HomeMy WebLinkAboutBLD2023-00289 Remodel Garage - BLD Plot / Site Plans - 3/13/2023RECEIVED
VICINITY MAP
1
I
c
i
i
PROJECT
SITE
PARCEL# 320222390024
PROPERTY
BOUNDARY
SECTION 22 TOWNSHIP 20N RANGE 3W
DAMES AND BARBARA ANDREWS-GARAGE ADDITION
ELECTRICAL
DROP
PARCEL#
320222390023
PROPERTY
BOUNDARY
1166.00
1251 E. LEEDS DR., SHELTON, WA 98584
PROJECT
AREA
EXISTING
SHED
PARCEL# 320222390022
1425.00
EXISTING RESIDENCE
±4353 S.F.
INCLUDING GARAGE
1435.00
SITE PLAN
1 "=20'-0"
MINI/SPLIT
1101.84
.40: MEM
SCALE: 1 "=20 FEET
0
5 10
20
i
0
TOPOGRAPHY NOTE:
SITE AND TOPOGRAPHIC INFORMATION
FROM PUBLIC INFORMATION AND
CITY/COUNTY RECORDS.
EXISTING UTILITIES NOTE:
EXISTING UTILITY INFORMATION WAS OBTAINED FROM BEST AVAILABLE SOURCES AT THE TIME OF
DESIGN. UTILITIES MAY EXIST ON SITE THAT ARE NOT DEPICTED. CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR RELOCATION OF CONFLICTING EXISTING UTILITIES WHETHER SHOWN OR NOT. CALL
FOR LOCATES 2 WORKING DAYS BEFORE BEGINNING CONSTRUCTION. WWW.CALLBEFOREYOUDIG.COM
EROSION CONTROL RESPONSIBILITES NOTE:
EROSION CONTROL MEASURES ARE NOT LIMITED TO THE ITEMS ON THESE PLANS. THE CONTRACTOR
IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL MEASURES.
NO SILTATION OF EXISTING OR PROPOSED DRAINAGE FACILITIES SHALL BE ALLOWED. CARE SHALL
BE TAKEN TO PREVENT MIGRATION OF SILTS TO OFF -SITE PROPERTIES.
SEPTIC
TANK
SEPTIC
LINE
1150.00
1121.00
WELL
ELEVATED
DECK
.40
ADDITIONAL
MINI/SPLIT
LOCATION
APPROX. HIGH
WATER MARK
PROPERTY
BOUNDARY
Quaoa- oo;B9
HAMMERSLEY
INLET
0
0
0
PROJECT INFORMATION
OWNER: JAMES AND BARBARA ANDREWS
8217 S. SHERIDAN AVE.
TACOMA, WA 98408-1918
PROJECT ADDRESS:
1251 EAST LEEDS DRIVE
SHELTON, WA 98584
PARCEL: 320222390023
ZONING: 18 RESIDENTIAL
ACRES: ± 1. 00
CONTRACTOR: ALLEN HOMES CONSTRUCTION
DRAFTING: NORTHWEST LINEWORX
SHEET INDEX
SITE PLAN
MAR 13 2023
615 W. Alder Street
NORTHWEST LINE
0
1360-951-7699 • www.northwestlineworx.com
I NO. DATE REVISION
SITE VISIT/MEASURE EXISTING
DRAFT PLAN
DRAFT PLAN ANNO./DIMS.
REVISE PER CLIENT
REVISE PER CLIENT
REVISE PER CLIENT
N
I
PO
n
0
07-20-22
N
I
N
N
n
0
N
I
DD
N
I
•—
01-20-23
N
I
0
N)
I
0
—J
CL
w
�--
c.n
Sheet Contents
F
V w
CC
�Z
ZU CC
cn Q
m
va-
c') Q
pp
w c:1
O
z
Q
_zw
LU
U
*
L
W
z
W
>
z
W
N
N
N
c-1
N
00
0o
rn
ob
0
00
or,
Q
2
0
Designed By
Drown By
WMG
Checked By
Dote
07-13-22
Project Number
22014
Sheet Number
C0.1
1 of 1
EXISTING
HVAC UNIT
NEW HVAC
UNIT
O
O
DAMES AND BARBARA ANDREWS-LOWER FLOOR REMODEL
1251 LEEDS DR., SHELTON, WA 98584
11'-102"
EQ
5'-0"
EQ
1 1 "
2868
5'-0"
8'—
GAME ROOM
90 CFM
CEILING FAN
N
•
EXTEND PANTRY
UNDER STAIRS
20'-0"
11'-6"
7'—
„
0
10
SMOKE/CO2
DETECTOR
6'-0"
3068
D" r'ROOM
12'-11"
SMOKE
DETECTOR
CLOS`
SD
11 '-9"
2
3068
4N CLOSET
i
•
2.
