Loading...
HomeMy WebLinkAboutSWG2023-00293 - SWG Application / Design - 7/10/2023 MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 F Public Health & Human Services ELMA:360 482-5269,EXT 400 ;.. FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00293 APPLICANT Matthew Vanhorn Phone: Address: 22804 45th Place W TAHUYA, WA 98588 OWNER Matthew Vanhorn Phone: Address: 22804 45th Place W TAHUYA, WA 98588 SEPTIC DESIGNER Bob Paysse - Pioneer Digging Inc Phone: 360-426-1803 Address: 3083 E Mason Benson Road GRAPEVIEW, WA 98546 Site Address: 400 NE Dewatto Hills Rd Primary Parcel Number: 223187500060 Permit Description: 4-bedroom pressure system with sand lined trench Permit Submitted Date: 07/10/2023 Permit Issued Date: 08/03/2023 Issued By: David Anderson Current Permit Fees Paid: $525.00 (additional fees may be required upon installation of system). Permit Expiration Date: 08/03/2026 (based on date of inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY '1: .„I "' - DATE RECENED: MASON COUNTY 'I t o �3 N COMMUNITY SERVICES AMOI ECE{�LD RECENEDBY: W M Public Health;Community Health/Environmental Health) /� G 360-477 9G70,err 400 a 360,275 M67.ext.600 cn S W G x ` / t O/.� 21, g O 6I$�1.6th Street-Shelton,WA 98584 J\/V�[�/! U TT O N Z05 . T T) ON-SITE SEWAGE SYSTEM APPLICATION 3 Xi i ,1'1 APPLICANT PHONE m r MATTHEW VANHORN Z ' c MAILING ADDRESS-STREET,CITY,STATE,ZIP CODE 22804 - 45TH PLACE W MOUNTLAKE TERRACE WA 98043 CO a X SIT c.-_:.cSS-STREET.CITY,ZIP CODE 400 NE DEWATTO HILLS ROAD TAHUYA WA -___.985.888_ _ I N 4 NAME OF DESIGNER PHONE i ;i La (� 0 11 LJ1 LL77 I N ?1 ROBERT H. PAYSSE 360-426-1803 ul' 1 NAME OF INSTALLER PHONE _I. JUL to 2023 I W TBD u `3 . PERMIT TYPE(select one) DRINKING WATER SOURCE ,J V� 1 __ L, Pr RESIDENTIAL OSS F CO r W COMMUNITY OSS N I COMMERCIAL OSS M PRIVATE INDIVIDUAL ELL 5-PR VATE TWO-PARTY WELL --- -----Z4 I CO TYPE OF MURK(select one) Q PUBLIC WATER SYSTEM I IF NEW CONSTRUCTION/UPGRADES ff.REPAIR I REPLACEMENT OTHER DETAILS(select all that apply) 0 TABLE IX REPAIR I i SUBMITTALSMI El SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE co 1 LCl-DESIGN FOI-A(REQUIRED) MI q SEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE r- I 0-1 �":..,ivER(S)(IF APPLICABLE) 4 5.56 0 I ' O DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) OUT NORTH SHORE AND UP BELFAIR TAHUYA ROAD. RIGHT ON HAVEN WAY. I O RIGHT ON MOUNTAIN VIEW DR. RIGHT ON TAHUYA BLACKSMITH RD. FOLLOW TO l- LEFT ON DEWATTO HILLS RD. GO 0.4 MILES TO PDI SIGN. WALK INTO DRAINFIELD ° o SITE. FOLLOWING GREEN RIBBONS. SEE SITE PLAN. _. �co SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I I:_ OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE(tor reporting purposes) 0 VOLUNTARY ❑MAINTENANCE/PUMPING 0 BUILDING PERMIT ['HOME SALE ['COMPLAINT 0 OTHER: '^'c=':..:art SOIL LOGS COMMENTS/CONDITIONS MCc-s0`' f'&t.►v -�51'70 crypte, r Po res rt fan Tie- 0-57t i eci f 5 mt f5-VG 70°4 C1,wll Ivy ref 21�w1 1 ; ,. 7 ff3.- C- 5`(4 CC1Lx ,, RECORD DRAWING AND INSTALLATION REPORT SOIL CODES: i 1L=VERY_.fi=GReVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL. ,,,or't SIGNATURE DATE APPLICATI EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE I 7/?$/70 5/3/Z(176' 0'2 V3/7oZ) THIS ORM NFAY BE SCANNED AND AVAILABL FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 12/7/2015 r. i DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 3 1 8 — 7 5 — 0 0 0 6 0 • A design will be reviewed when 3 copies of each of the following are submitted: ''Completed design form that has been signed and dated. Scaled layout sketch,including all applicable items on checklist Scaled plot plan,including all applicable items on checklist. ''Cross-section sketch,including all applicable items on checklist. '" this form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X 17" \^ PARCEL IDENTIFICATION Permit Number: SWG o[�C�o<J- yXoc..