Loading...
HomeMy WebLinkAboutSWG2023-00284 - SWG Application / Design - 6/30/2023 MASON COUNTY 415 N 6TH STREET, SHELTON,WA 98584 rill SHELTON: 360-427-9670, EXT 400 P r: BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2023-00284 APPLICANT BLOSSOM KEITH & ANDREA Phone: Address: 21 E BOUNDARY RD GRAPEVIEW, WA 98546 OWNER BLOSSOM KEITH & ANDREA Phone: Address: 21 E BOUNDARY RD GRAPEVIEW, WA 98546 SEPTIC DESIGNER Bob Paysse - Pioneer Digging Inc Phone: 360-426-1803 Address: 3083 E Mason Benson Road GRAPEVIEW, WA 98546 Site Address: 21 E Boundary Rd Primary Parcel Number: 221045200001 Permit Description: 4-bedroom pressure with a sand lined drainfield Permit Submitted Date: 06/30/2023 Permit Issued Date: 07/24/2023 Issued By: David Anderson Current Permit Fees Paid: $525.00 (additional fees may be required upon installation of system). Permit Expiration Date: 07/06/2026 (based on date of inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY "V • DATE RECENED: MASON COUNTY (p • �(� . 02 c › 017 COMMUNITY SERVICES AMOUNT RECEIVED:525— RECEIVED BY: n -^C W Cn m Public Health(Community Health/Environmental Health) /��/T[ < cn �N2765tre t 56&1400 n�A98584.en1� SwG 202�, - 0 3O21 Z Cl) 415 N.6th Street Shelton WA 98581 Cl) 0 ON-SITE SEWAGE SYSTEM APPLICATION APPLICANT Pr-,ONF m m KIETH BLOSSOM �', ; Z c MAILING ADDRESS-STREET,CITY.STATE.ZIP CODE 21 E BOUNDARY RD �G G GRAPEVIEW WA 98546 _ m SITE AD kESS-STREET,CITY,ZIP CODE ` % xi 21 E BOUNDARY RD G GRAPEVIEW WA 98546 I N' NAME OF DESIGNER r� , PHONE I N ROBERT H. PAYSSE `''� 360-426-1803 NAME OF INSTALLER PHONE v TBD I PERMIT TYPE(select one) IN W W DRINKING WATER SOURCE i { u7 RESIDENTIAL OSS COMMUNITY OSS COMMERCIAL OSS In PRIVATE INDIVIDUAL WELL 5 PRIVATE TWO-PARTY ELL Z TYPE OF WORK(select one) PUBLIC WATER SYSTEM t Q 6NEW CONSTRUCTION/UPGRADES Epp REPAIR/REPLACEMENT OTHER DETAILS(select all that apply)) ❑ TABLE IX REPAIR I CJl SUBMITTALS ❑ SURFACING SEWAGE h7 tXISTING FAILURE ❑SHORELINE Up DESIGN FORM(REQUIRED) VSEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE O I N 'rvAIVER(S)(IF APPLICABLE) 4 0.22 n t x IO DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) NORTH HWY 3. LEFT ON MASON LAKE RD. FOLLOW TO MASON LAKE. LEFT ON o MASON LAKE DRIVE EAST. CONTINUE TO BOUNDARY RD ON RIGHT. SITE IS r I FIRST LOT ON LEFT. -I o Ht ISITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I OFFICIAL USE ONLY BELOW THIS LINE IUPGRADE I FAILURE SOURCE(for reporting purposes) ❑VOLUNTARY 0 MAINTENANCE/PUMPING 0 BUILDING PERMIT El HOME SALE ['COMPLAINT ['OTHER: -1 OR SOIL LOG but- 5- COMMENTS/CONDITIONS - o -/- L5 �Q ,f� 5ffy& 60' �Gi AK - -S l6 �e /Roils of fi)i TV : (7 L5 4-2 ?" 6I-S Z1-361, Ye(fy Con p a c+C4A cvi1h fill Pei of 2 36_Go t. v� m S i)/e f llf4( RECORD DRAWING AND INSTALLATION REPORT SOIL CODES: ...V. VERY_.G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL. 1PRSIGTURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE 77b/7oz3 7/(/2076 0. — 7(z `f 12073 THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED 12/7/2015 l ,M_. . DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 1 0 4 — 5 2 — 0 0 0 0 1 A design will be reviewed when 3 copies of each of the following are submitted: a ! Completed design form that has been signed and dated. ''Scaled layout sketch,including alllapplicable items on checklist ' Scaled