °f A D �s l % • / om Z TDZTc> �'�Q'(14r Jq S. i z �� :::/.4 ` 1, i • 0 • ��z Z \k,S1_, Y,r��j \m z npDlnPG"V WV: I' •`. �m GO n O` O p 'i v • f-I -, a 0.• V �1l o �N N by f <F .p G rrl -}. m I y�o _ 2 (n..u. 51f' N<•o �Co 0 N O 0c. O O O, 1,1* GAF G/V!O P�. �11 1 CO i N co p nga T O "�, t�4% O co �o x a y0 1)<6 c0 • a"�' s A WO X ,., . —On, a 3 = oc � 3 m A n SFOFA�T�4 •s x i x, = D CP O p 111 > a 24 KN m0 O �� jaw '0 o Z F `q n o 70 =mv m 's N N 0 o4 o D a`a 0 $cam o r s Cn C —r co { Z O s n� a,✓ Vutei !` 1126 t( SECTION:2.45.054 Trusted.Tested.Tough! l FM3292 PIZ �fR Product information presented 0121 here reflects conditions at time IMNISupersedes rofe MP COMPANY L Lrl�publication.Consult factory regarding discrepancies or New inconsistencies. AUG 0 2 2023 TECHNICAL DATA SHEE RECEIVED NEW 912 PACKAGE SYSTEMS PREASSEMBLED SEWAGE SYSTEMS FOR FAST INSTALLATION. PUMP SPECIFICATIONS Voltage 115 28-3/4 Phase 1 O Hertz 60 / ° I— RPM 1400 or 2800 / ° O • O Type Permanent split capacitor f • f Insulation Class B fr�•, 7 `� " 4-1/2 Amps 4.4-8.5 0 +l. ./' Operation Automatic / t Auto On/Off Varies based on package O //, Discharge Size 2"NPT • ° • z f Solids Handling 2"(50 mm)spherical solids CI. '�I Cord Length 20'(6 m)standard Max.Head 14'(4.3 m),22"(6.7 ml,45.6'(13.9 m) --•- 22 .1 r 5/8 d 92 GPM(20.9 m'/hr),106 GPM(24 m'/hr), I tj Max.Flow Rate 149 GPM(33.8 m'/itr) �r�t�� T Ti,�l<•.r } 1 Max.Operating Temp. 130°F(54°C) I � I 1 Cooling Oil filled -- Motor Protection Auto reset thermal overload CI 9-1/4 Cap Cast iron !`� jam. :--- 1 Motor Housing Cast iron 25-1/2 r(iV Pump Housing Cast iron I."I Base Engineered plastic or cast iron �1 '_=�= J Upper Bearing Sleeve bearing _ r III Q Lower Bearing Sleeve or ball bearing SK3309 W Mechanical Seals Carbon/ceramic ~ Impeller Type Non-clogging vortex 24"x 24"(61 x 61 cm)shown,18"x 30"(46 x 76 cm) Q and 24"x 36"(61 x 91 cm)also available. 2 Impeller Engineered plastic Hardware Stainless steel 1215 cold rolled steel,1144 steel or JIS APPROVED Motor Shaft S45C steel Gasket Neoprene AUG 032023 BASIN SPECIFICATIONS MASON COUNTY ENVIRONMENTAL HEALTH • Polyethylene basin DJA • Polyethylene structural foam cover with 2"vent and 2"discharge • 41 gallon(155 liter)capacity • Integral foam seal IA WARNING(These systems are not designed 61 _ for hazardous environments.Please consult roe^Fh factory for special options and requirements. awe' Lif)Copyright 2021 Zoeller Co.All rights reserved. 502-778-2731 1 800-928-7867 13649 Cane Run Road I Louisville,KY 40211-1961 I zoellerpumps.com rn ct TOTAL DYNAMIC HEAD w w PUMP PERFORMANCE CURVE FLOW PER MINUTE 211/264/266 MODELS 25 MODELS 211 264 266 Feet Meters Gal. Liters Gal. Liters Gal. Liters Q 6— 20 5 1.5 82 310 90 341 115 435 < 10 3.0 53 201 60 227 85 322 v 15 4.6 32 121 23 87 45 170 ¢ 15 Shut-off Head: 19.5 ft.(5.9m) 18 ft.(5.5m) 20.5 fl.16.2m) z 4— 0 a 10 I- 0 264 266 2— 211 5 0 20 40 60 80 100 120 140 GALLONS LITERS 1 1 I I I I 0 80 160 240 320 360 400 FLOW PER MINUTE • 009969 IA CAUTION I All installation of controls,protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including.h6_most recent National Electrical Code(NEC)and d1e Occupational Safety and Health Act IOSHAI. MODEL 264 MODEL 266 413/16- 62144- __ 41316'1122 mel— --— 8-5/16'12n mml on cm) (212n.n) — 61Y37 6.7116'1163 m e] p63 mm) r..— I91\ 4744 7:L� ;">_ 4'':':.",?.A..r..9,,,,ik..y., 4\ .mow-SIM 4,1 -2'NPT �Q�i f NPT /�^— I IIir 14.114'1363 raml =1� 7 � ALII 6-7/1B'1163m m) -7�h�� ilia— p65 roll) lI 61r I �II \I I SK.1643 SK1020 See FM2787(model 211),FM2788(model 264),FM2789(model 266)for complete pump specifications. SEWAGE PACKAGES` HPWei Voltage/Ph Amps Discharge Ws/ght Alarm? Model PumpKg 912-1141 M264 4/10 115 V/1Ph 9.4 2" 62/28 N 912.1142 BN264 4/10 115 V/lPh 9.4 2" 62/28 N 912-1143 M266 1/2 115 V/IPh 104 2" 67/30 N 912-1144 BN266 1/2 115 V/1Ph 10.4 2- 67/30 N 912-1147 M264 4/10 115 V/IPh 9.4 2' 62/28 Y 912-1149 M266 1/2 115 V/tPh 10.4 2- 67/30 Y 'CONSULT FACTORY FOR OTHER SEWAGE AND GRINDER OPTIONS. ©Copyright 2021 Zoeller Co.All rights reserved. 502-778-2731 1800-928-7867 13649 Cane Run Road I Louisville,KY 40211-1961 I zoellerpumps.com