Loading...
HomeMy WebLinkAboutState Patrol Building Remodels - COM Plot / Site Plans - 5/20/2015450 W. Business Park Road =CL- Business Park Road New septic tank if required Existing to be . remove'. -typ. ?Existing fire hydrant O r .:isting 'water meter Existing septic tank Potential new drainfield and reserve area if required / Existing storm water system Exit only \ J 9 a a 0 I7 0 tinl1'1g /l /i/I 11111I0�ii1iti �la CifI 11Ileii!l\hlii Ilid iI/1I Dis atc 1j sjE\:l space renovated to meet R'sk CategIV is ij'ory) 240 W. Henry Trusler Way Henry Trusler Way New concrete accessible parking space 2,561 sf - -- - Existing space renovated — _- - ------Training Area - \ - -- 1,379 sf --- Existing space renovated Landscape \ \ areas / Exit / optional staff entry 'ort of Shelton Building #92 (existing) 410 W. Business Park Ro. Existing concrete barriers to ren.,;in typ. i 7 0 ew parkiyfg spac.3s,('16) Existing tree area to remain Existing crushed rock driveway to remain Site Plan Sca Is: 1" = 20'-0" NORTH T Foster. Williams Architects 601 W. Railroad Ave. P.O. Box 102 Shelton, WA 98584 Ph: (360)426-0511 FAX: (360)426-2926 e-mail: mail@fosterwilliams.com Project Number 2014040 Project Title Mason County Dispatch Revisions Sheet Contents Site plan Date 5-20-15 Drawn By LAW Checked By Sheet Number 1 Of 4 Reproduction or re -use of these drawings without written per- mission of the Architect is prohibited. NOTE: NEW STAFF PARKING AREA TO BE PROVIDED IN THIS AREA EXISTING EXTERIOR WALLS TYP. - TO BE FILLED WITH NEW INSULATION E 0 r7 0 N N 10 0 REMOVE EXISTING BAY DOORS AND INFILL WITH FRAMING NEW UPPER WINDOWS IN EXISTING OPENINGS'- INFILL LOWER OPENING 39'-6" X 34'-0" APPROX. 15'-0" CEILING HEIGHT EXISTING Staff Entry L_ EXISTING WALLS TO REMAIN TYP. Director Office 14'-10" X 14'-7". NEW WINDOWS IN EXISTING OPENINGS TYP. REPLACE EXISTING DOOR WITH NEW WINDOW EXISTING COLUMNS EXISTING BEAMS ABOVE MECHANICAL SPACE ABOVE NEW CLERESTORY WINDOWS ABOVE IN EXISTING OPENINGS NEW STAIR UP TO MECH. Workroom 10'-3" X 9'-0" Office 10'-7" X 14'-7" NEW CONCRETE ENTRY SLABS TYP. 3 LOCATIONS NEW DOORS TYP. ALL LOCATIONS Office 9'-11" X 14'-7" IT Office 21'-7" X 9'-2" NEW WALLS TYP. Staff 13'-2" X 13'-4" Storage 13'-2" X 14'-9" Officer in Charge 12'-4" X 14'-5" D.F. INFILL EXISTING OPENINGS WHERE SHOWN EXISTING TO BE REMOVED TYP. Storage L NOTE: NEW VISITOR PARKING TO BE PROVIDED THIS AREA NEW ADDITION Kitchen SHOWER SHOWER Server 15'-0" X 14'-9" EXISTING ELECTRICAL PANELS TYP. Dispatch 33'-0" X 28'-10" ROOF OVERHANG TYP. NEW ADDITION TO BUILDING - 1,155 SQ. FT. NOTE: POTENTIAL CONFLICT WITH EXISTING GUY WIRES IN THIS AREA • Generator 11'-6" X 15'-0" EXISTING HVAC UNIT TO BE REPLACED NOTE: NEW ROOFING REQUIRED FOR EXISTING ROOF AREAS - NEW INSULATION ABOVE EXISTING ROOF DECK AND BELOW NEW ROOFING IS ASSUMED TYP. NEW HIGH WINDOWS Proposed Floor Plan Sca le:.I/4" = 11-0" 1 rq rq PLAN NORTH TRUE NORTH NEW ADDITION Foster Williams Architects 601 W. Railroad Ave. P.O. Box 102 Shelton, WA 98584 Ph: (360)426-0511 FAX: (360)426-2926 e-mail: mail@fosterwilliams.com Project Number 2014040 Project Title Tenant space development Mason County Dispatch Revisions Sheet Contents Floor plan Date 5-2o-15 Drawn By LAW Checked By Sheet Number 2 Of 4 Reproduction or re -use of these drawings without written per- mission of the Architect is prohibited. 10 0 N N 10 0 GENERATOR NEW ADDITION • / : NEW HIGH WINDOWS i ii ii ' ii ii it 16'-0". GENERATOR NEW SIDING THIS WALL 35'-0" NEW ADDITION North Elevation 5ca le:. I% = 1'-sue West Elevation Scale: 1/4" = 1'-0" Foster . Williams Architects • 601 W. Railroad Ave. P.O. Box 102 Shelton, WA 98584 Ph: (360)426-0511. FAX: (360)426-2926 e-mail: mail@fosterwilliams.com Project Number 2014040 Project Title Tenant space development O ci) 0 0 a. Mason County Dispatch Revisions Sheet Contents Exterior elevations Date 5-20-15 Drawn By LAW Checked By Sheet Number 3 Of 4 Reproduction or re -use of these drawings without written per- mission of the Architect is prohibited. r South Elevation Scale: I/4" = 1'-0" East Elevation Sca le: 1/4" = 1'-0" E a to 0 N N 0 NEW ADDITION BEYOND Foster Williams Architects 601 W. Railroad Ave. P.O. Box 102 Shelton, WA 98584 Ph: (360)426-0511 FAX: (360)426-2926 e-mail: mail@fosterwilliams.com Project Number 2014040 Project Title Tenant space development Mason County Dispatch Revisions Sheet Contents Exterior elevations Date 5-20-e Drawn By LAUD Checked By Sheet Number 4 Of 4 Reproduction or re -use of these drawings without written per- mission of the Architect is prohibited.