plot plan,including all applicable items on checklist. Cross-section sketch,including all applicanle'i}diii5'� `�iircklist,'_.:.. • This form ma be scanned and available for .ublic view on the Mason Coun Web site.Maximum •a#er size: II"X 17" Permit Numbe • SWG 20z3—A '2 el Designer's Name: ROBERT H.PAYSSE Ap I ' s s Name: KIETH BLOSSOM Designer's Phone Number: 360-426-1803 'L; •ddres: PO BOX 2626 Designer's Address: 3083 E MASON BENSON RD f��,���0 BELFAIR WA 98528 GRAPEVIEW WA 98546 �v� ity State Zip City State Zip ., _ _ DESIGICPARAMTERS Treatment Device • Glendon Biofilter 0 Sand Filter 0 Mound NiSand Lined Drainfield 0 Recirculating Filter,Type: O'Aerobic Unit Make/Model 0 Disinfection Unit Make/Model Ct!u.°'r;1�' a:;r c 1.:,< �;,,:1-;'. Drainfield Type ❑Gravity lit Pressure Di Trench 0 Bed 0 Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 4 Schedule/Class SCH.40 Daily Flow:Operating Capacity 360 gpd Length VARIES ft Daily Flow:Design Flow 480 gpd Diameter 1.25 in Septic Tank Capacity(working) 1500 gal Number 3 Receiving Soil Type(1-6) 1 Separation 9 ft Receiving.Soil Appl.Rate 1.0 gpd/ft2 Orifices g Required Primary Area 480 ft2 Total Number of Orifices •-.4..-::...,_ AO Designed Primary Area 480 ft2 Diameter 3/16 in Designed Reserve Area 480 ft2 Spacing 48 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 160 ft Schedule/Class SCH.40 Elevation Measurements Length 18 ft Original Drainfield Area Slope 7 % Diameter 1.25 in New Slope,If Altered 7 % Preferred manifold configuration used? I 'Yes 0 No Depth of Excavation Up-slope 24+24=48 in Transport Pipe from Original Grade Down-slope 22+24=46 in Schedule/Class r l..,,....SCH.40 A Designed Vertical Separation 12+ in Length • '•Sri'' ft 9 Gravelless Chambers Required? 0 Yes 17i No 0 Optional Diameter 2 in Pump Required? lid Yes 0 No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 6 , Diff.in Elevation Between Pump&Uppermost Orifice 5 ft Dose quantity 80 gal * Drainfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 2250 gal Uppermost Orifice Higher 0 Lower than Pump Shutoff Pump c�pttpl� ch k those required. Capacity @ Total Pressure Head 23.6 gpm ' er (j'il`' - 2•r I'Event Counter Calculated Total Pressure Head 14.3 ft If Timer: Pump on 1.5 MIN ,pump off 4 HRS Ii MASON COUNTY ENVIRONMENTAL HEALTH Comments JUL 2 4 NV DJA , "''DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 1 0 4 — 5 2 -- 0 0 0 0 1 Permit Number: SWG DESIGN CHECKLISTS I ` — Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch lil Test hole locations 621 Drainfield orientation and layout Reference depth from original grade: Iii Soil logs fii1 Trench/bed dimensions and g Septic tank g Property lines critical distances within layout i ' Drainfield cover Ed Existing and proposed wells Gil D-Box/Valve box locations Reference depth from original grade within 100 ft of property g Septic tank/pump chamber and restrictive strata: ili Measurements to cuts,banks,and locations l2f Laterals,trench/bed,top and surface water and critical areas l,Z( Observation port location bottom 61 Location and orientation of 6t! Clean-out location 0 Curtain drain collector curtain drain and all absorption ff Manifold placement 0 Sand augmentation components g Orifice placement Other cross-section detail: iZI Location and dimension of lid Lateral placement with distance g Observation ports/clean-outs primary system and reserve area to edge of bed g Other Information 6d Buildings rif Audible/visual alarm referenced Yes No !id Direction of slope indicator g Scale of drawing shown on scale E6 0 Design staked out lig Waterlines bar ❑ RI Recorded Notices attached Iitl Roads,easements,driveways. 