� Designer's Name: ROBERT H. PAYSSE MATTHEW VANHORN Designer's Phone Number: 360-426-1803 Applicant's Name: Mailing Address: 22804-45TH PLACE W Designer's Address: 3083 E MASON BENSON RD ____....... ..,. MOUNTLAKE TEI WA 98043 GRAPEVIEW WA °5 City State Zip City State Zip DESIGN.PARAMETERS Treatment Device 0 Glendon Biofilter 0 Sand Filter 0 Mound iFiSand Lined Drainfield 0 Recirculating Filter,Type: 0Aerobjc;Unit- Make/Model 0 Disinfection Unit Make/Model Other: Drainfield Type , ❑Gravity (1'Pressure lifTrench 0 Bed 0 Sub Surface Drip iSeptic Tank/Drainfield Specifications Laterals Number of Bedrooms 4 Schedule/Class SCH.40 Daily Flow:Operating Capacity 360 g d Length 40 f> / Daily Flow:Design Flow 480 /d Diameter 1.25 inj/ Septic Tank Capacity(working) 1500 gal Number 4 Receiving Soil Type(1-6) 1 Separation 10 ft V Receiving Soil Appl. Rate 1.0 gp/ 2 Orifices Re45rOd`Pr ary Area 480 ft24/ Total Number of Orifices 40 Designed Primary Area 480 ft2 7 Diameter 3/16 in Designed Reserve Area 480 ft2 Spacing 48 in Trench/Bed Width 3 ft / ' Manifold Trench/Bed Length 160 ft ✓ Schedule/Class SCH.40 Elevation Measurements Length 30 Original Drainfield Area Slope 6 % Diameter 1.25 in New Slope,If Altered 6 % Preferred manifold configuration used? l 'Yes 0 No i Depth of Excavation Up-slope 14+24=38 inV Transport Pipe from Original Grade Down-slope 12- in — Schedule/Class SCH.40 t5esigti � ' rtical Separation in Length <50 ft Gravelless Chambers Required? 0 Yeses �0 Optional Diameter 2 in Pump Required? 66 Yes 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 8 Diff.in Elevation Between Pump&Uppermost Orifice 10 ft Dose quantity 60 h ad 2 ft Chamber Capacity(flood) 1500 adinneld Squirt Height/Selected Residual(head) a`' Uppermost Orifice l 'Higher 0 Lower than Pump Shutoff [ r le k those required. 23.6gpm f r' tI� [Ela se Meter l 'Event Coun er Capacity @ Total Pressure Head P Calculated Total Pressure Head 18.7 ft If Timer: Pump on 2 MIN ,Pump off 4 HRS Comments AUG 0 3 20Li MASON COUNTY ENVIRONMENTAL HEALTH I DJA DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 3 1 8 -- 7 5 -- 0 0 0 6 0 • Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch . •0 ' Test hole locations Ig Drainfield orientation and layout Reference depth from original grade: 2i Soil logs g Trench/bed dimensions and liti Septic tank g Property lines critical distances within layout 91 Drainfield cover IZI Existingand proposed wells g D-Box/Valve box locations p p Reference depth from original grade within 100 ft of property g Septic tank/pump chamber and restrictive strata: ' R( Measurements to cuts,banks,and locations N 9f Laterals,trench/bed,top and surface water and critical areas 66 Observation port location bottom g Location and orientation of 91 Clean-out location 0 Curtain drain collector curtain drain and all absorption RI Manifold placement 0 Sand augmentation components g Orifice placement Other cross-section detail: g Location and dimension of 66 Lateral placement with distance l Observation ports/clean-outs nnmary system and reserve area to edge of bed Other Information lZi Buildings 6 Audible/visual alarm referenced Yes No • Direction of slope indicator g Scale of drawing shown on scale g 0 Design staked out g Waterlines bar 0 M'Recorded Notices attached 6Q Roads,easements,driveways, ❑ (1 Waiver(s)attached 1 ,_ parking l' 0 Pump curve attached g North arrow and scale drawing 0 g Evaluation of failure shown on scale bar Non-residential justification o 16 Waste strength ❑ l Flow DESIGN APPROVAL The undersigned designer must be notified by installer at time of installation 66 Yes 0 No C °1/6-41/4)k' 7(r0 C' Signature of Designerr� Date p The undersigned has reviewed this design on behalf of Mason County Public Health and determined fit,CIVEDi Compliance with state and local o regulations: AUG 0 3 2023 / 6-73/?az MASON `nvironmental Health Specialist Date ���N 1'ENVIRoNMENTq DJq L HEALTH CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: - ►®design is stamped"Approved"by Mason County Public Health. (0/?Of�� v The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, • unless prior authorization is obtained from Mason County Publiatcalth. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/7/2015 I I I I // / / / / ', ,� / / / / ,5\ ,,\ / / / / -_,. / 1 / �- / I -\ EASEMENT I I APPROX. POND I I 1- I KEEP WATERLINES 1O+ FROM TI I SEPTIC COMPONENTS & LINES 0I/�--`\ 11�� \ I PROPOSEDmai \1 DRIVEWAY & ACCESS —� I� TO DRAINFIELD SITE _/1PRIMARY PROPOSED I & RESERVE HOME , LOCATION I 1 AP a. AREA I 0VEn i M AUG 0320?3 // \ AS�NCOUN�ENVIRQ ENt 1/�RHO `I1 NM DJA Ai HEALTH o' II POSSIBLE WELL SITE • J (MAINTAIN REQUIRED SETBACKS) \\\ II\ J/ �4 \\ \\ // / I ¢ �� \` ,(F --,.. i r \\'9 AN- jTN / / , ""80.;v:, \ O� •,/ v ,- J • ►Y: :449s, I S \\�V Q — ———— 16 y. FCBE[1T ll MYSSEt', \ EXPIRES AN ASBUILT/INSTALL SIGNOFF FEE WILL BE CHARGED AT TIME OF INSTALLATION CUSTOMERS MATTHEw vANHORN TEST HOLE I: TEST I IOLE 2 TEST HOLE 2: PIONEER DIGGING INC. PARCEL# 223t8 7s-00060 0-50 VG\tS VG\1S 0-52 vc;\ts f ROOIS@50 ROOTS @60 ROOTS @52 SEPTIC DESIGNS ADDRESS: 400 DEWATTO HILLS RD 3083 E MASON BENSON RD. GRAPEV1EW,WA 98546 DESIGNER ROBERT FL PAYSSE ED DISCLAIMER.THIS IELO SURVEY.EMENTS NIOCES INCLUDE OUNTY GIS DESIGN MENDED FOUNTY R OFFICE 360 42&I803 FAX 36o-427 2353 SHEET: SITE PLAN SCALE l"=l00' DEPARTMFNT/AGE CY REVIEW DESIGNER NOT R PURPOSES ONLY PROPOSED OE oNs BILE FOR SETBACKS U RfuTTETDNTO SEPTIC COMPONENTS. i ► AN ASBUILTI INSTALL SIGNOFF FEE WILL O O BE CHARGED AT TIME OF INSTALLATION SEPTIC TAN K •I PUMP TANK I OB ✓ - --- •• O .. PORT � ; . ,,(77JJJ��� & C/O A .4.,,,,, • MANIFOLD L1_ J/� j/: XES//215ei/E// ////Z I ' 4O' PRIMARY • /�Ji' ry / � �JJ1�_��� A 4"3034 I • 40' PRIMARY • • I il • ://14.77 1-2 1.25"S . 40 4fXr2,5 Wrz, A P� I o O VED 2' Attie 6`` +�( 4, m AUG 3 2023 OB PORT Da CYO - � :LEANOUT � r1'E�rVLROpt7rfF�'TA(F{t; FINISHED DJA EACTI, 6"+ COVER GRADE THREADED CAP ■ FILTE; I I I . FABRIC 16" ORIFICES �T ORIGINAL ..•�._..:.:._.�.. Y, I•!.:I_I:•;I=l_ 0 12:00 W/ ,,;..._.,._. . F: .:•:• •:P=• GRADE SHIELDS ...,. . . .;._ ,'. • • .-. . ._ .2. . . .;. ..., • •....:.:-:.:::!-::::‘,:t\tx,-51.4Ev..-.---:- ..'%:...-'7.-::.i . • •.• 90° SWEEP �' ••' .: :n o€ .. . ,.T..I •-•-•�•-•-•-•-•-•-•=•I •,•,.'a: • L= GLUED TEE V•. I•:. :c,►'- ADJUST TO t, `-,: , ;, # OF LATS 12.E• ���{.21=...+ � • �•� ' �'�'� y,= - - I ASTM C-33 cV SAND *If • i' • I t'.'. RORE[SiTrH"MYS$E ,`' RISER/LID EXPIRES TO FIN. GRADE PIONEER DIGGING, NC CUSTOMER: MATTHEW RCEL#.773 8 HORN TEST HOLE I: TEST HOLE 2 TEST HOLE 2: PA70.50 vc s 0-60 VGMS 0-52 VGmS ROOTS @ 50 ROOTS @ 60 ROOTS @ 52 SEPTIC DESIGNS ADDRESS: 400 DEWATTO HILLS RD 3083 E MASON BENSON R.D. GRMEVIEW,WA 98546 DESIGNER ROBFRT H.PAYSSE �ORRSSURMElt VEYS IES IS�iDMEASUREMENTS�COUNTTYGIS DESUDE I GN INNTE�NDEFOR RSEPTITICC OFFICE-360-426-I803 FAX-360-427-2353 SHEET: DF DETAIL SCALE I°=l0' DEPARTMENTJAGLENCY REVIEW DESIGNERRNNOT RESPONSIBLE FOR SETBACKS UNRESATEO o SEPTIC COMPONENTS Sand Lined Trench Systems-Recommended Standards and Guidance Effective Date:March 2014 Introduction Sand lined trenches provide biodegradation or decomposition of wastewater constituents by bringing the