0
I
21'-6h"
/
LIVING ROOM
/
;
/ ; � / ; ,
2'-0"
5050
5'-0"
11
60610 SGD
5'-10"
4'-6"
10'-52"
3068
UP
4'-0"
0
f/0
00000
REF
3'-
11
I
OVERHEAD RANGE
VENT
KITCHEN
5'-3"
10'-52"
ISLAND
DINING/
FAMILY ROOM '
SMOKE
DETECTOR
2x4 WALL
FURRING, TYP.
3068
6'-42"
W/D
C
50 CFM •
VENT
90 CFM
CEILING
VENT
BATE!
2868
� V ru =
FLOOR DRAIN
BENCH
t\
12'-11"
0
•
0)
\o
3068
/
OFFICE
O
0
c0
0
/ i
•
„
90610 SGD
9,-0„
7'-4 "
90610 SGD
9'-0»
11
3'-
11
60610 SGD
6'-
„
15
22'-0"
33'-8"
13'—
„
ENERGY CREDITS
HEATING:
EFFICIENT BUILDING ENVELOPE:
AIR LEAKAGE CONTROL
HIGH EFFICIENCY HVAC:
EFFICIENT WATER HEATING:
OPTION 4
OPTION 1,3
OPTION 2.2
OPTION 3.4
OPTION 5.6
TOTAL CREDITS
_ .5
_ .5
= 1
= 1.5
= 2.5
= 6
69'—
„
LOWER FLOOR PLAN
1/4" = 1'-0"
N
=x
SCALE SET FOR 24"x36" PAPER. REDUCE SCALE FOR
NEW HVAC UNIT TO BE PLACED
BELOW DECK, ATOP CONCRETE
SHELF.
CONCRETE WALKWAY
BELOW DECK.
SHEET INDEX
A1.0
LOWER FLOOR PLAN
NORTHWEST L 1 N El
I360-951-7699 • www.northwestlineworx.com I
x
0
I NO. DATE REVISION
SITE VISIT/MEASURE EXISTING
DRAFT PLAN
DRAFT PLAN ANNO./DIMS.
REVISE PER CLIENT
REVISE PER CLIENT
REVISE PER CLIENT
07-13-22
NI
N
0
07-27-22
12-28-22
01-20-23
N
)
0
ir—
N
*
in
c0
Sheet Contents
LOWER FLOOR PLAN
z
O (I)
UM CC
CC CI
Z
z
Q
0 �
Q
Z m
Q °�
Q
w m
a
O z
Q
z w
*O
00
c,
ob
0
00
2
0
I —
Designed By
Drawn By
WMG
Checked By
Date
07-13-22
Project Number
22014
Sheet Number
A1.0
1 of 1
B
C
D
E
F
1
1-6'
- XO
O) Lt. co
;moo O <
O
O o
Is"0
0
W
- �XO
c;)u_m
L.00<=
oo0
1 '-6"
3'
3056 SH
3056 SH
3'-
DECK
19'-71/2'x21-71i2'
425 sq ft
17'
6'
6068 SGS
6010 ABOVE
Covered I Enclosed Deck
16 -5' x 16-8°
274 sq ft
6068 SGS
6010 ABOVE
17'
KITCHEN EXHAUST HOODS
All exhaust hoods with a capacity of more than 400 cfm sha!I be
provided with make-up air at an equivalent rate. The make-up air shall
be equipped with a means of closure and shall be automatically
controlled to start and operate simultaneously with the exhaust system.
See plan review checklist item #8 and Mason County policy attached.
