Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2023-00340 - SWG Application / Design - 8/10/2023
MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 ,.. .)R, BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT400 x$,•• FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00340 APPLICANT GARRETT MICHELE L Phone: 360-791-4630 Address: 5230 SE ARCADIA RD SHELTON, WA 98584 OWNER GARRETT MICHELE L Phone: 360-791-4630 Address: 5230 SE ARCADIA RD SHELTON, WA 98584 SEPTIC DESIGNER PAULA JOHNSON -Arrow Septic Phone: 360-898-2255 Designs Inc. Address: 171 E VUECREST DRIVE UNION, WA 98592 Site Address: 5230 SE Arcadia Rd Primary Parcel Number: 220303290011 Permit Description: Nonconforming 2BR pressure repair Permit Submitted Date: 08/10/2023 Permit Issued Date: 09/12/2023 Issued By: Jeff Wilmoth Current Permit Fees Paid: $780.00 (additional fees may be required upon installation of system). Permit Expiration Date: 09/12/2024 (based on date of inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY DATE RECEIVED: fra _ I!C)i N D . MASON COUNTY w N COMMUNITY SERVICES AMOlp(OO , IRE WED o N j 7, ,.47.OlO5 (Cot3402iryHealth/Environmental Heahhi - 0���� Ea •r.N.6th Street et 4O&totL W 98S8' er t.60C S VG��`�� O 4, 41 Po.6N Street $heltoM1 WA 9858a J Y V V v_.,. Z `,,3 0 010 l ON-SITE SEWAGE SYSTEM APPLICATION > —A .4ED m m t►"R PHONE r ave Hooker & Michele Garrett (360) 490-5407 Z MAILING ADDRESS-STREET.CITY.STATE.ZIP CODE 0 m Same m SITE ADDRESS•STREET.CITY,ZIP CODE Shelton WA 98584 I N 5230 SE Arcadia Rd NAME OF DESIGNER PHONE I N Arrow Septic Designs, Inc • (360) 898-2255 NAME OF INSTALLER PHONE 0 I o Hanson Excavation, LLC (360) 239-6792 7 Iw PERMIT TYPE(select one) ��+ DRINKING WATER SOURCE ®RESIDENTIAL OSS COMMUNITY OSS L 1COMMERCIAL OSS fff PRIVATE INDIVIDUAL WELL E PRIVATE TWO-PARTY WELL Z I 0 ili PUBLIC WATER SYSTEM TYPE OF WORK(select one) {1t1; I pI ENEW CONSTRUCTION!UPGRADES REPAIR i REPLACEMENT OTHER DETAILS(select aII that apply) 0 TABLE IX REPAIR 0 SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE SUBMITTALS fiE t pp;DESIGN FORM(REQUIRED) SEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE I N 2 2.35 acres r EWAIVER(S)(IF APPLICABLE) 7 I CO DIRECTIONS TO SITE AND SITE CONDITIONS.(ex locked gate) I Take Arcadia. On the right"5230" at mailbox. White house with black trim. Test holes down in back yard. 0 r I o I —a. SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I , OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE(for reporting purposes) ❑VOLUNTARY ❑MAINTENANCE/PUMPING 0 BUILDING PERMIT 0 HOME SALE ❑COMPLAINT 0 OTHER. INSPECTOR SOIL LOGS �p COMMENTS I CONDITIONS // IA _fa /�j� L) V).- 1—C> AA,C444 $ Qo2u23J RECORD D 4y11NG AND I N REPOr SOIL CODES: REQUIRED fOfi FINAL'��1�61MV�^�. V=VERY G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS •ECTOR SIGNATURE DATE APPLICATION EXPIRATION......_ DATE A LAC TION APPROVED!ISSUED BY DATE Gki ANbr' c:2Mg .2.q.....2.st...„( (ALAQ... q- I^ III MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 12/7/2015 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 0 3 0 — 3 2 — 9 0 0 1 1 A design will be reviewed when 3 copies of each of the following are submitted: "#Completed design form that has been signed and dated. ''Scaled layout sketch,including all applicable items on checklist Scaled plot plan,including all applicable items on checklist. °Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X 17" � Designer's SWG ci---3-- we Name: Arrow Septic Designs, Inc Dave Hooker Designer's Phone Number: (360)898-2255 Applicant's