0 g Waiver(s)attached parking 0 g Pump curve attached 0 North arrow and scale drawing 0 g Evaluation of failure shown on scale bar Non-residential justification ❑ RI Waste strength ❑ 131 Flow DESIGN APPROVAL The undersigned designer must be notified by ' staller at time of installation lif Yes 0 No t:24fisc .4 7izti/ z__.3 Signature of Dcsi er Date 44 The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to b in compliance with state and local on-site egulations: R� Y p ED /Z 41 702--/ASON JUL ? ` 2023 Environmental Health Specialist Date 0(/N p 71'&vonN CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: O✓A MENT HEALry ✓ The design is stamped"Approved"by Mason County Public Health.✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: 7 /[ r t/ /Z °Z6 ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. scanned and available forpublic view on the Mason CountyWeb site. This form may be Updated Date: 12/7/2015 ... _. 6/):.CIA, 1� — _ °c�oF kF�R ./' ''-9T 7 4 All/Iv,. 2r, Z'i s ,%********74.7 ( 1:1111 EXIST. FAILED O DRAINFIELD I a �;4,;� PROPOSED po ,-` EXIST. FENCE.______ i 4_B ED ROOMI o / • • / DRAINFIELD 70 p -� L �__-----_ � D D I i--yT�� �- 1 Q < �,- i l i --../ '---1:401077;;;a74wFi ,--- o , i .� \. PUMP OUT& ABANDON EXISTING I TANK. INSTALL NEW > / SEPTIC 0./pW TANK EXISTINGa / -Po HOME APPROVED I O I JUL 2 4 2023 MASON COUNTY ENVIRONMENTAL HEALTH IL\k, 1 DJA I I rn O -s a '� �� D t keg. h •.'", 3 it-Y • , 1`• • r*t N. i � sttoaTT :�i z ♦ �Q' ROBERT H 9AYSSE .(1,� '..17. ri' N EXPIRES •••• d EXISTING WELL AN ASBUILTI INSTALL SIGNOFF FEE WILL BE CHARGED AT TIME OF INSTALLATION PIONEER DIGGING INC. CUSTOMER: KIETH BLOSSOM TESTHEST HOLE 2 (}IS TES Gas PARCEL# 2210452-00001 HOLE I: T Is its 47:6 t'i\ SOS .COMPACTION) 1 SEPTIC DESIGNS ADDRFSS: 21 E BOUNDARY RD ROOTS @ 55 RtSS ' DRICLANER THIS IS NOT A SURVEY.REFERENCES INCUUOE.APPUCANTICOUNTY PROVIDED 3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER ROBERT H PAYSSE PLATS OR SURVEYS.FIELD MEASUREMENTS AND COUNTY GIS DESIGN INTENDED FOR SEPTIC OFFICE 360-4261803 FAX 360-427 2353 SHEET: SITE PLAN SCALE 1"=20' DEPARTMENT/AGENCY REVIEW PROPOSED SIGNDER NOOTP ESPONSIB E FOR SETBACKS UNRELATED TNT MAY BE SUBJECT TO O SEPTIC COMPONENTS AN ASBUILT/INSTALL SIGNOFF FEE WILL /(1� BE CHARGED AT TIME OF INSTALLATION OB PORT OAt L9 _& C/O (X4) F°ck--o '�FpR P s • kAA --\,-k5A,.. . .. .... r 4AAA ._ „. .„ . f kik. w......v i-Iv5oktik ,. 4?--) ..‹)‹, )-4.S y ., .. y ‹, ..fill, v A, A. 4 INt.. -\A ,i, / , lq),"!) ii . ---- NEW SEPTIC TANK ' & PUMP TANK -___ 4 1-A 7 / i - EXIST. FENCE---__ / i , di'. q / ----`-````` lV ,r JUL 2 4 20 ____-- ---- ` 23 PR -�'�—` 7 - M SO y`�-�� / -0' �l C.i Tl!p�A MEOq k ', EAIi 1 I �� i i J Ii -.. I I:.... / 1 / ��y n wl i . jg'p • 1 EXPIRES PIONEER DIGGING INC. CUSTOMER KIETH TEST HOLE I: TEST HOLE 2 PARCEL# 2210452-00001 0001 Pls 0-27 GLS I8 60 G c�\4S 27-60 G.MS(SOME COMPACTION) { SEPTIC DESIGNS ADDRESS: 21 E BOUNDARY RD ROOTS @ 55 ROOTS @ 53 3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ROBERT