Loading...
HomeMy WebLinkAboutBLD2023-00289 Remodel Garage - BLD Plot / Site Plans - 3/13/2023RECEIVED VICINITY MAP 1 I c i i PROJECT SITE PARCEL# 320222390024 PROPERTY BOUNDARY SECTION 22 TOWNSHIP 20N RANGE 3W DAMES AND BARBARA ANDREWS-GARAGE ADDITION ELECTRICAL DROP PARCEL# 320222390023 PROPERTY BOUNDARY 1166.00 1251 E. LEEDS DR., SHELTON, WA 98584 PROJECT AREA EXISTING SHED PARCEL# 320222390022 1425.00 EXISTING RESIDENCE ±4353 S.F. INCLUDING GARAGE 1435.00 SITE PLAN 1 "=20'-0" MINI/SPLIT 1101.84 .40: MEM SCALE: 1 "=20 FEET 0 5 10 20 i 0 TOPOGRAPHY NOTE: SITE AND TOPOGRAPHIC INFORMATION FROM PUBLIC INFORMATION AND CITY/COUNTY RECORDS. EXISTING UTILITIES NOTE: EXISTING UTILITY INFORMATION WAS OBTAINED FROM BEST AVAILABLE SOURCES AT THE TIME OF DESIGN. UTILITIES MAY EXIST ON SITE THAT ARE NOT DEPICTED. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR RELOCATION OF CONFLICTING EXISTING UTILITIES WHETHER SHOWN OR NOT. CALL FOR LOCATES 2 WORKING DAYS BEFORE BEGINNING CONSTRUCTION. WWW.CALLBEFOREYOUDIG.COM EROSION CONTROL RESPONSIBILITES NOTE: EROSION CONTROL MEASURES ARE NOT LIMITED TO THE ITEMS ON THESE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL MEASURES. NO SILTATION OF EXISTING OR PROPOSED DRAINAGE FACILITIES SHALL BE ALLOWED. CARE SHALL BE TAKEN TO PREVENT MIGRATION OF SILTS TO OFF -SITE PROPERTIES. SEPTIC TANK SEPTIC LINE 1150.00 1121.00 WELL ELEVATED DECK .40 ADDITIONAL MINI/SPLIT LOCATION APPROX. HIGH WATER MARK PROPERTY BOUNDARY Quaoa- oo;B9 HAMMERSLEY INLET 0 0 0 PROJECT INFORMATION OWNER: JAMES AND BARBARA ANDREWS 8217 S. SHERIDAN AVE. TACOMA, WA 98408-1918 PROJECT ADDRESS: 1251 EAST LEEDS DRIVE SHELTON, WA 98584 PARCEL: 320222390023 ZONING: 18 RESIDENTIAL ACRES: ± 1. 00 CONTRACTOR: ALLEN HOMES CONSTRUCTION DRAFTING: NORTHWEST LINEWORX SHEET INDEX SITE PLAN MAR 13 2023 615 W. Alder Street NORTHWEST LINE 0 1360-951-7699 • www.northwestlineworx.com I NO. DATE REVISION SITE VISIT/MEASURE EXISTING DRAFT PLAN DRAFT PLAN ANNO./DIMS. REVISE PER CLIENT REVISE PER CLIENT REVISE PER CLIENT N I PO n 0 07-20-22 N I N N n 0 N I DD N I •— 01-20-23 N I 0 N) I 0 —J CL w �-- c.n Sheet Contents F V w CC �Z ZU CC cn Q m va- c') Q pp w c:1 O z Q _zw LU U * L W z W > z W N N N c-1 N 00 0o rn ob 0 00 or, Q 2 0 Designed By Drown By WMG Checked By Dote 07-13-22 Project Number 22014 Sheet Number C0.1 1 of 1 EXISTING HVAC UNIT NEW HVAC UNIT O O DAMES AND BARBARA ANDREWS-LOWER FLOOR REMODEL 1251 LEEDS DR., SHELTON, WA 98584 11'-102" EQ 5'-0" EQ 1 1 " 2868 5'-0" 8'— GAME ROOM 90 CFM CEILING FAN N • EXTEND PANTRY UNDER STAIRS 20'-0" 11'-6" 7'— „ 0 10 SMOKE/CO2 DETECTOR 6'-0" 3068 D" r'ROOM 12'-11" SMOKE DETECTOR CLOS` SD 11 '-9" 2 3068 4N CLOSET i • 2. 