wastewater into close contact with a well developed aerobic biological community attached to the surfaces of the filter media. This process requires unsaturated downward flow of the effluent through the filter media. The media may be coarse mineral sand or equivalently sized crushed glass meeting one of the media specifications listed in Appendix A. As a departure from the intermittent sand filter,the media is not contained in a watertight vessel. Instead,the media is placed in trenches or beds in the native soil. Proper function requires that influent to the sand filter be distributed over the media in controlled,uniform doses. In order to achieve accurate dosing,these systems require timed dosing with associated pump chambers, electrical components, and distribution network,with a minimum of 4 to 18 doses per day(depending on sand media used) spread evenly over a 24 hour period. The effluent is absorbed into the native soil at the bottom of the sand lined trenches,which accomplishes dispersal into the subsoil environment and some further treatment. A sand lined trench is a combined treatment component and soil dispersal component. Possible Applications: A sand lined drainfield trench(sand filter)may be selected for a site with excessively permeable (Type 1) soils. The addition of 24 inches of filter media(coarse sand)to a pressure distribution soil dispersal component provides the wastewater treatment not provided by the Type 1 soil. Treated wastewater is discharged directly to the receiving soil for dispersal into the subsoil environment. See Figure 2.1. If the soil adjacent to the layer of drainrock atop the sand media is Type 1, additional filter media sand or an impervious material must be placed between the type 1 soil and the drainrock making up the trench's sidewalls and end walls to prevent short-circuiting. When sand is used for protection against short-circuiting, a minimum of six(6) inch width of filter media sand is required. The sand bed under the drainrock will also be widened by six(6) inches on each side. See Figures 2.2 and 2.3. When an impervious material is used,it must be 30 mil PVC and must extend from above the gravel bed to six(6) inches below the gravel/sand interface. See Figure 2.4. A sand lined drainfield trench(sand filter)may also be selected for a site that has its more suitable soils for dispersal(and further treatment) at a depth greater than three feet. Filter media(course sand) is placed below the drain rock to provide adequate levels of treatment so deeper soils more suitable for dispersal into the subsoil environment can be"reached." See Figure 3. A bottomless sand filter is a special case of sand lined drainfield trench in which a 30 mil PVC lined enclosure is designed and installed for con aining the distribution system and/or filter bed above grade. It is quite similar operationally to an intermittent sand filter,but is not lined on the bottom. A bottomless sand filter is selected typically to utilize more suitable soils high in the soil profile for dispersal and treatment. The enclosure for the filter bed must be designed by a professional engineer if the containment walls are over four feet in height measured from the bottom of the footing to the top of the walls. See Figure 4. APPROVED AUG 0 3 2023 MASON COUNTY ENVIRONMENTAL HEALTH DJA DOH 337-013 Page 7 of 31 Sand Lined Trench Systems-Recommended Standards and Guidance Effective Date:March 2014 Figure 2.2 -Type 1 Soil Extending up into Trench/Bed Zone (Option 1) (Extends Above Bottom of Gravel/Gravelless Trench/Bed) Approved geotextile ,,, A """=% =""" " ' 6"-12" loamy soil backlit! ::. .:. :::. 