H.PAYSSE FPuyTSSORSSURVECLMMEID 85�DMEASUREI.ENTST A SURVEY. R REFERENCES DESIGN INTENDED OFFICE 360 4261803 FAX 360 427 2353 SHEET: DF DETAIL SCALE 1"=10' PURPOSES ONLY PROPOSED PMENT MAY BE SUBJECT TO OTHER DEPARTMENT/AGENCY REVIEW DESIGNER NOTRESPONSIBLE FOR SETBACKS UNRELATED TO _SEPTIC COMPONENTS 3 A m,n i rvm off 6`' c'f Slind nuc"SM be Wedit ;,Y ';< \,.,-r. . -ttt 4a1i ve type 1 Sett C'i/ i e cliDon'CA b ne jt OBSERVATION PORT •5flc'ri-cr'Ycv)•ii'Th .YAe5c/6atin/e(r It *plat - moi 6e i4.4 cleiiee(b y E , ree aikeltp 1031- CLEANOUT ' OA. •4111P4Se IZIGINAL& FINISHED GRADE !— II I .:,<. 1 CA5 NE'rDEP) I g 1 1 I I ... • I u1 Iu FILTER I I I FABRIC s. I WASHED N I I N ,r : ROCK .;•_.::.-.:r•:._. O...•.•.•.•.!.•. .:_•:-.:_.:-.:-•.-•.- • • -..-•- •:_•- _, i.•.f�fa:.,..0- ia...•aa,..4l: COMPACTED ,. . •. •.-_•_ _ LAYER (TH2) CO 4 1-. .. :1.. .j ' 4" C-- SAND-:' .. - •.. • r ► .: . I( I AP!. ,• . 0„.. : . 41 OBSERVATIONyi P. Y �i 0;•• F08EIT�H}�PAYSSE . .4PORT TO BOTT. OF <ti SAND. (X4) 1 ._.._.. EXPIr ES.. RESTRICTIVE LAYER (VERIFIED DEPTH) JUL 2 4 2023 THREADED CAP 24" RISER/LID MASONCOUNTYENVIRON�dENrq�H OR VALVE BOX NLrH DJq El fib"ORIFICES 012:00 IN/ SHIELDS ‘'.I... .-III. IP. 1�1 .1 . n ^ SWEEP •r•r-•r:r:r—:Y-:r. :r ;r-;r-;r _ _ ;41�1�.1:1;�:1i1a.1�.1�.1�. BALL d = P •r-•r•r•r.•_..._..—.•r-•-•r-fir., _.._.•_.•_.•.-,•r.e. •r_ ,,,S,0 .1 VALVES CHECK GLUED TEE VALVES ADJUST TO # (AS NEEDED) AN,, UILT/INSTALL SIGNOFF FEE WILL OF LATERALS BE CHARGED AT TIME OF INSTALLATION CUSTOMER KIETH BLOSSOM TEST HOLE I: TEST HOLE 2: PIONEER DIGGING INC. 18-60 G 0-27GLS 7 • PARCEL#:22104-52-00001 GMS 27 60 GMS(SOME COMPACTION) SEPTIC DESIGNS ADDRESS: 21 E BOUNDARY RD ROOTS @ 55 ROOTS @ 53 D(SCWf4T2,TMSIS� A9U�¢��y,�ccr*,' RE. ENCES INCLUDE'PEST NINTE UNfY PRSEM) 3083 E MASC-N BENSON RD. GRAPEVIEW,WA 98540 DESIGNER: ROBERT H.PAYSSE PUTS ORSNr-'4SetAEABIIREME COONCLUDE ESIGNINTENOEOFORSEPTIC PURPOSES ONLY. :I:OPQ90 0 OPMENT MAY .GE SUBJECT 0,"- r_G OFFICE 360 4261803 FAX 360 427 2353 SHEET: DF DETAIL(2) SCALE NA DEPARTMENTGGENCY REVIEW.'Oc51:n._I<;?-"i.ITCN1...3.EF1'R. ,.�_:sla.<w,TEo To I SEPTIC COMPONENTS. — 24"RIBBED RISERS W/BOLT ON WATER-TIGHT LIDS FLEA,\OIJ 1 USE RISER LID ADAPTERS WITH NO GASKET LIDS D FINISHED GRADE • -.LT.: ,.. WATER-TIGHT _ t' ,t i JOINTS . INLET . , Orli OUTLET TWO WAY TEE Zi- i' WATER-TIGHT • I JOINTS :�„ �i•. •h ;•�� • 1FFIIL R ®VE TANKS MUST BE :4: ON STATE DOH '; /• S JUL 2 4 2023 APPROVED LIST ` • OF'SEWAGE '. 7. •SQN COUNTY r�y�RORENTAL HEATH TANKS .• *` A PUMP TANKS VA I ,,.. �� OVER 1000 GAL. ••.: 4. • REQUIRES TWO d�A1:®���Ar.��.ansan:'•: . ACCESS RISERS *`. •.4g-- •;' t. •.?: .'z".cd;:; .. ..... ...; ;:t• ,,, ot ww..,�04 TO GRADE �+` • ?i; • PUMP TANKS 0.1• RF, �iro"a+,rsse `' LOCATED AT HIGHER AQUAWORKS - ;;�� ':ix F., ELEVATION THAN CONTROL PANEL ExPI;.�s DRAINFIELD MUST t��nMER EVENT HOUR METER �- ELECTRICAL WORK PONE 24"RIBBED RISERS HAVE ANTI-SIPHON c BV LICENSED ELECTRICIAN W/WATER TIGHT LIDS DEVICE INSTALLED. '$ * I - FINISHED GRADE r I E LECTRICAL CONDVIT ICI 1 -- TRANSPORT LINE INLET n UNION& BALL VALVE 1500 GALLON WATERT/GHT CONC.