0 I 21'-6h" / LIVING ROOM / ; / ; � / ; , 2'-0" 5050 5'-0" 11 60610 SGD 5'-10" 4'-6" 10'-52" 3068 UP 4'-0" 0 f/0 00000 REF 3'- 11 I OVERHEAD RANGE VENT KITCHEN 5'-3" 10'-52" ISLAND DINING/ FAMILY ROOM ' SMOKE DETECTOR 2x4 WALL FURRING, TYP. 3068 6'-42" W/D C 50 CFM • VENT 90 CFM CEILING VENT BATE! 2868 � V ru = FLOOR DRAIN BENCH t\ 12'-11" 0 • 0) \o 3068 / OFFICE O 0 c0 0 / i • „ 90610 SGD 9,-0„ 7'-4 " 90610 SGD 9'-0» 11 3'- 11 60610 SGD 6'- „ 15 22'-0" 33'-8" 13'— „ ENERGY CREDITS HEATING: EFFICIENT BUILDING ENVELOPE: AIR LEAKAGE CONTROL HIGH EFFICIENCY HVAC: EFFICIENT WATER HEATING: OPTION 4 OPTION 1,3 OPTION 2.2 OPTION 3.4 OPTION 5.6 TOTAL CREDITS _ .5 _ .5 = 1 = 1.5 = 2.5 = 6 69'— „ LOWER FLOOR PLAN 1/4" = 1'-0" N =x SCALE SET FOR 24"x36" PAPER. REDUCE SCALE FOR NEW HVAC UNIT TO BE PLACED BELOW DECK, ATOP CONCRETE SHELF. CONCRETE WALKWAY BELOW DECK. SHEET INDEX A1.0 LOWER FLOOR PLAN NORTHWEST L 1 N El I360-951-7699 • www.northwestlineworx.com I x 0 I NO. DATE REVISION SITE VISIT/MEASURE EXISTING DRAFT PLAN DRAFT PLAN ANNO./DIMS. REVISE PER CLIENT REVISE PER CLIENT REVISE PER CLIENT 07-13-22 NI N 0 07-27-22 12-28-22 01-20-23 N ) 0 ir— N * in c0 Sheet Contents LOWER FLOOR PLAN z O (I) UM CC CC CI Z z Q 0 � Q Z m Q °� Q w m a O z Q z w *O 00 c, ob 0 00 2 0 I — Designed By Drawn By WMG Checked By Date 07-13-22 Project Number 22014 Sheet Number A1.0 1 of 1 B C D E F 1 1-6' - XO O) Lt. co ;moo O < O O o Is"0 0 W - �XO c;)u_m L.00<= oo0 1 '-6" 3' 3056 SH 3056 SH 3'- DECK 19'-71/2'x21-71i2' 425 sq ft 17' 6' 6068 SGS 6010 ABOVE Covered I Enclosed Deck 16 -5' x 16-8° 274 sq ft 6068 SGS 6010 ABOVE 17' KITCHEN EXHAUST HOODS All exhaust hoods with a capacity of more than 400 cfm sha!I be provided with make-up air at an equivalent rate. The make-up air shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. See plan review checklist item #8 and Mason County policy attached. 5a/ DECK 14-81/4' x 32'-11 1 2' 693 sq ft 3' 3056 SH DN (o 2 1'-6' O > O 0 CD co C < co O co 0 Cr) M u> > O 0 CO CO 0 ,O CO co w c10 co lA < CO 0 CO 0 0 0 1 3' — 3050 SH T Z _ 14'-4` 6'-10` C\i ster Sarni 13 -11 1 '2` x 21 '-51 /2' 300 sq ft Frame Stair Head Room into lower _-;_ Dining Nook 10'-1 1 /4 x 17'-2" 171 soft Vault Line rl room =- 14'0°x12-_- 179sc, 6040 SL 3' 5' 14.