777/7/// •>'• • • ;514�- ' : : . / 9"• 12"gravel wipipe or • Y -� _ •. -v • :•: :: approved gravelless :: . . . 0:] •:•: product • : >24"approved sand media ::: (or gushed glass) AdlaE cc .. �. 12" -18"to restrictive layer or water table,depending on �' ' ' .t0 / required treatment level 4 Figure 2.3 -Type 1 Soil Extending up into Trench/Bed Zone (Option 2) (Extends Above Bottom of Gravel/Gravelless Trench/Bed) Approved geotextile j • 1C 6"-12" loamy soil backfill �,�� ' 9"-12"gravel vi/pipe or �,-'�•-�-. :.^��;� approved gravelless product y^_ram: �. ;. . . .:IIII MMINIBUNIII g >24"approved s an d meth a • it y 1 (ar crus hed grass) to depth at least 6"into soil used for siting trench/bed for TLB 1 10'or less tv1m.12"•16 to restrictive layer o r water table,depending on required treatment le\el r;/' APPROVED AUG 0 3 2023 MASON COUNTY ENVIRONMENTAL HEALTH DJA DOH 337-013 Page 9 of 31 24"RIBBED RISERS W/BOLT ON WATER-TIGHT LIDS ' CLEANOUT USE RISER LID ADAPTERS WITH NO GASKET LIDS i I FINISHED GRADE • a ...: I•, — Q- _ WATER.-TIGHT ?- ; . ._ JOINTS F , • , S� INLET '~� �1�r `--i . Z; 7 / l A OUTLET TWO WAY TEE i' • M`" i. •• 4„OSI WATER-TIGHT =; s. EFFLUENT JOINTS — FILTER TANKS MUST BE h' ,. `- ON STATE DOH 1500 CALLON WATER77GHT { APPROVED LIST ` CONCRt/tSEP77CTANK .nId�.2i'C� aa. «44- OF SEWAGE - TANKS ' �` PUMP TANKS .,i, "` OVER 1000 GAL. . ' ,�r + • REQUIRES TWO ,,. _;:I� 4`.Q84i�eov` A4w. Y{- ACCESS RISERS . . .,�.. ,: `''tom ,•:,szi,5 :>e;-; .,f'. ' ? i • -. .—•' TO GRADE •.' ',n;'''. _ P„v;v1P TANKS ���• ''tN`j LOCATED AT HIGHER AQUAWORKS tt ,..sy .•P v$ CONTROL PANEL ELEVATION THAN vv/TIMER,EVENT COUNTER r ELECTRICAL WORKDONE 24"RIBBED RISERS DRAINFIELDMVST &HOUR METER o BY EtaNSEDELECTRICIAN W/WATER TIGHT LIDS HAVE ANTI-SIPHON DEVICE INSTALLED. } FINISHED GRADE ELECTRICAL CONDUIT 1.1 _M I TRANSPORT LINE • INLET SUNION 8z BALL VALVE 1500 GALLON WA7ER77GHT A A CONCRE7EP1/MP TANK �••7 ji , (28.5 GAL./IN.) IX 0 V r , WATER�O NTS �� ",° AUG 31023 • PRESSURE TRANSDUCER • (OR FLOATS) N I Iv �OU �Aty � 'J5ETANKS FITTED • I DJq NTgC HE.Atr,' W/CAST IN WATER / ' TIGHT FITTINGS FOR USE RUBBER IN LET/OUTLES AND • PUMP BUCKET: _ GROMETS FOR CAST IN RISER - BUCKET HEIGHT MUST BE 1 TRANSPORT LINE ADAPTERS TO AT LEAST HEIGHT OF PUMP AND ELECTRICAL ENSURE WATER _ �'; ON RISERS. MAKE TIGHTNESS '" •• . •- . .` .; '.. •• , • ,. - . a SURE ALL HOLES ARE WATER-TIGHT PIONEER DIGGINLi 11 TC. CUSTOMER: MATTHEW VANHORN SCALE:NA N PARCEL#:22318-75-00060 INSTALL TANKS ON ORIGINAL OR SEPTIC DESIGNS ADDRESS:400 DEWATTO HUI S RID COMPACTED LEVEL SOILS. RUN CROSS ;nx:I,VASON BENSON R.D. GRAPEVIEW,WA 98546 DESIGNER: ROBERT H.PAYSSE CONNECTIONS INTO ORIGINAL SOILS TO OFFICE-360-426-I803 FAX-360-427-2353 SHEET: TANKS SCALE NA AVOID SETTLING. { 'Installation & System Notes 1. Installer must contact designer for final inspection of the installation prior to cover. All components, including tanks, lids, transport line, drainfield,and water lines must be open for inspection. A$350.00 fee will be charged for time involved with the inspection of the installation and creation of the record drawing. The designer reserves the right to charge additional fees if multiple visits are needed due to installation errors or inaccessible components. 2. This septic design must be installed by a certified installer with the local health department. All components shall be installed i according to state,county, and manufacturer requirements. For Homeowner Installs,the owner must get approval from the designer and local health department prior to attempting installation. 