-RE IE PUMP TANK (28.5 GAL./IN.) WATER-TIGHT JOINTS PRESSURE TRANSDUCER 1 (OR FLOATS) I CHECK VALVE USE TANKS FITTED J W/CAST IN WATER TIGHT FITTINGS FOR USE RUBBER INLET/OUTLES AND • PUMP BUCKET: GROMETS FOR CAST IN RISER BUCKET HEIGHT MUST BE TRANSPORT LINE ADAPTERS TO AT LEAST HEIGHT OF PUMP — AND ELECTRICAL ENSURE WATER ON RISERS. MAKE TIGHTNESS a . " ' • :• • . a SURE ALL HOLES ARE WATER-TIGHT T CUSTOMER. KEITH BLOSSOM SCALE NA PIONEER DIG�1N�, 11 V C. PARCEL# 22104-52-00001 INSTALL TANKS ON ORIGINAL OR SEPTIC DESIGNS ADDRFSS:21 E BOUNDARY RD COMPACTED LEVEL SOILS. RUN CROSS 1 3083.E,MA.SOON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ROBERT EL PAYSSE CONNI CTIQNS INTO ORIGINAL SOILS TO OFFICE-360-426-1803 FAX-360-427-2353 SHEET: TANKS SCALE NA AVOID SE'T1I JG. '+ t DINO Pumps. 4 Pump Specifications I 280 Series 1,'2 hp it Submersible Effluent Pump Linn{PER WW1 ti :% ilo II Sh r. iz 1111111 r'':a: . lip, . I,L'< ROBE 51 N31YNYSSE `• 4.,/ ' :uiiIi:::: �` ♦ - .. ell ('i \. «. MI „■ ._: ■■ 4 EXPIRES • . _j.. ' APP ■■■■■■■■■■■ai■ = ROV�� III NEVEM ■■■■■■■■■■■■►�■ s■iu■:■a■■:03 :: 70. MASON Z 4 2�23 0741001117110..1. N COUNTY E DJA Nr+IENTAL HEALTWJ . a'wr.auu..e..r r.r.r..r li.i....10..4.1Prr... let LATERAL LATERAL FEEDER TOTAL ORIFICE ORIFICE ORIFICE DIST.TO TOTAL TOTAL LATERAL# LENGTH PIPE SIZE LENGTH LENGTH DISCHARGE SPACING 1ST ORIFICE HEAD SIZE(inch) ORIFICES (feet) (inches) (feet) (feet) RATE(gpm) (feet) (inches) (reef) 1 48 1.25 3 51 3/16" 0.59 4 24 12 0.39 2 56 1.25 9 65 3/16" 0.59 4 24 14 0.67 3 56 1.25 18 74 3/16" 0.59 4 24 14 0.76 DRAINFIELD HEAD(feet) 1.82 TRANSPORT UNE HEAD(feet) 0.50 ELEVATION CHANGE(feet) 5 RESIDUAL/SQUIRT(feet) 2 FXTRP-LQSS/FITTINGS(feet) HAD rgrrt.ifrti TOTAL DYNAMIC HEAD(feet) 14.32 TOTAL GALLONS PER MINUTE 23.6 PIONEER. DIGGING, INC. ARCOEIM#E2210-00001M SEPTIC DESIGNS ADDRFSS: 21 E BOUNDARY RD 3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ROBERT H.PAYSSE OFFICE-360-426-1803 FAX-360-427-2353 SHEET: CALCS SCALE NA 1,e'wk; WifiTTIPiGS!feet). 1 installation & System Notes 1. Installer must contact designer for final inspection of the installation prior to cover. All components, including tanks, lids, transport line,drainfield,and water lines must be open for inspection. A$350.00 fee will be charged for time involved with the inspection of the installation and creation of the record drawing. The designer reserves the right to charge additional fees if multiple visits are needed due to installation errors or inaccessible components. 2. This septic design must be installed by a certified installer with the local health department. All components shall be installed according to state,county,and manufacturer requirements. For Homeowner Installs,the owner must get approval from the designer and local health department prior to attempting installation. 3. Designer is not a surveyor. Installer must familiarize themselves with property line locations prior to installation. Any confusion or conflicts with line locations should be reported to the property owner. A licensed surveyor may be necessary prior to installation to confirm all line locations. Any discrepancies found must be reported to the designer immediately. 4. Drainfield area may only be cleared by a licensed installer familiar with sensitive drainfield area preservation. The builder, lot developer, or property owner shall not clear the drainfield area. Any clearing required for drainfield installation shall not remove or disturb any top soil in Primary and Reserve areas. Removal or disturbance to drainfield soils could render design void. 5. The property owner and installer are responsible for locating all underground utilities (ex. water,gas,electric) prior to installation. Any utility locations shown within design drawings are likely approximate and may not be exact. 