Name: 171 E Vuecrest Dr Mailing Address: 5230 SE Arcadia Rd Designer's Address: Shelton WA 98584 Union, WA 98592 City State Zip City State Zip DESIGN PARA1VIETERS Treatment Device ❑Glendon Biofilter ❑Sand Filter 0 Mound 0 Sand Lined Drainfield ❑Recirculating Filter,Type: ❑Aerobic Unit Make/Model 0 Disinfection Unit Make/Model Other: Drainfield Type ❑Gravity RI Pressure gTrench 0 Bed 0 Sub Surface Drip Septic TanWDrainfield Specifications Laterals Number of Bedrooms 2 Schedule/Class 40 Daily Flow:Operating Capacity 180 gpd Length 40 ft Daily Flow:Design Flow 240 gpd Diameter 1.25 in Septic Tank Capacity(working) 1,000 gal Number 5 Receiving Soil Type(1-6) 5 Separation 5 ft Receiving Soil Appi.Rate 0.4 gpd/ft2 Orifices Required Primary Area 600 ft2 Total Number of Orifices 40 Designed Primary Area 600 ft2 Diameter 3/16 in Designed Reserve Area 600 ft2 Spacing 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 200 ft Schedule/Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 2 % Diameter 1.25 in New Slope,If Altered 2 % Preferred manifold configuration used? 6'Yes 0 No Depth of Excavation up-slope 7 in - i Transport Pipe from Original Grade Down-slope 6 in Schedu,e/Ctass. lie w 40 Designed Vertical Separation — 12 , .ri', Leng>`h u�LJJ 130 ft C�O_tional- Dibb3etirsONM—TAL HEALT'� 2 in Gravelless Chambers Required? ❑Yes ❑No p _ Pump Required? Eilf Yes 0 No JB " Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 4 Diff.in Elevation Between Pump&Uppermost Orifice 0 ft Dose quantity 60 gal Drainfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 1,000 gal Lower than Pum Shutoff l 'Pump controls:Please check those required. Uppermost Orifice 0 Higher p G�EIa Capacity @ Total Pressure Head 23.6 gpm Timer pse Meter CirEvent Counter Calculated Total Pressure Head 4.24 ft If Timer: Pump on 2 minutes ,pump off 6 hours Comments Eel -F b re tJ I 0 v--`- -t-- 0 pd DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 0 3 0 — 3 2 — 9 0 0 1 1 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch fli Test hole locations 121Drainfield orientation and layout Reference depth from original grade: 611 Soil logs lig Trench/bed dimensions and lit Septic tank VI Property lines critical distances within layout la Drainfield cover RI Existing D-Box/Valve box locations Existing and proposed wells Reference depth from original grade within 100 ft of property lif Septic tank/pump chamber and restrictive strata: SZI Measurements to cuts,banks,and locations 62( Laterals,trench/bed,top and surface water and critical areas RE Observation port location bottom 0 Location and orientation of Eig Clean-out location 0 Curtain drain collector curtain drain and all absorption lif Manifold placement 0 Sand augmentation components tif Orifice placement Other cross-section detail: Pi Location and dimension of Lateral placement with distance g Observation ports/clean-outs Ig primary system and reserve area to edge of bed Other Information 121 Buildings lir Audible/visual referenced Yes No it Direction of slope indicator litScale of draw' s n on scale lif 0 Design staked out ❑ Waterlines bar 0 !if Recorded Notices attached fig • f %.. �j, 0 Waiver(s)attached Roads,easements,driveways,parking Ok.L 40, ��� 9��k lif 0 Pump curve attached E� North arrow and scale drawing 111, jr \`t;•• CI Evaluation of failure shown on scale bar y" �� '► •'-49 f Non-residential justification 4. PAULA JOY JOHNSON...1'1 0 L'Waste strength S>r bE •IaltIft•' ❑ eIFlow DESK APPRO A The undersigned designer must be n iii..' led by i •Iler time of installation