5a/
DECK
14-81/4' x 32'-11 1 2'
693 sq ft
3'
3056 SH
DN
(o
2
1'-6'
O >
O 0
CD
co C <
co O
co
0
Cr) M
u> >
O 0
CO
CO
0 ,O
CO
co
w
c10 co
lA <
CO 0
CO 0
0 0
1
3' —
3050 SH
T Z _
14'-4`
6'-10`
C\i
ster Sarni
13 -11 1 '2` x 21 '-51 /2'
300 sq ft
Frame Stair Head Room into
lower _-;_
Dining Nook
10'-1 1 /4 x 17'-2"
171 soft
Vault Line
rl
room =-
14'0°x12-_-
179sc,
6040 SL
3' 5'
14.-6°
r�
Family
23-0' x 15-6'
356sq`t
14'-6 1/2 - -
3
6"
--61/2"
Master Ba:-
T-11 314' x 12 =
111so`.
O PEIi! BELOW__ -t7
,C -3 3'4' x
41 sqft
Kchen
- 12-91.2'
--k
� C9
m
Zo
Ze
2-8
BATH
2-4 1 '2" 2'-4"
L)N
12-
4'
2'
r-
1 01-10"
7'2'.2
4
0ff;ce
13--2 x 13'-11 1 =
167 sq ft
4'-11 1 I2" — ; -- 10' --
20
SL S.G.
11"
2'
2-
Floor Plan
Scale 1/4" = 11-0"
U
2 0 x 6'-5 1 /2'
2'-4 1 2"
0
6' 10
71_d"
'2Wall
16-2'PG-
448 sq t
21'-11 1.2
101-10"
_;0"
ae2-oor
14-10"
LIVING AREA
2871 sq ft
2"-
8'-0 1.2'
3050 FX S.G
c °ORCH
xE- _
3050 FX S.G.
6040 SL
3'
9-10'
4-6 1 /2'
-612'
SLAB
x 13'-4 3.8'
5'-1 1 4" -.
5
Optional Man Door
O
L0
m
N
Zo
10080
36' -
33'-11 1 i2"
Garage
39'-5 1 !2° x 27-0'
1029 sq ft
2c.1
Type X Sheetrock Required. See Note
°R302 - Dvrelling;Garage Separation"
10'
A
2'
42'-4"
Shaped 2x10 spacers
will be cut to ensure a
tight fit to water heater.
Bollard to P rotecl ---
Appliances from
Impact
6
18080
16'
Water Heater Strapping
1/3 Water
Heater
1/3
1/3
Platform Must be
Anchored to Wall
4'-6"
(0
Zo
7
THESE PLANS MUS'BE
ON THE JOB SITE
FOR INSPECTION
CARBON MONOXIDE ALARMS
Approved carbon monoxide alarms shall be installed in all new residential
construction. They shall be installed in the immediate vicinity outside of
each separate sleeping area in dwelling units, a minimum of 1 per floor.
Carbon monoxide alarms shall be listed as complying with UL2034
installed in accordance with manufacturers installation specifications.
Vent F lue
16 Gauge
Strapping around
water heater to
2x1 0 shaped
spacers with five
(5) 16d nails.
2x4 Cleat wf
Two (2) 16d
Flexable Gas
Connection
CHANGES
;; r.MR CHANGE ,p 4PPPOVAL
MUST MEET ALL CURRENT
WASHINGTON STATE CC �S
N
CO
Q N
2 N
0
> s▪ a y
0 m
@ E
@
@ a)
Ea m
� � C
"O
CDa
U
U
co
@
O
0
eL
@
-w
@
O
E
N
@
as
co
as
U
as
0
O p
✓ 0
as
L L
E
0 03
@ -N
o @
-0
aca
c
@ 0)
E�
as a
N o_
0) @
0
0 CD
U @
CO 0 y
t �
rno 0-3
eL y 0)
o = a) =
C.7 v
m o
ca o
O m cn eL
o 0 ( o
0
- ▪ 0 0 O
U SD c
co
• eL coo
a
C U L
7 y N
i - @ C '-
O C co
O a)
6. _ @
>, c
O) C _—
T
as
0
0
0
U
.Q
@
co)
0
0.
cos
d
@
0
0
@
CO
cn
2
0
U
CD
y
@
0
00
(0�'�'0
o���
(' �, ca J E
c
a - @
0 m '-
- ca ca O of
• = m 0
Torn E�
ca ca o
E @ E = o
as
Q E
a m � � CC 0
m o o co
it 0
c @ _0 • CO p QQ))
c > r0n
C DC 4C
- U n;LC ¢ c
0 AR CD
1251 East Leed Drive
CO
LO
CO
253-686-5423
Parcel # - 32022-23-90023 r
I. Plan Name
Floor Plan
Sheet #
5
of 10
Printed on 2/5/2014
at 12:57:35 PM