3. Designer is not a surveyor. Installer must familiarize themselves with property line locations prior to installation. Any confusion or conflicts with line locations should be reported to the property owner. A licensed surveyor may be necessary prior to installation to confirm all line locations. Any discrepancies found must be reported to the designer immediately. 4. Drainfield area may only be cleared by a licensed installer familiar with sensitive drainfield area preservation. The builder, lot developer, or property owner shall not clear the drainfield area. Any clearing required for drainfield installation shall not remove or disturb any top soil in Primary and Reserve areas. Removal or disturbance to drainfield soils could render design 5. The property owner and installer are responsible for locating all underground utilities(ex. water,gas, electric) prior to installation. Any utility locations shown within design drawings are likely approximate and may not be exact. 6. All proposed tanks must be installed on original soils or compacted gravels. Extend all tank connection lines out onto original soil to avoid settling issues. Risers and lids must be brought to finished grade and left accessible for future operations and rnainienance. Component manufacturers (ex. ATU,Glendons,) may have other requirements not listed within this design. 7.All electrical wiring shall be done by a licensed electrician or homeowner(if allowed) and must be permitted through Labor and Industries. 8.The proposed septic system should be installed in dry weather conditions. Any failed attempts at installation during wet weather conditions may render this design void. l'iviaintain loft to waterlines with all septic components. If less than 10ft is required, sleeving in sch.40 pvc is required. If sewage transport lines and waterlines must cross,waterline must be 18" above sewage line with one of the lines sleeved in sch. 40 pvc 10ft in each direction of crossing. 10.This design may include waiver applications with specific mitigation measures pertaining to installation,operation and maintenance of the proposed components. 11. Stormwater runoff,footing drains, roof drains must be diverted away from any septic system components. No curtain, foundation, perimeter drains shall be installed 30ft downslope and 10ft upslope of drainfield areas. 12. This design is site specific and intended to meet state and county requirements that are related to the system components being proposed. Any placement of proposed buildings, proposed wells or other non-related items on these drawings may or may not meet other requirements. ali 13'Hii onsite septic systems require regular maintenance to verify satisfactory operation. The t�� ner/operator is responsible for the continuous operation and maintenance of the system per WAC 246-272A. o bpq d aintenance information, refer to Mason County Public Health Homeowner's Manual,which should be received after ins 1. AUG14. System owner should be cautious of landscaping around septic components. Root in usion 0 3 can cause premature failure of the drainfield area. In addition, bushes and trees should be' SVQNNn Zu?3 away trom lids and other septic maintenance points. ENV/RvNmENrgj 1�4 NFAc rN 15. Changes made at time of installation may impact designer calculations, pump sizing, and 'q 4. compliance w/county and state requirements. Contact designer prior to install w/any •A `• proposed variations from design. Changes may result in additional fees and permitting. �If, ,.,4,,,;; CUSTOMER MATTHEW VANHORN 1.•. - • niC��rr -" DIGGING INC. SS .._•- .�- � • PARCEL#:2?318-75.00060 I�' ROBER�nM31iY1YSEE ;.`•'1 ' SEPTIC DESIGNS ADDRESS: 400 DEWATTO HILLS RD ,0... . ...} 3083 E MASON BENSON RD. CRAPEVIEW,WA 98540 DESIGNER: ROBERT H.PAYSSE EXPk:_s OFFICE-360-426 I803 FAX-360-427-2353 SHEET: NOTES SCALE NA I