lif Yes ❑ No tillit Si) ature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local siteregulations�� Z 6 • —cz- 3 vir T`, ntal Health Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/7/2015 • Arrow Septic Designs 171 E.Vuecrest Dr. Union, WA 98592 August 9,2023 Mason County Department of Health Services 415 N 6th St Shelton,WA 98584 RE: Dave Hooker&Michele Garrett(Parcel #22030-32-90011)Evaluation of Failure Dear Inspector: Attached is a replacement septic design for a property located at 5230 SE Arcadia Rd, Shelton, WA 98584. The 2-bedroom home was replaced in 2022. The house was tied into the old existing gravity trench septic system at that time. The old system has a homemade 1,200-gallon septic tank followed by a 180 s.f. gravity drainfield. The septic system has been having issues with slow drainage. Upon further investigation, it was found the drainfield is saturated and no longer taking water. The owner has decided to move forward with a replacement septic system. Because of its age and because it is homemade,the existing 1,200-gallon septic tank should be decommissioned or removed and the old drainfield will be abandoned. We are proposing a new 1,000-gallon 2-compartment septic tank with risers and lids to the surface and an effluent filter. It will be followed by a new 1,000-gallon pump chamber. The new drainfield consists of 600 s.f.of shallow pressure trenches using a type 5 soil with an application rate of 0.4.The system will also have a control panel including timed dosing,a counter and elapse meter to prevent overuse and facilitate ongoing operation and maintenance. This is a non-compliant repair with 12"+of vertical separation. The drainfield meets the setback of 100' to surface water and the existing well. We have designated a full reserve drainfield area. The property owner's contact information is as follows: Dave Hooker&Michele Garrett 5230 SE Arcadia Rd Shelton,WA 98584 (360)490-5407 If you need further information,please contact my office at(360)898-2255. Sincerely, ‘ek fi AN% • 4 AppRo , E , 2 2023 03 SEP PAULA JOY y�JOHNSON EXPIRESMASON COUNTY ENVIRONMENTAL HEALTH Paula J. Johnson JBW Licensed Onsite Wastewater Treatment System Designer SE 1\1--CAP \ ik, PLD 3t 0' ' i - 1 i Lf n0 DRIvswPsy C£►^ENZ -•-)f-10—--i.1P e-.-" :L:!:pc...t.,.„-•.,.— 22Y2 .'.4 2 B2 ;Zr. 6AW6E Oli.SE {� \ off >�l. - 1--.— E N`- “., .9 pit :, '..(.. "FL S o a d �3 : tlr M 0 0 ,., ; s ^oar s 7- . 7, n s !-la: PAULA JOY JOHNSON.�'�� he reriove ptPt�E,, IP ct- pY off OMM_ tJ isv0rsed M - �olc1 of +c >re r o3'MiN To pc -...,. a'har2ohe(9.• co r' _ 1 ---- kKe '- Iv) J , , L _ O Audio-Visual Alarm I/ 14 � Cleanout StofssN y °`� 0 1000 Gallon Septic Tank 2-Compartment with N. Effluent Filter 3'' 40' P` ""AY� O4 1000 Gallon Pump Chamber 5' QC W' N O Valve Control Box Scow re ✓JAN. �' i / M ARSI-i 310 , Sc, .LE:1"= 5o' A:TE- ST AOLE o- 25 5o -15 Itoo l.t.. # ,2; 101. SILT LOMA 4- �L 0 t �LPc N `�`0 0-1 S -cc cA0 L\N(7 PARce1-*1-21o30-3L-900 ti p R ® V , 5230 SE. {�R.CNDl N 'Z.aAD SEP 7 2 2023 I •: MASON COUNTY ENVIRONME 4, JewNTAL HEALTH Length Length Orifice # Distance from Distance from Lateral# (In.) (Ft.) Spacing Orifices Feeder Line (In.) Cleanout(In.) 1 480 40 60 8 30 30 2 480 40 60 8 30 30 3 480 40 60 8 30 30 4 480 40 60 8 30 30 5 480 40 60 8 30 30 Total Lateral Length 200 Total#Orifices 40 GPM = 23.6 Dynamic Head Calculations Selected residual pressure: 2 ft. Length (Ft.) #Orifices Transport Pipe 130 40 1.30 ft. Feeder Total Lateral Line Length Lateral#1 40 2 42 8 0.15 ft. Lateral#2 40 7 47 8 0.17 