6. All proposed tanks must be installed on original soils or compacted gravels. Extend all tank connection lines out onto original soil to avoid settling issues. Risers and lids must be brought to finished grade and left accessible for future operations and maintenance. Component manufacturers (ex. ATU,Glendons,) may have other requirements not listed within this design. 7..Aikelectrical wiring shall be done by a licensed electrician or homeowner(if allowed)and-rn t;be permittedthpough Labor and Industries. 8. The proposed septic system should be installed in dry weather conditions. Any failed attempts at installation during wet weather conditions may render this design void. 9. Maintain 10ft to waterlines with all septic components. If less than 10ft is required,sleeving in sch.40 pvc is required. If sewage transport lines and waterlines must cross, waterline must be 18" above sewage line with one of the lines sleeved in sch. 40 pvc 10ft in each direction of crossing. 10. This design may include waiver applications with specific mitigation measures pertaining to installation,operation and maintenance of the proposed components. 11. Stormwater runoff,footing drains, roof drains must be diverted away from any septic system components. No curtain, foundation, perimeter drains shall be installed 30ft downslope and 10ft upslope of drainfield--cease raermittodttt ro'a-sh 12.This design is site specific and intended to meet state and county requirements that are related to the system components being proposed. Any placement of proposed buildings, proposed wells or other non-related items on these drawings may or may not meet other requirements. 13. All onsite septic systems require regular maintenance to verify satisfactory operation. The system owner/operator is responsible for the continuous operation and maintenance of the system per WAC 246-272A. For op i- Md maintenance information, refer to Mason County Public Health Homeowner's Manual,which should be received after instafiaA p 14. System owner should be cautious of landscaping around septic components. Root intrusion JUL , can cause premature failure of the drainfield area. In addition, bushes and trees should be kept MASON ' 2023 away from lids and other septic maintenance points. • 'NNTyENyf rz `1,1-tchanges made at time of installation may impact designer calculations, pump sizing,'a^ " " .;iit� .+;.' '"� !"•11 compliance w/county and state requirements. Contact designer prior to install w/any proposed variations from design. Changes may result in additional fees and permitting. �wJ '•s CUSTO PIONEER DIGGING, INC. PARCELn#:22104-0000011�M s Rena' vwrssE • 4.;q:::;::),,ASEPTIC DESIGNS ADDRFSS: 21 E BOUNDARY RD r 'P-rt 3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ROBERT H.PAYSSE EXPIRES OFFICE-360 426-1803 FAX-360-427.2353 SHEET: NOTES SCALE NA Sand Lined Trench Systems-Recommended Standards and Guidance Effective Date: March 2014 Introduction Sand lined trenches provide biodegradation or decomposition of wastewater constituents by bringing the wastewater into