HomeMy WebLinkAboutbld2004-00492 - BLD Plot / Site PlansGeneral Notes These notes are general in nature and do not set out all code requirements. It is the responsibility of the Builder to be familiar with the requirements of the codes. 2. All construction to conform to the Uniform Building Code (UBC), local codes, state codes, the Washington State Energy Code, and the Washington State Ventilation Code. 3. All footings to bear on firm, undisturbed soil, capable of supporting 1,500 psf permanently. 4. All footings to be minimum 12" below finish grade for single story areas and 18" below finish grade for two story areas. 6. Provide anchor bolts with 2" x 2" x 3/16" bearing plate washers at 4' 0" on center. No less than 2 per each section of mud sill and within 12" of each mud sill end. Conform to the Uniform Building Code. 7. Unless otherwise noted, the following grades of framing lumber shall be used: - 4 x beams shall be No. 2 grade Douglas fir -larch - 6 x beams shall be No. 1 grade Douglas fir -larch - Glu-lam beams shall be combination 20f, V4 grade (20f, V8 grade if cantilevered) Floor and roof joist and rafters shall be No. 2 grade hem -fir or Douglas fir -larch - Studs in shear walls and studs connected to holdowns shall be No. 2 Douglas fir -larch Studs shall be stud grade or No. 2 hem -fir or Douglas fir -larch 8. Unless otherwise shown, headers over exterior openings and over openings in interior bearing walls shall be 4x8 No. 2 Douglas fir -larch. All metal connectors shown on the drawings shall be Simpson Strong -tie Connectors, unless otherwise noted. 10. Design Loads: Roof Live Load: 55 psf (snow) Roof Dead Load: 15 psf (20 psf if roof tile) Floor Live Load: 40 psf Floor Dead Load: 12 psf Floor Partition Load: 10 psf Deck Total Load: 92 psf 12. Deck posts, beams, joists and decking shall be pressure treated, all purpose outdoor wood or of naturally rot resistant species. 13. All plywood and oriented strand board (OSB) and application to be it accordance with American Plywood Association standards and the Uniform Building Code. 14. Install solid, full depth blocking at all bearing points at joists and rafters. 15. Provide solid fireblocking around tubs and showers. 16. Unless shown otherwise, provide a 30"x18" crawlspace access. Location as determined by site conditions. 17. Provide 22"x30" attic access (if applicable) in location indicated or as required by code. 18. Guardrail height shall be 3'-0" high. Handrail height shall be 3' 0". Handrail required on all stairs with four risers or more. Guardrails required on all landings and decks more than 30" above grade. Picket spacing on guardrails to be maximum 4" clear. 19 Stair riser height shall be maximum 8'. Treads shall be minimum 9". Stairway width shall be minimum 36". 20. Chimneys, woodstoves, and fireplaces, and their installation, shall conform to the Uniform Building Code. Provide seismic bracing for chimneys per code. Owner shall provide Contractor with chimney and woodstove specifications and setbacks. 21. All windows shall be horizontal sliders unless otherwise shown. 22 Each bedroom shall have one egress window or door conforming to the Uniform Building Code. 23. All windows within a 24" radius of a door, or closer than 18" to the floor, must be safety glass. 24. Provide sheet metal flashing as required for a water tight job. 25. Plumb water heater P&T valve to exterior. 26. Install 110 volt smoke detector with battery backup in each sleeping room, each corridor giving access to sleeping rooms, and one on each level not containing sleeping rooms. Interconnect all smoke detectors. 27. .All electrical work shall conform to the National Electrical Code, State of Washington Electrical Code and local codes. 28. Plumbing and mechanical work (heating) shall conform to national, state, and local codes. 29. All hose bibbs shall have an approved vacuum breaker. 30. Install a 6 mil polyethylene vapor barrier on the top of the ground in the crawlspace. 32. Caulk, weatherstrip, or gasket around all windows, exterior doors, utility penetrations, etc. to limit air infiltration per Washington State Energy Code. 34. Install insulation deflectors in attic at soffit vents to assure proper ventilation. 36. Heat pumps and furnaces, and their installation, shall conform to the Mechanical Code and the Energy Code. 38. Owner or Contractor shall supply manufacturer, model number and sizes of heaters or furnace to Building Department. . 39. Owner or Contractor shall supply bathroom, utility, and kitchen fan manufacturer and model number to the Building Department. 40. Whole house ventilation fan shall be controlled by a timer switch or dehumidifier control with a manual o verride switch. 41. All exhaust ducts shall conform to the Energy Code for diameter, length of run and number of elbows. Insulate to a minimum of R-4. 42. Provide tested outdoor air inlets of minimum of 4 square inch in each living area, sleeping area, cooking area and eating area. Inlets may be integrated with window frames or through -the -wall vents. Indicated o n plan as The Architect is not responsible for site conditions. This includes soil bearing capacities, slopes, surface o r subsurface water conditions or any other surface or subsurface conditions. Buildings are designed with as assumed soil bearing capacity of 1,500 psf. Notify Architect of any site deficiencies encountered. NEW DRIVEWAY 9,8' SIDE YAW SETBACK (10% OF LOT WIDTH) RE -SLOPE BANK TO NO MORE THAN 2 TO I SLOPE OR PROVIDE A RETAINING WALL AS REQUIRED. MODIFY SLOPE THIS AREA FOR NEW DRIVEWAY APPROX_ LOCATION OF EXISTING DRAINFIELD EXISTING ACCESS ROAD TOE OF SLOPE 25' FRONT YARD SETBACK LINE 92 SIDE Y,4RD SETBACK (10% OF LOT UJIDT4-4) i TOP OF SLOPE DETERMINE EXACT LOCATION C/;IF EXIS?, SEPTIC TANK(5) AND DRAINFIEtLD AT PROJECT SITE EXISTING POWER AND WATER HOUSE LOCATION IS APPROXIMATE. DETERMINE ACTUAL LOCATION AT JOSSITE AFTER DETERMINING LOCATION OF SEPTIC TANKCS) AND DRAINFIELD_ 20' REAR YARD SETBACK LINE Legal: Div. 19, Lot 32 Lake Cushman Parcel No.: 422-05-52-0032 Address: APPROVED MASON COUNTY DCD PLANNING SITE PLAN REQUIRED TO BE ON SITE CHANGES SUBJECT TO APPROVAL By y)�� j 0LI Date SW 0 ‘40- C N EC 0 0 GF. c ct L NI 0 - - z- 0 -z 1,411 1 00 1 cn a) 0 0 Q1 • co • • • . • • al • ■ • ots w 0 LL • . • • • • i i • • a • • • • 1 • • gess U m U E 0 0 U 0 w CN tt- LO N) L.l J 0 W CN 4 00 LC) CO re 0 N 0 X 0 0 Sheet Contents E z V • Q) 0 z Q.) ao c 0- Q) V / 2oo400' 0 Sheet Number • Lc ces "E? ez 0 r a) r 0 cn 0 c 0 cn a) 0 Cr 0 0 cn s 0 cn 4) 0 Reproduction