ft. Lateral#3 40 12 52 8 0.19 ft. Lateral #4 40 17 57 8 0.21 ft. Lateral#5 40 22 62 8 0.23 ft. Total Elevation Lift 0.00 ft.ATotal Dynamic Head 4.24 ft. te.. ul 4:- **-7t),), '}' S'QC349 sr) ''1 ' PAULA JOY JOHNSON .?y i ApPROVE,,. •CiC1141801:70 i MgsON COtiSEP Z ?013 NTYENVrRON,�ENTgL HEALTH JB W EALTH 137,, 139, 1 •x 151, 152 : . . Flow-Mate — Dose-Mate or ec iAsoiale,i4 In high head dewatering or effluent This is our fastest growing line of effluent IS. applications where pumping pumps.The 150 series is truly a workhorse performance is critical, this robust designed for reliability under extreme family of pumps is known for reliability, 11 conditions in an effluent environment.150 durability and performance. These series pump curves cover a wide range pumps are especially suited for harsh ( of applications. They are well suited to environments.Zoeller's cool run design M--- applications with low pressure pipe (LPP) and corrosion-resistant,powder coated i� and enhanced flow STEP systems.Zoeller's epoxy finish add up to a long-lasting, cool run design and corrosion-resistant, trouble-free product. powder coated epoxy finish,in addition to I- ' the hermetically sealed,oil-filled motorand Z ` non-clogging vortex impeller add up to a r W I long-lasting,trouble free product. ttli) • 4. l� IP LJL MADE MADE INTtiE USA I U. wc...Am Of mras.nJ W ac APPLICATIONS: APPLICATIONS: G • STEP or onsite applications • STEP or onsite applications • Water transfer • Light commercial dewatering CO • Light commercial dewatering SPECIFICATIONS: SPECIFICATIONS: • 1-1/2"NPT discharge • 1-1/2"NPT discharge • 3/10 HP through 1/2 HP • 1/2 HP through 1 HP • Available in nonautomatic or with a variable level • Available in automatic or nonautomatic piggyback mechanical switch • Model 137,139,140:1/2"(12 mm)spherical solids • 1/2"(12 mm)spherical solids capacity with vortex capacity with vortex impeller thermoplastic impeller • Model 145:3/4"(19 mm)spherical solids capacity with For more information,see Technical Data Sheet FM2784. vortex impeller • Bronze construction available(139 series) • High head version available(145 series) • Double shaft seal versions available for added protection on models 140/145. For more information,see Technical Data Sheets FM2782,FM2783. L f w PUMP PERANCE CURVE lId PUMPPERFCRMANCECURVE MOD 151 152/153 MODEL 1371140f145 50 - 14- 45 153 ' r- ,......... i ....... k o- ,.. b .,........ 12 e. .'........ 35 2 ' p MIIMM ....n.n . 10- 152 ,".....ur 30 151 • , 1" x .■.■I,■,•••"■., r 70; �► _ MI.EP 12 202 1111...1M 111. • `15, .�1191111II► E TY ENVIRoNllIE AL h^ `.,. . ...\►!SIN\.■ JB � .. ....■11►\■. 5 ® ` o �•11�.®11�®® 10 20 30 40 50 60 70 80 90 100 GALLONS .o 1 n ' >c x n w w '' LITERS 0 40 80 120 160 200 240 280 320 360 cxiw :RIM o n s& x< FLOW PER MINUTE 0CA K•�w*t .525`_fi 0,508 8 ©All rights reserved. ZOELLER PUMP CO. I 502-778-2731 1800-928-7867 I zoellerpumps.com , • ---- -- -_-._ ----------------- — • 1 • 1 910.1140 LTD ram GAS TIGHT SEAL I1 24'DIAMETER \ .- • \.! AceEss EWER „...........:..___n t\ . • '... ------. ---.. 1 ' • • , --.- ....... : I ,-, LI-L-1-- TO PUMP —0.1--1-•\---, , ._._____:, ,...-r-r--- / MON SEWAGE a 1 ! 4 1 1 I FLOATING NAT 1 I 1.' i 1 1 14 1 I APPROVED ......, i FILTER - 1 . _ I 1 ' < 1 1 1 I . . sTI 1 1 1 ' reTW ITYPICAL1 secuiga)izsg wyrki CA5 TIENT SEAL TEIREADED i.noist . 