close contact with a well developed aerobic biological community attached to the surfaces of the filter media. This process requires unsaturated downward flow of the effluent through the filter media. The media may be coarse mineral sand or equivalently sized crushed glass meeting one of the media specifications listed in Appendix A. As a departure from the intermittent sand filter, the media is not contained in a watertight vessel. Instead, the media is placed in trenches or beds in the native soil. Proper function requires that influent to the sand filter be distributed over the media in controlled, uniform doses. In order to achieve accurate dosing, these systems require timed dosing with associated pump chambers, electrical components, and distribution network, with a minimum of 4 to 18 doses per day(depending on sand media used) spread evenly over a 24 hour period. The effluent is absorbed into the native soil at the bottom of the sand lined trenches, which accomplishes dispersal into the subsoil environment and some further treatment. A sand lined trench is a combined treatment component and soil dispersal component. Possible Applications: A sand lined drainfield trench (sand filter) may be selected for a site with excessively permeable (Type 1) soils. The addition of 24 inches of filter media(coarse sand) to a pressure distribution soil dispersal component provides the wastewater treatment not provided by the Type 1 soil. Treated wastewater is discharged directly to the receiving soil for dispersal into the subsoil environment. See Figure 2.1. If the soil adjacent to the layer of drainrock atop the sand media is Type 1, additional filter media sand or an impervious material must be placed between the type 1 soil and the drainrock making up the trench's sidewalls and end walls to prevent short-circuiting. When sand is used for protection against short-circuiting, a minimum of six (6) inch width of filter media sand is required. The sand bed under the drainrock will also be widened by six (6) inches on each side. See Figures 2.2 and 2.3. When an impervious material is used, it must be 30 mil PVC and must extend from above the gravel bed to six (6) inches below the graveVsand interface. See Figure 2.4. A sand lined drainfield trench (sand filter) may also be selected for a site that has its more suitable soils for dispersal (and further treatment) at a depth greater than three feet. Filter media(course sand) is placed below the drain rock to provide adequate levels of treatment so deeper soils more suitable for dispersal into the subsoil environment can be "reached." See Figure 3. A bottomless sand filter is a special case of sand lined drainfield trench in which a 30 mil PVC lined enclosure is designed and installed for containing the distribution system and/or filter bed above grade. It is quite similar operationally to an intermittent sand filter, but is not lined on the bottom. A bottomless sand filter is selected typically to utilize more suitable soils high in the soil profile for dispersal and treatment. The enclosure for the filter bed must be designed by a professional engineer if the containment walls are over four feet in height measured from the bottom of the footing to the top of the walls. See Figure 4. APPROV JUL 2 4 2023 MASON COUNTY ENV;' D. DOH 337-013 Page 7 of 31