-6° r� Family 23-0' x 15-6' 356sq`t 14'-6 1/2 - - 3 6" --61/2" Master Ba:- T-11 314' x 12 = 111so`. O PEIi! BELOW__ -t7 ,C -3 3'4' x 41 sqft Kchen - 12-91.2' --k � C9 m Zo Ze 2-8 BATH 2-4 1 '2" 2'-4" L)N 12- 4' 2' r- 1 01-10" 7'2'.2 4 0ff;ce 13--2 x 13'-11 1 = 167 sq ft 4'-11 1 I2" — ; -- 10' -- 20 SL S.G. 11" 2' 2- Floor Plan Scale 1/4" = 11-0" U 2 0 x 6'-5 1 /2' 2'-4 1 2" 0 6' 10 71_d" '2Wall 16-2'PG- 448 sq t 21'-11 1.2 101-10" _;0" ae2-oor 14-10" LIVING AREA 2871 sq ft 2"- 8'-0 1.2' 3050 FX S.G c °ORCH xE- _ 3050 FX S.G. 6040 SL 3' 9-10' 4-6 1 /2' -612' SLAB x 13'-4 3.8' 5'-1 1 4" -. 5 Optional Man Door O L0 m N Zo 10080 36' - 33'-11 1 i2" Garage 39'-5 1 !2° x 27-0' 1029 sq ft 2c.1 Type X Sheetrock Required. See Note °R302 - Dvrelling;Garage Separation" 10' A 2' 42'-4" Shaped 2x10 spacers will be cut to ensure a tight fit to water heater. Bollard to P rotecl --- Appliances from Impact 6 18080 16' Water Heater Strapping 1/3 Water Heater 1/3 1/3 Platform Must be Anchored to Wall 4'-6" (0 Zo 7 THESE PLANS MUS'BE ON THE JOB SITE FOR INSPECTION CARBON MONOXIDE ALARMS Approved carbon monoxide alarms shall be installed in all new residential construction. They shall be installed in the immediate vicinity outside of each separate sleeping area in dwelling units, a minimum of 1 per floor. Carbon monoxide alarms shall be listed as complying with UL2034 installed in accordance with manufacturers installation specifications. Vent F lue 16 Gauge Strapping around water heater to 2x1 0 shaped spacers with five (5) 16d nails. 2x4 Cleat wf Two (2) 16d Flexable Gas Connection CHANGES ;; r.MR CHANGE ,p 4PPPOVAL MUST MEET ALL CURRENT WASHINGTON STATE CC �S N CO Q N 2 N 0 > s▪ a y 0 m @ E @ @ a) Ea m � � C "O CDa U U co @ O 0 eL @ -w @ O E N @ as co as U as 0 O p ✓ 0 as L L E 0 03 @ -N o @ -0 aca c @ 0) E� as a N o_ 0) @ 0 0 CD U @ CO 0 y t � rno 0-3 eL y 0) o = a) = C.7 v m o ca o O m cn eL o 0 ( o 0 - ▪ 0 0 O U SD c co • eL coo a C U L 7 y N i - @ C '- O C co O a) 6. _ @ >, c O) C _— T as 0 0 0 U .Q @ co) 0 0. cos d @ 0 0 @ CO cn 2 0 U CD y @ 0 00 (0�'�'0 o��� (' �, ca J E c a - @ 0 m '- - ca ca O of • = m 0 Torn E� ca ca o E @ E = o as Q E a m � � CC 0 m o o co it 0 c @ _0 • CO p QQ)) c > r0n C DC 4C - U n;LC ¢ c 0 AR CD 1251 East Leed Drive CO LO CO 253-686-5423 Parcel # - 32022-23-90023 r I. Plan Name Floor Plan Sheet # 5 of 10 Printed on 2/5/2014 at 12:57:35 PM