24'DUKE= i I ACCESS RISER :1 I FINISH GRADE : 7--- VALVE s 1 : 17 it • , I FROM SEPTIC TANK V ' ''i • •' -4--: O DRADIRELD \ ' i •; i , 1 1 -----r-r- EMERGENCY STORAGE , , 1 1i 1 1 1 i ANTI SIPHON , HIGH WATER ALARM LEVEL Jr T I I" f VALvE z ! i 70 i I i 1 , NORMAL TIMER OFF LEVEL i vicsuam vouita 4---h- • INDEPENDENT T !, II Jr I FLOAT STEM 1; (-•....r r 1 1 FOU FLOAT ENCLOSED PUMP • NOUNTING PPROV, , _ A .....,. t . . SUBMIERSWLE . N COUNT Y ENVIRONMENTA L HE i19434211:T:'1 1 smuDPIA"PC"Plcu. i II cH13:752mEAL*FLAsP:632DEBvtim: SEP 1 2 2023 MASON . • Jew • . . **Note: Septic Tanks must meet s.mnbards required by WAC chapter 246-272C 1 and manufact-urer must be on the Dept of Health list of regstered sewage tanks.** fl of "*. . MAd CivieLL Septic .`)eoicy INSTALLATION & AThiIIiNA CE i .�,' 5,G6349 •`!! /4-k PAULA JOY JOHNSON l Pressure Distributor, Systems L!C J5 � . Grift" } 1. Install Laterals with contour of the ground. 2. Install trench bottoms level. 3. Tnstall locator tape or rebar at each end of all _I field laterals. . 4. Install observation ports as indicated on the plot plan_ One re; ed at distal end of each lateral in drairfield with bottom extending to the 'dr inrock! ve soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from around. Install` removable cap on top of port at final: ;rode level. 5. Install drainfield during dry weather aid soil cons-itions; any soil smearing must be eliminated by hard raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. 8. Install 1/8"mesh non-corrosive pump screen (min. 12 sq. ft. surface area, not to interfere with controls or floats.) Or primp screen may be substituted with Bio-Tube in septic tank. Pull bio-tube every 6-12 months and flush back into tank. - 9. Install anti-siphon valve above pump in pulp chamber to prevent the pump chamber from siphoning into the drain eid. 10. Ins`,%?i check valve in pump outlet line to prevent system from draining back into the pump chamber. 11. Tee to Tee cons-a-tic-don.between laterals and manifold with orifices oriented at 6 o'clock.. Tr stall laterals to the manifold fold with the orifices at 12 o'clock. (do not glue), after pressure test and Environmental Health Dept. approval, um orifices down (6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the '2 o'clock_position in lieu of turning the orifices down to the 6 o'clock posi`_on. 12.?ilter fabric required over drain rock prior to back tilling. the drair, rock extends above natural grade,ran the filter fabric at least 2 inches down the trench wall. 13. Encase all water uses within 10' of drain-field.and under any driveway/parking areas. 14. Divert all storm water runoff away from on-site sewage system. 15.No c'LLY in Chains allowed within '_O' of th up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 16. Have the septic tank and pump camber pumped or spected every 3 to 5 years. 17.No vehicular trams c over dra i nT;eld area 18. Inspect floats, clean filters, and test high water lever alarm every 6-12 months as needed. 19. All materials and workmanship must meet County and State regulations. 20. Deviation from`his design without prior approval from the Designer and Mason County Environmental Health Depa- rent will^rake this desion null and void. 21. All manhole Lids and access, sa--piing or inspection ports must have looking covers and be located at ground level. 22. All pressure systems with a pu p clamber outlet higher than the drain-field must have a 1/8"hole drilled in the discharge pipe above the p.=ap to prevent siphoning. 23.All transport lines under driveways or parking areas must be encased to prevent crushing. 24. Homeowner is responsible for a+l propeny lines. p p R o v SEP 12 2023 E .3„ 'l'l4SoN COUNTY ENVIRON44ENT4l HEA'T- JBW