HomeMy WebLinkAboutBLD2023-00715 - BLD CD Environmental Health Review MASON COUNTY COMMUNITY SERVICES Permit No: HS#112
PERMIT ASSISTANCE CENTER:
(.170311r, <i:, •BUILDING.PLANNING.PUBLIC HEALTH.FIRE MARSHAL j I(] 2.,C)— Lc)r l 15
615 W.Alder Street,Shelton,WA 9858
4
��'.
O \ -f Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone
Belfair(360)275-4467•Phone Elma:(360)482-5269
O BUILDING PERMIT APPLICATION
1 PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
r
Q3 NAME: Lennar Northwest,Inc. NAME: Lennar Northwest,Inc.
cor... MAILING ADDRESS: 33455 6th ave S.Unit 1-B MAILING ADDRESS: 33455 6th Ave S,Unit 1-B
CITY: Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003
PHONE#1: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322
PHONE#2: EMAIL: Sam.Martin n Lennar.com
EMAIL: Sam.Martin(a))Lennar.com L&I REG# LENNinALen JO EXP. 03 /18/24
U PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Sam Martin.Agent of Lennar EMAIL Sam.Martin@Lennar.com
cjMAILING ADDRESS 33455 6th Ave S,Unit 1-B CITY Federal Way STATE WA ZIP 98003
1 PHONE (253)294-1322 CELL (253)294-1322
PARCEL INFORMATION:
^ PARCEL NUMBER(12 Digit Number) 1 2328-5 1-00 1 1 2 ZONING
c�—.� LEGAL DESCRIPTION(Abbreviated) Olympic Ridge 1/,.?‘ FIRE DISTRICT
SITE ADDRESS 411 NE Ridge Point Boulevard CITY
;� DIRECTIONS TO SITE ADDRESS
fffJJJCIS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES NO® SNOW LOAD:25 00 psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
1' TYPE OF WORK: NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER
USE OF STRUCTURE(Residence,Garage.Commercial Bldg,Etc)New SFR using approved Stock Plan k2018-0007 Plan 2631 Elevation B GR
IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS 5 NUMBER OF BATIIROOMS 3
HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Parris]of Bldg)® NO❑
DESCRIBE WORK New Single Family Residence heated and garage unheated
SQUARE FOOTAGE:(proposed)
1ST FLOOR 1137 sq.ft. 2ND FLOOR 1485 s ft. 3RD FLOOR q sq.ft. BASEMENT sq.11.
DECK sq.ft. COVERED DECK El- sq.ft. STORAGE sq.ft. OTHER -82.... sq.ft
GARAGE 594 sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW® EXISTING❑
PLUMBING IN STRUCTURE? YES® NO❑ Ifyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES® NO❑ EXISTING SQ.FT. 13 s ft
EXISTING BEDROOMS PROPOSED BEDROOMS ' TOTAL BEDROOMS
�—
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including arty easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This pennit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X Sdm iIvrL 4-12-23
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL ��
PUBLIC HEALTH r ([7 h 3 �,U 'r C�,q`S^'o,J
TRACT B SANITARY SEWER StBUILDING SETBACKS:
S21'38'31 V 50.00' [POWER EASEMENT FROM: to' SIDE: 5' REAR: 10'
€310- -- — 4
----312- -———- -
314 ——— PROPOSED 2
CONTOURS
---� -----318-
N 320 T
u-i
- -322- trs 'R-5"Medium density residential district
-324 a-——- `- Front yard:10 feet.
Side yard:5 feet for accessory structures and 5 feet for the
-
326---1—_ _ dwelling unit.
Street side yard:10 feet.
BSBL I Rear yard:5 feet for accessory structures and 10 feet for Rr
BSBL TSS dwelling unit.
Street rear yard:10 feet.
;:PATIO) '(C
v 5'� ••� — — 15' 06/23/2023
40 I I APPROVED
MASON COUNTY DCD PLANNING
EAVE HS 112 I S0O1T Ru�y,A(Cp
BUILDING PROPOSED HS 111
ENVELOPE SINGLE FAMILYI
Digitally
HS 113 RESIDENCE I "� se.H,e,,,signed
by Scott
Ruedy
o o': I
co
0-5-o - EH APPROVED
W w Rhonda Thompson 06:27/2023
N ' 2631 � , N
N Public sewer and water
Eo I GARAGE R RI N No
'I
t N
27' CONC.
Too .:::: I...KHI: I DRIVEWAYS al5 0
' c . '.'SS. t UH.'•� ••�'"S' N
STORM :':;`; ::';•`':ice••• ?. 4:', wr
STUB WA LK(,•':77%'',.... .,,.•.. .
lb YD tr. ; :. 5.�h'--- CI
N
•;.' .p�' Llyr,
TRANSFORMER .•®.`•.:'•;•'•'•,',,:'•`'`•'!':
N21'38'31'E50.00' W WATER
� LINE EASEMENT
WM AFN 1933608
.' . . o b. V SIDEWALK
INSTALL SILT FENCE, NE RIDGE POINT BLVD TCE =INSTALL TEMP. CONST. ENTRANCE
STRAW WATTLE, OR
FUNCTIONALLY EQUIVALENT r TSS =INSTALL TEMP. SOIL STOCKPILE
LOT SIZE = 6,000 SF SOIL AMENDMENT NOTE:
SEE BMP T5.13 "POST CONSTRUCTION
IMPERVIOUS SOIL QUALITY AND DEPTH", WSDOE
TOTAL IMPERVIOUS: 2,730 SF (45.5%) STORMWATER MANAGEMENT MANUAL
ROOF: 2,004 SF FOR WESTERN WASHINGTON.
DRIVEWAY: 578 SF
WALK: 40 SF LOT COVERAGE = 2,004 SF 33.4% FLAT WORK NOTE:
( ) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 108 SF (INCLUDES EAVES)
PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Job Number 20\` �""""" 4O LENNAR NORTHWEST INC.
21885 Scale 1'-2o'
Barghausen OLYMPIC RIDGE
Sheet Druwn Dbriggs Consulting Engineers, Inc. HOMESITE 112
18215 72nd Avenue South
Kent,W 98032 PARCEL NO. 12328-51-00112
1 of 1 Dote 3/31/23 425.251.6222 barghausen.com 411 NE RIDGE POINT BLVD, BELFAIR, WA
File:P:\21000s\21885\lot\21885-Olympic Ridge-Plot Plans.dwg Plot Dote/Time:3/31/2023 12:51 PM DBRIGGS